Physical-Mechanical Properties and Micromorphology of Calcium Cements Exposed to Polyacrylic and Phosphoric Acids.

1. Introduction

Calcium hydroxide cement is traditionally chosen for indirect pulp capping of deep cavities [1, 2]. In addition to low cost and ease of handling [3], self-curing calcium hydroxide cements (SCCHCs) also present the following properties: biocompatibility and alkalinity [4], ability to stimulate dentin formation [4, 5], antibacterial properties [5], thermal insulation [6], and protecting the pulp from any irritating components in restorative materials [1]. However, the physical and mechanical integrity of SCCHCs should not be affected by any further treatment performed during tooth restoration.

After indirect pulp capping with SCCHC, glass ionomer cement and/or an adhesive system are usually placed in the cavity before insertion of composite resin. Polyacrylic and phosphoric acid conditioning are recommended before the application of glass ionomer cement and etch-and-rinse adhesive systems, respectively [7, 8]. Because of the difficulty in restricting the acid application to dentin and/or enamel walls, polyacrylic and phosphoric acids may come in contact with the SCCHC, which might lead to alterations in the physical and mechanical properties of the SCCHC, despite the lack of scientific evidence on this subject.

Properties such as water sorption, solubility, and release of hydroxyl ions (pH) are related to the ability to maintain an alkaline state, which is necessary to regulate odontoblast mineralization [9], and impact resistance is detrimental to mechanical strength under compressive forces during tooth function [2, 10]. The surface roughness and morphology can indicate material degradation after exposure to external agents [11, 12]. However, there is no evidence that contact of SCCHCs containing different components with phosphoric/ polyacrylic acids does not affect water sorption, solubility, release of hydroxyl ions (pH), surface roughness, impact resistance, and morphology. The efficacy of SCCHCs as pulp capping agents would be compromised if phosphoric and polyacrylic acids affect those properties.

This study aims to evaluate the water sorption, solubility, release of hydroxyl ions (pH), surface roughness, impact resistance, and morphology of SCCHCs after contact with polyacrylic and phosphoric acids. The null hypothesis tested is that the acids would have no influence on the physical and mechanical properties tested for both cements.

2. Methods and Materials

2.1. Experimental Design. This in vitro study involved a 2 x 4 factorial design. The factors under study were material (a resin-containing SCCHC (Life (LF)) and a resin-free SCCHC (Hydro C (HyC))) and conditioning agent (polyacrylic conditioning and rinsing (POL); phosphoric acid conditioning and rinsing (PHO); rinsing only; and no treatment). The response variables were water sorption, solubility, release of hydroxyl ions (pH), and surface roughness. A secondary response variable was surface morphology. The materials used in this study are described in Table 1.

2.2. Water Sorption and Solubility. Forty disk-shaped samples (1 mm thick x 5 mm diameter) of each SCCHC were prepared using polyvinyl siloxane prefabricated molds. Then, 0.2 mL of base and catalyst pastes was dispensed on a glass plate and mixed for 10 s with a spatula until the mixture was homogeneous, according to the manufacturer's instructions. The mixture was immediately placed into the mold, which was covered with a polyester strip and a glass plate until curing.

After curing, the samples were removed from the molds and subjected to the conditioning agents (n = 10) as follows:

(i) POL: 0.1 mL of polyacrylic acid was applied on the surface of the sample for 15 s, then rinsed with distilled water (20 mL) for 15 s, and dried with oil-free air.

(ii) PHO: 0.1 mL of phosphoric acid was applied on the surface of the samples for 15 s, then rinsed with distilled water (20 mL) for 15 s, and dried with oil-free air.

(iii) Rinsing only: samples were rinsed with distilled water (20 mL) for 15 s.

(iv) No treatment: samples were not subjected to any acid or rinsing.

Water sorption and solubility analysis was performed on the samples in compliance with ISO 4049 (except for the specimen dimensions). The samples were stored in desiccators containing silica gel at 37[degrees]C and weighed daily in an analytical balance (Tel Marke, Bel Quimis, Sao Paulo, SP, Brazil) accurate to 0.001 mg, constituting a weighing cycle every 24 h. The complete cycle was repeated until a constant mass (m1) was obtained. The thickness (four measurements at four equal points on the circumference) and diameter (two measurements at right angles) of each specimen were measured using a digital electronic caliper (Mitutoyo Corporation, Tokyo, Japan). Mean values were used to calculate the volume (V) of each specimen (in [mm.sup.3]). Samples were stored in 20 mL of distilled water per sample (pH 6.46) at 37[degrees]C for 7 days and weighed after being carefully wiped with absorbent paper to record [m.sup.2]. The specimens were then returned to the desiccators. The entire mass reconditioning cycle was repeated, and the constant mass was recorded as [m.sup.3]. The values for water sorption (WS) and solubility (WSB) ([micro]g/[mm.sup.3]) were calculated using the following equations:

WS = (m2 - m3)/V, WSB = (ml - m3)/V. (1)

2.3. Roughness, Impact Resistance, and Release of Hydroxyl Ions (pH). Forty disk-shaped samples (1mm thick x 5 mm diameter) of each SCCHC were prepared and subjected to conditioning agents as described for the water sorption/solubility analyses. Samples were stored for 7 days in distilled water (20 mL, pH 6.46) at 37[degrees]C to reproduce the same storage period as for the analysis of water sorption/solubility.

Surface roughness was measured with a profilometer (Precision Surtronic 25, Taylor Hobson, UK) in [micro]m, which has a piezoelectric transducer. The measuring length of 1.25 mm and cut-off of 0.25 mm were used. Three measurements were made in the center of the samples, turning the specimen in 120[degrees], approximately, and the arithmetic mean was obtained [13].

Immediately after the surface roughness measurements, impact resistance was evaluated using a crushing strength tester (298-ATTS, Nova Etica, Vargem Grande do Sul, SP, Brazil). Samples were positioned on the apparatus to receive diametrically applied pressure. The crushing strength was obtained in newtons.

The distilled water used to store the samples was collected for the pH analysis. The pH values were determined with using a digital pH meter (PHS-3E, Jiangshu Instruments, Jiangshu, China) previously calibrated at room temperature (25 [+ or -] 2[degrees]C) with standard buffers of pH 6.86 and 4.00.

2.4. Surface Morphology. Additional samples of each SCCHC were fabricated and subjected to the conditioning agents for evaluation of the surface morphology by scanning electron microscopy (SEM). Samples were mounted on aluminum stubs with sticky double-sided conductive metal tape without special treatment. A TM 3000 table-top SEM (Hitachi High-Technologies Corporation, Tokyo, Japan) was used at 10 kV accelerating voltage. Image acquisition was performed by TM 3000 microscope software, version 02-01 (Hitachi High-Technologies Corporation, Tokyo, Japan). Images were obtained immediately after each conditioning agent was applied and after storing in distilled water for 7 days at 37[degrees]C.

2.5. Statistical Analysis. Data were analyzed by two-way ANOVA and Tukey post hoc test (P < 0.05) using the ASSISTAT beta software (UFCG, Campina Grande, PB, Brazil).

3. Results

3.1. Water Sorption and Solubility. For water sorption, ANOVA showed that there were statistically significant differences in the interaction material versus conditioning agent (P <0.05). Comparisons among the groups are listed in Table 2. For LF, POL and PHO had the lowest and highest means, respectively, although they provided similar means for the control and rinsing only. There was no statistically significant difference between conditioning agents for HyC. Comparing both materials for the same conditioning agent, only POL showed statistically significant differences; HyC had a higher mean than LF.

For solubility, ANOVA showed that there were statistically significant differences in the interaction material versus conditioning agent (P <0.01). Comparisons among the groups are listed in Table 3. For HyC, POL and PHO had the highest and lowest means, respectively, although they provided similar means for no treatment and rinsing only. For LF, POL had a statistically higher mean than other conditioning agents. Comparing both materials for the same conditioning agent, there were no statistically significant differences between them.

3.2. Roughness. ANOVA showed that there were statistically significant differences among conditioning agents (P < 0.01), between materials (P < 0.01), and in the interaction material versus conditioning agent (P <0.01). Comparisons among groups are listed in Table 4. For HyC, PHO had statistically higher means than other conditioning agents. For LF, POL and PHO had statistically lower means than rinsing only and no treatment. Comparing both materials for the same conditioning agent, LF had higher means than HyC for rinsing and no treatment. LF had a lower mean than HyC for PHO, and LF and HyC had similar means for POL.

3.3. Impact Resistance. ANOVA showed statistically significant differences between materials (P < 0.01). Comparisons among the groups are listed in Table 5. For both materials, there were no statistically significant differences among conditioning agents. Comparing both materials for the same conditioning agent, only POL had statistically significant differences between them; HyC had a higher mean than LF.

3.4. Release of Hydroxyl Ions (pH). ANOVA showed that there were statistically significant differences in the interaction material versus conditioning agent (P < 0.05). Comparisons among groups are listed in Table 6. For both cements, PHO had statistically lower means than other conditioning agents. Comparing both materials for the same conditioning agent, only PHO had statistically significant differences between them; LF had higher mean than HyC.

3.5. Surface Morphology. For the immediate analysis, the control group showed a smoother surface for HyC (AH) compared with LF (AL), despite the presence of small fissures (Figure 1). For the analysis after 7 days, structures similar to mineral components and associated with deeper fissures increased significantly in the control group (Figure 2). In the PHO group, the analysis after 7 days showed no significant difference compared with the immediate analysis for both cements; a homogenous granular appearance was maintained (Figures 1 and 2), differing only in a heterogeneous appearance in the control group. For LF, the PHO, POL, and rinsing groups presented a similar surface appearance, differing only from the control group (Figures 1 and 2). The rinsing group showed a greater difference after the 7-day analysis, changing from a uniform (Figure 1) to a fissured surface (Figure 2) for both cements. For the POL group, mineral deposits were found after 7 days, very different from control group, which presented as heterogeneous and granular (Figure 2).

4. Discussion

The null hypothesis tested in the study that polyacrylic and phosphoric acids would have no influence on the physical and mechanical properties of Hydro C and Life calcium hydroxide cements was rejected. Contact with the acids affected water sorption, solubility, roughness, release of hydroxyl ions (pH), and surface morphology of calcium hydroxide cements.

One of the most important reasons for the use of calcium hydroxide cement as a liner is that alkaline pH is maintained, even after complete curing, as a result of continuous diffusion of hydroxyl ions when in contact with dentin fluid [14]. In this study, the release of hydroxyl ions (pH) from the distilled water in which the samples were immersed for 7 days was evaluated to assess if the alkalinity potential of the material was affected by exposure strategies. All the calcium hydroxide samples were able to alkalize distilled water, except for those exposed to PHO, which were statistically different compared with the others for both LF and HyC cements. For groups exposed to PHO, the pH remained virtually the same as that of the immersion water (pH 6.46), with HyC presenting the lowest value, significantly different from LF. That result can be explained by associating the solubility of calcium hydroxide materials exposed to phosphoric acid with release of ions. It has been reported considerable resistance to solubility for this type of acid, which can explain the low release of hydroxyl ions, maintaining the pH equal to that of distilled water used and corroborating the solubility results found in the present study [15]. This low potential for alkalization exacerbated in the groups treated with PHO suggests that the biological and therapeutic effects of these cements may be reduced when touched lightly by PHO. Although both LF and HyC cements increased the pH of the immersion water, both demonstrated a low alkalizing ability, with an average pH around 7.2. This result cannot be compared with others, because most previous studies did not assess the effect of PHO on the surface of cements regarding these properties [2, 16]. Therefore, solubility and release of hydroxyl ions are related properties, as shown by the results presented here.

With regard to water sorption, HyC cement had higher mean than LF when in contact with POL. That can be explained by the association between the type of conditioning agent and the basic composition of each cement used in the experiment. A previous study [17] has shown that in the presence of resinous particles, cements such as LF appear to have greater resistance to solubility and water sorption compared with conventional cement such as HyC. That result can be also related to the results of the solubility and release of hydroxyl ion tests in our study.

With regard to surface roughness, the cements behaved differently. The surface roughness of HyC increased with PHO, whereas LF showed a reduction in surface roughness, becoming superficially smoother after PHO and POL. Comparing both cements, only the groups treated with POL were statistically similar. This result may be explained by the different chemical composition of the cements as well as selectivity of the action of the acids used. As plasticizers are the main components responsible for controlling the disintegration of the material, this explains why the results differ; HyC contains ethyl toluene sulfonamide and LF contains butyl benzene sulfonamide. A previous study [15] using cements with both plasticizing components showed the same results regarding surface integrity, corroborating our results. Thus, the resinous phase of butyl benzene sulfonamide may be less stable than that of ethyl toluene sulfonamide regarding acid etching. Therefore, for HyC cement, the selectivity of the actions of the acids generates some loss of material, resulting in superficial peaks and valleys. Furthermore, LF cement presents considerable resistance to PHO penetration [18], explaining its smoother surface. Therefore, with greater loss of material caused by plasticizing, surface roughness was statistically higher for HyC after PHO and lower for LF.

In the present study, LF and HyC presented a statistically significant difference in relation to release of hydroxyl ions only for the PHO conditioning agent, with LF showing higher means. However, PHO caused lower surface roughness on LF compared with HyC. Therefore, it is possible that the dissolution caused by this acid was responsible for greater release of hydroxyl ions, but mostly reaching the peaks rather than the valleys. Thus, the smoother surface of LF cement after PHO conditioning acid observed immediately and after 7 days corroborates the results for both surface roughness and release of hydroxyl ions.

The immediate SEM analysis of LF revealed that this cement presents a thin granular and uniform surface [16], which corroborates the higher surface roughness found in the control group, especially when compared with HyC. Small fissures were found in the SEM analysis and they were aggravated after 7 days of storage. That may be the result of loss of some minerals with time, also proposed by Gandolfi et al. [12] The samples in the rinsing group also showed similar surface roughness to the samples in the control group; therefore, it is evident that the action of the acids was responsible for the surface alterations in this cement, leading to loss of constituents, reduction in the peaks and valleys, and thereby a smoother surface.

In the analysis of the surfaces after 7 days of storage, despite the fact that PHO with HyC resulted in a homogeneous granular aspect, the mean surface roughness was higher. Therefore, filler particles on the surface of the specimens found in the other groups did not lead to greater surface roughness, shown by isolated peaks and valleys in the morphological view. However, major mineral deposits found in the control, rinsing, and POL groups for LF cement on SEM corroborate the results of the roughness test, affirming this higher mean compared with HyC, because these particular deposits of precipitated minerals were not prevalent on the microscopic analysis.

In this study, the exposure strategies did not result in a statistically significant difference in resistance to impact when analyzing one cement. However, when comparing both cements, the results were statistically similar, except for the samples treated with POL. In this case, the values for impact strength were high for HyC than for LF. Some reduction in compressive strength may be attributed to dissolution or adsorption of water during storage [17]. In this study, LF had statistically significant differences from HyC in relation to dissolution of hydroxyl ions, and therefore this would not be a possible cause for its reduced resistance. In a previous study, it was observed that LF showed low solubility in PHO (60s), high solubility in water (24h), and a compressive resistance twice as high as other cements, including Dycal [19], which is in contrast to the above statement. Thus, it can be suggested that exposure of LF to POL resulted in some loss of major constituents affecting impact resistance.

In order to see if there is a gradient of microstructure of both cements, further investigations can be performed evaluating a cross section of samples. Indeed, clinical studies on protocols for indirect pulp capping are necessary, and the results obtained in laboratory studies must be carefully applied to clinical conditions, because calcium hydroxide-based cements are significantly more soluble in distilled water than in simulated dentin fluid or saliva [17]. Furthermore, in an in vivo situation, there is a continuous exchange of fluids from dental tissue to material's surface, which rapidly dilutes the effect of the pH of the calcium hydroxide [13, 20].

5. Conclusion

The calcium hydroxide cements tested in this study showed considerable changes in their physical and mechanical properties, such as sorption, solubility, release of hydroxyl ions (pH), surface roughness, and surface morphology, when in contact with polyacrylic and phosphoric acids. Water sorption of HyC and LF cements was affected after contact with PHO and POL, respectively. The solubility of both cements was affected only by contact with POL. The impact resistance of both materials was not affected by exposure to the acids. The release of hydroxyl ions from both cements was affected by contact with PHO. Contact with both acids affected the surface roughness of LF cement; only PHO affected the surface roughness of HyC cement.

https://doi.org/10.1155/2018/3197510

Data Availability

The data used to support the findings of this study are available from the corresponding author upon request.

Conflicts of Interest

All authors declare that they have no conflicts of interest.

Acknowledgments

The work was supported by the Department of Dentistry and Pharmacy, Universidade Federal do Rio Grande do Norte (UFRN) in Natal, Brazil.

References

[1] K. C. S. Modena, L. C. Casas-Apayco, M. T. Atta et al., "Cytotoxicity and biocompatibility of direct and indirect pulp capping materials," Journal of Applied Oral Science, vol. 17, no. 6, pp. 544-554, 2009.

[2] M. A. H. Duarte, C. S. Martins, A. C. O. C. Demarchi, L. F. de Godoy, M. C. Kuga, and J. C. Yamashita, "Calcium and hydroxide release from different pulp-capping materials," Oral Surgery Oral Medicine Oral Pathology Oral Radiology, vol. 104, no. 1, pp. e66-e69, 2007.

[3] R. Weiner, "Liners and bases in general dentistry," Australian Dental Journal, vol. 56, s1, pp. 11-22, 2011.

[4] F. M. Huang, Y. C. Li, S. S. Lee, and Y. C. Chang, "Cytotoxicity of dentine bonding agents on human pulp cells is related to intracellular glutathione levels," International Endodontic Journal, vol. 43, no. 12, pp. 1091-1097, 2010.

[5] B. N. Cavalcanti, S. M. Rode, and M. M. Marques, "Cytotoxicity of substances leached or dissolved from pulp capping materials," International Endodontic Journal, vol. 38, no. 8, pp. 505-509, 2005.

[6] C. A. S. Costa, M. A. Vaerten, C. A. Edwards, and C. T. Hanks-Cytotoxic effects of current dental adhesive systems on immortalized odontoblast cell line MDPC-23," Dental Materials, vol. 15, no. 6, pp. 434-441, 1999.

[7] T. C. Fagundes, T. J. Barata, A. Prakki, E. Bresciani, and J. C. Pereira, "Indirect pulp treatment in a permanent molar: case reort of 4-year follow-up," Journal of Applied Oral Science, vol. 17, no. 1, pp. 70-74, 2009.

[8] C. A. Falster, F. B. Araujo, L. H. Straffon, and J. E. Nor, "Indirect pulp treatment: in vivo outcomes of an adhesive resin system vs calcium hydroxide for protection of the dentin-pulp complex," Pediatric Dentistry, vol. 24, no. 3, pp. 241-248, 2002.

[9] M. Kimura, T. Sase, A. Higashikawa et al., "High pH-sensitive TRPA1 activation in odontoblasts regulates mineralization," Journal of Dental Research, vol. 95, no. 9, pp. 1057-1064, 2016.

[10] L. C. Natale, M. C. Rodrigues, T. A. Xavier, A. Simoes, D. N. de Souza, and R. R. Braga, "Ion release and mechanical properties of calcium silicate and calcium hydroxide materials used for pulp capping," International Endodontic Journal, vol. 48, no. 1, pp. 89-94, 2015.

[11] L. Han, A. Okamoto, M. Fukushima, and T. Okiji, "Evaluation of physical properties and surface degradation of self-adhesive resin cements," Dental Materials Journal, vol. 26, no. 6, pp. 906-914, 2007.

[12] M. G. Gandolfi, F. Siboni, C. M. Primus, and C. Prati, "Ion release, porosity, solubility, and bioactivity of MTA plus tricalcium silicate," Journal of Endodontics, vol. 40, no. 10, pp. 1632-1637, 2014.

[13] M. de Oliveira Lima, A. Catelan, N. M. Hernandes, M. C. Giorgi, G. M. Ambrosano, and D. A. Lima, "In vitro evaluation of the effect of different polishing techniques on the surface roughness of composite resins submitted to at-home and in office bleaching procedures," Journal of Conservative Dentistry, vol. 18, no. 6, pp. 483-487, 2015.

[14] K. Gencay, F. S. S. Selvi, and B. Kiziltan, "In vitro evaluation of pH changes induced by calcium hydroxide liners," Quintessence International, vol. 35, no. 7, pp. 560-562, 2004.

[15] F. J. T. Burke and D. C. Watts, "Weight loss of three resin-based lining materials containing calcium following a phosphoric acid-etching and washing cycle," Journal of Dentistry, vol. 17, no. 1, pp. 38-40, 1989.

[16] M. G. Gandolfi, F. Siboni, T. Botero, M. Bossu, F. Riccitiello, and C. Prati, "Calcium silicate and calcium hydroxide materials for pulp capping: biointeractivity, porosity, solubility and bioactivity of current formulations," Journal of Applied Biomaterials & Functional Materials, vol. 13, no. 1, pp. e43-e60, 2015.

[17] L. F. Francisconi, A. P. Freitas, P. M. C. Scaffa, R. F. Mondelli, and P. A. Francisconi, "Water sorption and solubility of different calcium hydroxide cements," Journal of Applied Oral Science, vol. 17, no. 5, pp. 427-431, 2009.

[18] F. Garcia-Godoy, W. F. Malone, and B. K. Norling, "Acid penetration through five calcium hydroxide liners," Texas Dental Journal, vol. 103, no. 10, pp. 4-6, 1986.

[19] M. Hwas and J. L. Sandrik, "Acid and water solubility and strength of calcium hydroxide bases," Journal of the American Dental Association (1939), vol. 108, no. 1, pp. 46-48, 1984.

[20] J. Abbasi and A. B. Rahmat, "The pH variation in calcium hydroxide liners," Quintessence International, vol. 18, no. 3, pp. 225-226, 1987.

Gustavo Fernandes de Souza, (1) Ana Beatriz Arrais, (1) Cicero Flavio Soares Aragao, (2) Isana Alvares Ferreira, (1) and Boniek Castillo Dutra Borges [ID] (1)

(1) Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil

(2) Department of Pharmacy, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil

Correspondence should be addressed to Boniek Castillo Dutra Borges; boniek.castillo@gmail.com

Received 7 February 2018; Revised 6 April 2018; Accepted 16 April 2018; Published 9 May 2018

Academic Editor: Jessem Landoulsi

Caption: Figure 1: Immediate scanning electron microscopy images (400x) of Hydro C (H) and Life (L) cements with (a) no treatment; (b) phosphoric acid conditioning and rinsing; (c) rinsing only; and (d) polyacrylic acid conditioning and rinsing.

Caption: Figure 2: Scanning electron microscopy images (400x) of Hydro C (H) and Life (L) cements after storing in water for 7 days with (a) no treatment; (b) phosphoric acid conditioning and rinsing; (c) rinsing only; and (d) polyacrylic acid conditioning and rinsing.

Table 1: Materials used in this study.

Materials and manufacturer          Composition           Lot number

Hydro C (DENTSPLY Caulk,         Catalyst: calcium         064969H
Milford, DE, USA)              hydroxide, zinc oxide,
                             ethyl toluene sulfonamide,
                             zinc stearate, and mineral
                                        dyes

                                 Base: ester glycol
                                 salicylate, barium
                             sulfate, titanium dioxide,
                              silica, and mineral dyes

Kerr Life (Kerr,              Catalyst: bisacrylic and      4-1325
Karlsruhe, Germany)          trisacrylic resin, methyl
                                     salicylate

                              Base: calcium oxide and
                                     zinc oxide

Riva conditioner (SDI,        25-30% polyacrylic acid,      140355
Bayswater, Australia)          balancing ingredients

Super etch (SDI,                37% phosphoric acid,       130694Z
Bayswater, Australia)          balancing ingredients

Table 2: Means (standard deviation) of water sorption ([micro]g/
[mm.sup.3]) according to the type of material and treatment.

                         Conditioning agent

Material       No                        Polyacrylic    Phosphoric
            treatment    Rinsing only       acid         acid and
                                         and rinsing      rinsing

Hydro C        2.6             3             3.7            2.9
           (0.7) (aA)     (0.7) (aA)      (0.7) (aA)    (0.8) (aA)

Life           2.9            2.1            1.9            3.4
           (1.0) (aAB)    (0.7) (aAB)     (0.6) (bB)    (1.2) (aA)

Different capital letters represent statistically significant
differences between surface treatments of the same material (P <
0.05). Different lower case letters represent statistically
significant differences between materials for the same surface
treatment (P < 0.05).

Table 3: Means (standard deviation) of solubility ([micro]g/
[mm.sup.3]) according to the type of material and treatment.

                               Conditioning agent

                                           Polyacrylic    Phosphoric
Material   No treatment    Rinsing only    acid and       acid and
                                            rinsing        rinsing

Hydro C         1.7            2.2            2.4            1.6
            (0.7) (aAB)    (0.7) (aAB)     (0.7) (aA)    (0.8) (aB)

Life             2              2             2.3            1.8
           (1.0) (aB)      (0.7) (aB)      (0.6) (aA)    (1.2) (aB)

Different capital letters represent statistically significant
differences between surface treatments of the same material (P <
0.05). Different lower case letters represent statistically
significant differences between materials for the same surface
treatment (P < 0.05).

Table 4: Means (standard deviation) of surface roughness in Ra
([micro]m) according to the type of material and treatment.

Material                               Conditioning agent

               No         Rinsing      Polyacrylic   Phosphoric
            treatment       only       acid and       acid and
                                       rinsing         rinsing

Hydro C        0.5          0.26          0.52          1.82
           (0.25) (bB)   (0.03) (bB)   (0.22) (aB)   (0.77) (aA)

Life          3.19          3.56          0.64          0.48
           (0.15) (aA)   (0.32) (aA)   (0.23) (aB)   (0.08) (bB)

Different capital letters represent statistically significant
differences between surface treatments of the same material (P < 0
05). Different lower case letters represent statistically significant
differences between materials for the same surface treatment (P < 0
05).

Table 5: Means (standard deviation) of impact resistance in newtons
(N) according to the type of material and treatment.

                        Conditioning agent

Material      No         Rinsing     Polyacrylic    Phosphoric
           treatment       only       acid and      acid and
                                       rinsing       rinsing

Hydro C      31.0          35.9          41.7          31.4
           (9.5) (aA)   (7.6) (aA)   (10.1) (aA)    (8.9) (aA)

Life          31.9         33.1          26.9          28.4
           (6.3) (aA)   (3.5) (aA)    (3.0) (bA)    (3.7) (aA)

Different capital letters represent statistically significant
differences between surface treatments of the same material (P
<0.05). Different lower case letters represent statistically
significant differences between materials for the same surface
treatment (P < 0.05).

Table 6: Means (standard deviation) of pH according to the type of
material and treatment.

                        Conditioning agent

Material      No         Rinsing     Polyacrylic    Phosphoric
           treatment       only       acid and       acid and
                                       rinsing        rinsing

Hydro C       7.2          7.2           7.2            6.6
           (0.1) (aA)   (0.0) (aA)    (0.0) (aA)    (0.3) (bB)

Life          7.2          7.1           7.1            6.8
           (0.0) (aA)   (0.0) (aA)    (0.0) (aA)    (0.0) (aB)

Different capital letters represent statistically significant
differences between surface treatments of the same material (P
<0.05). Different lower case letters represent statistically
significant differences between materials for the same surface
treatment (P < 0.05).
COPYRIGHT 2018 Hindawi Limited
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2018 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Research Article
Author:de Souza, Gustavo Fernandes; Arrais, Ana Beatriz; Aragao, Cicero Flavio Soares; Ferreira, Isana Alva
Publication:Scanning
Date:Jan 1, 2018
Words:4709