Printer Friendly

Treatment of nonvariceal gastrointestinal hemorrhage by transcatheter embolization.

1. Introduction

Acute gastrointestinal (GI) hemorrhage is a commonly presenting medical emergency having a hospital mortality of around 10% [1]. Presentation may vary from insidious blood loss to potentially life-threatening hemorrhage [2]. The bleeding site determination is challenging as it involves entire gastrointestinal tract [2]. Upper gastrointestinal hemorrhage patients present with hematemesis or melena and the bleeding point is proximal to the ligament of Treitz, whereas gastrointestinal lower haemorrhage patients present with melena or hematochezia and bleeding point is distal to the ligament of Treitz [3-5]. Bleeding ceases spontaneously in approximately 75% of cases and can recur in 25% of cases, resulting in significant morbidity and mortality [6].

Therapeutic options available for patients with acute GI hemorrhage include conservative medical management, endoscopic coagulation, vasopressin infusion, therapeutic transcatheter embolization, and surgery [7,8]. Endoscopy is considered as a first-line diagnostic and therapeutic procedure; its sensitivity reaches 100% in upper gastrointestinal bleed but in case of lower gastrointestinal bleed only probable bleeding source can be found (60% of cases). In stable patients, radionuclide and CT imaging plays a great role. Tc-99m RBC scintigraphy is more than 90% sensitive and specific in detecting a bleeding site anywhere in gastrointestinal tract. However, its limited resolution does not allow precise gastrointestinal bleed localization.

Endoscopy can fail in approximately 32% of cases because of presence of stool, blood clots, and technical difficulties as time required for patient's preparation for colonoscopy [9]. In addition, bleeder source in small bowel is not accessible via colonoscope [10]. Significant morbidity and mortality are associated with emergency surgery [11]. Higher rates of complication and rebleeding were encountered in patients treated with vasopressin [12]. Nusbaum and Baum first described mesenteric angiography for acute GI hemorrhage in 1963 [13]. In 1972, Rosch et al. successfully controlled acute gastric hemorrhage by gastroepiploic artery embolization using autologous blood clot [14]. Due to significant technical improvements in the past 10 years selective therapeutic transcatheter embolization has become a safer procedure and is now widely used for acute GI hemorrhage management [15].

The purpose of our study was to investigate the sensitivity of mesenteric angiography, technical success of hemostasis, clinical success rate, and complications of therapeutic transcatheter embolization for the treatment of acute nonvariceal gastrointestinal hemorrhage.

2. Materials and Methods

2.1. Study Group. We performed a single-center (from February 2004 to February 2011) retrospective survey of all patients in whom therapeutic transcatheter embolization was attempted for control of acute gastrointestinal bleeding.

2.2. Patient Selection. All acute GI hemorrhage patients who underwent mesenteric angiograms during this period were enrolled. These patients had been referred to by abdominal surgeons, emergency room (ER) physicians, or gastroenterologists, and procedures were performed by experienced interventional radiologist.

2.3. Clinical Data. The clinical and laboratory data, imaging and endoscopic findings, and care provided as well as the outcome data were obtained from medical records of our hospital. The following parameters were collected for each patient: age, gender, presenting symptoms, severity of hemorrhage, site of bleeding, comorbid, number of units of blood or packed red blood cells transfused, history of coagulation disorder, and findings of prior endoscopy or scintigraphy. Angiographic characteristics include segmental localization of bleeding in the gastrointestinal tract, vascular territory which is corresponding, catheters used for embolization, technique of embolization whether selective (proximal) or superselective (distal), repeat angiographic procedures, and type of embolic agent(s) used. Complications were divided into intraoperative and postprocedural complications. Follow-up duration as well as conservative or surgical management of complications was also documented.

2.4. Angiography and Embolization. Celiac, superior mesenteric, and inferior mesenteric angiography was performed transfemorally using 4 Fr or 5 Fr Cobra or Simmons type catheters (Cordis). Selective SMA angiography was also done by advancing catheter in different branches to evaluate the jejunal, ileal, ileocolic, and colic branches. Once the bleeding site was determined, then superselective catheterization was usually performed using a 2.7 Fr microcatheter (Progreat-Terumo), which is inserted coaxially through the macrocatheter. Superselective embolization was attempted by positioning the catheter as close to the bleeding site as possible. The materials used for embolization included microcoils (Cook and Balt), gelfoam, and polyvinyl alcohol particles (Boston Scientific). Other than active bleeding or pseudoaneurysm indirect sign for abnormal site was described when there were arteriovenous fistula vascular tuft, early filling vein, or a hyper vascular mass. In certain cases where there was endoscopic finding of active bleeding from duodenal region and a negative arteriography, a prophylactic embolization of the gastroduodenal artery was performed using Sandwich technique. In this the catheter is placed distal to the bleeding site followed by placement of coil, and then the catheter is withdrawn proximal to the bleeding site with deployment of another coil to sandwich the bleeding point in between. This technique ensures any retrograde filling of the targeted portion of the vessel embolized. In few cases with severe vasospasm intra-arterial nitroglycerine was also given.

All procedures were performed by vascular access at the level of the common femoral artery using 5 Fr vascular access sheath (Arrow, Medcomp). Postexamination, manual compression was maintained at puncture site with the patient lying in supine position for hemostasis.

2.5. Definition and Data Analysis. Successful embolization is termed when there is devascularization of a focal lesion or reduction or stoppage of flow to the vascular bed. We defined outcome criteria in accordance with the guidelines of the Society of Interventional Radiology (SIR) [16].

Technical success was described as immediate cessation of extravasation on postprocedure angiography [16].

Clinical success was described as nonoccurrence of bleed or hemodynamic instability within 30 days after embolization on follow-up evaluation. Monitoring was performed to evaluate signs and symptoms of intestinal infarction or ischemia [16].

Rebleeding was described as drop in hemoglobin >1g/dL in the presence of overt GI hemorrhage within 30 days. An ischemic event was defined as bowel ischemia or infarction that required surgery [16].

Data was entered into SPSS statistical software version 19.0. Mean and standard deviations were computed for quantitative variables. Frequencies and descriptive analysis of the variables also measured.

3. Results

From February 2004 until February 2011, a total of 200 patients underwent mesenteric angiography for acute GI hemorrhage at our institution. 114 patients (57%) had contrast blush or abnormal vascularity in the GI tract and underwent therapeutic transcatheter embolization.

There were 134 (67%) male and 66 (33%) female patients with male-to-female ratio of 2:1. Median age was 57 years (range: 8-97 years).

28 patients present with hematemesis, 66 with melena, and 106 with per-rectal bleeding. Severity of the symptoms was also calculated which were mild (n = 74), moderate (n = 96), and severe (n = 30). These are summarized in Table 1.

We also evaluated the effect of associated comorbid conditions which predispose to GI hemorrhage. 44 patients had no comorbid disease, 28 had infectious disease, 24 had chronic liver disease, 22 had hypertension, 15 had diabetes mellitus, 20 had chronic renal disease, 21 had malignancy, 10 had trauma, and 16 patients had miscellaneous comorbid diseases.

Blood was transfused in 145 (72.5%) out of 200 patients. Coagulation profile was deranged in 76 (38%) patients; the rest presented with a normal coagulation profile.

Prior RBC-tagged scintigraphy was performed in 62 patients. In 49 (79%) it showed activity corresponding to bleeding site. Majority of these patients had lower GI haemorrhage. Endoscopy was also performed in 93 patients of which 66 (70.9%) were positive.

On mesenteric angiography 47 patients (41%) had upper gastrointestinal hemorrhage, whereas 67 (59%) had lower gastrointestinal hemorrhage.

Angiographically positive sites were stomach 10 (8.8%), duodenum 37 (32.5%), jejunum 9 (7.9%), ileum 10 (8.8%), caecum 29 (25.4%), ascending colon 8 (7.0%), transverse colon 1 (0.9%), descending colon 2 (1.8%), and rectosigmoid region 8 (7.0%).

Embolization was technically possible in 112 of 114 patients, reaching a technical success rate of 98.24%. In one patient technical failure was due to inability to catheterize the supplying artery. This patient had blunt abdominal trauma and presented with a large pseudoaneurysm filling from the inferior pancreaticoduodenal artery. After selective catheterization of the superior mesenteric artery multiple collateral vessels was seen at the origin of inferior pancreaticoduodenal artery with retrograde filling of gastroduodenal artery. Despite multiple attempts the collaterals supplying the pseudoaneurysm could not be catheterized. The second patient was a young woman who presented with per-rectal bleeding. Angiogram demonstrated an abnormal lesion in the rectum filling in the venous phase. There were multiple phleboliths suggesting venous hemangioma. Findings were discussed with referring surgeon and it was decided not to embolize this lesion due to low vascularity and risk of bowel ischemia.

Arteries primarily embolized were the gastroduodenal artery (n = 36) Figure 1, ileocolic artery (n = 28) Figure 2, right colic artery (n = 12), jejunal branches of superior mesenteric artery (n = 10), left gastric artery (n = 9), superior rectal artery (n = 7), ileal braches of superior mesenteric artery (n = 5), left colic artery (n = 4), and middle colic artery (n = 1).

We also evaluated the catheters used for angiography. In 109 (54.5%) patients microcatheter was used, whereas in 91 (45.4%) angiography was performed with regular 4 Fr catheters. Cobra catheter was used in 174 patients while Simmons catheter was used in 26 patients.

The type of embolic material used was at the discretion of the interventional radiologist, and in few patients materials were used in combination. Microcoils were used in isolation in 69 patients (62%) and in combination with particles in 9 patients (8%). Particles were used in isolation in 33 patients (29%) and gel foam was used in 1 patient (0.9%).

Out of 114 patients 81 were followed up with for one month, 17 for 1 week, and 1 for 1 day while 15 patients were lost to followup. Hence clinical success was measured in only 81 patients.

Total clinical success in the 30-day followup (i.e., complete resolution of signs or symptoms that prompted the embolization procedure) was achieved in 72 of 81 patients (89%). Seven out of 81 patients (11.5%) experienced clinical signs of early rebleeding Table 2. Corresponding vessels were gastroduodenal artery (n = 3), Jejunal branches of SMA (n = 2), and a single case from right ileocolic and left gastric arteries each. In 6 of them repeat angiographies were done, but only one patient showed recurrent jejunal hemorrhage and underwent clinically successful repeat embolization.

The only major complication was early bowel ischemia experienced by 2 (2.4%) of the 81 patients. An elderly male was presented with perrectal bleeding. Arteriography showed abnormal vascularity in the territory of superior rectal artery which was partially embolized using PVA particles. He developed postembolization ischemia along with thrombosis of right common iliac vein. He underwent urgent rectosigmoid resection, while limb ischemia was successfully managed conservatively with oral anticoagulants. Second patient was an elderly male with bleeding duodenal ulcer on endoscopy. His empiric embolization of gastroduodenal artery was done. He presented with symptoms of ischemia after three days and was managed conservatively (Table 3).

After embolization 4 patients underwent surgery 3 for recurrent bleeding and 1 for ischemia. No patient died as a consequence of complications caused by the procedure.

4. Discussion

Our data supports the present literature in demonstrating the efficiency of therapeutic transcatheter embolization in curing acute GI bleeding [5,17]. In a recently published international consensus recommendation, arterial embolization is considered as a surgical alternative in upper GI bleeding management in whom endoscopic haemostatic procedure has failed or who had recurrent bleeding [16]. Similarly arterial embolization is now considered a first-line therapy for patients with severe lower GI bleeding [18].

The first objective of arteriography is to identify the bleeding site which requires the patient to be actively bleeding [19,20]. In few patients even a detailed workup may fail to identify an exact bleeding site, which resulted in the patients undergoing repeated blood transfusions and invasive investigations [20]. In our study 57% of the angiographies were positive. Charbonnet et al. [2] reported a positive rate of 37% while survey by Zuckerman and Prakash [9] found that the rate of positive angiograms can vary from 27% to 77%. Chevallier and colleagues [21] reported very high percentage (93.4%) of positive angiographies which can be explained by the increased frequency of superselective catheter placement in these patients. Nevertheless an angiography may give normal results despite superselective catheterization because even a massive hemorrhage can be intermittent [4]. In these cases a blind or empirical embolization can be done, however, it is associated with an increased chance of rebleeding and ischemia [5,7,8]. To increase the positive rate prior to endoscopy, Tc 99 RBC-tagged scintigraphic evaluation or contrast enhanced CT scans could be helpful in identifying the bleeding vessel [6,10,20].

In our study prior Tc 99 RBC-tagged scintigraphy was performed in 62 patients with acute GI hemorrhage of which 49 (79%) were positive and helped in the identification of bleeding site. Similarly, endoscopy was performed in 93 patients of whom 66 (66%) were positive and guide towards the bleeding vessel.

Endoscopy for the management of gastrointestinal bleed still remains a feasible option whenever possible. Endoscopy can be diagnostic as well as therapeutic especially in upper GI bleed; however, in cases with massive GI bleed visualization becomes challenging and technically difficult. For lower GI bleed the technical success of endoscopy also depends on bowel preparation for optimal visualization. Evaluation of small bowel loops with endoscopy is not possible. For those patients in whom endoscopy was inconclusive or failed due to reasons described therapeutic transcatheter embolization is considered useful option. Surgery is rarely used for treatment of upper GI bleeds; however, it is still utilized for management of lower GI bleeds where endoscopic and transcatheter embolizations have failed or were not available. MDCT angio is considered as the initial radiological investigation as it is a very simple technique. It still requires active bleeding at the time of imaging but may be repeated in case of the first negative examination. A positive MDCT angio can select appropriate patients for rapid targeted embolization. The visualization of active extravasation of IV contrast in the GI tract requires careful attention to technique, including thin collimation, rapid IV contrast administration, and appropriate scan timing. The addition of multiplanar reconstructions (MPR) and 3D imaging is beneficial in identifying the exact source of the bleeding.

The present review, with a technical success rate of 98%, is concurrent with many other reports quoting technical success of more than 90% [4,5,8]. Defreyne and colleagues [22] reported technical success rate of 98%, while in a recent study Tan et al. [4] reported a technical success of 97%. In the literature only few technical failures have been reported, and they were mainly due to difficult vascular anatomy, vascular stenosis, and vascular spasms [15,19]. In few cases intermittent contrast material extravasation can occur which reflects spontaneous bleeding arrests [22]. In such cases, the main arterial trunk should be vigorously studied to determine the point for safe embolization [3,15,22]. Because active extravasation was initially localized, we did not find indication for the use of anticoagulants or fibrinolytics, as recommended by some authors [22,23].

There is a certain risk of complications with reported rates of major ischemic complications range from 0% to 16% [23,24]. Very low rate (2.4%) of bowel ischemia in our study indicates that we delivered the right amount of embolic material in most of the cases. Luc Defreyne in 2001 observed absence of bowel ischemia in 40 patients [22]. Aina and colleagues [24] reviewed 75 consecutive patients who underwent arterial embolization for upper GI bleeding and reported a 99% technical success with a primary clinical success rate of 76%. Only three cases (4%) of ischemia were noted, two involving the duodenum and one the liver [24]. In our study rate of rebleeding was 8.6%. The reported rebleeding rate after therapeutic transcatheter embolization is approximately 33% (range: 9%-66%) [4]. Kwak et al. [5] found rebleeding in 21% of the patients while Wong and colleagues [11] reported high rate of rebleeding (34.4%). A possible explanation for the high rebleeding rate may be coiling the gastroduodenal artery from the celiac axis in these series as gastroduodenal artery can be later fed with collateral branches from the superior mesenteric artery [1,11]. Our study also concurred with these results as 5 (38%) of the patients showed rebleeding from gastroduodenal artery. A sandwich technique can be used in these cases in which the gastroduodenal artery was coiled in a distal-to-proximal manner [1,15]. Similarly inflammatory or ischemic reactions after embolization can trigger vasodilatation of the intramural collaterals and early rebleeding [12].

Our study had certain limitations, including the fact that it was a retrospective analysis, and the refinement and clinical validation of angiographic embolization require a prospective study. Secondly series of patients were enrolled from a single institution, and the cause of bleeding was not known in all cases.

In conclusion, therapeutic transcatheter embolization for the treatment of acute gastrointestinal hemorrhage is highly successful and relatively safe procedure with high technical and clinical success rates, and it should be reserved as a treatment option for patients who are high risk for surgery and failed endoscopic and medical management.

http://dx.doi.org/10.1155/2013/604328

Conflict of Interests

The authors do not have any disclosures or conflict of interests that they would like to declare in relation to their paper.

References

[1] K. Palmer, "Acute upper gastrointestinal haemorrhage," British Medical Bulletin, vol. 83, no. 1, pp. 307-324, 2007

[2] P. Charbonnet, J. Toman, L. Buhler et al., "Treatment of gastrointestinal hemorrhage," Abdominal Imaging, vol. 30, no. 6, pp. 719-726, 2005.

[3] B. J. D'Othee, P. Surapaneni, D. Rabkin, I. Nasser, and M. Clouse, "Microcoil embolization for acute lower gastrointestinal bleeding," CardioVascular and Interventional Radiology, vol. 29, no. 1, pp. 49-58, 2006.

[4] K.-K. Tan, D. Wong, and R. Sim, "Superselective embolization for lower gastrointestinal hemorrhage: an institutional review over 7 years," World Journal of Surgery, vol. 32, no. 12, pp. 2707-2715, 2008.

[5] H.-S. Kwak, Y.-M. Han, and S.-T. Lee, "The clinical outcomes of transcatheter microcoil embolization in patients with active lower gastrointestinal bleeding in the small bowel," Korean Journal of Radiology, vol. 10, no. 4, pp. 391-397, 2009.

[6] Y. Geffroy, M. H. Rodallec, I. Boulay-Coletta, M.-C. Julles, C. Ridereau-Zins, and M. Zins, "Multidetector CT angiography in acute gastrointestinal bleeding: why, when, and how," Radiographics, vol. 31, no. 3, pp. E1-E12, 2011.

[7] M. P. Cherian, P. Mehta, T. M. Kalyanpur, S. S. Hedgire, and K. S. Narsinghpura, "Arterial interventions in gastrointestinal bleeding," Seminars in Interventional Radiology, vol. 26, no. 3, pp. 184-195, 2009.

[8] R. Sheth, V. Someshwar, and G. Warawdekar, "Treatment of acute lower gastrointestinal hemorrhage by superselective transcatheter embolization," Indian Journal of Gastroenterology, vol. 25, no. 6, pp. 290-294, 2006.

[9] G. R. Zuckerman and C. Prakash, "Acute lower intestinal bleeding. Part I: clinical presentation and diagnosis," Gastrointestinal Endoscopy, vol. 48, no. 6, pp. 606-616, 1998.

[10] L. Fisher, M. Lee Krinsky, M. A. Anderson et al., "The role of endoscopy in the management of obscure GI bleeding," Gastrointestinal Endoscopy, vol. 72, no. 3, pp. 471-479, 2010.

[11] T. C. L. Wong, K.-T. Wong, P. W. Y. Chiu et al., "A comparison of angiographic embolization with surgery after failed endoscopic hemostasis to bleeding peptic ulcers," Gastrointestinal Endoscopy, vol. 73, no. 5, pp. 900-908, 2011.

[12] M. Miller Jr. and T. P. Smith, "Angiographic diagnosis and endovascular management of nonvariceal gastrointestinal hemorrhage," Gastroenterology Clinics of North America, vol. 34, no. 4, pp. 735-752, 2005.

[13] M. Nusbaum and S. Baum, "Radiographic demonstration of unknown sites of gastrointestinal bleeding," Surgical forum, vol. 14, pp. 374-375, 1963.

[14] J. Rosch, C. T. Dotter, and M. J. Brown, "Selective arterial embolization. A new method for control of acute gastrointestinal bleeding," Radiology, vol. 102, no. 2, pp. 303-306, 1972.

[15] S. Mirsadraee, P. Tirukonda, A. Nicholson, S. M. Everett, and 5. J. McPherson, "Embolization for non-variceal upper gastrointestinal tract haemorrhage: a systematic review," Clinical Radiology, vol. 66, no. 6, pp. 500-509, 2011.

[16] J. F. Angle, N. H. Siddiqi, M. J. Wallace et al., "Quality improvement guidelines for percutaneous transcatheter embolization: society of interventional radiology standards of practice committee," Journal of Vascular and Interventional Radiology, vol. 21, no. 10, pp. 1479-1486, 2010.

[17] R. Kickuth, H. Rattunde, J. Gschossmann, D. Inderbitzin, K. Ludwig, and J. Triller, "Acute lower gastrointestinal hemorrhage: minimally invasive management with microcatheter embolization," Journal of Vascular and Interventional Radiology, vol. 19, no. 9, pp. 1289-1296, 2008.

[18] A. N. Barkun, M. Bardou, E. J. Kuipers et al., "International consensus recommendations on the management of patients with nonvariceal upper gastrointestinal bleeding," Annals of Internal Medicine, vol. 152, no. 2, pp. 101-113, 2010.

[19] R. Loffroy, P. Rao, S. Ota, M. De Lin, B.-K. Kwak, and J.-F. Geschwind, "Embolization of acute nonvariceal upper gastrointestinal hemorrhage resistant to endoscopic treatment: results and predictors of recurrent bleeding," CardioVascular and Interventional Radiology, vol. 33, no. 6, pp. 1088-1100, 2010.

[20] S. F. Kerr and S. Puppala, "Acute gastrointestinal haemorrhage: the role of the radiologist," Postgraduate Medical Journal, vol. 87, no. 1027, pp. 362-368, 2011.

[21] P. Chevallier, S. Novellas, G. Vanbiervliet et al., "Transcatheter embolization for endoscopically unmanageable acute nonvariceal upper gastrointestinal hemorrhage," Journal de Radiologie, vol. 88, no. 2, pp. 251-258, 2007.

[22] L. Defreyne, P. Vanlangenhove, M. De Vos et al., "Embolization as a first approach with endoscopically unmanageable acute nonvariceal gastrointestinal hemorrhage," Radiology, vol. 218, no. 3, pp. 739-748, 2001.

[23] G. A. Poultsides, C. J. Kim, R. Orlando III, G. Peros, M. J. Hallisey, and P. V. Vignati, "Angiographic embolization for gastroduodenal hemorrhage: safety, efficacy, and predictors of outcome," Archives of Surgery, vol. 143, no. 5, pp. 457-461, 2008.

[24] R. Aina, V. L. Oliva, E. Therasse et al., "Arterial embolotherapy for upper gastrointestinal hemorrhage: outcome assessment," Journal of Vascular and Interventional Radiology, vol. 12, no. 2, pp. 195-200, 2001.

Muhammad Ali, Tanveer Ul Haq, Basit Salam, Madiha Beg, Raza Sayani, and Muhammad Azeemuddin

Radiology Department, Aga Khan University Hospital, Stadium Road, RO. Box 3500, Karachi 74800, Pakistan

Correspondence should be addressed to Raza Sayani; sayani_raza@yahoo.com

Received 23 January 2013; Revised 26 April 2013; Accepted 29 April 2013

Academic Editor: Sotirios Bisdas

Table 1: Demographics and characteristics of 200 patients who had
mesenteric angiogram for acute GI hemorrhage.

Characteristics             Results

Angiographic sensitivity    114 (57%)
Median age                   55 years
Gender
  Male                      134 (76%)
  Female                     66 (33%)
Presenting complaints
  Hematemesis                28 (14%)
  Melena                     66 (33%)
  Perrectal bleeding        106 (53%)
Prior investigation
  Upper GI endoscopy         93
    Positive                 66 (71%)
    Negative                 27 (29%)
  RBC-tagged scintigraphy    62
    Positive                 49 (79%)
    Negative                 13 (21%)
Prior blood transfusion     145 (72.5%)
Coagulation profile
  Normal                    124 (62%)
  Deranged                   76 (38%)
Comorbid
  No comorbid                44 (22%)
  Chronic liver disease      24 (12%)
  Hypertension               22 (11%)
  Diabetes mellitus          15 (7.5%)
  Chronic renal failure      20 (10%)
  Malignancy                 21 (10.5%)
  Trauma                     10 (5.0%)
  Infectious diseases        28 (14%)
  Misc                       16 (8.0%)

Table 2: Characteristics of 81 patients after one-month followup.

Characteristics                 Results

Clinical success                72 (89%)

Complication (bowel ischemia)   02 (2.4%)

Rebleeding                      07 (8.6%)

Repeat procedure                06 (74%)

Surgical management             04 (4.9%)

Table 3: Characteristics of 114 patients who reveal and underwent
therapeutic embolization.

Characteristics             Results

Technical success           112 (98%)

Site

  Upper GI hemorrhage        47 (41%)

  Lower GI hemorrhage        67 (59%)

Embolization

  Proximal (selective)       21 (19%)

  Distal (superselective)    91 (81%)

Arteries embolized

  Gastroduodenal artery      36 (32%)

  Ileocolic artery           28 (25%)

  Right colic artery         12 (11%)

  Jejunal branches of SMA    10 (8.9%)

  Left gastric artery        09 (8.0%)

  Superior rectal artery     07 (6.2%)

  Ileal branches of SMA      05 (4.4%)

  Left colic artery          04 (3.6%)

  Middle colic artery        01 (0.9%)

Embolization material

  Microcoils                 69 (62%)

  PVA particles              33 (29%)

  PVA with microcoils        09 (8.0%)

  Gel foam                   01 (0.9%)
COPYRIGHT 2013 Hindawi Limited
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2013 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Clinical Study
Author:Ali, Muhammad; Haq, Tanveer Ul; Salam, Basit; Beg, Madiha; Sayani, Raza; Azeemuddin, Muhammad
Publication:Radiology Research and Practice
Article Type:Report
Date:Jan 1, 2013
Words:3974
Previous Article:Geriatric chest imaging: when and how to image the elderly lung, age-related changes, and common pathologies.
Next Article:Lumbar facet joint arthritis is associated with more coronal orientation of the facet joints at the upper lumbar spine.
Topics:

Terms of use | Privacy policy | Copyright © 2022 Farlex, Inc. | Feedback | For webmasters |