Precise injection control for disc arthroplasty.

Debilitating back pain is a serious condition that affects millions of Americans. While traditional treatments are quite invasive, resulting in long recovery times, recently developed therapies are leading to better alternatives. This article illustrates how a sensor is contributing to the success of one such therapy.

Many people suffer from mild to severely debilitating back or back-radiated leg pain. Physicians estimate that four out of five Americans will complain of back pain at some time in their lives. Though people do experience temporary pain from no clear cause or after muscle strain, injury to the spine or damage from arthritis and aging are essentially permanent and are more difficult to treat with noninvasive therapy and medication.

The spine is composed of 22 or more bony vertebrae separated by shock absorbers called intervertebral discs that are formed of two types of cartilage. The discs cushion shock loads on the spine and allow movement for twisting and bending the body (articulation). Each disc is comprised of a gel-like inner material, called the nucleus, surrounded by a strong, fibrous outer rim called the annulus. The annulus contains the nucleus and allows it to withstand static loads up to 130 lb/in. (2) and dynamic loads that are much higher. A herniation (hole) in the annulus can allow the nucleus to extrude from the disc space between the vertebrae and press on trunk nerves, causing severe pain or loss of sensation.

Injury, aging, or other conditions can cause the nucleus to dehydrate and shrink, creating a condition known as degenerative disc disease (DDD). When the disc shrinks, space between the two adjacent vertebrae closes and can apply pressure on the spinal nerves radiating from the spinal cord at that junction to cause the pain associated with DDD. In severe disease, the vertebrae may even come in contact during certain motions.

Herniation and mild cases of DDD may be treated initially with bed rest and medication for pain and inflammation. Nucleus material may also be removed surgically (a micronuclectomy) to relieve pressure on a nerve. In advanced cases, traditional therapy has offered only surgical fusion (arthrodesis) of the two adjacent vertebrae into one solid bone. The technique involves major surgery, either from the back or the front of the patient, or sometimes both. First the joint is fixed, so it can't move, by some mechanical means. Then bone grafts made using bone from the pelvis or some other location, or from cages that encourage bone growth, are inserted. Once the bone has grown to solidify the joint, movement is limited and, hopefully, the lack of motion relieves pain. This technique is very invasive, can take up to a year for recovery, and can have mixed results. Adjacent non-treated discs may see increased stress of up to 30%, possibly accelerating degeneration of those joints.

Devices for total disc replacement with an artificial disc have been approved recently in the US and Europe. But this approach is at least as invasive as fusion and involves significant recovery time.

Newer approaches, particularly spine arthroplasty, provide non-fusion therapy that reduces invasion, and restores motion to the disc. Such therapies include nucleus replacement, dynamic stabilization, and facet joint replacement, as well as annulus and nucleus repair and regeneration. One type of spine arthroplasty, called disc arthroplasty, has been developed to where the patient can experience only a small incision to gain access to the affected area and replace the disc nucleus. Called the Dascor Disc Arthroplasty System, the proprietary procedural technique and synthetic nucleus materials were developed by Disc Dynamics (DDI) in Eden Prairie, MN. Disc Dynamics received a CE mark in July of 2005 and US clinical trials are planned for the near future. With Dascor, the bone of the spine and the muscles surrounding the spine are relatively undisturbed, accelerating recovery. Procedurally, the nucleus material is removed completely and replaced with an artificial nucleus that restores the proper gap height between the vertebrae with a patient-specific implant.

The first clinical version of injector used to deploy the Dascor artificial nucleus was based on pneumatics that required the operator to manipulate numerous separate controls. Disc Dynamics sought the help of Devicix, a medical design firm located in Chaska, MN, to create a much smaller, processor-based injector. A key goal was to integrate all the procedural steps into a surgical tool that could be operated easily by a single physician or trained assistant.

In less than two years, Devicix integrated software, electrical, and mechanical subsystems into a product that allows fine, closed-loop control of polymer injection via feedback from linear position and pressure sensors. Instead of the pneumatic system, a brushless motor drives a ball screw monitored by a C-Series Temposonics linear position sensor to deliver a measured quantity of the polymer at several pressure stages.

Forward and rearward travel limits are calibrated from the Temposonics C-Series position signal eliminating the need for redundant limit switches. Though the linear transducer was installed originally to provide power-up position information and calibrate a rotary incremental encoder on the drive motor, the absolute output of the Temposonics C-Series proved so resolute and reliable that the encoder was eliminated. Resolution of the implant volume is 1/4 cc out of 50 ccs, or approximately 1/2 percent. Devicix chose the Temposonics because it does not experience wear or drift over time, requires no calibration, and was easily connected to the mechanical system.

The required implant volume is calculated from a CT scan and compared by a formula in the injector with the delivered volume measured from the sensor signal. This assures the physician that the correct final size was obtained and the proper nucleus space was distracted.

By basing the injection system on micro-processor operation, DDI and Devicix were able to add more functionality. For example, the system can monitor the progress of the procedure and provide real-time feedback to the surgical team. The latest generation injector leads the user through each step of the procedure via a pendant control, tablet PC display, or voice prompts to ensure a consistent procedure and reliable filling of the implant.

ONLINE

For additional information on the products and technologies discussed in this article, see Medical Design Technology online at www.mdtmag.com and the following websites:

* www.mtssensors.com

* www.devicix.com

* www.discdyn.com

AT A GLANCE

* Causes of back pain

* Treatment options

* Arthroplasty system

* The sensor's role

RELATED ARTICLE: The temposonics C-Series sensor.

The C-Series is the smallest magnetostrictive sensor available. It is designed for higher-volume OEM applications, such as medical devices. The low cost of the C series sensors make them attractive to high-volume OEM with constrained space and budgets.

The head of the C-Series is 36 mm, 45 percent smaller than prior models. The sensor shaft diameter is 4.0 mm, with the dead zone at 18 mm and null zone at 21 mm along the shaft. The useable shaft length (active zone to overall length ratio) is at least 17.5 percent greater, so devices can be smaller and lighter. The C-Series offers enhanced sensitivity and automatic adjustment features, along with new small, compact electronics that contribute to the size reduction.

When housing is required by OEMs, such as for medical level measurement, modular options for the C-Series include a standardized IP67 housing and float, or customized housings, that can be added to the core sensor to protect it from routine, harsh, or unusual environmental factors, as well as accommodate special needs.

RELATED ARTICLE: How it works.

The inspiration behind the Dascor Disc Arthroplasty System is its curable; two-part polyurethane material and an expandable polyurethane balloon. The proprietary polymer has a compressibility and restorability very similar to healthy disc nucleus. The balloon and polymer are inserted into the disc in seven steps.

1. A small entry or access hole is made through the annulus of the diseased intervertebral disc (in the gap between two vertebrae) (A). This low degree of invasion minimizes the amount of wound to heal later and speeds recovery.

2. Bit by bit, the nucleus is removed from the disc through the access hole. Then a catheter tipped with a balloon is inserted through the hole (B).

3. The balloon is inflated with a contrast solution to the same pressure as will be used to deploy the implant. The surgeon checks the balloon via x-ray and measures to determine if the implant will be positioned correctly and to determine the final size (C). This catheter is then removed.

4. A second catheter equipped with the implant balloon is inserted into the disc space. Then liquid implant, composed of the two-part polymer mixed at an exact ratio, is pumped into the balloon (D). Once the balloon fills the disc nucleus space completely the injector automatically moves to a dwell, or curing mode.

5. The two polymer components begin to cure immediately after they are mixed (E).

6. The polymer and the balloon bond together to form a monolithic implant that is highly elastic and quickly restores the original disc function.

7. In the final step, the catheter is cut off at the edge of the implant and removed.

Jesse Russell has worked with industrial sensors for 30 years at MTS Systems, 3001 Sheldon Drive, Cary, NC 27513. He is the development manager for commercial and light industrial sensor applications. Russell can be contacted for more information at 919-677-2314 or jesse.russell@rots.com.
COPYRIGHT 2005 Advantage Business Media
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2005 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Emphasis On Sensors
Author:Russell, Jesse
Publication:Medical Design Technology
Date:Dec 1, 2005
Words:1563
Previous Article:An interview with Pat DiFlavis and Dave Roberts of Gore & Associates: as an essential part of so many medical devices, it is important for...
Next Article:Injunction against Arthrotek.
Topics:

Terms of use | Privacy policy | Copyright © 2020 Farlex, Inc. | Feedback | For webmasters