Rapid and Simultaneous Prediction of Eight Diesel Quality Parameters through ATR-FTIR Analysis.

1. Introduction

Diesel fuel is a petroleum-derived product of great importance for a country's economy since most of the transportation of industrial and agricultural products depends on diesel vehicles [1, 2]. This fuel is a complex mixture composed mainly of paraffinic, olefinic, and aromatic hydrocarbons ranging from 8 to 28 carbon atoms and, in a lower concentration, substances containing oxygen, nitrogen, sulfur, and metals [3-5]. The diesel composition is influenced by several factors, such as the origin of crude oil, operating variables of the refinery, the addition of fractions from cracking process, and the insertion of additives to increase engine performance [3]. Therefore, the fuel quality is susceptible to many variables until the fuel reaches the consumer. In this perspective, the monitoring of diesel quality parameters is extremely important for commercialization, engine performance, consumer rights, business competition, and environmental risks [5, 6].

The assays performed to ensure the diesel quality are based on standardized procedures that require specific equipment to determine each physicochemical parameter. According to the standard methods, the quality assessment requires considerable sample volume and analysis time, besides the great expense of equipment maintenance and several specialized analysts [7-12]. Therefore, the development of methods to monitor diesel quality accurately, quickly, and environmentally friendly is highly necessary [13]. This becomes possible by attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy associated with multivariate regression methods such as partial least square (PLS). Studies demonstrated the possibility to predict some diesel properties using midinfrared spectroscopy combined with chemometric tools [14-18], some aimed at the prediction of biodiesel content [16], and others were devoted to the identification of diesel adulteration with waste vegetable oils [17, 18].

In USA, European Community, and Japan, the regulations of diesel properties for consumption are established, respectively, by ASTM D975, EN 590, and JIS K2204 [19-21]. In Brazil, the regulation and supervision of fuels are performed according to ANP (National Agency of Petroleum, Natural Gas, and Biofuels) Resolution no. 30/2016, which requires that assays must be conducted according to ASTM, EN, or NBR standards [22]. According to this resolution, at least eight quality parameters of diesel are analyzed in official monitoring laboratories: aspect; color; density; flash point; total sulfur; volatility (distillation temperatures at 10% (T10), 50% (T50), and 85% (T85) recovery); cetane index; and biodiesel content [23].

The development of an alternative method for determining the physicochemical parameters of diesel through ATR-FTIR has several advantages for routine quality monitoring. The use of ATR-FTIR can reduce costs, increase analytical frequency, use smaller sample volume, and provide the determination of all required parameters using only one equipment. Moreover, infrared spectrometers are already purchased by monitoring laboratories for determination of biodiesel content in diesel according to EN 14078.

In view of the high costs and long time required to assess diesel quality by standard methods, this work aimed at the development of a simple and fast analytical method based on ATR-FTIR analysis and PLS regression method to determinate eight diesel quality parameters simultaneously. In this study, multivariate filters and variable selection techniques, such as genetic algorithm (GA), forward interval PLS (FiPLS), and backward interval PLS (BiPLS), were evaluated for the best model predictive ability.

2. Materials and Methods

2.1. Samples. For eight months, the quality parameters of 3549 samples of diesel fuel were analyzed by Cempeqc (Center for Monitoring and Research of the Quality of Fuels, Biofuels, Crude Oil and Derivatives) according to ASTM and EN standards. The samples were stored at 10[degrees]C for further spectroscopic analysis. The standards and equipment used in the determination of quality parameters are presented in Table 1.

Although an extensive sample set can provide greater robustness to a prediction model, this work aimed at the development of a simple method that can be easily reproduced by other laboratories. Therefore, we selected about 10% of the diesel samples for spectroscopic and chemometric analysis. The 3549 diesel samples were divided into groups using hierarchical cluster analysis (HCA) to select the most representative samples. An HCA was executed for each month, and the physicochemical parameters were used as variables. The clusters were performed using 60% of similarity, complete linkage method, and autoscale preprocessing to give the same influence for all variables. The software used for HCA was Pirouette (Infometrix), version 3.11. At the end of the eight months, 409 diesel samples were selected.

2.2. Spectroscopic Analysis. The infrared spectra of the 409 samples were obtained by a Nicolet 6700 FTIR spectrometer (Thermo Scientific, Waltham, USA) using 32 scans and 4 cm-1 resolution. A Smart ARK ATR sampling accessory of ZnSe crystal and angle of incidence 45[degrees] were used to acquire the infrared spectra. The ATR accessory required one milliliter for each sample, and a new background spectrum was acquired every hour to reduce the baseline shifting and ambient variations. The conditions of temperature and relative humidity during the analysis were 20.7 [+ or -] 2.0[degrees]C and 40 [+ or -] 9%, respectively.

2.3. Chemometric Analysis

2.3.1. Model Development. The chemometric analysis was executed using Matlab 2013a (MathWorks) with PLS toolbox 7.3.1 (Eigenvector Research Inc.). The FTIR spectra were converted into vectors of 1738 variables and the combination of the vectors resulted in the matrix X of dimension 409 by 1738. Prior to the development of PLS models, the sample set was separated into two-thirds for calibration (273 samples) and one-third for validation (136 samples). The Onion algorithm was used to select the samples with less covariance (based on distance from the mean) for each set and, consequently, to obtain greater sample representativeness in both sets [24, 25]. The algorithm was performed for each parameter to ensure that the calibration set had the largest range of reference values.

Initially, the PLS models were developed using the full spectra (full X-block) preprocessed by the mean center or autoscale, depending on the best fit. The number of latent variables (LV) was chosen based on the root mean square errors of calibration (RMSEC), cross-validation (RMSECV), and prediction (RMSEP) in order to minimize the prediction errors and avoid model overfitting [26, 27]. The cross-validation was performed using venetian blinds mode with 10 splits.

Then, statistical tests were applied according to ASTM E1655 [28] to detect the presence of outliers in the calibration and validation sets. Outliers include high leverage samples and samples whose reference values are inconsistent with the model. Therefore, samples with high leverage and studentized residuals were excluded from the sample sets.

2.3.2. Preprocessing Evaluation. Spectral data usually present baseline shifting due to instrumental variations and reflectance deviations [29]. The baseline shifting is typically corrected by applying the first or second derivative, or by polynomials that correct the displacement based on a standard spectrum, for example, multiplicative scatter correction (MSC) and standard normal variate (SNV). In addition, digital filters such as smoothing are also used to improve the signal-to-noise ratio of spectral data [28]. Multivariate filters, such as generalized least squares weighting (GLSW) and orthogonal signal correction (OSC), are less usual preprocesses, but these filters are very useful to eliminate baseline shifting and increase signal-to-noise ratio [30-33]. Therefore, the following preprocessing was evaluated in modeling: mean center, autoscale, Savitzky-Golay smoothing and derivatives, SNV, MSC, GLSW, and OSC.

2.3.3. Variable Selection Methods. Many studies have shown that variable selection is an efficient way to increase the signal-to-noise ratio and, as a consequence, improve the predictive ability of the model [34, 35]. When the noise dominates over the information related to the property of interest, the removal of variables often leads to better accuracy and performance of the analytical method [35, 36]. The selection of variables can be performed based on the spectral knowledge (manual approach) or through algorithms that search for variables that provide the minimum prediction error to the model. Some of the most popular methods for selecting variables are the interval selection method, such as the forward interval PLS (FiPLS), the backward interval PLS (BiPLS), and the genetic algorithm (GA), a technique that employs a probabilistic and nonlocal search process which manipulates binary strings with the coded experimental variables. Details on these variable selection methods can be found in [35].

In this study, four different approaches were evaluated to select variables: manual exclusion, FiPLS, BiPLS, and GA. The manual exclusion was carried out evaluating the spectral residues and loadings plots. Spectral regions with no absorbance or high relative standard deviation (RSD) were excluded from the data and compared with results obtained using the full spectra. Both iPLS methods were executed using interval size of 25 variables, and the number of intervals was determined by the algorithm to obtain the lowest value of RMSECV. The GA was performed with a population size of 128 models, one variable by window, initial terms of 30%, the mutation rate of 0.5%, double crossover, 200 generations, and PLS regression method. All approaches were performed using only the calibration set to avoid overestimated results.

2.3.4. Model Validation. The PLS models were statistically evaluated by figures of merit (FOM) according to ASTM E1655 and Valderrama et al. [28, 37]. The accuracy of the models, defined as the degree of agreement between a measured value and reference value, was assessed by the values of RMSECV, RMSEP, correlation coefficients (r), average relative errors (ARE), and relative percent difference (RPD). The RMSECV was obtained by cross-validation using the venetian blinds mode with 10 splits, and the RMSEP was obtained by the validation samples that were measured independently from the calibration samples. Then, the RMSECV and RMSEP were compared with the reproducibility of the reference method. The ARE was used as a parameter to evaluate the magnitude of the prediction errors in relation to the reference values [38]. The ARE value was calculated by

[mathematical expression not reproducible], (1)

where [y.sub.i], and [[??].sub.i] correspond, respectively, to the reference value and predicted value by the model and [n.sub.v] is the number of validation samples. The relative percent difference (RPD) was obtained by the ratio of the standard deviation of the validation set reference values to the RMSEP value. RPD values above 2.5 indicate that the model has acceptable accuracy over the measurement range, while values above 10 are considered excellent for alternative methods [39].

Linearity is an important parameter to evaluate the performance of the model since the PLS regression method is not suitable for nonlinear relationships between the variables x and the property of interest [40]. The linearity corresponds to the ability of the model to provide results directly proportional to the property of interest. One way to evaluate this parameter in multivariate models is through the residues of calibration and validation samples plots. If the distribution of residues is random, it can be said that the model shows a linear behavior. In addition to the residue plots, the linearity was also evaluated by the values of determination coefficients ([R.sup.2]) and bias. This last FOM indicates the presence of systematic errors in the model. Bias can be assessed by a t-test for the validation samples at a confidence interval of 95%. The average bias was calculated by summing the differences between the reference value and the predicted value divided by the number of validation samples [28]:

[mathematical expression not reproducible]. (2)

Then, the standard deviation of validation errors (SDV) was calculated as

SDV = [square root of ([summation][[([y.sub.i] - [[??].sub.i]) - bias].sup.2] / [n.sub.v] - 1)] (3)

and finally, the value of [t.sub.bias] was given by

[t.sub.bias] = [absolute value of bias] [square root of ([n.sub.v])] / SDV (4)

If the value obtained for [t.sub.bias] was greater than the critical value for [n.sub.v] - 1 degrees of freedom, then the multivariate model presented significant systematic errors.

The precision of the models was evaluated by the analysis of 14 replicates of 30 diesel samples performed on different days. The average of relative standard deviations (RSD) and the intermediate precision--calculated through (5), where n is the number of samples and m the number of replicates--were used as parameters [37]. Then, the intermediate precision was compared to the repeatability value of the reference method:

intermediate precision = [square root of ([[summation].sup.n.sub.i=1] [[summation].sup.m.sub.j=1] [([y.sub.i] - [[??].sub.i]).sup.2] / n (m-1))]. (5)

3. Results and Discussion

3.1. Physicochemical Assays. The values of reproducibility and repeatability of the reference methods, the range of measured values of each quality parameter, and the number of samples in nonconformity with ANP Resolution no. 65 [41] are shown in Table 2. The quality parameter that presented the highest number of nonconforming samples was T10, followed by T85 and biodiesel content. As ANP Resolution no. 65 allows only a variation of 0.5% (v/v) of biodiesel content, most of the samples were in a narrow range of concentration. The same occurred with the total sulfur but in two different ranges of concentration due to the availability of two types of commercial diesel with distinct sulfur content.

3.2. Spectroscopic Analysis. The FTIR spectra of all diesel samples are represented in Figure 1. Functional groups of the constituents of samples could be observed by characteristic absorption bands of each group of atoms through the infrared spectra.

The most intense bands were caused by C-H groups stretch (3000-2800 [cm.sup.-1]) and angular deformations (1464 [cm.sup.-1] and 1379 [cm.sup.-1]) [42]. The bands at 2350 [cm.sup.-1] and 667 [cm.sup.-1] were, respectively, results of asymmetrical stretch and angular deformation of C[O.sub.2] molecules present in the atmosphere [43]. The presence of biodiesel in the samples was observed by carbonyl absorption band (1750-1735 [cm.sup.-1]) and aliphatic ester absorption band (1300-1000 [cm.sup.-1]). Aromatic compounds had characteristic bands of low intensity in 900-675 [cm.sup.-1] from the C-H out-of-plane angular deformation. The sulfur is present in diesel as mercaptans and sulfides, and it was observed by S-H axial stretch at 2600-2550 [cm.sup.-1] and C-S axial stretch at 700-650 [cm.sup.-1] [43, 44]. The S-H stretch was very weak; however, few groups have absorption in this region, so it was useful for the total sulfur parameter. The vibrational group attribution to each band is present in Table 3.

3.3. Chemometric Analysis

3.3.1. Outlier Detection. During calibration, outlier statistics were applied to identify samples that had unusual leverage and studentized residuals. The outlier detection was performed prior to the variable selection because the exclusion of variables may reduce outlier detection capabilities of the model [28]. The number of outliers from each sample set is shown in Table 4. Considering the calibration and validation sample set with, respectively, 273 and 136 samples, the number of outliers (3% maximum) was not significant for the prediction models.

High studentized residual values may be the result of errors in the reference measurement, spectral acquisition error, reference value transcription, or even a failure of the model. Error in the spectral acquisition would lead to the presence of the same outlier in all models of prediction; however, different outliers were detected for each model. The absence of new outliers in the model after removal of the anomalous samples indicated that there was no failure in the model. Therefore, errors in the reference values were most likely responsible for the presence of outliers.

3.3.2. Preprocessing Evaluation. The baseline shifting in the raw spectra was observed in Figure 1. The shifting may be the result of variations in the position of the ZnSe crystal since it was removed from the spectrometer for cleaning before each analysis. All the evaluated preprocessing--derivatives, MSC, SNV, GLSW, and OSC--provided baseline correction and higher correlation coefficients than mean center or autoscale preprocessing. Moreover, multivariate filters (GLSW and OSC) provided models with greater explained variance using fewer latent variables (Table 5). Therefore, all models were preprocessed using OSC, except the model for T85, which presented better fit with GLSW preprocessing.

3.3.3. Variable Selection. The exclusion of regions without information of sample constituents or low signal-to-noise ratio may improve the performance of the models [35]. In Figure 2, the noisy spectral regions can be observed through the relative standard deviation (RSD), represented by the blue line, and calculated from the mean of 14 replicates, represented by the red line. In addition, there was no absorption by the components of diesel in the ranges 4000-3100 [cm.sup.-1] and 2450-1950 [cm.sup.-1]; thus, these spectral regions were excluded, and new models were developed.

The RMSEP and correlation coefficient of validation ([r.sub.val]) obtained by the different variable selection approaches are presented in Table 6. The manual exclusion of variables provided better results only for the prediction models of flash point, T10, cetane index, and biodiesel content. The manual selection of variables had the risk of inadvertent exclusion of important variables for the modeling, impairing the performance of the model.

The selection of variables by interval selection methods reduces the values of RMSEC and RMSECV but might decrease the predictive ability of the model. The FiPLS method usually uses few intervals to correlate the spectral variables with the property of interest and, as consequence, the calibration model is more susceptible to overfitting and the prediction of unknown samples is impaired, especially properties that are correlated to several spectral variables. As the sulfur content is correlated only to the S-H and C-H bond variables, the FiPLS method provided the best fit to the model.

The distillation temperatures and the cetane index depend on the size and structure of the hydrocarbon chains of the diesel components; therefore, these are properties related to several functional groups with response in the midinfrared region. Thus, the selection methods such as BiPLS, which seek to exclude noisy variables rather than including variables more correlated to the property of interest, tend to be more suitable for optimization of these diesel parameters.

The analytical signals in the midinfrared region result in many correlated variables; that is, FTIR data present many collinearities. Normally, the problem of collinearity can be attenuated by the application of the genetic algorithm, since the spectral variables are manipulated in binary strings and the search for variables that provide a minor error of prediction is performed by a probabilistic and nonlocal process [35]. GA was the best variable selection approach for prediction models of density, flash point, T50, and biodiesel content.

In general, the selection of variables by iPLS and GA provided improvements in the predictive ability of the calibration models, except for T85, and the difference between the results obtained by both algorithms was not significant. The selected variables used in the best-fitted models are presented in the supplementary material (available here) attached to the article.

3.3.4. Model Performance. After defining the most appropriate variable selection method for each parameter, the figures of merit were determined for the prediction models (Table 7). The complexity of the diesel composition, consisting of hundreds of compounds, generates a large amount of information in the FTIR spectra and, therefore, the correlation between the matrix X and the property of interest requires a considerable number of LVs. Although the use of OSC reduces the collinearity problem and increases the captured variance of the X and y blocks, several analytical signals were correlated to the properties of diesel, so several LVs were required.

The accuracy of the models was evaluated by comparing the RMSEP values (Table 7) with the reproducibility values of the reference methods (Table 2). Since all models presented RMSEP values below or equivalent to the reproducibility value, the FTIR/PLS method could be considered accurate for predicting diesel parameters. In addition, the correlation coefficients were above 0.89, except for T85; thus, the predicted values were well correlated with the reference values (Figure 3).

Although the prediction model for sulfur content presented [r.sub.val] equal to 0.987, the obtained ARE value was high when compared to the others. The high relative errors that resulted in ARE equal to 14.10% were caused by the low sensitivity of the model for prediction of S500 diesel samples. However, the RPD value indicated that the model was accurate when the RMSEP value is compared to the sulfur content range of the validation sample set.

The determination coefficients ([R.sup.2]) indicated that the prediction models of flash point and T85 presented lower linearity than the other parameters. Figure 3 shows that, for these parameters, the residues tend to be negative values with the increase of the reference value. Although the models have low bias values, the t-test revealed that there were systematic errors in the prediction models for sulfur content, T85, and biodiesel content. Since the models for sulfur and biodiesel content presented good linearity ([R.sup.2.sub.val] > 0.88), the presence of systematic errors can be reduced by the addition of more samples to the model.

The precision of the models was evaluated by the analysis of 30 diesel samples on 14 consecutive days. Although the samples were stored at 10[degrees]C between the analyses, the diesel fuel consists of semivolatile compounds and, therefore, changes in sample composition during the replicates acquisition imply an increase in measurement uncertainty. The intermediate precision values of the models were above the repeatability values of the reference methods, except for the biodiesel content prediction. However, the RSD values showed that almost all models had good precision (RSD below 1%) and only the models for prediction of flash point and sulfur content presented low precision.

Although the prediction models for flash point, sulfur content, and T85 have the limitations mentioned above, the conformity ranges of these parameters (Table 2) can be met by FTIR/PLS models with reliability since the accuracy and precision of the method are known. If an unknown sample is analyzed by FTIR and the result obtained is in the nonconformity range, it is recommended that the result is confirmed by the standard method. Since only about 2% of the diesel samples in Brazil presented nonconformities in 2017 [45], the FTIR/PLS method can be applied in routine monitoring of diesel quality to reduce the costs and time of analysis.

4. Conclusions

This study showed the possibility of applying ATR-FTIR spectroscopy with PLS regression method to predict the quality parameters (density; flash point; total sulfur content; distillation temperatures at 10% (Tl0), 50% (T50), and 85% (T85) recovery; cetane index; and biodiesel content) in commercial diesel samples.

All the evaluated preprocessing (derivatives, MSC, SNV, GLSW, and OSC) provided baseline correction and higher correlation coefficients. In addition, the GLSW and OSC preprocessing provided greater explained variance to the model using fewer latent variables. The selection of variables by iPLS or GA provided better predictive ability to the calibration models, except for T85. However, the difference between the results obtained by both algorithms was not significant.

According to the model validation, all PLS models presented acceptable accuracy when compared to the values of reproducibility and had good precision, except for sulfur content prediction of S500 diesel samples. Since the application of the ATR-FTIR/PLS method is able to reduce costs and increase considerably the analytical frequency, the diesel quality monitoring programs, as well as the final consumer, can benefit greatly from the application of the proposed method.

https://doi.org/10.1155/2018/1795624

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Acknowledgments

The authors would like to thank Capes, CNPq, and Fundunesp for providing academic scholarships and Cempeqc for providing financial support and the samples.

Supplementary Materials

In the supplementary material can be visualized the variables used in the PLS models that presented better predictive abilities. The variable selection method used for each diesel property is also presented in the supplementary material. Supplementary Figure 1: spectra variables of GAPLS model for density prediction. Supplementary Figure 2: spectra variables of GA-PLS model for flash point prediction. Supplementary Figure 3: spectra variables of FiPLS model for sulfur content prediction. Supplementary Figure 4: spectra variables of BiPLS model for T10 prediction. Supplementary Figure 5: spectra variables of GA-PLS model for T50 prediction. Supplementary Figure 6: spectra variables of PLS model for T85 prediction. Supplementary Figure 7: spectra variables of BiPLS model for cetane index prediction. Supplementary Figure 8: spectra variables of GA-PLS model for biodiesel content prediction. (Supplementary Materials)

References

[1] BP, BP Statistical Review of World Energy, British Petroleum Company, London, UK, 2016.

[2] M. Colman, P. A. Sorichetti, and S. D. Romano, "Refractive index of biodiesel-diesel blends from effective polarizability and density," Fuel, vol. 211, pp. 130-139, 2018.

[3] J. G. Speight, The Chemistry and Technology of Petroleum, CRC Press, Boca Raton, FL, USA, 4th edition, 2006.

[4] G. D. Todd, R. L. Chessin, and J. Colman, Toxicological Profile for Total Petroleum Hydrocarbons (TPH), Agency for Toxic Substances and Disease Registry, Atlanta, GA, USA, 1999.

[5] B. P. Vempatapu and P. K. Kanaujia, "Monitoring petroleum fuel adulteration: a review of analytical methods," TrAC Trends in Analytical Chemistry, vol. 92, pp. 1-11, 2017.

[6] D. A. Cunha, L. F. Montes, E. V. R. Castro, and L. L. Barbosa, "NMR in the time domain: a new methodology to detect adulteration of diesel oil with kerosene," Fuel, vol. 166, pp. 79-85, 2016.

[7] ASTM, ASTM D4052: Standard Test Method for Density, Relative Density, and API Gravity of Liquids by Digital Density Meter, ASTM International, West Conshohocken, PA, USA, 2013.

[8] ASTM, ASTM D93: Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester, ASTM International, West Conshohocken, PA, USA, 2004.

[9] ASTM, ASTM D4294: Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy Dispersive X-ray Fluorescence Spectrometry, ASTM International, West Conshohocken, PA, USA, 2010.

[10] ASTM, ASTM D86: Standard Test Method for Distillation of Petroleum Products and Liquid Fuels at Atmospheric Pressure, 2008.

[11] D4737 A, Standard Test Method for Calculated Cetane Index by Four Variable Equation, ASTM International, vol. 5West Conshohocken, PA, USA, 2010.

[12] EN, EN 14078: Determination of fatty acid methyl ester (FAME) content in middle distillates, Infrared spectrometry method, European Committee for Standardization, Brussels, Belgium, 2009.

[13] P. M. Santos, R. S. Amais, L. A. Colnago, A. Rinnan, and M. R. Monteiro, "Time domain-NMR combined with chemometrics analysis: an alternative tool for monitoring diesel fuel quality," Energy and Fuels, vol. 29, pp. 2299-2303, 2015.

[14] L. A. Pinto, R. K. H. Galvao, and M. C. U. Araujo, "Influence of wavelet transform settings on NIR and MIR spectrometric analyses of diesel, gasoline, corn and wheat," Journal of the Brazilian Chemical Society, vol. 22, pp. 179-186, 2011.

[15] V. O. Santos, F. C. C. Oliveira, D. G. Lima et al., "A comparative study of diesel analysis by FTIR, FTNIR and FTRaman spectroscopy using PLS and artificial neural network analysis," Analytica Chimica Acta, vol. 547, no. 2, pp. 188-196, 2005.

[16] M. Fernanda Pimentel, G. M. G. S. Ribeiro, R. S. Da Cruz, L. Stragevitch, J. G. A. Pacheco Filho, and L. S. G. Teixeira, "Determination of biodiesel content when blended with mineral diesel fuel using infrared spectroscopy and multivariate calibration," Microchemical Journal, vol. 82, no. 2, pp. 201-206, 2006.

[17] N. N. Mahamuni and Y. G. Adewuyi, "Fourier transform infrared spectroscopy (FTIR) method to monitor soy biodiesel and soybean oil in transesterification reactions, petrodiesel-biodiesel blends, and blend adulteration with soy oil," Energy and Fuels, vol. 23, no. 7, pp. 3773-3782, 2009.

[18] I. P. Soares, T. F. Rezende, and I. C. P. Fortes, "Study of the behavior changes in physical-chemistry properties of diesel/biodiesel (B2) mixtures with residual oil and its quantification by partial least-squares attenuated total reflection-Fourier transformed infrared spectroscopy (PLS/ATR-FTIR)," Energy and Fuels, vol. 23, no. 8, pp. 4143-4148, 2009.

[19] ASTM, ASTM D975-Standard Specification for Diesel Fuel Oils, ASTM International, West Conshohocken, PA, USA, 2015.

[20] EN, EN 590: Automotive fuels-Diesel-Requirements and test methods, European Committee for Standardization, Brussels, Belgium, 2009.

[21] PAJ-Petroleum Association of Japan, JIS K2204-Petroleum Industry in Japan, Petroleum Association of Japan, Tokyo, Japan, 2014.

[22] ANP, Resolugao ANP No. 30: Automotive fuels-Diesel-Specification of BX to B30 Diesel Fuel, Brasilia, DF, Brazil, 2016.

[23] ANP, Panorama da Qualidade dos Combusttiveis, Brasilia, DF, Brazil, 2011.

[24] A. G. Sousa, L. I. Ahl, H. L. Pedersen, J. U. Fangel, S. O. Sorensen, and W. G. T. Willats, "A multivariate approach for high throughput pectin profiling by combining glycan microarrays with monoclonal antibodies," Carbohydrate Research, vol. 409, pp. 41-47, 2015.

[25] S. Shrestha, L. Deleuran, and R. Gislum, "Classification of different tomato seed cultivars by multispectral visible-near infrared spectroscopy and chemometrics," Journal of Spectral Imaging, vol. 1, p. a1, 2016.

[26] D. M. Hawkins, "The problem of overfitting," Journal of Chemical Information and Computer Sciences, vol. 44, no. 1, pp. 1-12, 2004.

[27] C. V. Di Anibal, M. P. Callao, and I. Ruisanchez, "1H NMR variable selection approaches for classification. A case study: the determination of adulterated foodstuffs," Talanta, vol. 86, pp. 316-323, 2011.

[28] American Society for Testing and Materials, "ASTM E1655-standard practices for infrared multivariate quantitative analysis," ASTM International, vol. 5, p. 29, 2012.

[29] P. Gemperline, Practical Guide to Chemometrics, Koros Press Limited, London, UK, 2nd edition, 2006.

[30] Eigenvector Research, "Advanced preprocessing: multivariate filtering," 2013. http://wiki.eigenvector.com/index.php?title= Advanced_Preprocessing:_Multivariate_Filtering.

[31] M. L. Zhang, G. P. Sheng, Y. Mu et al., "Rapid and accurate determination of VFAs and ethanol in the effluent of an anaerobic H2-producing bioreactor using near-infrared spectroscopy," Water Research, vol. 43, no. 7, pp. 1823-1830, 2009.

[32] L. Laghi, A. Versari, G. P. Parpinello, D. Y. Nakaji, and R. B. Boulton, "FTIR spectroscopy and direct orthogonal signal correction preprocessing applied to selected phenolic compounds in red wines," Food Analytical Methods, vol. 4, no. 4, pp. 619-625, 2011.

[33] P. Roudier, C. B. Hedley, C. R. Lobsey, R. A. Viscarra Rossel, and C. Leroux, "Evaluation of two methods to eliminate the effect of water from soil vis-NIR spectra for predictions of organic carbon," Geoderma, vol. 296, pp. 98-107, 2017.

[34] M. Vohland, M. Ludwig, S. Thiele-Bruhn, and B. Ludwig, "Determination of soil properties with visible to near- and mid-infrared spectroscopy: effects of spectral variable selection," Geoderma, vol. 223-225, pp. 88-96, 2014.

[35] Z. Xiaobo, Z. Jiewen, M. J. W. Povey, M. Holmes, and M. Hanpin, "Variables selection methods in near-infrared spectroscopy," Analytica Chimica Acta, vol. 667, no. 1-2, pp. 14-32, 2010.

[36] T. Mehmood, K. H. Liland, L. Snipen, and S. Saebo, "A review of variable selection methods in partial least squares regression," Chemometrics and Intelligent Laboratory Systems, vol. 118, pp. 62-69, 2012.

[37] P. Valderrama and J. W. B. Braga, "Estado da arte de figuras de merito de calibracao multivariada," Qutimica Nova, vol. 32, no. 5, pp. 1278-1287, 2009.

[38] D. L. Flumignan, F. de Oliveira Ferreira, A. G. Tininis, and J. E. de Oliveira, "Multivariate calibrations in gas chromatographic profiles for prediction of several physicochemical parameters of Brazilian commercial gasoline," Chemometrics and Intelligent Laboratory Systems, vol. 92, no. 1, pp. 53-60, 2008.

[39] C. J. Lomborg, J. B. Holm-Nielsen, P. Oleskowicz-Popiel, and K. H. Esbensen, "Near infrared and acoustic chemometrics monitoring of volatile fatty acids and dry matter during codigestion of manure and maize silage," Bioresource Technology, vol. 100, no. 5, pp. 1711-1719, 2009.

[40] B. K. Lavine and J. Workman, "Chemometrics," Analytical Chemistry, vol. 80, no. 12, pp. 4519-4531, 2012.

[41] ANP, Resolugao ANP No. 65: Automotive fuels-Diesel-Specification of Diesel Fuel, Brasilia, DF, Brazil, 2011.

[42] R. M. Silverstein, F. X. Webster, and D. J. Kiemle, "Spectrometric identification of organic compounds," Microchemical Journal, vol. 21, no. 4, p. 496, 2005.

[43] N. B. Colthup, L. H. Daly, and S. E. Wiberley, Introduction to Infrared and Raman Spectroscopy, Academic Press, Cambridge, MA, USA, 1990.

[44] M. C. Breitkreitz, I. M. Raimundo, J. J. R. Rohwedder et al., "Determination of total sulfur in diesel fuel employing NIR spectroscopy and multivariate calibration," Analyst, vol. 128, no. 9, pp. 1204-1207, 2003.

[45] ANP, "Boletim de monitoramento da qualidade dos combustiveis," 2017, http://www.anp.gov.br/wwwanp/publicacoes/ boletins-anp/2388-pmqc-edicoes-anteriores.

Maurilio Gustavo Nespeca (iD), (1) Rafael Rodrigues Hatanaka, (1) Danilo Luiz Flumignan, (2) and Jose Eduardo de Oliveira (1)

(1) Centro de Monitoramento e Pesquisa da Qualidade de Combustiveis, Biocombustiveis, Petrtileo e Derivados (Cempeqc), Sao Paulo State University (UNESP), R. Prof. Francisco Degni 55 Quitandinha, 14800-900 Araraquara, SP, Brazil

(2) Instituto Federal de Educacao, Ciencia e Tecnologia de Sao Paulo (IFSP), Campus Matao, Rua Estefano D'avassi, 625 Nova Cidade, 15991-502 Matao, SP, Brazil

Correspondence should be addressed to Maurilio Gustavo Nespeca; mauriliogn@gmail.com

Received 25 August 2017; Revised 13 November 2017; Accepted 28 November 2017; Published 5 February 2018

Academic Editor: Karoly Heberger

Caption: FIGURE 1: Infrared spectra of all diesel samples.

Caption: FIGURE 2: The mean spectrum (red line) and relative standard deviation (blue line) of 14 replicates of a diesel sample.

Caption: FIGURE 3: Predicted versus measured value plots of the PLS models.
TABLE 1: Standard methods and equipment used to determine the quality
parameters of diesel samples.

Diesel property       Method                   Equipment

Density             ASTM D4052       DMA 4500 automatic densimeter
                                              (Anton Paar)

Flash point          ASTM D93    PMA-4 flash point automatic analyzer
                                              (Petrotest)

Total sulfur        ASTM D4294      EDX-800 spectrometer (Shimadzu)

Distillation         ASTM D86    AD-6 automatic atmospheric distiller
                                                (Tanaka)

Cetane index        ASTM D4737                     --

Biodiesel content    EN 14078         Nicolet IR200 spectrometer
                                          (Thermo Scientific)

TABLE 2: Results of quality parameter assays using the reference
methods in accordance with ANP Resolution no. 65 [41].

Quality            Unit        Reproducibility   Repeatability
parameter

Density        kg*[m.sup.-3]     [+ or -]0.5      [+ or -]0.1
Flash point     [degrees]C       [+ or -]3        [+ or -]1
Total sulfur      % (w/w)        [+ or -]0.01     [+ or -]0.002
T10             [degrees]C       [+ or -]4.2      [+ or -]1.8
T50             [degrees]C       [+ or -]3.0      [+ or -]0.9
T85             [degrees]C       [+ or -]5.2      [+ or -]1.4
Cetane index        --           [+ or -]2.0           --
Biodiesel         % (v/v)        [+ or -]0.2      [+ or -]0.1
content

Quality               Range of             Range of        Number of
parameter            conformity            measured         samples
                                             values       nonconforming

Density            820.0 to 865.0        830.6 to 860.4         0
Flash point              38                  8 to 70           16
Total sulfur   <0.05 (a) or < 0.18 (b)    0.01 to 0.19          4
T10                    >180.0            158.9 to 234.1        75
T50                245.0 to 310.0        250.9 to 305.8         0
T85                    >360.0            247.3 to 369.5        40
Cetane index            >42.0             41.1 to 54.2          1
Biodiesel              4.5-5.5             0.6 to 7.4          41
content

(a) For S50 diesel samples, maximum sulfur content is 0.05% (w/w);
(b) for S1800 diesel samples, maximum sulfur content is 0.18% (w/w).

TABLE 3: Infrared vibrational groups of the diesel samples [42, 43].

Attribution                        Wavenumber ([cm.sup.-1])

C[H.sub.3] asymmetrical stretch              2953
C[H.sub.3] symmetric stretch                 2870
C[H.sub.3] angular deformation               1379
C[H.sub.2] asymmetric stretch                2922
C[H.sub.2] symmetrical stretch               2853
C[H.sub.2] angular deformation               1464
C[O.sub.2] asymmetrical stretch              2350
C[O.sub.2] angular deformation               667
C=O carbonyl stretch                      1750-1735
C-O stretch (aliphatic ester)             1300-1000
C=C stretch (alkenes)                     1660-1600
C=C stretch (aromatic)                  1600 and 1475
=C-H stretch (aromatic)                    900-690
S-H stretch                               2600-2550
C-S stretch                                700-600

TABLE 4: The number of outliers removed from the calibration and
validation sets.

                             Density   Flash    Total     T10
                                       point    sulfur

Calibration (273 samples)    2 (1%)    1 (1%)   2 (1%)   3 (1%)
Validation (136 samples)     3 (2%)    1 (1%)   2 (2%)   4 (3%)

                              T50      T85     Cetane   Biodiesel
                                               index     content

Calibration (273 samples)    3 (1%)   4 (2%)   3 (1%)       0
Validation (136 samples)     2 (2%)   1 (1%)   3 (2%)       0

TABLE 5: Comparison between mean center/autoscale and multivariate
filters.

                             Mean center/autoscale *

               Number   RMSEP   r (val)   X-block        y-block
               of LVs                     variance (%)   variance (%)

Density        12       0.5     0.9959    99.76          99.17
Flash point    12       2.3     0.8735    99.72          83.78
Total sulfur   7        0.013   0.9773    99.31          94.52
T10            11       4.3     0.9192    99.69          86.90
T50            7        3.5     0.9432    99.43          86.18
T85            11       4.8     0.7909    99.67          70.31
Cetane         10       0.6     0.9084    99.63          83.02
index
Biodiesel      10       0.2     0.9337    99.71          88.50
content

                                Multivariate filter

               Number   RMSEP   r (val)   X-block        y-block
               of LVs                     variance (%)   variance (%)

Density        9        0.5     0.9957    99.99          99.14
Flash point    8        2.3     0.8761    99.99          83.20
Total sulfur   6        0.013   0.9806    99.99          95.05
T10            9        4.2     0.9224    99.99          88.04
T50            6        3.2     0.9508    89.92          89.47
T85            8        4.7     0.7991    99.98          66.18
Cetane         9        0.6     0.9103    99.99          83.78
index
Biodiesel      5        0.2     0.9302    97.13          89.85
content

* The models for density, cetane index, and biodiesel content were
preprocessed using mean centering.

TABLE 6: PLS models using different variable selection approaches.

Variable    Number of     Number of LVs    RMSEP   r (val)
selection   variables        Density

None           1738             9          0.50     0.996
Manual         1124            10          0.55     0.995
FiPLS          225              8          0.46     0.997
BiPLS          1363             8          0.49     0.996
GA             439              9          0.43     0.997
                         Sulfur content
None           1738             6          0.013    0.981
Manual         1124             6          0.014    0.976
FiPLS          175              5          0.011    0.987
BiPLS          1363             7          0.011    0.985
GA             434              7          0.011    0.986
                               T50
None           1738             6          3.20     0.951
Manual         1124             5          3.24     0.951
FiPLS           75              8          3.26     0.949
BiPLS          1638             6          3.10     0.954
GA             410              5          2.97     0.957
                          Cetane index
None           1738             9          0.64     0.910
Manual         1124             8          0.63     0.912
FiPLS          225              7          0.62     0.914
BiPLS          1363             7          0.61     0.917
GA             405              6          0.62     0.914

Variable    Number of      Number of LVs      RMSEP   r (val)
selection   variables       Flash point

None           1738              8            2.30     0.876
Manual         1124              7            2.20     0.888
FiPLS          300               6            2.23     0.885
BiPLS          1663              8            2.19     0.889
GA             380               7            2.17     0.889
                                T10
None           1738              9            4.19     0.922
Manual         1124              10           4.16     0.923
FiPLS          350               8            4.24     0.920
BiPLS          1563              10           4.13     0.925
GA             370               9            4.24     0.921
                                T85
None           1738              8            4.70     0.799
Manual         1124              8            4.78     0.793
FiPLS           75               6            4.90     0.775
BiPLS          1088              10           4.75     0.797
GA             395               6            4.81     0.788
                         Biodiesel content
None           1738              5            0.21     0.930
Manual         1124              9            0.20     0.936
FiPLS          150               8            0.21     0.932
BiPLS          873               8            0.20     0.935
GA             452               6            0.20     0.937

TABLE 7: Validation results of prediction models for quality
parameters of diesel.

                         Density        Flash         Sulfur
                                        point        content

Unit                  kg x [m.sup.-3]   [degrees]C     % (w/w)
Measured interval       831.6 to       8 to 70     0.01 to 0.19
                          860.4
Variable selection         GA             GA          FiPLS
Number of variables        439           380           175
Number of LVs               9             7             5
Accuracy
RMSEC                      0.4            2            0.01
RMSECV                     0.5            2            0.01
RMSEP                      0.4            2            0.01
r (cal)                   0.997         0.930         0.987
r (CV)                    0.996         0.900         0.984
r (val)                   0.997         0.889         0.987
ARE (%)                   0.04           3.72         14.10
RPD                       12.89          2.19          5.93
Linearity
[R.sup.2] cal             0.994         0.866         0.974
[R.sup.2] CV              0.993         0.809         0.969
[R.sup.2] val             0.994         0.791         0.974
Bias                      0.002         0.049         -0.002
[t.sub.bias]              0.05           0.26          2.20
Intermediary               1.5            2            0.01
precision
RSD (%)                   0.04           5.91          9.00

                         T10          T50          T85

Unit                  [degrees]C   [degrees]C   [degrees]C
Measured interval      158.9 to     256.3 to      330 to
                        234.1        305.8        369.5
Variable selection      BiPLS          GA          None
Number of variables      1563         410          1738
Number of LVs             10           5            8
Accuracy
RMSEC                    3.9          3.0          4.6
RMSECV                   4.4          3.4          5.1
RMSEP                    4.1          3.0          4.7
r (cal)                 0.940        0.954        0.814
r (CV)                  0.922        0.941        0.770
r (val)                 0.925        0.957        0.799
ARE (%)                  1.68         0.77         1.06
RPD                      2.63         3.44         1.64
Linearity
[R.sup.2] cal           0.883        0.909        0.662
[R.sup.2] CV            0.851        0.886        0.593
[R.sup.2] val           0.855        0.916        0.639
Bias                    0.325        0.340        0.822
[t.sub.bias]             0.91         1.33         2.06
Intermediary             1.9          1.5          2.1
precision
RSD (%)                  0.93         0.44         0.47

                         Cetane      Biodiesel
                         index        content

Unit                       --         % (v/v)
Measured interval     42.2 to 51.0   0.6 to 7.4

Variable selection       BiPLS           GA
Number of variables       1363          452
Number of LVs              7             6
Accuracy
RMSEC                     0.6           0.2
RMSECV                    0.6           0.2
RMSEP                     0.6           0.2
r (cal)                  0.919         0.946
r (CV)                   0.903         0.936
r (val)                  0.917         0.937
ARE (%)                   0.95          3.18
RPD                       2.49          2.83
Linearity
[R.sup.2] cal            0.845         0.894
[R.sup.2] CV             0.815         0.877
[R.sup.2] val            0.841         0.878
Bias                     -0.086        -0.037
[t.sub.bias]              1.66          2.16
Intermediary              0.4           0.1
precision
RSD (%)                   0.40          0.95

* t critical (95% confidence level; 135 degrees of freedom) = 1.98.
COPYRIGHT 2018 Hindawi Limited
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2018 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Research Article
Author:Nespeca, Maurilio Gustavo; Hatanaka, Rafael Rodrigues; Flumignan, Danilo Luiz; Oliveira, Jose Eduard
Publication:Journal of Analytical Methods in Chemistry