Small Incision Lenticule Extraction (SMILE) for Moderate and High Myopia: Seven-Year Outcomes of Refraction, Corneal Tomography, and Wavefront Aberrations.

1. Introduction

As opposed to flap-based surgical procedures, small incision lenticule extraction (SMILE) is a minimally invasive refractive surgical technique that involves the manual removal of femtosecond laser-created intrastromal lenticule through a small side cut. Sekundo et al. [1] first introduced this new procedure in 2011. The first clinical study [2] of femtosecond lenticule extraction in China was also reported in 2011. Numerous clinical studies [3-9] suggested that SMILE is a safe and effective procedure for myopia correction, and the follow-up periods in these studies mostly spanned from 3 months to 3 years, but rarely up until 4 years [10-14]. In 2019, we [15] have previously compared the 5-year outcomes of SMILE and femtosecond laser-assisted LASIK (FS-LASIK) in patients with myopia. To date, more than 2 million SMILE procedures have been performed worldwide. Its long-term safety and efficacy have received enormous attention.

It is noted that the long-term observation of corneal stability and wavefront aberrations following SMILE is of great significance. The present study aims to evaluate the seven-year outcomes of refraction, corneal tomography, and wavefront aberrations after SMILE for moderate and high myopia.

2. Materials and Methods

2.1. Subjects. A total of 26 patients (26 eyes) who underwent SMILE between May 2010 to March 2013 at Fudan University Eye and ENT Hospital (Shanghai, China) were recruited in this prospective study, and only the right eye was included in this study. The mean follow-up period was 82.53 [+ or -] 8.5 months (range 73 to 101).

The inclusion criteria were as follows: (i) dissatisfaction of wearing glasses or contact lens; (ii) corrected distance visual acuity (CDVA) of 20/25 or greater; (iii) age 18 years or older; (iv) manifest refraction spherical equivalent (MRSE) of -1.0 to -9.0 D and manifest cylinder of 0 to -6.0 D; (v) a stable refraction state for at least two years; (vi) residual corneal stromal bed thickness of more than 280 wm; and (vii) no use of contact lenses over the last 2 weeks. Patients with suspicious keratoconus, severe dry eyes, cataract, retinal detachment, or other ocular disorders were excluded. In addition, those with systemic diseases such as diabetes and connective tissue diseases were excluded as well. The demographic and clinical characteristics of patients with moderate and high myopia are shown in Table 1.

This study adhered to the tenets of the Declaration of Helsinki and was approved by the Medical Ethics Committee of Fudan University Eye and ENT Hospital, Shanghai, China. Written informed consent was obtained from all participants before enrollment.

2.2. Surgical Procedure. The surgical technique has been detailedly described by Miao et al. [16]. VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Jena, Germany) was set to a pulse energy of 130 nJ and repetition rate of 500 kHz. Additional parameter settings were as follows: 6.5 to 6.8 mm lenticule diameter, 100 to 110 y.m cap thickness, 7.5 to 7.8 cap diameter (larger than 1 mm of lenticule), and a 4.5 mm side cut (90 degrees) at 12:00 clock. All procedures were performed by the same experienced surgeon (XZ).

Postoperative medications included levofloxacin 4 times a day for 1 week and sodium hyaluronate 4 times a day for 1 month. Meanwhile, 0.1% fluorometholone solution was tapered gradually once every three days from 8 to 1 times daily.

2.3. Main Outcome Measures. The following parameters were assessed preoperatively at 1 month, 1 year, 5 years, and 7 years postoperatively: (i) uncorrected distance visual acuity (UDVA) and CDVA; (ii) manifest and objective refraction; (iii) intraocular pressure (Tonoref II, Nidek, Japan); (iv) slit-lamp examination; and (v) central corneal thickness (CCT), mean corneal front curvature (MCFC), mean corneal back curvature (MCBC), posterior central elevation (PCE), preoperative PCE subtracted from postoperative PCE ([DELTA]PCE), and wavefront aberrations.

CCT, MCFC, MCBC, PCE, APCE, and wavefront aberrations were measured using a corneal tomography (Pentacam, Oculus GmbH, Wetzlar, Germany). MCFC, MCBC, and PCE were delineated in the central 4 mm area above the 8 mm reference best-fit sphere. [DELTA]PCE was defined as the difference between preoperative PCE and postoperative PCE at two time points.

Corneal wavefront aberrations were evaluated at a 5 mm analysis diameter. The coefficients of spherical aberration ([z.sup.0.sub.4]), the vertical coma ([z.sup.-1.sub.3]), the horizontal coma ([z.sup.1.sub.3]), the vertical trefoil ([z-.sup.3.sub.3]), horizontal trefoil ([z.sup.3.sub.3]), and the root mean square (RMS) of total higher-order aberrations (HOAs) up to fourth order were calculated using Zernike polynomials.

2.4. Statistical Analysis. All data were analyzed using SPSS version 23.0 statistical software (SPSS Inc., Chicago, IL, USA). Continuous variables were presented as mean[+ or -] standard deviation (SD), while categorical variables were shown as frequency or percentage. Pearson correlation coefficient was used to determine the correlation between the attempted and achieved spherical equivalent. Repeated measure analysis of variance was performed to assess the standardized differences of preoperative and postoperative visits at various time points. The post hoc test with Bonferroni correction was used to compare the data between two different time points. P values of less than 0.05 were considered statistically significant.

3. Results

All operations were completed smoothly without any intraoperative and postoperative complications. No case of corneal ectasia was found in the present study.

3.1. Efficacy and Safety. The efficacy index (postoperative UDVA/preoperative CDVA) was 1.14 [+ or -] 0.19 (Figure 1(a)). Among the 26 eyes, all eyes (100%) achieved an UDVA of 20/ 20 or better, 19 eyes (73%) achieved an UDVA of 20/16 or better, and 5 eyes (19%) achieved an UDVA of 20/12.5 or better.

The safety index (postoperative CDVA/preoperative CDVA) was 1.19 [+ or -] 0.20 (Figure 1(b)). Eleven out of 26 eyes (42%) demonstrated no change in CDVA. 9 eyes (35%) gained one line, 6 eyes (23%) gained two lines, and no eyes lost CDVA.

3.2. Predictability and Stability. As shown in Figure 1(d), 24 eyes (92%) and 26 eyes (100%) were within [+ or -] 0.5 D and [+ or -] 1.00D of the targeted refraction, respectively. Meanwhile, 25 eyes (96%) and 26 eyes (100%) were within [+ or -] 0.5 D and [+ or -] 1.00 D of refractive astigmatism, respectively (Figure 1(e)). A scatter plot of the attempted versus the achieved correction (spherical equivalent) is illustrated in Figure 1(c).

The mean values of MRSE went from 0.04 [+ or -] 0.15 D at 1 month postoperatively to -0.21 [+ or -] 0.23 D at 7 years postoperatively (P = 0.023). A mean refractive regression of -0.17 D was observed between 1 month and 7 years postoperatively, which corresponded to a regression rate of -0.02 D per year. In addition, the change in spherical equivalent refractive error was more than 0.5 D in 1 (4%) out of 25 eyes (Figure 1(f)).

3.3. Corneal Stability Analysis. The outcomes of corneal stability analysis are presented in Table 2. The mean values of CCT and MCFC at 7 years after SMILE were significantly decreased compared to those measured preoperatively (all P < 0.001). However, PCE and MCBC showed no significant change between before and 7 years after surgery (P = 0.180), and no significant differences were found in the values of APCE at different time points after surgery (P = 0.463). Figure 2 shows the differences between the posterior corneal surface maps obtained by corneal tomography preoperatively (a) and 1 month (b), 1 year (c), 5 years (d), and 7 years (e) after SMILE.

3.4. Corneal Wavefront Aberrations. Table 3 displays the changes in corneal wavefront aberrations following SMILE. Vertical coma and the root mean square values of HOAs were significantly increased in both corneal anterior surface and total cornea after SMILE surgery compared to those measured before the surgery (all P < 0.001). Besides, no significant differences were found in the values of spherical aberration, horizontal coma, vertical trefoil, and horizontal trefoil between pre- and post-SMILE surgery (P = 0.055 ~ 0.432 > 0.05).

4. Discussion

Our study indicated that 100% eyes reached 20/20 or better in UDVA at 7-year follow-up. The efficacy and safety indices were 1.14 [+ or -] 0.19 and 1.19 [+ or -] 0.20, respectively. SMILE showed excellent safety and efficacy for moderate-to-high myopia correction. Han et al. [11] demonstrated that the UDVA was 20/20 or better in 92% of eyes at 4 years after SMILE, and the efficacy and safety indices were 1.07 [+ or -] 0.16 and 1.16 [+ or -] 0.14. Blum et al. [10] reported the data from 56 eyes after SMILE during a 5-year follow-up period. They found the efficacy and safety indices were 0.9 and 1.2, respectively. Agca et al. [14] suggested that efficacy and safety indices were 0.98 [+ or -] 0.21 and 1.04 [+ or -] 0.15 at 5 years after SMILE for mild and moderate myopia. These results were consistent with our study. Indeed, the long-term results (7 years) confirmed the efficacy and safety of the SMILE procedure.

In this study, 92% and 100% of eyes were within [+ or -] 0.5 D and [+ or -] 1.00 D of the targeted correction, respectively. During a 4-year follow-up period, Burazovitch et al. [12] found that 87% of eyes were within [+ or -]0.50 D of the intended correction in patients with high myopia. Moreover, in the study by Han et al. [11], 89% of eyes were within [+ or -] 0.50 D of the intended correction and 100% were within [+ or -] 1.00 D. Similarly, Li et al. [15] reported that 90% and 100% of eyes were within [+ or -] 0.5 D and [+ or -] 1.00 D of the intended correction, respectively, at 5 years after SMILE. Our findings were similar with the abovementioned studies. Besides, Agca et al. [13] demonstrated 5-year results of 37 cases with high myopia, in which 59% of them are within [+ or -] 0.50 D of the intended correction, and 92% of them are within [+ or -] 1.00 D. They clarified that it was most likely attributed to a greater tendency toward undercorrection. Agca et al. [14] showed that 93% of eyes were within [+ or -] 0.50 D of the intended correction and 100% were within [+ or -] 1.00 D among patients with mild-to-moderate myopia. The predictability after 7 years of SMILE in the current study was slightly better, which may be related to surgical parameters' design and calculation. Additionally, the use of a new nomogram could help improve the accuracy of refractive correction [17].

A mean refractive regression of -0.17 D was observed between 1 month and 7 years postoperatively, which corresponded to a regression rate of -0.02 D per year. Blum et al. [18] reported the 10-year refraction after SMILE was -0.35 [+ or -] 0.66 D, corresponding to a regression of -0.30 D only. Pedersen et al. [4] found a regression of -0.08 D from 3 months to 3 years after SMILE. These studies were similar with ours. However, Agca et al. [13] reported 5-year outcomes of patients with high myopia after SMILE and found a statistically significant relationship between 1- and 5-year postoperative regression. They concluded that regression could start in the early postoperative period. In other long-term studies [19, 20] of LASIK for moderate and high myopia, a mean regression of 0.63 to 0.97 D was observed after 6 or 7 years. Li et al. [15] compared the 5-year results between SMILE and FS-LASIK, and the average regression of the SMILE group and FS-LASIK group from 6 months to 5 years postoperatively was found to be -0.02 D and -0.12 D. SMILE maintained the stability of refraction better than FS-LASIK. This maybe contributed to better preservation of corneal biomechanics [21].

We also found the changes in MCBC and PCE before and 7 years after the surgery were not statistically significant. Our previous studies [22, 23] revealed that the posterior corneal surface remained stable 1 year and 3 years after SMILE. Similar results have been reported by Gyldenkerne et al. [24], suggesting that the structure of cornea remains stable after SIMLE. Wang et al. [25] evaluated PCE change and corneal biomechanical parameters such as corneal hysteresis (CH) and the corneal resistance factor (CRF) in eyes after SMILE and the FSLASIK group and observed PCE change became greater in the FS-LASIK group than that in the SMILE group at 12 months after surgery. Meanwhile, FS-LASIK demonstrated a greater reduction of CRF after operation. However, further investigations with larger sample sizes and longer follow-up periods are needed.

In addition, the results of this study indicated that the values of vertical coma increased remarkably 7 years after SMILE, followed by HOA values. There were no significant changes in the values of spherical aberrations and trefoil. All the four wavefront aberrations remained relatively stable at the indicated postoperative time points. These results were consistent with the findings of Agca et al. [26]. Pedersen et al. [4] show the decrease in HOA and spherical aberration from 3 months to 3 years after SMILE, probably due to the long term corneal remodeling after the surgery. A recent study by Gyldenkerne et al. [27] demonstrated that the spherical aberration did not change significantly at 3 months after SMILE surgery. Besides, Lee et al. [28] compared the corneal aberrations between SMILE and transepithelial photorefractive keratectomy (PRK) after 6 months and found smaller spherical aberration and larger coma values in the SMILE group.

The present study has several limitations. First, the sample size was relatively small. Second, patients with moderate and high myopia were categorized into a single group. Finally, this study focused on corneal aberrations instead of all eye aberrations.

In conclusion, this long-term follow-up study reveals that SMILE is an effective, safe, and stable surgical approach for myopia correction, with good predictability and relatively constant corneal stability and wavefront aberrations.

https://doi.org/10.1155/2020/3825864

Data Availability

Data analyzed during the current study are available from the corresponding author upon reasonable request.

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this article.

Authors' Contributions

FX and YS contributed equally to this work.

Acknowledgments

This work was supported by the National Natural Science Foundation of China (grant no. 81770955), Project of Shanghai Science and Technology (grant no. 17411950200), and National Natural Science Foundation of China for Young Scholars (grant no. 81600762).

References

[1] W. Sekundo, K. S. Kunert, and M. Blum, "Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study," British Journal of Ophthalmology, vol. 95, no. 3, pp. 335-339, 2011.

[2] X. T. Zhou, Z. X. Dong, P. J. Yao, J. Huang, Y. Xu, and H. P. Xu, "The clinical study of femtosecond lenticule extraction for myopia," Zhonghua Yan Ke Za Zhi, vol. 47, no. 7, pp. 584-588, 2011.

[3] K. Kamiya, K. Shimizu, A. Igarashi, and H. Kobashi, "Visual and refractive outcomes of femtosecond lenticule extraction and small-incision lenticule extraction for myopia," American Journal of Ophthalmology, vol. 157, no. 1, pp. 128-134.e2, 2014.

[4] I. B. Pedersen, A. Ivarsen, and J. Hjortdal, "Three-year results of small incision lenticule extraction for high myopia: refractive outcomes and aberrations," Journal of Refractive Surgery, vol. 31, no. 11, pp. 719-724, 2015.

[5] R. S. Hansen, N. Lyhne, J. Grauslund, and A. H. Vestergaard, "Small-incision lenticule extraction (SMILE): outcomes of 722 eyes treated for myopia and myopic astigmatism," Graefe's Archive for Clinical and Experimental Ophthalmology, vol. 254, no. 2, pp. 399-405, 2016.

[6] M. A. Torky and Y. A. Alzafiri, "Visual and refractive outcomes of small-incision lenticule extraction in mild, moderate, and high myopia: six-month results," Journal of Cataract & Refractive Surgery, vol. 43, no. 4, pp. 459-465, 2017.

[7] H. Kobashi, K. Kamiya, A. Igarashi, M. Takahashi, and K. Shimizu, "Two-years results of small-incision lenticule extraction and wavefront-guided laser in situ keratomileusis for myopia," Acta Ophthalmologica, vol. 96, no. 2, pp. e119-e126, 2018.

[8] T. Han, Y. Xu, X. Han et al., "Three-year outcomes of small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for myopia and myopic astigmatism," British Journal of Ophthalmology, vol. 103, no. 4, pp. 565-568, 2019.

[9] E. El-Mayah, M. Anis, M. Salem, D. Pinero, and M. Hosny, "Comparison between Q-adjusted LASIK and small-incision lenticule extraction for correction of myopia and myopic astigmatism," Eye & Contact Lens: Science & Clinical Practice, vol. 44, no. 2, pp. S426-S432, 2018.

[10] M. Blum, K. Taubig, C. Gruhn, W. Sekundo, and K. S. Kunert, "Five-year results of small incision lenticule extraction (ReLEx SMILE)," British Journal of Ophthalmology, vol. 100, no. 9, pp. 1192-1195, 2016.

[11] T. Han, K. Zheng, Y. Chen, Y. Gao, L. He, and X. Zhou, "Four-year observation of predictability and stability of small incision lenticule extraction," BMC Ophthalmology, vol. 16, no. 1, p. 149, 2016.

[12] J. Burazovitch, D. Naguzeswski, T. Beuste, and M. Guillard, "Predictability of SMILE over four years in high myopes," Journal Francais d'Ophtalmologie, vol. 40, no. 6, pp. e201-e209, 2017.

[13] A. Agca, I. Cakir, B. T. Aygun et al., "Visual and refractive outcomes of small-incision lenticule extraction in high myopia: 5-year results," Journal of Ophthalmology, vol. 2018, Article ID 5893126, 6 pages, 2018.

[14] A. Agca, B. Tulu, D. Yasa, Y. Yildirim, B. K. Yildiz, and A. Demirok, "Long-term (5 years) follow-up of small-incision lenticule extraction in mild-to-moderate myopia," Journal of Cataract & Refractive Surgery, vol. 45, no. 4, pp. 421-426, 2019.

[15] M. Li, M. Li, Y. Chen et al., "Five-year results of small incision lenticule extraction (SMILE) and femtosecond laser LASIK (FS-LASIK) for myopia," Acta Ophthalmologica, vol. 97, no. 3, pp. e373-e380, 2019.

[16] H. Miao, L. He, Y. Shen, M. Li, Y. Yu, and X. Zhou, "Optical quality and intraocular scattering after femtosecond laser small incision lenticule extraction," Journal of Refractive Surgery, vol. 30, no. 5, pp. 296-302, 2014.

[17] J. O. Hjortdal, A. H. Vestergaard, A. Ivarsen, S. Ragunathan, and S. Asp, "Predictors for the outcome of small-incision lenticule extraction for myopia," Journal of Refractive Surgery, vol. 28, no. 12, pp. 865-871, 2012.

[18] M. Blum, A. S. Lauer, K. S. Kunert, and W. Sekundo, "10-Year results of small incision lenticule extraction," Journal of Refractive Surgery, vol. 35, no. 10, pp. 618-623, 2019.

[19] W. Sekundo, K. Bonicke, P. Mattausch, and W. Wiegand, "Six-year follow-up of laser in situ keratomileusis for moderate and extreme myopia using a first-generation excimer laser and microkeratome," Journal of Cataract & Refractive Surgery, vol. 29, no. 6, pp. 1152-1158, 2003.

[20] W. N. Zalentein, T. M. T. Tervo, and J. M. Holopainen, "Seven-year follow-up of LASIK for myopia," Journal of Refractive Surgery, vol. 25, no. 3, pp. 312-318, 2009.

[21] D. Wu, Y. Wang, L. Zhang, S. Wei, and X. Tang, "Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis," Journal of Cataract & Refractive Surgery, vol. 40, no. 6, pp. 954-962, 2014.

[22] Y. Zhao, M. Li, J. Zhao et al., "Posterior corneal elevation after small incision lenticule extraction for moderate and high myopia," PLoS One, vol. 11, no. 2, Article ID e0148370, 2016.

[23] Y. Zhao, W. Jian, Y. Chen, M. C. Knorz, and X. Zhou, "Three-year stability of posterior corneal elevation after small incision lenticule extraction (SMILE) for moderate and high myopia," Journal of Refractive Surgery, vol. 33, no. 2, pp. 84-88, 2017.

[24] A. Gyldenkerne, A. Ivarsen, and J. O. Hjortdal, "Comparison of corneal shape changes and aberrations induced by FSLASIK and SMILE for myopia," Journal of Refractive Surgery, vol. 31, no. 4, pp. 223-229, 2015.

[25] B. Wang, Z. Zhang, R. K. Naidu et al., "Comparison of the change in posterior corneal elevation and corneal biomechanical parameters after small incision lenticule extraction and femtosecond laser-assisted LASIK for high myopia correction," Contact Lens and Anterior Eye, vol. 39, no. 3, pp. 191-196, 2016.

[26] A. Agca, A. Demirok, K. I. Cankaya et al., "Comparison of visual acuity and higher-order aberrations after femtosecond lenticule extraction and small-incision lenticule extraction," Contact Lens and Anterior Eye, vol. 37, no. 4, pp. 292-296, 2014.

[27] A. Gyldenkerne, A. Ivarsen, and J. Hjortdal, "Optical and visual quality after small-incision lenticule extraction," Journal of Cataract & Refractive Surgery, vol. 45, no. 1, pp. 54-61, 2019.

[28] H. Lee, D. S. Y. Kang, D. Z. Reinstein et al., "Comparing corneal higher-order aberrations in corneal wavefront-guided transepithelial photorefractive keratectomy versus small-incision lenticule extraction," Journal of Cataract & Refractive Surgery, vol. 44, no. 6, pp. 725-733, 2018.

Fei Xia, (1,2,3) Yang Shen [ID], (1,2,3) Tian Han [ID], (1,2,3) Jing Zhao, (1,2,3) Haipeng Xu [ID], (1,2,3) and Xingtao Zhou [ID] (1,2,3)

(1) Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China

(2) NHC Key Laboratory of Myopia (Fudan University), Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China

(3) Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China

Correspondence should be addressed to Xingtao Zhou; doctzhouxingtao@163.com

Received 17 January 2020; Accepted 27 March 2020; Published 23 April 2020

Academic Editor: Alejandro Cervino

Caption: Figure 1: Refractive outcomes at 7 years postoperatively for 26 eyes for moderate and high myopia (UDVA = uncorrected distance visual acuity, CDVA = corrected distance visual acuity, D = diopters, Preop = preoperative, and Postop = postoperative). Uncorrected distance visual acuity (a); change in corrected distance visual acuity (b); spherical equivalent attempted vs achieved (c); spherical equivalent refractive accuracy (d); refractive astigmatism (e); stability of spherical equivalent refraction (f).

Caption: Figure 2: Comparison of posterior corneal surface maps obtained by corneal topography preoperatively (a), 1 month (b), 1 year (c), 5 years (d), and 7 years (e) after small incision lenticule extraction (SMILE).
Table 1: Baseline characteristics of patients.

Parameters                        Mean [+ or -] SD (range)

Gender (n/n)                         9 males/17 females
Age (years)                    28.27 [+ or -] 7.76 (18 to 43)
Average follow-up (months)     82.53 [+ or -] 8.5 (73 to 101)
IOP (mmHg)                   16.50 [+ or -] 1.69 (13.6 to 19.5)
Axial length                26.02 [+ or -] 0.80 (24.12 to 27.29)
MRSE (D)                    -6.33 [+ or -] 1.19 (-8.75 to -4.38)
Manifest sphere (D)         -5.95 [+ or -] 1.14 (-8.50 to -4.25)
Manifest cylinder (D)         -0.76 [+ or -] 0.48 (-1.50 to 0)
Lenticule thickness (wm)      125.92 [+ or -] 18.32 (95 to 164)

D = diopters; MRSE = manifest refraction spherical equivalent;
IOP = intraocular pressure.

Table 2: Corneal stability analysis of Scheimpflug imaging.

Parameters            Pre                     1 month

CCT          544.11 [+ or -] 28.19   435.06 [+ or -] 39.63 (a)
MCFC          43.53 [+ or -] 0.27     38.56 [+ or -] 0.44 (a)
MCBC          -6.37 [+ or -] 0.23       -6.38 [+ or -] 0.22
PCE           3.22 [+ or -] 2.76      1.50 [+ or -] 2.01 (a)
[DELTA]PCE            --                -0.71 [+ or -] 3.14

Parameters             1 year                       5 year

CCT          439.89 [+ or -] 38.23 (ab)   445.56 [+ or -] 36.10 (ab)
MCFC          38.87 [+ or -] 0.43 (ab)     39.00 [+ or -] 0.40 (ab)
MCBC             -6.34 [+ or -] 0.20           -6.36 [+ or -] 0.23
PCE            0.67 [+ or -] 2.22 (a)          1.94 [+ or -] 3.32
[DELTA]PCE      -1.82 [+ or -] 4.61          -0.88 [+ or -] 4.06

Parameters             7 year               P

CCT          442.06 [+ or -] 37.72 (ab)   <0.001
MCFC         39.15 [+ or -] 0.40 (abc)    <0.001
MCBC            -6.34 [+ or -] 0.21       0.089
PCE              1.72 [+ or -] 2.54       <0.001
[DELTA]PCE      -1.76 [+ or -] 4.02       0.463

CCT = central corneal thickness; MCFC = mean corneal front
curvature (from central 4 mm diameter cornea); MCBC = mean corneal
back curvature (from central 4 mm diameter cornea); PCE = posterior
central elevation; [DELTA]PCE = subtracting preoperative PCE from
postoperative PCE; (a) vs pre values of statistical significance (P
< 0.05); (b) vs 1-month values of statistical significance (P <
0.05); (c) vs 1-year values of statistical significance (P < 0.05).

Table 3: Preoperative versus postoperative corneal wavefront
aberrations for a 5 mm pupil.

Parameters                      Pre                   1 month

Corneal (front)
SA                      0.13 [+ or -] 0.05      0.16 [+ or -] 0.08
Coma (vertical)         -0.03 [+ or -] 0.13   -0.31 [+ or -] 0.26 (a)
Coma (horizontal)       -0.01 [+ or -] 0.04       0 [+ or -] 0.16
Trefoil (vertical)      0.01 [+ or -] 0.06      0.05 [+ or -] 0.06
Trefoil (horizontal)    0.01 [+ or -] 0.03      0.05 [+ or -] 0.08
RMS HOA                 0.21 [+ or -] 0.02    0.45 [+ or -] 0.06 (a)
Corneal (back)
SA                      -0.08 [+ or -] 0.02     -0.08 [+ or -] 0.02
Coma (vertical)         -0.02 [+ or -] 0.03     0 [+ or -] 0.03 (a)
Coma (horizontal)       0.01 [+ or -] 0.02      0.01 [+ or -] 0.03
Trefoil (vertical)      0.01 [+ or -] 0.02        0 [+ or -] 0.03
Trefoil (horizontal)      0 [+ or -] 0.02       0.01 [+ or -] 0.02
RMS HOA                 0.10 [+ or -] 0.02      0.11 [+ or -] 0.02
Corneal (total)
SA                      0.11 [+ or -] 0.05      0.14 [+ or -] 0.09
Coma (vertical)         -0.04 [+ or -] 0.13   -0.35 [+ or -] 0.38 (a)
Coma (horizontal)         0 [+ or -] 0.05       0.01 [+ or -] 0.17
Trefoil (vertical)      0.02 [+ or -] 0.07      0.05 [+ or -] 0.07
Trefoil (horizontal)    0.01 [+ or -] 0.04      0.07 [+ or -] 0.09
RMS HOA                 0.21 [+ or -] 0.07    0.49 [+ or -] 0.25 (a)

Parameters                      1 year

Corneal (front)
SA                        0.13 [+ or -] 0.16
Coma (vertical)         -0.35 [+ or -] 0.22 (a)
Coma (horizontal)         -0.02 [+ or -] 0.14
Trefoil (vertical)        0.04 [+ or -] 0.08
Trefoil (horizontal)      0.01 [+ or -] 0.06
RMS HOA                 0.45 [+ or -] 0.05 (a)
Corneal (back)
SA                        -0.08 [+ or -] 0.02
Coma (vertical)           0 [+ or -] 0.03 (a)
Coma (horizontal)         0.01 [+ or -] 0.03
Trefoil (vertical)          0 [+ or -] 0.02
Trefoil (horizontal)      0.02 [+ or -] 0.04
RMS HOA                   0.11 [+ or -] 0.02
Corneal (total)
SA                        0.11 [+ or -] 0.07
Coma (vertical)         -0.38 [+ or -] 0.23 (a)
Coma (horizontal)         -0.01 [+ or -] 0.14
Trefoil (vertical)        0.05 [+ or -] 0.10
Trefoil (horizontal)      0.03 [+ or -] 0.07
RMS HOA                 0.48 [+ or -] 0.21(a)

Parameters                      5 years

Corneal (front)
SA                        0.15 [+ or -] 0.07
Coma (vertical)         -0.31 [+ or -] 0.22 (a)
Coma (horizontal)         -0.03 [+ or -] 0.15
Trefoil (vertical)        -0.01 [+ or -] 0.05
Trefoil (horizontal)      0.01 [+ or -] 0.06
RMS HOA                 0.43 [+ or -] 0.04 (a)
Corneal (back)
SA                        -0.08 [+ or -] 0.02
Coma (vertical)           0 [+ or -] 0.03 (a)
Coma (horizontal)         0.01 [+ or -] 0.03
Trefoil (vertical)        -0.02 [+ or -] 0.03
Trefoil (horizontal)      0.02 [+ or -] 0.03
RMS HOA                   0.11 [+ or -] 0.02
Corneal (total)
SA                        0.13 [+ or -] 0.08
Coma (vertical)         -0.34 [+ or -] 0.23 (a)
Coma (horizontal)         -0.03 [+ or -] 0.14
Trefoil (vertical)      -0.03 [+ or -] 0.07 (b)
Trefoil (horizontal)      0.04 [+ or -] 0.07
RMS HOA                 0.46 [+ or -] 0.18 (a)

Parameters                      7 years             P

Corneal (front)
SA                        0.14 [+ or -] 0.05      0.414
Coma (vertical)         -0.34 [+ or -] 0.21 (a)   <0.001
Coma (horizontal)         -0.08 [+ or -] 0.14     0.102
Trefoil (vertical)        -0.01 [+ or -] 0.04     0.135
Trefoil (horizontal)      0.02 [+ or -] 0.07      0.282
RMS HOA                 0.43 [+ or -] 0.05 (a)    <0.001
Corneal (back)
SA                      -0.09 [+ or -] 0.01 (b)   0.001
Coma (vertical)             0 [+ or -] 0.03       <0.001
Coma (horizontal)         0.01 [+ or -] 0.03      0.244
Trefoil (vertical)        -0.01 [+ or -] 0.04     0.066
Trefoil (horizontal)      0.01 [+ or -] 0.04      0.432
RMS HOA                   0.12 [+ or -] 0.03      0.033
Corneal (total)
SA                        0.11 [+ or -] 0.05      0.359
Coma (vertical)         -0.38 [+ or -] 0.22 (a)   <0.001
Coma (horizontal)         -0.09 [+ or -] 0.14     0.055
Trefoil (vertical)      -0.02 [+ or -] 0.05 (b)   <0.001
Trefoil (horizontal)      0.03 [+ or -] 0.07      0.247
RMS HOA                 0.46 [+ or -] 0.21 (a)    <0.001

HOAs = higher-order aberrations; SA = spherical aberration; (a) vs.
pre values of statistical significance (P < 0.05); (b) vs. 1-month
values of statistical significance (P < 0.05); (c) vs. 1-year
values of statistical significance (P < 0.05). Data are presented
as mean [+ or -] SD.
COPYRIGHT 2020 Hindawi Limited
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2020 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Clinical Study
Author:Xia, Fei; Shen, Yang; Han, Tian; Zhao, Jing; Xu, Haipeng; Zhou, Xingtao
Publication:Journal of Ophthalmology
Geographic Code:9CHIN
Date:May 31, 2020
Words:4733
Previous Article:Knowledge towards Strabismus and Associated Factors among Adults in Gondar Town, Northwest Ethiopia.
Next Article:Evaluation of Functional Outcomes and OCT-Biomarkers after Intravitreal Dexamethasone Implant for Postoperative Cystoid Macular Edema in...
Topics:

Terms of use | Privacy policy | Copyright © 2022 Farlex, Inc. | Feedback | For webmasters |