Objective function for municipal heat supply systems' structural optimization.

UDC 681.5:658.264

Introduction. The modern market of heat supply and hot water supply (HWS) offers a wide range of various thermal energy sources: from low-power individual fan heaters, intended for rooms heating, to large TPPs and boiler facilities purposed to provide the heat and HWS to several hundred houses.

Such variety allows the end user to select between flexible variances of satisfying his needs in heat and hot water. At the apartment level the consumer can install a boiler for hot water and choose between the oil-, fan-heater or even a heat-pump system. At the house/building level the residents can install a rooftop or modular boiler plant. At the level of city district the municipal services can build a TPP arranging a central heating system or choose other ways.

As a result, each consumer, while individually solving the heat supply problem, faces the problem of process optimization. What will be better? Should he install the autonomous gas boiler, the electric boiler or shall he use the central heating system hot water? As a rule, the priorities' sequence is following: central heating, AGB, electric boiler, etc. Ideally, that distribution makes sense, but let we consider the following conditions limiting the selection options:

--the consumer has already spent a certain limit of gas and now shall be switched to a more expensive tariff;

--a multitariff electric power counter installed allows an economy as at night the consumer is switched to 40% of the nominal tariff;

--the given city district central heating system is in a deplorable state, the main pipeline leaking and its thermal insulation being wore out;

--there is an opportunity to use thermal pumps for heating both at the level of certain apartments, and at the houses group level; thus, the more powerful is that equipment, the higher is used compressors' efficiency.

Under such circumstances the optimum choice problem solution as to the heat source selection under existing conditions is less evident requiring a more serious approach. And when considering the best solution in city scale, taking into account numerous thermal power units, boiler facilities, thermal pumps feeding heat from solar collectors, geothermal sources, subsoil and sewage water, various mobile modular boiler units installed at certain houses, etc., it is obvious that the choice of the optimal for present conditions heat sources' structure will allow not only to optimize costs of municipal heat supply, but also to reveal timely the functioning thermal energy sources' deterioration.

Literature review. Nowadays the methods of variable-structure objects management are actively progressing concurrently to that objects become more complex. Solutions, representing a separate private cottage heat supply give an example of such object management realization on the basis of criteria as: heat supply quality, equipment reliability and spent resources costs, are exposed at [1,2]. The publication [3] does consider the issues of heat alternative sources' integration into municipal heat supply networks and expected potential of such systems' optimum management. To be noted is that numerous works are devoted to the problem of increasing the efficiency of end user heat supply process at the account of alternative individual sources of thermal energy [4] engaging.

In general, the global aim of all researches is the same: to elaborate such an optimal scheme when at each time-point the cheapest thermal energy source would be used. For this purpose it is necessary to have a set of alternative heat sources operated at various physical principles and using different energy resources.

Aim of the Research. The comprehensive solution of heat supply costs' optimization problem is possible in that case when the given source's thermal energy current cost formation algorithm includes whole complex of its generation costs, namely: capital expenditure for the source installation and adjustment, costs of its service maintenance and operation. Therefore, the present research purpose relates to synthesizing a complex criterion uniting all factors that define prime costs of thermal energy generated by a separate source.

Main Body. The reference [2] does suggest a variance of complex criterion synthesized on the goal-programming method basis. According to the proposed concept, each plan x of equipment switching shall be estimated using the criterion function:

[MATHEMATICAL EXPRESSION NOT REPRODUCIBLE IN ASCII], (1)

where [w.sub.r], [w.sub.q], [w.sub.s], [w.sub.e]--weight coefficient found by Delphi technique;

[R.sub.n] (x; [tau])--normalized system reliability rated value;

[Q.sub.n] (x; [tau])--normalized management quality rated value;

[S.sub.n] (x; [tau])--normalized spent resources cost parameter rated value;

[E.sub.n] (x; [tau])--normalized equipment efficiency rated value;

t--time.

The features that could be assessed as the criterion function's (1) imperfections are following:

--multicriteria optimization technique applied, this function became rather personal judgment of optimality depending on the particular person making the decision;

--the function doesn't consider all complex of capital expenditures for installation, adjustment, service and operation;

--initially every criterion function's components have their proper units of measure, and even some unification implemented, their adequate comparison is difficult to implement;

--the criterion function is used to form the plan of equipment x switching that is a resource-intensive computing task requiring to simulate a complicated multiple-factor model of environment.

Despite all shortcomings, in the absence of alternatives the heat supply system management using criterion function (1) really allows to support a certain balance between the efficiency of resources-to-thermal energy transformation, equipment reliability, quality of required temperature ensuring and the value of expenditure for resources involved. Thus the criterion function's some component priority is defined by weight coefficient.

The suggested solution is seeking to improve the criterion function (1) representing all its components through an uniform unit of measure. It allows the passage to a monocriterial optimization problem. Another key feature of this research relates, having refused to seek the forecast and equipment switching plan formation problem solution, to searching for the optimum decision for each time instance.

All criterion function components can be expressed through monetary units of measurement, the money representing an universal equivalent of goods' and services' cost.

In quality of initial data it is supposed that the generalized heat supply system has the following characteristics:

T--system resource, s;

[DELTA][tau]--simulation interval either an interval within which the system operation is assessed, s;

[C.sub.e]--equipment value;

[C.sub.ia]--installation and adjustment value;

[C.sub.s]--system servicing value for a time period T ;

[G.sup.i.sub.c]--quantity of ith energy resource consumed during the reported period (month);

[C.sup.i.sub.r] ([tau], [G.sup.i.sub.c])--current price of ith energy resource depending on day time as well as on the previously consumed energy resource quantity;

[G.sup.i.sub.r]--current expenditure of ith energy resource during the reported period (month);

[N.sub.c]--number of consumers connected.

Calculation of the criterion function's cost-related component S ([tau])

[MATHEMATICAL EXPRESSION NOT REPRODUCIBLE IN ASCII]. (2)

Depending on the given heat source type, the value [C.sup.i.sub.r] ([tau]) can be represented as UAH/kg, UAH/J, UAH/kWh, UAH/[m.sup.3]. The summation symbol at (2) does signify that some heat sources while operated are using the electrical power (e.g. for pumps function).

Further simulative modeling revealed that the [G.sup.i.sub.r] ([tau]) value does indirectly represent the energy resource--into thermal energy transformation efficiency. As a rule, all heat sources structurally are designed in a manner maintaining the required temperature at the heating element's output (should it be the furnace either thermoelectric heater). The consumed quantities and heat carrier temperature at the system being known, we can calculate theoretically the required thermal energy quantity, needed for heat carrier heating. Meanwhile the thermal processes' shortcomings as well as various thermal an physical heat carrier's losses result is actually greater energy amount required for heat carrier heating. The [G.sup.i.sub.r] ([tau]) value represents the actual energy resource expenditure immediately determining the changes of thermal energy cost when that energy production efficiency changed.

To represent the reliability characteristic in money units equivalent, it is suggested to us the actuary mathematics' methods applied at insuring to calculate the tariffs for high risk insurances [5].

The initial data:

[[bar.S].sub.n]--average insurance coverage of one agreement;

[bar.Q]--average indemnification per one agreement;

N--total number of agreements concluded during some preceding period;

M--insured occurrences number at N agreements;

p--probability of one agreement insured occurrence arising;

n--quantity of insurance agreements proportioned to the time period for which the insurance coverage is provided.

The probability of one agreement insured occurrence arising:

P = M/N.

In the absence of p, [[bar.S].sub.n], [bar.Q] values' statistics, they can be assessed by Delphi method or substituted with analogous parameters. So, the insured occurrence probability p we can replace with a value reciprocal to the heat energy source' reliability p = 1 - P([tau]) . The average insurance coverage per on agreement [[bar.S].sub.n] can be approximated as equal to capital costs for purchase, installation and adjustment divided to the consumers number:

[[bar.S].sub.n] = [C.sub.e] + [C.sub.ia]/n.

Essential to note is the insurance agreements number doesn't always enter in direct correlation to the connected consumers numbers [N.sub.c]. Case of district boiler facility, such approximation is well-reasoned as, when equipment failure to compensation should be paid to every subscriber; and case of individual heat sources, advised is to estimate some limited totality of subscribers, e.g. a living house.

The sought reliability index represented in money equivalent can be found on the net-premium basis [T.sub.n].

[T.sub.n] = [T.sub.0] + [T.sub.p], (3)

where [T.sub.0]--net-premium main part;

[T.sub.p]--risk loading.

[T.sub.0] = p [bar.Q]/[[bar.S].sub.n] = (1 - P([tau])) [bar.Q]/[[bar.S].sub.n], (4)

[T.sub.p] = 1,2 [T.sub.0][alpha]([gamma]) [square root of 1 - p/np] = 1,2 [T.sub.0] [alpha]([gamma]) [square root of P([tau])/n(1 - P)([tau]))], (5)

where [alpha]([gamma])--coefficient depending onto safety guarantees [gamma] (to be selected from reference tables).

The resulting from (3) net-premium value represents a share of relative insurance sum. In quality of such relative insurance advisable is to admit the summary capital costs for installing and adjusting the thermal energy source.

According to the actual techniques of tariffs calculation the lower limit of relation between [bar.Q] and [[bar.S].sub.n] at (4) shall be within scale from 0,3 (medical insurances) up to 0,7 (liability insuring) [5]. In our case these values' relation can symbolize some heat supply quality criterion. When the final consumer suffers from thermal energy deficiency, he is forced to bear some additional costs (e.g. to purchase alternative thermal power sources). Such expenses must be repaid by the principal heat supplier. At that the [bar.Q] and, consecutively, the relations [bar.Q]/[[bar.S].sub.n] do increase. Under circumstances of qualitative heat supply the [bar.Q], time elapsing, decreases.

Further we suppose to investigate the possibility of using the ratio [bar.Q]/[[bar.S].sub.n] to assess the process heating quality. In this paper, it was assumed to be 0,7.

The calculation of reliability component R([tau]) can be carried out for some [DELTA]T, a period equal to the month, quarter, year and thus take into account changes in the system reliability when an accident occurred.

In general, the reliability component, taking into account (3) ... (5) is:

R([tau]) = ((1 - P([tau])) 0,7 (1 + 1,2 [alpha]([gamma]) [square root of P([tau])/n(1 - P)([tau]))])) ([C.sub.e] + [C.sub.ia]) [[DELTA].sub.[tau]] /[DELTA]T

Proposed is to calculate the equipment failure-free operation probability P(t) by the method described in [2] when the equipment reliability is determined by two kinds of failures: random and wear-dependent, and depends on the environment condition and the relative power of equipment operation.

Further analysis revealed that this objective function can exclude the quality component.

When several alternative heat sources, the required temperature can be maintained always, controlling the amount of sources engaged. If heated premises' overheating occurs, (for example, in the case of central heating system) the point temperature is maintained by venting excess heat to the environment via a ventilation system. In this case, the consumer pays the entire cost of recoverable thermal energy, and, consequently, the unit cost per heat unit may exceed the cost of heat from alternative sources, that should lead to a change in the heating system structure.

Thus, the modified form of the objective function (1) is:

J ([tau]) = S ([tau]) + R([tau]). (6)

All components are expressed in monetary units, and hence the optimal solution search refers to choosing at every moment the cheapest source of thermal energy. If it is not sufficient to ensure a required temperature, we proceed to further selection of the next source with minimal cost of power generation.

Results. We consider a generalized district of the Odessa city consisting of 200 houses 72 apartments at each. Heat losses per one house at -18 [degrees]C are reaching 200 kW, that results in average heat loss per one apartment about 2,8 kW. Let the district is heated with one boiler facility. As an alternative, we assume that each apartment is equipped with a gas boiler, electric boiler and heat pump at that the boiler covers only the HWS need. Also we assume that the house has a rooftop boiler. The energy tariffs are given in Table. 1...3. Tariffs rates are as of 02/01/2014.

The fresh water supply tariff in Odessa city makes 2,736 UAH/[m.sup.3].

Let the thermal power sources' characteristics are following:
Table 4

Thermal power sources' principal characteristics

Thermal energy source      Resource,    Summary capital
                             years     expenditures, UAH

District boiler facility      25           13000000
Rooftop boiler facility       25            400000
Gas boiler                    15             10000
Electrical boiler             10             3000
Heat pump                     10             6000

Thermal energy source      Reliability   Efficiency

District boiler facility      0,999         0,98
Rooftop boiler facility       0,999         0,96
Gas boiler                    0,999         0,75
Electrical boiler             0,999         0,95
Heat pump                     0,999           *

* the heat pump thermal expansion coefficient depends onto the
ambient environment' temperature


We assume that the simulation interval Ax is 120 seconds. At that the central heating, hot and cold water in Odessa are supplied at fixed value 365,58 UAH/Gcal, 20,186 UAH/[m.sup.3] and 2,736 UAH/[m.sup.3], respectively.

Table 5 does expose the calculations results as to the minimum and maximum cost of heating and hot water using the expression (6) for different heat energy sources. To simply the comparison, the heating system results are expressed in UAH/Gcal, and the hot water in the UAH/[m.sup.3].

Conclusions. The obtained results analysis leads to several important conclusions.

The proposed optimal management objective function takes into account as the thermal energy final cost integral components such factors as capital expenditure for required equipment purchase, installation, commissioning and maintenance, its equipment reliability and efficiency. At that this optimization problem is reduced to a monocriterial one. An optimal solution is taken by selecting at each time point the heat source or heat supply system structure that allow obtaining the final product (heat, hot water) at a minimal cost.

The heating system combining various alternative sources of heat (which consume different primary energy), potentially allows when threshold quantity of some energy source used (that defines transition to a more expensive tariff), switching to heat sources, that use another kind of energy source with cheaper current tariff.

A promising solution in this respect is to use a 3-zone electrical power tariffs allowing to accumulate at night the thermal energy generated by electric heat sources, especially heat pumps.

DOI 10.15276/opu.1.45.2015.22

References

[1.] Maksimenko, I.N., Davydov, V.O. and Maksimova, O.B. (2006). Analysis of disturbances for the study of heat supply automated control systems. Refrigeration Engineering and Technology, 1, 89-92.

[2.] Babich, S.V., Maksimova, O.B. and Davydov, V.O. (2014). Management of physical objects in engineering systems. Journal of Automation and Information Sciences, 3, 50-60.

[3.] Verda, V., Guelpa, E., Kona, A. and Lo Russo, S. (2012). Reduction of primary energy needs in urban areas trough optimal planning of district heating and heat pump installations. Energy, 48(1), 40-46.

[4.] Kozlov, S.A. (1996). Energy conservation in heat supply systems. Tyazheloe Mashinostroenie, 1, 36-37.

[5.] Shcherbakov, V.A. and Kostyaeva, E.V. (2007). Insurance. Moscow: KNORUS.

[TEXT NOT REPRODUCIBLE IN ASCII]

Received September 30, 2014

S.V. Babich, V.O. Davydov, PhD, Assoc.Prof., Odessa National Polytechnic University
Table 1
Natural gas consumption tariffs

                  When annual gas     When annual gas
                 consumption below   consumption below
                  2500 [m.sup.3]      6000 [m.sup.3]

Price per 1            0,725               1,098
[m.sup.3], UAH

                  When annual gas      When annual gas
                 consumption below   consumption exceeds
                  12000 [m.sup.3]      12000 [m.sup.3]

Price per 1            2,248                2,686
[m.sup.3], UAH

Table 2
Electrical power consumption tariffs

                             When monthly        When monthly
                           consumption below   consumption below
                              150 kWt x h         800 kWt x h

Price per 1 kWt x h, UAH        0,2802              0,3648

                              When monthly
                           consumption exceeds
                               800 kWt x h

Price per 1 kWt x h, UAH         0,9576

Table 3
Tariff coefficients for electrical power differentiated 24-hours round

Tariff zone         limits          coefficient

Pique         from 08-00 to 11-00       1,5
              from 20-00 to 22-00
              from 07-00 to 08-00
Semipique     from 11-00 to 20-00       1,0
              from 22-00 to 23-00
Night         from 23-00 ro 07-00       0,4

Table 5
Results of calculating the minimum and maximum cost of heating and hot
water for different energy sources

Source                                     [J.sub.min],   [J.sub.max],
                                             UAH/Gcal       UAH/Gcal

Heating

Gas boiler                                     34,0           36,6
Thermal pump (electrical energy               325,5           1041
  standard tariff)
Thermal pump (electrical energy 3-zones       177,3           1547
  tariff)
Rooftop boiler unit                            85,5           87,6
District boiler facility                       365            365

Hot-Water Supply

Gas boiler                                     9,3            25,0
Thermal pump (electrical energy standard       11,6           54,0
  tariff)
Thermal pump (electrical energy 3-zones        7,5            79,4
  tariff)
Electrical boiler (electrical energy           20,2           59,0
  standard tariff)
Electrical boiler (electrical energy           11,7           88,3
  3-zones tariff)
Rooftop boiler unit                            9,3            21,5
District boiler facility                       20,2           20,2
COPYRIGHT 2015 Odessa National Polytechnic University
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2015 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Author:Babich, S.V.; Davydov, V.O.
Publication:Odes'kyi Politechnichnyi Universytet. Pratsi
Article Type:Report
Date:Mar 1, 2015
Words:3077
Previous Article:Development of CAD implementing the algorithm of boundary elements' numerical analytical method.
Next Article:Influence of components structure and composition of binary mixtures of organic compounds on toxicity towards daphnia magna.
Topics:

Terms of use | Privacy policy | Copyright © 2022 Farlex, Inc. | Feedback | For webmasters |