Printer Friendly

Protocols for confirmation of reactive rapid HIV tests.

On November 7, 2002, the Food and Drug Administration (FDA) announced approval of the OraQuick[R] Rapid HIV-1 Antibody Test (OraSure Technologies, Inc., Bethlehem, Pennsylvania) for use by trained personnel as a point-of-care test to aid in the diagnosis of infection with human immunodeficiency virus type 1 (HIV-1). Subsequently, two other rapid HIV tests have been approved by FDA: the Reveal[TM] HIV-1 Antibody Test (MedMira Laboratories, Halifax, Nova Scotia) and the Uni-Gold Recombigen[TM] HIV Test (Trinity Biotech, Wicklow, Ireland).

All reactive rapid HIV test results require confirmatory testing. CDC described protocols for confirming reactive rapid HIV tests based on a consultation convened in January 2003 with expert laboratory scientists, FDA, and the Centers for Medicare and Medicaid Services (1). These protocols recommend 1) confirmation of all reactive rapid HIV test results with either Western blot (WB) or immunofluorescent assay (IFA), even if an enzyme immunoassay (EIA) screening test is negative, and 2) follow-up testing for persons with negative or indeterminate confirmatory test results, with a blood specimen collected 4 weeks after the initial reactive rapid test result.

In September 2003, CDC initiated postmarketing surveillance in 14 state and local health departments to monitor the performance of the OraQuick[R] test. Follow-up was attempted for all persons with reactive OraQuick[R] tests who had either nonreactive EIAs or negative or indeterminate WB or IFA results. For the 21 such persons who were identified through the surveillance system (Table), follow-up testing was initiated at the testing sites' reference laboratories only as a result of postmarketing surveillance; test results are available for 13 of these persons.

At least five HIV-infected persons were informed incorrectly that their rapid HIV test results were false-positive. Several public health and commercial laboratories contacted during this same period also indicated that they did not perform WB or IFA on OraQuick[R]-reactive specimens if the laboratory EIA was nonreactive. Additional persons might have received erroneous results from incomplete confirmatory testing.

CDC emphasizes that reactive rapid HIV tests must be confirmed with WB or IFA, even if a subsequent EIA is nonreactive. If such confirmatory testing yields negative or indeterminate results, follow-up testing should be performed on a blood specimen collected 4 weeks after the initial reactive rapid HIV test result.

Reference

(1.) CDC. Quality Assurance Guidelines for Testing Using the OraQuick[R] Rapid HIV-1 Antibody Test. Available at http://www.cdc.gov/hiv/ rapid_testing/materials/qa-guide.htm.

COPYRIGHT 2004 U.S. Government Printing Office
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2004 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Publication:Morbidity and Mortality Weekly Report
Geographic Code:1USA
Date:Mar 19, 2004
Words:402
Previous Article:National Colorectal Cancer Awareness Month.
Next Article:Table. Test results for persons with reactive OraQuick[R] tests and discordant confirmatory test results.
Topics:

Terms of use | Privacy policy | Copyright © 2022 Farlex, Inc. | Feedback | For webmasters |