Printer Friendly

Solvent effects on the electrochemical behavior of TAPD-based redox-responsive probes for cadmium(II).

1. Introduction

Metallic ions are widely present in the biological systems and play many important roles [1,2]. Some others are toxic but are tolerated at low levels such as nickel or cobalt because of their interventions in some biological processes [3]. Other cations can cause major health damage if they are present even in trace amounts such lead(II) and cadmium(II) [4, 5]. Indeed, lead is known to cause saturnism when it is present at high concentration in biological medium [6, 7]. Cadmium has been reported to block calcium channels in sensory neurons and prevents regular central system functioning [8]. Many researchers have been consequently devoted to the development of methods for the determination of these cations.

In living organisms, biological receptors like those found in enzymes or neurons bind selectively to a cation to achieve some goals most of the times in reversible processes. Contrarily, most of the synthetic receptors do not work that way; they tightly bind to cations in nonreversible processes [9]. Only few attempts have been directed at the elaboration of reversible chemosensors useful for the detection and eventually the delivery cations such as calcium ions when they are photochemically or electrochemically triggered [10, 11]. The first class of chemosensors relies on chromogenic guest-responsive transducers whose properties change when they are linked to cations. The second class of chemosensors depends on reversible electrochemical transducers to achieve the chelation of ions in a chemical reversible manner.

In the last two decades, electroactive chemosensors have been built by using reversible systems. The detection or release of guest ions is monitored through the modification of the electrochemical features of redox centers. For instance, Pearson and Hwang were pioneers in the field and reported many TAPD-based chemosensors formed by crown ethers as ionophore sites and phenylenediamine moiety as a transducer capable of detection of alkaline or alkaline earth cations [12]. In a similar way, Sibert and coworkers prepared chemosensors containing crown thiaethers as hosting sites to selectively recognize noble and heavy-metal ions such as platinum(II) and mercury(II) [13, 14]. Recently, our group reported the preparation of new chemosensors which are able to chelate metal ions in solution [15,16]. Bhattacharyya et al. also recently reported the preparation and the electrochemical study of a novel water-soluble redox active and selective chelator for calcium based on organometallic derivative [17]. Thus, as chelation took place in solution, the thermodynamics and kinetics of the electron transfer are solvent-dependent and so should be the chemosensor electrochemical features prior to and after the cadmium(II) chelation process. For example, Pirson and Huyskens have studied the effect of the solvent in the complexation of same anions and cations by substituted benzoic acid ligands [18]. They concluded that the acetonitrile and nitrobenzene had influence on the stability constants of the formed complexes. Besides, Coetzee and Sharpe reported the interaction between acetonitrile and anions or cations [19]. Moreover, Wang et al. [20] demonstrated the influence of various organic solvents on the electrochemical activity of redox moiety. To our best knowledge there are no reports on the study of complexation dependence on the solvent for TAPD systems. This work is intended to fill in this gap.

The aim of this work is to study the solvent effects on the electrochemical behavior of 1 and 2 (Figure 1) during the chelation of cadmium(II) following several works devoted to the development of TAPD-based chemosensors for bivalent cations which have been mostly studied in acetonitrile. The electrochemical investigations were conducted by means of cyclic voltammetry (CV) in acetonitrile (ACN), dimethylformamide (DMF), propylene carbonate (PC), or nitromethane (NM), solvents commonly used for electrochemical measurements, aiming to draw some conclusions in the solvent effects on the chemosensors chelating ability.

2. Materials and Methods

2.1. Reagents and Chemicals. 4-Dimethylaminoaniline (97%), sodium cyanoborohydride (95%), sodium bicarbonate ([greater than or equal to] 95%), glacial acetic acid ([greater than or equal to] 99%), cadmium perchlorate hydrate [(Cd(Cl[O.sub.4]).sub.2] x x[H.sub.2]O), tetrabutylammonium tetrafluoroborate (TBAB[F.sub.4], [greater than or equal to] 99%), triflic acid ([greater than or equal to] 99%), and HPLC grade methanol were purchased from Sigma-Aldrich and used without further purification. Aldehydes (furfural, 99%, and thiophene-2-carboxaldehyde, 98%) were freshly distilled before use. PC and NM were purchased from Merck and were distilled and stored in dark; AnhydroScan ACN, DMF, and dichloromethane were purchased, respectively, from LabScan and Sigma-Aldrich and used as received without further purification. A stock solution of cadmium 0.1 M is prepared by dissolving the corresponding amount in acetonitrile.

2.2. Apparatus. Proton and carbon 13 NMR spectra were recorded on a Bruker Avance 300 MHz apparatus in CD[Cl.sub.3]. Chemical shifts are given in ppm relative to TMS as internal reference. IR spectra were measured on a Perkin Elmer ATR Alpha spectrophotometer. The electrochemical experiments were conducted in the corresponding solvent containing 0.1 M [TBABF.sub.4] as supporting electrolyte, at ambient temperature and at a scan rate of 0.1 V [s.sup.-1]. A Radiometer Analytical POL-150 with MED-150 stand-controlled three-electrode glass cell fitted with a carbon glassy disk as a working electrode (3 mm-diameters), a platinum wire as a counter electrode, and an SCE (3 M KCl) electrode as a reference electrode was used for the electrochemical measurements. Data acquisition was performed with TraceMaster 5 software for CV experiments and treated using Kaleidagraph 4.0 software package. The working electrode was polished using 0.3 [micro]m slurry of alumina at the beginning of each experiment.

2.3. Preparation and Physicochemical Characterization of Chemosensors. The compounds were prepared according to published procedure [15,16]. The reaction was performed in round bottom flask maintained under argon atmosphere at room temperature and shielded from the light with an aluminum foil. Briefly, compound 1 (2) was obtained by mixing 2.0 mmol of 4-dimethylaminoaniline, 8.0 mmol of furfural (4.0 mmol of furfural and 4.0 mmol of thiophene-2-carboxaldehyde), and 10.0 mmol of acetic acid in methanol (50 mL). After 12 h stirring, 2.0 mmol of sodium cyanoborohydride was added and stirring was kept for a further 4 h. The mixture was quenched with 50 mL of a saturated sodium bicarbonate solution and extracted twice with 20 mL of dichloromethane. The organic phase was washed twice with 10 mL of distilled water, dried over magnesium sulfate, and evaporated to dryness (Scheme 1).

The oily brown residue was purified on silica gel eluted by 30:70 ethyl acetate/cyclohexane leading to solid product which was characterized by [sup.1]H, [sup.13]C NMR, and infrared spectroscopy. The characteristics are summarized below.

[FORMULA NOT REPRODUCIBLE IN ASCII]

Compound 1 ([C.sub.18][H.sub.20][N.sub.2][O.sub.2]): yield: 61%; mp: 49-51[degrees]C; [sup.1]H NMR (CD[Cl.sub.3], 300 MHz) [delta]/ppm: 2.75(s, 6H, C[H.sub.3]), 4.27(s, 4H, C[H.sub.2]), 6.03 (d, 2H, furan, [sup.3][J.sub.H-H] = 3 Hz), 6.19 (dd, 2H, furan, [sup.3][J.sub.H-H] = 3 Hz), 6.65 (d, 2H, [sup.3][J.sub.H-H] = 9 Hz, C[H.sub.arom]), 6.80 (d, 2H, [sup.3][J.sub.H-H] = 9 Hz, C[H.sub.arom]), 7.23 (s, 2H, furan); [sup.13]C NMR (CD[Cl.sub.3],75.5 MHz) d/ppm: 40.7,474,106.7,109.1,113.9, 115.9,140.2,140.7,143.5,151.6; IR [v.sub.max]/[cm.sup.-1]: 2964 (CH), 2896 (CH), 1514 (C=C), 1250 (C-N), 1070 (C-C), 1056 (C-C), 810 (C-O).

Compound 2 ([C.sub.18][H.sub.20][N.sub.2]OS): yield: 65%; mp: 58-59[degrees]C; [sup.1]H NMR (CD[Cl.sub.3], 300 MHz) [delta]/ppm: 2.77 (m, 6H, C[H.sub.3]), 4.27 (s, 2H, C[H.sub.2], furan), 4.48 (s, 2H, C[H.sub.2], thiophene), 6.06 (d, 2H, [sup.3][J.sub.H-H] = 3 Hz, furan), 6.21 (d, 2H, [sup.3][J.sub.H-H] = 3 Hz, furan), 6.65 (d, 2H, [sup.3][J.sub.H-H] = 10 Hz, C[H.sub.arom].), 6.80 (d, 2H, [sup.3][J.sub.H-H] = 10 Hz, C[H.sub.arom].), 708 (d, 1H, [sup.3][J.sub.H-H] = 2 Hz, C[H.sub.arom.], 7.17 (s, 1H, furan), 7.17 (m, 1H, furan); [sup.13]C NMR (CD[Cl.sub.3], 75.1MHz) [delta]/ppm: 41.8, 48.2, 50.7, 107.9, 110.2, 114.9, 117.3, 124.4, 125.2, 126.5, 141.0, 141.8; [v.sub.max]/[cm.sup.-1]: IR3663 (CH), 2972 (CH), 1514 (C=C), 1393 (C-N), 1248 (C-C), 809 (C-O), 720 (C-S).

3. Results and Discussion

3.1. Electrochemistry of the Uncoordinated Chemosensors. CVs of 1 and 2 investigated in the different solvents except in DMF exhibit two oxidation peaks. This electrochemical behavior is similar to that reported for tetramethylated para-phenylenediamine (TMPD) [21] which is generally attributed, respectively, to the formation of a [TAPD.sup.*+] radical-cation and [TAPD.sup.2+] (Figures 2(a) and 2(b)).

When the potential reverse sweep is poised to approximately 0.5 V, the first monoelectronic peak is reversible (Figure 3) and this is due to the stability of the generated radical-cation allowing more accurate determination of [i.sub.pc]. The second oxidation peak is irreversible probably due to the deactivation of the generated dication, which is highly reactive, by the nucleophilic impurities present in the medium. In DMF, this peak involves also the oxidation of furan and/or thiophene ring. Table 1 summarized the thermodynamic data of compounds 1 and 2. As it appears in this table, one can observe that the [i.sub.pc]/[i.sub.pa] ratio is close to the unity confirming the reversibility of the electron transfer of the first peak [22]. Moreover, at the same concentration, the intensity of the oxidation peak current for compound 1 and compound 2 decreases from ACN to PC. These results, in agreement with those reported in the literature, could be explained by using the Randles-Sevcik and Stokes-Einstein equations which correlate the peak current upon the solvent viscosity [23, 24]. Thus, viscosity increase from ACN to PC leads to a decrease in the intensity of the peak current. Moreover, the current intensity is dependent on the diffusion coefficient of the compounds in each solvent which could explain the changes in current intensities [25].

Additionally, one can see in Table 1 that the oxidation potential peaks of the two compounds also depend on the solvent in which the studies were carried out. For instance, in the case of 1 (2), the difference of the oxidation peak potentials which could be observed comparatively in any two different solvents is at most 40 mV (50 mV). However, one can note that compounds 1 and 2 can be more easily oxidized in NM and PC than in ACN or DMF. Thus, the oxidation potential is close to 358 mV for compound 1 in ACN while in PC it is only 315 mV. This behavior could be due to donor-acceptor interaction between the studied components and the solvent [26]. Participation of liquid junction potential could be involved. For any couple of these solvents it is comprised between 0 and 10 mV [27].

The study of the scan rate effect carried out on the first oxidation peak shows that the current intensity increases with the scan rate in the range of 0.05-0.5 [Vs.sup.-1]. The linear plot of the logarithm of the first peak current as a function of logarithm of scan rate is close to 0.5 indicating a diffusion-controlled electron reaction [28].

3.2. Electrochemistry of the Chemosensors in Presence of Cadmium. CVs recorded in presence of 0.5 equivalent of Cd(II) show that chemosensors are capable of binding to this ion except in DMF. Indeed, it is noticeable on the curves of Figures 4(a) and 4(b) that the addition of 0.5 equivalent of Cd(II) leads to a total disappearance of the two oxidation peaks characteristic of the uncoordinated chemosensors. This behavior corresponds mostly to a chemical interaction in solution between chemosensors and Cd(II) as it has been previously reported [12-17]. Indeed, after the addition of cadmium cation, the lone pair of electrons on the nitrogen is involved in the complexation reaction with the metal leading to the disappearance of the two oxidation peaks and a new one is observed at more anodic potential which is different from that of the aromatic ring of thiophene or furan. In our point of view and in comparison with works reported by Amatore group [11, 17] and Sahli et al. [15, 16], this peak is probably due to the oxidation of the complex 1-Cd(II) or 2-Cd(II). When the scanning is realized at more anodic potential in absence of Cd(II), one can observe a different oxidation peak, which is irreversible, corresponding to the oxidation of furan or thiophene ring (dotted voltammograms) [29, 30].

Additionally, temporal monitoring of the Cd(II) chelation reaction of the chemosensors revealed that the reaction is slow leading to complete disappearance of the chemosensors' signals after 45-60 min even if 1.0 equivalent of Cd(II) is added. When 4 to 10% molar TfOH is added, this cation chelation is accelerated and a purple coloration of the solution is noticed. On the other hand, one can observe that the addition of small amounts of TfOH does not affect the electrochemical features of the chemosensors (figure not shown); since TfOH is a weak acid in organic solvents (p[K.sub.a] = 0.7 in ACN) [31], the protonated amounts of 1 and 2 should remain very low and the oxidation currents are unaltered. Besides, the addition of an increasing quantity of acid (up to 20%) does not affect the electrochemical behavior of TAPD compounds, nor are the potentials or the currents of the peaks altered. The presence of the acid seems indeed to be necessary to achieve rapidly the complexation reaction. One can hypothesize that the protons from TfOH protonate the aromatic nitrogen bearing the two other chelating rings inducing a conformational change, which is thermodynamically unfavoured, followed by a proton-metal exchange giving more rapidly the [[Cd[(L).sub.2]].sup.2+] complexes. In both cases, at least a nitrogen atom is protonated (Scheme 2) 32].

[FORMULA NOT REPRODUCIBLE IN ASCII]

During the reverse scan, two cathodic peaks are visible in ACN, NM, or PC corresponding to the two-stage reduction of dication peaks. Indeed, due to the positive charges on compounds 1 and 2 after the anodic electron transfer, one can suggest the release of Cd(II) in solution from the inner sphere of the complex by electrostatic repulsion between the positive charges on the phenylenediamine moiety and on Cd(II) leading to [1.sup.2+] and [2.sup.2+] which are reducible during the reverse potential scan. The dication reduction gives radical-cation [1.sup.*+] or [2.sup.*+] leading to neutral species after a second electron transfer. Moreover, the reduction of [1.sup.*+]/[2.sup.*+] into the neutral form occurs at higher potentials than of the uncoordinated chemosensors because the recomplexation reaction displaces the interfacial equilibrium, facilitating thus the electron transfer [33]. The chelating abilities of the chemosensors are thus restored. Furthermore, the cathodic current increase may be due to the introduction of perchlorate ions; that is, cadmium perchlorate was used, having a more stabilizing effect on the organic dication than tetrafluoroborate from the supporting electrolyte. On the other hand, the gradual addition of Cd(II) to solutions of the chemosensors showed that the current of the two oxidation peaks of ligand dropped gradually and completely vanished when 0.5 equivalent of the cation is added suggesting a total complexation of the ligands so it can be concluded that the complex stoichiometry is 1: 2.

When the chelation of Cd(II) by the chemosensors is attempted in DMF (Figure 5), the voltammetric curves showed a decreasing of the current intensity and exhibited also a slight shift of oxidation peak potential in the presence of 0.5 equivalent of Cd(II) toward anodic value suggesting a chemosensor-cation interaction and a solvent-cation interaction, respectively. These interactions remain weak even when 1.0 equivalent of Cd(II) is added. These relatively weak potential shifts (125 mV for 1 and 48 mV for 2) suggest a possible competition between the ligand and DMF which is a good electron-donating ligand for Cd(II). This behavior is in agreement with the studies by Jorge and Stradiotto [34], who reported that DMF is able to complex Sn(II) by removal of ACN molecules. The addition of a small amount of acid to the Cd/ligand in DMF solution does not improve the complexation process.

3.3. Reaction Coupling Efficiency. Depending on the solvent and the chemosensor, potentials of the first oxidation peak of ligands 1 and 2 and the one corresponding to the complex oxidation are reported in Table 2. As shown in Table 2, one can remark that except in DMF the shift of the potential after the complexation varies from ca. 500 to ca. 900 mV and can be correlated to the stability of the formed complex. These observations are in agreement with works of Beer et al. showing that the stability of the complexes is proportional to the shifts of oxidation potentials of various ferrocene-based ligands [35]. Due to the difficulty of determining [E.sup.3.sub.1/2] since the third peak is irreversible, the values of [DELTA][E.sub.1/2] = [E.sup.3.sub.1/2] - [E.sup.1.sub.1/2] should stay very close to [DELTA][E.sub.p] = [E.sup.3.sub.p] - [E.sup.1.sub.p] as it is for the first and the second peaks for both compounds. Indeed, the peak potential depends on the electron transfer rate constant and following chemical reactions [36]. This system is considered electrochemically reversible at 0.1 V/s. This is demonstrated by a low peak to peak separation (less than 111 mV). Degradation rate after the second electron transfer was not determined precisely so [DELTA][E.sub.1/2] cannot be deduced directly from [DELTA][E.sub.p]. However, we can infer that [DELTA][E.sub.1/2] is equal to [DELTA][E.sub.p] since the oxidation potential is lowered when chemical reaction displaces the electrochemical equilibrium.

Since the [E.sup.3.sub.p] peak of oxidation corresponds to the oxidation of the complexes [[Cd[(L).sub.2]].sup.2+] (L = 1 or 2), to the radical-cation and subsequent dissociation of the radical-cation complex [[Cd[(L*).sub.2]].sup.2+] into Cd(II) and free oxidized forms of 1 or 2, due to the electrostatic repulsion between these two positively charged species [15, 16]. At this potential, the released radical-cation undergoes a second one-electron transfer to its dication according to Scheme 3.

Beer and coworkers described the reaction coupling efficiency (RCE) as the ratio of [K.sub.ox]/[K.sub.red] which are, respectively, the complex stability constants for a given ligand in its oxidized and reduced forms. The RCE can be easily determined from corresponding difference between the oxidation potentials of the uncoordinated and coordinated host and is a very useful tool to evaluate and compare the redox-active ligands efficiency toward metal chelation. This relation can be reasonably applied to determine the RCE [35-37] since one-electron exchange is sufficient for the dissociation of the complex as previously reported in the case of ferrocene-based chemosensors [38-40]. Very high values of RCE imply that the reaction is complete, which is observed for ACN, NM, and PC and not chelation attempted in DMF. In addition, on can note through this table and the results obtained from cyclic voltammetry investigations that chemosensor 1 binds more efficiently to cadmium than chemosensor 2, probably because compound 1 has two more donating sites than one sulfur and one oxygen atoms in compound 2.

4. Conclusions

Cyclic voltammetry of two new chemosensors investigated in ACN, NM, PC, and DMF showed that these compounds exhibit two oxidation waves corresponding to a 2-electron transfer from the phenylenediamine moiety. It was also demonstrated using CV that these compounds constituted good ligands for cadmium(II) in solution and the affinity toward this metal depends strongly of the nature of solvent used, and complexes were formed in 1:2 stoichiometry. Moreover, it was shown that this complexation reaction starts after 45 to 60 min under open circuit conditions due to electrogenerated protons but it can be tremendously accelerated by addition of catalytic amount of TfOH. RCE values showed that ligand binds tightly to the cation except in DMF and the complexes are more stable with ligand 1 than with 2.

http://dx.doi.org/10.1155/2014/305721

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgments

The authors gratefully acknowledge the MHESR for the financial support through LR99ES15 program and the African Network of Electroanalytical Chemists ANEC/ISP for the strengthening south to south scientific collaboration. Issa Tapsoba would like to acknowledge TWAS, the Academy of Sciences for the Developing World, for the support provided by TWAS Visiting Scientist Program.

References

[1] H. Sigel and A. Siegel, Metal Ions in Biological System: Compendium on Magnesium and Its Role in Biology, Nutrition, and Physiology, vol. 26, Marcel Dekker, NewYork, NY, USA, 1990.

[2] H. Sigel and A. Siegel, Metal Ions in Biological Systems: Volume 15: Zinc and Its Role in Biology and Nutrition, Marcel Dekker, New York, NY, USA, 1983.

[3] H. Sigel and A. Siegel, Metal Ions in Biological System: Nickel and Its Role in Biology, vol. 23, Marcel Dekker, New York, NY, USA, 1988.

[4] H. Needleman, "Lead poisoning," Annual Review of Medicine, vol. 55, pp. 209-222, 2004.

[5] L. Chandran and R. Cataldo, "Lead poisoning: basics and new developments," Pediatrics in Review, vol. 31, no. 10, pp. 399-406, 2010.

[6] J. A. Staessen, H. A. Roels, D. Emelianov et al., "Environmental exposure to cadmium, forearm bone density, and risk of fractures: prospective population study," The Lancet, vol. 353, no. 9159, pp. 1140-1144, 1999.

[7] I. Tapsoba, S. Arbault, P. Walter, and C. Amatore, "Finding out Egyptian Gods' secret using analytical chemistry: biomedical properties of Egyptian black makeup revealed by amperometry at single cells," Analytical Chemistry, vol. 82, no. 2, pp. 457-460, 2010.

[8] D. Swandulla and C. M. Armstrong, "Calcium channel block by cadmium in chicken sensory neurons," Proceedings of the National Academy of Sciences of the United States of America, vol. 86, no. 5, pp. 1736-1740, 1989.

[9] H. M. Kim, M. S. Seo, M. J. An et al., "Two-photon fluorescent probes for intracellular free zinc ions in living tissue," Angewandte Chemie International Edition, vol. 47, no. 28, pp. 5167-5170, 2008.

[10] M. M. Martin, P. Plaza, Y. H. Meyer et al., "Steady-state and picosecond spectroscopy of Li+ or Ca2+ complexes with a crowned merocyanine. Reversible photorelease of cations," The Journal of Physical Chemistry, vol. 100, no. 17, pp. 6879-6888, 1996.

[11] C. Amatore, D. Genovese, E. Maisonhaute, N. Raouafi, and B. Schollhorn, "Electrochemically driven release of picomole amounts of calcium ions with temporal and spatial resolution," Angewandte Chemie, vol. 47, no. 28, pp. 5211-5214, 2008.

[12] A. J. Pearson and J.-J. Hwang, "Crown-annelated P-phenylenediamine derivatives as electrochemical and fluorescenceresponsive chemosensors: Cyclic voltammetry studies," Tetrahedron Letters, vol. 42, no. 21, pp. 3541-3543, 2001.

[13] J. W. Sibert, P. B. Forshee, and V. Lynch, "Wurster's thiacrown ethers: synthesis, properties, and Pt(II)-coordination chemistry," Inorganic Chemistry, vol. 44, no. 23, pp. 8602-8609, 2005.

[14] J. W. Sibert, P. B. Forshee, and V. Lynch, "Electron transfer vs coordination chemistry: isomer-specific binding of Hgll by an ortho-Wurster's thiacrown ether," Inorganic Chemistry, vol. 45, no. 16, pp. 6108-6110, 2006.

[15] R. Sahli, N. Raouafi, E. Maisonhaute, K. Boujlel, and B. Schollhorn, "Thiophene-based electrochemically active probes for selective calcium detection," Electrochimica Acta, vol. 63, pp. 228-231, 2012.

[16] R. Sahli, N. Raouafi, K. Boujlel, E. Maisonhaute, B. Schollhorn, and C. Amatore, "Electrochemically active phenylenediamine probes for transition metal cation detection," New Journal of Chemistry, vol. 35, no. 3, pp. 709-715, 2011.

[17] K. X. Bhattacharyya, L. Boubekeur-Lecaque, I. Tapsoba, E. Maisonhaute, B. Schollhorn, and C. Amatore, "An organometallic derivative of a BAPTA ligand: towards electrochemically controlled cation release in biocompatible media," Chemical Communications, vol. 47, no. 18, pp. 5199-5201, 2011.

[18] D. J. Pirson and P. L. Huyskens, "Specific solvent effects on the complexation of anions by ligands," Journal of Solution Chemistry, vol. 3, no. 7, pp. 503-514, 1974.

[19] J. F. Coetzee and W. R. Sharpe, "Solute-solvent interactions. VII. Proton magnetic resonance and infrared study of ion solvation in dipolar aprotic solvents," Journal of Solution Chemistry, vol. 1, no. 1, pp. 77-91, 1972.

[20] X.-J. Wang, L. Wang, J.-J. Wang, and T. Chen, "Solvent effects on electrochemical behavior of poly(ferrocenylsilane) films," Electrochimica Acta, vol. 52, no. 12, pp. 3941-3949, 2007

[21] H. Fernandez and M. A. Zon, "Solvent effects on the kinetics of heterogeneous electron transfer processes. The TMPD/[TMPD.sup.+] redox couple," Journal of Electroanalytical Chemistry, vol. 332, no. 1-2, pp. 237-255, 1992.

[22] F. M. Marken, A. Neudeck, and A. M. Bond, Electroanalytical Methods: Guide to Experiments and Applications, Springer, Berlin, Germany, 2010.

[23] J. E. B. Randles, "A cathode ray polarograph. Part II.--The

current-voltage curves," Transactions of the Faraday Society, vol. 44, pp. 327-338, 1948.

[24] J. S. Long, D. S. Silvester, A. S. Barnes et al., "Oxidation of several p-phenylenediamines in room temperature ionic liquids: estimation of transport and electrode kinetic parameters," The Journal of Physical Chemistry C, vol. 112, no. 17, pp. 6993-7000, 2008.

[25] N. G. Tsierkezos, "Cyclic voltammetric studies of ferrocene in nonaqueous solvents in the temperature range from 248.15 to 298.15 K," Journal of Solution Chemistry, vol. 36, no. 3, pp. 289-302, 2007.

[26] D. W. Hall and C. D. Russell, "Substituent effects in the chronopotentiometric oxidation of ferrocene derivatives. Internal solvation of certain substituted ferricenium ions," Journal of the American Chemical Society, vol. 89, no. 10, pp. 2316-2322, 1967.

[27] G. Gritzner and J. Kuta, "Recommendations on reporting electrode potentials in nonaqueous solvents," Pure and Applied Chemistry, vol. 54, pp. 1527-1532, 1982.

[28] R. G. Compton and C. E. Banks, Understanding Voltammetry, World Scientific, London, UK, 2007

[29] B. Demirboga and A. M. Onal, "Electrochemical polymerization of furan and 2-methylfuran," Synthetic Metals, vol. 99, no. 3, pp. 237-242, 1999.

[30] M. Ates, "Electrochemical impedance spectroscopic study of electrocoated polythiophene and poly(2-methyl thiophene) on carbon fiber microelectrode for microcapacitor," International Journal of Electrochemical Science, vol. 4, no. 7, pp. 980-992, 2009.

[31] E. Raamat, K. Kaupmees, G. Ovsjannikov et al., "Acidities of strong neutral Bronsted acids in different media," Journal of Physical Organic Chemistry, vol. 26, no. 2, pp. 162-170, 2012.

[32] A. S. Khamidullina, I. V. Vakulin, R. F. Talipov, and I. S. Shepelevich, "Structure effects of the protonated lincomycin molecule on the mechanism of its complexation with organic compounds," Journal of Structural Chemistry, vol. 46, no. 6, pp. 985-990, 2005.

[33] G. Chaka and A. Bakac, "Two-electron oxidation of N,N,N, N-tetramethylphenylenediamine with a chromium(v) salen complex," Dalton Transactions, no. 2, pp. 318-321, 2009.

[34] S. M. A. Jorge and N. R. Stradiotto, "Complexation studies of Sn(II) by N,N-dimethylformamide and free energy of transfer of Sn(II) from acetonitrile to N,N-dimethylformamide," Analytica Chimica Acta, vol. 242, no. 2, pp. 295-298, 1991.

[35] P. D. Beer, P. A. Gale, and G. Z. Chen, "Mechanisms of electrochemical recognition of cations, anions and neutral guest species by redox-active receptor molecules," Coordination Chemistry Reviews, vol. 185-186, pp. 3-36, 1999.

[36] J.-M. Saveant, Elements of Molecular and Biomolecular Electrochemistry: An Electrochemical Approach to Electron Transfer Chemistry, John Wiley & Sons, Hoboken, NJ, USA, 2006.

[37] P. D. Beer, P. A. Gale, and Z. Chen, "Electrochemical Recognition of charged and neutral guest species by redox-active Receptor Molecules," Advances in Physical Organic Chemistry, vol. 31, pp. 1-90, 1999.

[38] V. S. Elanchezhian and M. Kandaswamy, "A ferrocene-based multi-signaling sensor molecule functions as a molecular switch," Inorganic Chemistry Communications, vol. 12, no. 2, pp. 161-165, 2009.

[39] M. Alfonso, A. Tarraga, and P. Molina, "Ferrocene-based multichannel molecular chemosensors with high selectivity and sensitivity for Pb(II) and Hg(II) metal cations," Dalton Transactions, vol. 39, no. 37, pp. 8637-8645, 2010.

[40] P. Molina, A. Tarraga, and A. Caballero, "Ferrocene-based small molecules for multichannel molecular recognition of cations and anions," European Journal of Inorganic Chemistry, no. 22, pp. 3401-3417, 2008.

Rihab Sahli, (1,2) Janet Bahri, (1) Issa Tapsoba, (3) Khaled Boujlel, (1) and Noureddine Raouafi (1)

(1) Laboratoire de Chimie Analytique et Electrochimie, Departement de Chimie, Faculte des Sciences de Tunis, Universite de Tunis El Manar, Campus Universitaire de Tunis El Manar, 2092 Tunis, Tunisia

(2) Laboratoire Methodes et Techniques d'Analyse, Institut National de Recherche et d'Analyse Physico-Chimique, Biotechpole de Sidi-Thabet, 2020 Ariana, Tunisia

(3) Laboratoire de Chimie Analytique, Environnement et Bioorganique (LCAEBio), Departement de Chimie, UFR/SEA, Universite de Ouagadougou, BP 7021, Ouagadougou 03, Burkina Faso

Correspondence should be addressed to Rihab Sahli; rihab.sahli@gmail.com

Received 11 July 2014; Accepted 5 October 2014; Published 25 November 2014

Academic Editor: Emmanuel Maisonhaute

TABLE 1: Thermodynamics data for the first and second peaks: anodic
[E.sub.pa] and cathodic [E.sub.pc] potential values, peaks separation
[DELTA]E,  half/wave potential [E.sub.1/2], and the current ratio
[i.sub.pc]/[i.sub.pa] for compounds 1 and 2 measured in ACN, PC, NM,
and DMF.

      Compound   1st peak of oxidation

                 [E.sub.pa] (a)    [E.sub.pc] (a)

ACN      1             358               259
         2             355               263
PC       1             315               218
         2             327               216
NM       1             330               233
         2             306               204
DMF      1             365               267
         2             370               267

      Compound   1st peak of oxidation

                 [DELTA][E.sub.p] (b)   [E.sub.1/2] (c)

ACN      1                99                  308
         2                92                  309
PC       1                97                  266
         2               111                  271
NM       1                97                  281
         2               102                  255
DMF      1                98                  316
         2               103                  318

      Compound   1st peak of oxidation

                 [i.sub.pc]/[i.sub.pa]    [E.sub.pa] (a)

ACN      1                1.03                  912
         2                1.04                  942
PC       1                0.98                  882
         2                0.99                  918
NM       1                1.02                  947
         2                 1                    922
DMF      1                1.04                  970
         2                0.99                  965

      Compound   2nd peak of oxidation

                 [E.sub.pc] (a)    [DELTA][E.sub.p] (b)

ACN      1             765                 147
         2             775                 167
PC       1             700                 182
         2             735                 183
NM       1             794                 153
         2             753                 169
DMF      1             676                 294
         2             706                 259

      Compound   2nd peak of oxidation

                 [E.sub.1/2] (c)

ACN      1             838
         2             858
PC       1             791
         2             826
NM       1             870
         2             837
DMF      1             823
         2             835

(a) [E.sub.p] measured (mV) versus SCE; [E.sub.pc] are
extracted for curves in Figure 2.

(b) [DELTA][E.sub.p] = [E.sub.pa] - [E.sub.pc].

(c) [E.sub.1/2] = [E.sub.pa] - [DELTA][E.sub.p]/2.

TABLE 2: Potentials of first oxidation peak, [E.sup.1.sub.p], and
complex oxidation peak [E.sup.3.sub.p], [DELTA]E, and the logarithm
of the reaction coupling efficiency (log RCE) for compounds 1 and 2 in
the presence of 0.5 equivalent of [Cd.sup.2+] in ACN, NM, PC, and DMF
containing 0.1 M TBAB[F.sub.4].

    [E.sup.1.sub.p] (a)   [E.sup.3.sub.p] (a)   [DELTA]E (b)   - log
                                                               RCE (c)
                                                    ACN

1           353                  1247               -894        14.9
2           312                   118               -864        14.4

                                                     NM

1           330                  1218               -888        14.8
2           306                  1094               -788        13.1

                                                     PC

1           315                  1188               -873        14.6
2           327                   884               -502         8.4

(a) [E.sub.p] measured (mV) versus SCE.

(b) [DELTA]E = [E.sup.1.sub.p] - [E.sup.3.sub.p].

(c) log RCE = [DELTA]E/60.
COPYRIGHT 2014 COPYRIGHT 2010 SAGE-Hindawi Access to Research
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2014 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Research Article
Author:Sahli, Rihab; Bahri, Janet; Tapsoba, Issa; Boujlel, Khaled; Raouafi, Noureddine
Publication:International Journal of Electrochemistry
Article Type:Report
Date:Jan 1, 2014
Words:5347
Previous Article:Selection of the best process stream to remove [Ca.sup.2+] ion using electrodialysis from sugar solution.
Next Article:Electroanalytical methodology for the direct determination of 2,4-dichlorophenoxyacetic acid in soil samples using a graphite-polyurethane electrode.
Topics:

Terms of use | Privacy policy | Copyright © 2021 Farlex, Inc. | Feedback | For webmasters