Optical Microscope near-field scanning

Fully integrated, near-field scanning optical microscope system is based around technology of the NanoScope AFM controller and the Zeiss Axiovert 135 inverted optical microscope. High efficiency optics and integrated detectors allow simple, high-resolution transmission and fluorescence maps in addition to topography on the nanometer scale. Fiber sensors with micromachined apertures guaranteed to be [is less than] 100 nm, and integrated shear-force sensors are also available. System is designed to incorporate an acousto-optic laser module that allows simultaneous mixing of multiple wavelengths, and eliminates the need to couple the laser to the fiber. The novel integration of the fiber scanner unit in the condenser lens allows both conventional farfield microscopy and near-field microscopy of the same area of the sample. Digital Instruments, Veeco Metrology Group, 112 Robin Hill Rd., Santa Barbara, CA 93177.

Write In 152 - Or Reply Online

Rugged ATR with germanium crystal

Thunderdome Swap Top module has been introduced as part of proprietary Foundation Series FI-IT sample analysis accessory line. Series shares a common base module which fits into a spectrometer, and maintains purge and proper alignment. The module offers ragged performance comparable to faceted diamond accessories, but instead uses germaninm. Germanium is strong in chemical resistance, attacked only by Aqua Regia and hot sulfuric acid. Dome sampling surface and easy-to-use pressure tower combine to make it simple to obtain a good spectrum on the very first try. Spectra-Tech, Inc., 2 Research Dr., Shelton, CT 06484.

Write In 153 - Or Reply Online

GC-MS Software Applications for combined experiments

GRAMS/32 Version 5.22 update includes the GC-MS applications pack, and many enhanced features. Powerful applications allow scientists to display and analyze data from combined GC-MS experiments. Spectral DB is a desktop tool for managing spectral and chromatography data. It is supported by proprietary SmartConvert technology, giving it the unique capability of being a repository of data files from hundreds of different analytical instruments. Galactic Industries Corp., 395 Main St., Salem, NH 03079.

Write In 154 - Or Reply Online

Vacuum Gauges measure to 1 x [10.sup.-9] Torr

Two vacuum gauge modules are now available with DeviceNet interface. One module, for the low vacuum range, is based on the industry-standard Convection Gauge. The other module, for high vacuum, is based on the popular all-metal dual-filament Micro-Ion gauge. Together, these gauges cover a measuring range from atmosphere to 1 x [10.sup.-9] Toll. Modules are a convenient, economical solution for vacuum measurements where front panel controls are not needed, and the vacuum system is controlled by computer. Helix Technology Corp., Nine Hampshire St., Mansfield, MA 02048.

Write In 155 - Or Reply Online

TOF-ICP-MS for detection of rapid transit events

Renaissance TOF-ICP-MS offers the ability to generate and report data for over 100 isotopes simultaneously in as little as 12.75 ms. This type of data collection is ideally suited for the detection of rapid transient events such as those obtained from particulate inclusions in plastics and in fingerprinting identification of solid samples. Newly updated data evaluation software allows for easy evaluation and interpretation of large amounts of information generated by the system. Software can be used to overlay multiple mass spectra, samples, and data points. LECO Corp., 3000 Lakeview Ave., St. Joseph, MI 49085.

Write In 345 - Or Reply Online

Digital Imaging System for electrophoresis gel documentation

Electrophoresis Documentation and Analysis System 290 provides improved technology for gel documentation and analysis. It can take a high-resolution electrophoresis gel image and preview on screen in seconds, quickly process and analyze the image, and prepare for publication or presentation. Users then have the option of storing the image and data electronically, importing them into another document for presentation or publication, or electronically sharing it with colleagues. The DC290 digital camera, key component of imaging system, is capable of capturing digital images with resolution in excess of 2 million pixels. The 1D Image analysis software, used to analyze and annotate images, provides users with mass and molecular weight measurements, intensity data, and ROI measurement. New hood designed for the system improves workflow and eliminates the need for a darkroom or a copy stand. Eastman Kodak, 4 Science Park, W. New Haven, CT 06511.

Write In 346 - Or Reply Online

Autosampler Syringes sampler specific design

Each autosampler syringe is designed and crafted for its intended autosampler function, guaranteeing ease of installation and extended trouble-free operation, They have a unique plunger design to eliminate bending and seizing. Needle point style is developed specifically to withstand multiple and fast septum injections. Specific models are available for Varian, Shimadzu, Agilent, PerkinElmer and CTC/Leap autosamplers in volumes ranging from 0.5 m 1 to 25 m 1. SGE, Inc., 2007 Kramer Lane, Austin, TX 78758.

Write In 167 - Or Reply Online

Heating/Refrigerating Circulators with safety features

Lauda Ecoline 300 Series Heating and Refrigerating Circulatorsare designed for safety with features including independent low-liquid-level safety shutoff, adjustable over-temperature safety, and an audible alarm. A programmable controller for up to ten temperature-time segments includes Lauda Wintherm software. Control accuracy is [+ or -] 0.01 C. Heating circulators have a temperature range of ambient to 200 C. Refrigerating models have a temperature range of -30 C to 200 C. Brinkmann Instruments, Inc., Cantiague Rd., Westbury, NY 11590.

Write In 168 - Or Reply Online

Chemiluminescence Detector for HPLC

The Shodex CL-2 chemiluminescence detector has been especially designed for ultra high sensitive HPLC analyses using a novel single photoelectron counting system. Detection limits are the attomole level, which is significantly more sensitive than conventional detectors such as UV, RI and fluorescence. The model uses a post-column reaction system with a spiral-type flow cell, resulting in wide linear dynamic range and very low cost per analysis. Easy-to-operate ragged design can be used with all HPLC systems. JM Science, Grand Island Research Park, 355 Lang Blvd., Grand Island, NY 14072.

Write In 169 - Or Reply Online

Arsine Standards permeation tubes

Series 57 Arsine Permeation Tubes are used in proprietary Gas Standards Generators to produce arsine standards ranging from [is less than] 50 ppb to 5 ppm. Tubes are 6" long x 1 3/4" diameter stainless steel cylinders containing a permeation membrane. Each tube is pre-filled with less than 4 grams of arsine, which eliminates the need for high-pressure cylinders that contain much larger quantities of the hazardous material. When placed in the Gas Standards Generator and held at a constant temperature, tube produces a verifiable, low concentration gas standard. Tube is supplied with a specially designed purge kit, which allows user to store the tube safely. KIN-TEK Laboratories, Inc., 504 Laurel, La Marque, TX 77568.

Write In 170 - Or Reply Online

Calibration Kit for lab and field

Mini-Cal Kit for on-the-spot calibration is offered in two configurations. CCOIL consists of two low pressure, steel, 1-liter cylinders, best suited for gas, natural gas liquids and refinery gases. CC1AL contains one high-pressure aluminum, 1-liter cylinder ideal for reactive or high-pressure standards. Either brass or stainless steel regulators for each application provide stable, precise pressure controls. Rugged black resin case has a protective custom die-cut foam lining. DCG, 4170A Main, Pearland, TX 77581.

Write In 171 - Or Reply Online

Temperature Gauge with sensor

Series BX 800 Plus Temperature Gauge and Sensor combines an easy to read local indication of a Dial Thermometer with a thermocouple or platinum RTD to enable remote indication, control or data acquisition. Series can be ordered with stem lengths of 2" to 12" and internal sensors of Type E, J, K, T thermocouples, as well as plat 100 ohm or 1000 ohm RTDs. The viewing window is made from double strength glass. Readings are accurate to within [+ or -] 1% of full scale. Vespo Marketing Associates, Inc., P.O. Box 60, Thompson Ridge, NY 10985.

Write In 172 - Or Reply Online

Temperature Recorder two-channel

KT655 Microprocessor-Based Temperature Recorder is 6" model with data logging capability. It has two Type K thermocouple probes that ensure fast and accurate temperature measurements. In addition to the paper chart record, all data can be easily downloaded to a PC for viewing, graphing or printing with Dicksonware software. All recorders feature panel and wall mount capability, DIN compatible enclosure, AC power with battery backup, programmable recording times, and 15 user-selectable temperature ranges. Dickson Co., 930 S. Westwood Ave., Addison, IL 60101.

Write In 173 - Or Reply Online

RH/Dewpoint Transmitters can be customized

HMP 230 Series of smart [+ or -] 1% RH accuracy transmitters can be customized to the user's unique needs and applications. Output parameters of RH, Td, T, absolute humidity, mixing ratio, wet bulb temperature and enthalpy can be selected, as well as temperature range, serial or analog output, and type of sensor head. Patented thin-film HUMICAP sensor provides excellent accuracy and long-term stability. It is tolerant to high temperature, can operate in condensing environments, and is resistant to harsh chemicals and contaminants. A re-gaining option returns the sensor to normal following the evaporation of chemicals from the sensor. Vaisala Inc., 100 Commerce Way, Woburn, MA 01801.

Write In 174 - Or Reply Online

Fasteners for wet environments

Fasteners for wet environments are designed and manufactured with a groove under the head to accommodate a rubber O-ring which, when compressed, forms a complete seal and permits full metal-to-metal contact. Self-sealing units provide an airtight, leakproof seal against liquids, air and other gases, and can be removed from equipment and reused without spoiling sealing action. Made of 18-8 stainless steel, fasteners are passivated per QQP-35. Screws in nominal sizes of #4 through 1/4-20 are available. Finishing options include black oxide, sand-blasted, and per customer's request. Zago Manufacturing Co., Inc., 190 Murray St., Newark, NJ 07114.

Write In 181 - Or Reply Online

Gas Dryers nafion construction

Improved PD-Series of Nation gas dryers selectively remove water from gases without removing other compounds. Unlike chiller/condenser, desiccant, and permeation dryers, these dryers do not suffer analyte loss during drying process. Nation, a chemical modification of Teflon, is selectively permeable to water, but shares chemical resistance of Teflon. Water escapes from tubing exterior continuously, reducing the sample dew point to as low as -45 C. Perma Pure, Inc., P.O. Box 2105, Toms River, NJ 08754.

Write In 182 - Or Reply Online

Flatbed Recorders for extremely low voltages

Compact, economical, single or two-channel flatbed recorders are suitable for recording voltages, especially extremely low voltages. With appropriate transducers they are also capable of recording physical, chemical and biological values. Recording can be effected in Yt or in XY mode, as well. Other features include: integrated RS232C interface, and a high data transmission rate of 128 values/sec. Davis Instruments LLC, 4701 Mount Hope Dr., Baltimore, MD 21215.

Write In 183 - Or Reply Online

Precolumn Filter fingertight

ColumnSaver precolumn filter requires no tools or assembly for installation. The disposal unit contains a 0.5 [micro] filter, and is handtight to 5000 psi. When an increase in back pressure is noticed, user must simply remove the filter and replace it with a new unit. In addition, there are no bulky fittings to interfere with installing the column in an instrument column compartment or column heater. Isolation Technologies, Inc., 4 Business Way, Hopedale, MA 01747.

Write In 184 - Or Reply Online

FTIR/FT-NIR for routine sampling applications

The Genesis II FTIR/FT-NIR provides ease of use and dependable operation for routine sampling applications. Design features such as the Quadrascan interferometer, auto-alignment, and precision-cast baseplate are incorporated to produce an extremely rugged and reliable system. Ideal for QA/QC labs, it is easily configurable in the mid or near-infrared to meet the requirements of incoming and outgoing material checks. Controlled by WinFIRST software, it is easy to customize, and includes both simple and advanced menus, methods setup, and easy macros. Mattson Instruments, 5225 Verona Rd., Madison, WI 53711.

Write In 185 - Or Reply Online

Large Bore Tubing for low pressure fluid handling

Line of large bore tubing and accessories is designed to meet needs of low pressure fluid handling applications. Tubing in outer diameters of 3/160, 1/40, and 5/160 is available in both Teflon and in Tefzel. Line also includes fittings, unions, adapters, plugs, filters and Y-connectors manufactured in materials such as PEEK and Delrin. Upchurch Scientific, 619 West Oak St., Oak Harbor, WA 98277.

Write In 190 - Or Reply Online

Valve Series manifold/sub-system

M Series of valves utilizes existing valve designs which have been engineered and developed into specialized manifold and complete sub-assembly system for scientific instrumentation or other industrial devices. As part of series, an exhaustive list of plastics and elastomer seal materials for application compatibility, custom electrical termination, choice of mounting configurations, and custom fittings for free-sanding versions is offered. Valcor Engineering Corp., 2 Lawrence Rd., Springfield, NJ 07081.

Write In 191 - Or Reply Online

PCI DAP Board for real-time processing

DAP 840/103 Model, 14-bit resolution entry-level PCI DAP board for real-time processing for Windows PCs, features a 32-bit operating system. User controls operating system with high-level commands, either locally or across a network from HP VEE, LabVIEW, DASYLab, Visual Basic, or other Windows applications software. This allows critical processes to run free from PC-related or network-related delays. Realtime functions include software triggering, data reduction, filtering, FFT, and PID control. Microstar Laboratories, Inc., 2265 116th Ave., Bellevue, WA 98004.

Write In 192 - Or Reply Online

Transmitters RH/temp/dewpoint output

Model 761 Series transmitters provide RH/temp/dewpoint/absolute humidity output. They accept a wide range of capacitive humidity and temperature sensors. Transmitters feature: programmable voltage/current/digital output modes with selectable US or EURO measurement units; full digital zero/span/cal adjust; RH ranges from 5 to 95%; and operating temperature from 0 to 300 F; and nominal accuracy from 1% to 2% RH. Ohmic Instruments Co., 508 August St., Easton, MD 21601.

Write In 193 - Or Reply Online

Chemistry Calorimeter thermally sensitive

Research calorimeter is a thermally sensitive instrument for quantitative thermodynamic and kinetic chemical measurements. Wide sensitivity and operating temperature range enable its use on most types of chemical reactions. External voltage and current ports allow NSB traceable internal calibrations at rates up to 10 watts. The Teflon constructed reaction cup system holds up to 125 ml of aqueous or organic solution. Advanced Materials Technology, Inc., 54445 Edith Blvd. NE, Albuquerque, NM 87107.

Write In 194 - Or Reply Online

X-Ray Diffractometers open-architecture design

X'Pert PRO series of X-Ray diffractometers is the successor to the X'Pert MPD and X'Pert MRD product lines. PreFix plug and play optical elements and sample stages allow the adaptation of the system from one application to another in just a few minutes, without any tedious alignment procedures. From small amounts of sample to bulky samples, this system covers the entire range. Open-design architecture guarantees full freedom to accommodate further advances. Philips Analytical, Inc., 12 Michigan Dr., Natick, MA 01760.

Write In 195 - Or Reply Online

Tabletop Autoclaves for portable steam sterilization

Tuttnauer tabletop autoclaves provide fast, safe and reliable steam sterilization for liquids, media, instruments, glassware, clothing and waste. Models are available with 7, 9, 10 or 15 inch diameter chamber and do not require special plumbing or hardwiring. Self-contained design with refillable reservoir allows control of water purity for sterilization. Standard features include high-grade 316L stainless steel chamber, drying cycle. fast and slow exhaust, and continuous pressure to insure thorough, even sterilization. All sterilizers are UL listed and ASME stamped. Brinkmann Instruments, Inc., One Cantiague Rd., Westbury, NY 11590.

Write In 196 - Or Reply Online

LiquidProcessors for SPE

Speedisk 48 positive pressure processors displace liquids at the same rote for up to 48 columns at once. Dry nitrogen or compressed air displaces liquid from all SPE columns or microplate positions at a uniform, easily controlled flow rate. A positive seal at each column inlet eliminates the possibility of cross talk between columns during processing. Regulated gas flow results in identical liquid flow at each column position without the use of additional valves or plugs. The same dry gas used to displace liquid can also be used for blow-down. J.T. Baker, 222 Red School Lane, Phillipsburg, NJ 08865.

Write In 197 - Or Reply Online

Wastewater Monitor on-line for toxicity

BIOSCAN on-line wastewater toxicity monitor continuously monitors and records the effect of treated industrial effluents on municipal wastewater treatment plants or waters receiving these wastes. Where wastes are being discharged after pretreatment to a pretreatment plant, the monitor uses a sample of activated sludge to determine treatability or inhibition to the plant. Where effluent is discharged directly to receiving waters, a broad range screening culture may be used as the reference organism. Data is continuously displayed on screen of monitor and can be downloaded to a computer. An alarm contact is provided for early warning of inhibitory or toxic conditions. N-CON Systems, 180 North St., Crawford, GA 30630.

Write In 206 - Or Reply Online

Glassware Washer greater cycle flexibility

FlaskScrubber Glassware Washer thoroughly washes and dries narrow-necked lab glassware. Water is injected directly into narrow-necked flasks and other glassware, clearing hard to reach residue, Moisture is then vacuumed from the glassware for thorough drying. Touchpad controls and LED display allow the user to change wash and dry cycle duration, as well as the number of rinses. Steam and multiple purified water rinses may also be selected. Cycle progress can be viewed on a digital display from beginning to end, and through an optional viewing window on the stainless steel door. Dual heaters boost water and glassware temperatures during all cycles. Labconco Corp., 8811 Prospect Ave., Kansas City, MO 64132.

Write In 207 - Or Reply Online

Pipette Calibration System FDA IQ/OQ requirements

PCS 3 Pipette Calibration System verifies the performance of mechanical action pipettes. It includes a complete validation guide to assist the user with installation qualification and operational qualification of the system. Labs submittin data to agencies such as the FDA must validate their equipment and related processes. With the system, a 10 data-point, fully documented, NIST traceable pipette calibration may be completed in under 3 minutes. The automatically generated printout includes individual sample delivery volumes, group statistics such as mean and CV, pipette serial number, date and operator. Model can be used with volumes from 0.1 m 1 up to 5000 m 1. ARTEL, 25 Bradley Dr., Westbrook, ME 04092.

Write In 208 - Or Reply Online

HPLC Degassing System efficient/on-line

On-Line Degassing System is the most efficient available to improve HPLC pump performance. The degassing membranes are constructed of a new amorphous fluoropolymer, Teflon AF, which allows for the highest efficiency available. Features include fast equilibration times, zero baseline fluctuation, error and leak checking functions, and low operating noise. Alltech Associates, Inc., 2051 Waukegan Rd., Deerfield, IL 60015.

Write In 209 - Or Reply Online

Wide Range Vacuum Gauge economical

OBE-2002 Vacuum Gauge provides small, low-cost method of accurate vacuum measurement over a wide range of pressure. Module contains all of the performance features of Model 2002 dual sensor instrument in a compact configuration. It features pin-to-pin compatibility with some of the most widely used convection driven Pirani gauges. It provides wide measurement range of 1 x [10.sup.-4] to 1000 Tort without multiple gauges. Teledyne Electronic Technologies Hastings Instruments, P.O. Box 1436, Hampton, VA 23661

Write In 210 - Or Reply Online

Miniature Dip Probe in UV version

Slender 1/8", low-cost, high-throughput Mini-Dip Probe reaches into much smaller vials, test tubes, well plates, and other glassware. It is available in fixed pathlengths of 2 mm, 5 mm and 10 mm. The optical fiber is 200-micron core fused silica, surrounded by a polyimide jacket. Probe is available in a UV version only. It incorporates a back reflecting aluminum mirror for high light return in the UV region. The sensitive aluminum layer is back-coated on a silica disk with a protective [M.sub.g2] overcoat. Mirror is then sealed into bottom of the probe. All wetted surfaces are silica, stainless steel or epoxy. Equitech Int'l. Corp., 1359 Silver Bluff Rd., Ste. G-6, Aiken, SC 29803.

Write In 211 - Or Reply Online

Broadband UV Mirrors utilize dielectric coating

New broadband ultraviolet minors utilize an innovative dielectric coating that maintains extremely high reflectivity over a wide spectral range. Because average reflectivity exceeds 98% from 248 to 390 nm, a single mirror can be employed for most UV applications. Flatness specifications of 14 or 110 meet the most stringent quality requirements. Round or square substrates are available. Melles Griot Photonics Components, 16542 Millikan Ave., Irvine, CA 92606.

Write In 214 - Or Reply Online

Ampoule Covers and swab tips

Ampoule covers are custom manufactured using proprietary fiber extrusion bonding processes. A prefilled glass ampoule can be enclosed inside the fiber ampoule cover and ends sealed. They offer high-quality, superior aesthetics with consistent user protection. Swab tips absorb liquids and release them at a controlled rate upon surface contact. Filtrona Richmond, Inc., 8401 Jefferson Davis Hwy., Richmond, VA 23234.

Write In 215 - Or Reply Online

Integrating Spheres in diameters to 3 m

Integrating spheres are available in sizes up to 3 meters in diameter, giving customers expanded capabilities to meet specific optical radiation measurement needs. Spheres and sphere systems are available for laser power measurement, lamp flux measurement, uniform calibration sources, and reflectance and transmittance measurements. Custom design and OEM inquiries are welcomed. Labsphere, Inc., P.O. Box 70, Shaker St., North Sutton, NH 03260.

Write In 216 - Or Reply Online

Hi-Speed Concentrator unattended operation

TurboVap 96 high-speed concentrator works with two 96-well microplates or deep-well plates. System is driven by patented gas vortex shearing action with a temperature-controlled environment and adjustable gas flowrates which saves time, bench space, and operation costs while improving evaporation speed and sample-to-sample consistency. Touch pad control retains previous settings for faster start-ups. Zymark Corp., Zymark Center Hopkinton, MA 01748.

Write In 217 - Or Reply Online

Rheometer Line permanent-magnet drive

MCR 300, modular compact rheometer provides controlled shear stress and controlled shear rate measurements, as well as oscillatory tests. Versatility and accuracy is owed to unit's permanent-magnet synchronous drive. Superior to conventional drag-cup motors, drive has been improved for the new rheometer, and built into a compact and robust casing. The result is a system that combines high-quality measurement with outstanding ease of use and flexibility that allows it to tackle a wide range of measuring tasks. Physica Messtechnik GmbH, Vor dem Lauch 6, D 70567, Stuttgart, Ger.

Write In 218 - Or Reply Online

Precast Agarose Gels portrait/landscape formats

AGILE precast agarose gels combine resolution and reproducibility with the convenience of a cassette that is also UV-transparent. Results can be seen without removing the gel from the cassette. The Gripper handle easily transports the cassette throughout the electrophoresis process, eliminating mess and the risk of tearing or contamination. Gels are available in standard and in mini sizes, in portrait or landscape formats, with TAE or TBE buffers, with or without ethidium bromide, and in 1%, 2% and 4% concentrations. They fit most commonly used electrophoresis units. J.T. Baker, 222 Red School Lane, Phillipsburg, NJ 08865.

Write In 219 - Or Reply Online

Mini Diaphragm Pump for gas analyzers/medical devices

Model 015 LC miniature diaphragm pump is an economical pressure/vacuum source for gas analyzers, medical devices, process samplers, test fixtures, pick-and-place equipment, and many general industrial applications. Mountable in any position, pump operates oil free. Available wetted parts offer excellent chemical resistance, as well as contamination-flee pumping. Wetted parts include pump head molded from Ryton, and diaphragm and valve material of EPDM, silicone, or Viton. It operates on 6 Vdc, has a maximum continuous pressure of 1.5 psig, a maximum continuous vacuum of 3.0" Hg, and a maximum flow rate of 1100 ml/min. E. Clark & Associates, P.O. Box 1000, Clinton, MA 01510.

Write in 220 - Or Reply Online

Spill Containment Caddy polyethylene construction

Gator spill containment caddies manage 30 or 55 gallons of hazardous chemicals with total compliance with EPA and OSHA regulations. Gator Tuff polyethylene construction is comparable with, and resistant to, industrial chemicals. If a spill occurs, oversized 66 gallon spill sump will contain the entire spill, thus eliminating both hassle and hazard. Large 10" wheels roll easily, while large rounded handles offer a firm, comfortable grip. Ergonomic design simplifies loading and moving a full, heavy drum. Justrite, 2454 Dempster St., Des Plains, IL 60016.

Write In 221 - Or Reply Online

Particle Size Analyzer uses digital image processing

The Camsizer, digital camera particle size analyzer, uses digital image processing to measure the particle size of free flowing parts in the range of 30 gm to 30 mm. It uses 2 matched digital cameras to ensure accurate measurement throughout entire range, and provides an analysis of particle shape as well as size. It can provide results in less than 1 minute, and is supplied with an easy-to-use, yet sophisticated Windows based software package that includes real time sample imaging. Horiba Instruments, Inc., 17671 Armstrong Ave., Irvine, CA 92614.

Write In 225 - Or Reply Online

AA Spectrophotometers flame only or furnace only

AA-6650 Series atomic absorption spectrophotometers are available in flame only or furnace only combustion modes. As solution for labs that do not require both flame and furnace, it provides the high-sensitivity and performance features of the AA-6800 model at a lower price. AA Wizard software enables easy setup of equipment, as well as measurement parameters and analysis procedures. Standard QA/QC functions ensure reliability of measured results and security of stored data. Shimadzu Scientific Instruments, Inc., 7102 Riverwood Dr., Columbia, MD 21046.

Write In 226 - Or Reply Online

Pyroelectric Detectors single-element

LIE 50x single-element pyroelectric detectors are offered in TO-39 housing with an active surface of 3 mm x 3 mm. T Series is in addition to family of standard single-element detectors with active area of 1.6 mm x 0.8 mm and 2 mm x 2 mm. All detectors have a thermally stable black absorbing layer for wide spectral response, and are suitable for use with modulation frequencies of up to 4 kHz. They are suited for applications in a spectral range from 1 gm to more than 25 gm. Laser Components, Inc, 5460 Skylane Blvd., Santa Rosa, CA 95403.

Write In 227 - Or Reply Online

Pulse Generator with 1 ns delay resolution

Model 555 multi-channel digital delay generator features 1 ns delay resolution. In addition to independent delay and width selection on each channel, it includes selectable TTL/CMOS or adjustable amplitudes up to 15 V into high impedance. Available configurations are 2, 4, or 8 channels of output. Standard features include full numeric keyboard, spinner knob, and 4-line status display. Berkeley Nucleonics Corp, 3060 Kerner Blvd. #2, San Rafael, CA 94901.

Write In 228 - Or Reply Online

Automated SPE System for LC-MS analysis

Prospekt-2 is a high-speed, SPE sample clean-up system. It features genetic protocols for greater flexibility, and dual online sample processors for sequential direct sample injection into an LC or LC-MS system. Furthermore, direct introduction of SPE eluates into the LCMS eliminates tedious manual sample handling steps. By eliminating these steps, the system increases sensitivity and provides more accurate and reproducible results. Jones Chromatography, Inc., P.O. Box 280329, Lakewood, CO 80228.

Write In 229 - Or Reply Online

Microplate Pipetting automated

Precision 2000 96/384-well automated microplate pipetting system is an affordable, solution to replace manual pipetting protocols. With configurable 6-station platform, reagent addition, plate replication, and serial dilutions are efficiently executed in both 96 and 384-well formats. Proprietary pipette technology provides a reliable way to pick up and seal any standard tip with controlled force. Flexible software facilitates very complex fluid transfers. Robotic compatibility with ActiveX control is a standard feature. Bio-Tek Instruments, Inc., Highland Park, Winooksi, VT 05404.

Write In 230 - Or Reply Online

Sputtering Sources ultra-pure thin film applications

Torus UHV sputtering sources are compatible with vacuum systems that reach base pressures below [10.sup.-10] Torr. They have no O-rings, and magnet assembly is removable without breaking vacuum allowing for 350 C chamber bakeout. Sources are equipped with unique, rare earth magnet arrays that can be adjusted in situ, allowing user to sputter both magnetic and non-magnetic target materials by optimizing magnetic field over the target's surface. Optional features include gas distribution rings and sputtering chimneys. Kurt J. Lesker Co., 1515 Worthington Ave., Clairton, PA 15025.

Write In 231 - Or Reply Online

Transilluminator for mini gels/light lab use

Nano-Lite, tiny transilluminator, is designed for safety in education as a low-budget, high-performance mini gel documentation system. It is perfect for mini gels and light laboratory use, or as a personal desktop transilluminator for a quick read of gels. Safety features include a four-sided UV blocking cover, thermal cutoff to prevent overheating, and automatic UV safety cutoff switch system. Additional features include a lightweight plastic case, power on/off light, uniform illumination specular reflector, and long life UV filter glass. Two filter sizes are available: 10 x 10 cm and 7.5 x 7.5 cm. Ultra-Lure, Inc., 6421 E. Alondra Blvd., Paramount, CA 90723.

Write In 232 - Or Reply Online

Sapphire Optics custom fabricated

Line of sapphire optics features 9 Moh surface hardness and thermal stability to 2000 C. The optics are impervious to water and most chemicals, and can withstand pressures up to 4000 psi, depending upon configuration. Manufactured to specification, they can be produced as highly spherical balls in sizes from 0.0050 to 0.50 diameter, as plano convex and plano concave shapes from 0.50 to 60 diameter, and as rectangles and squares in various thicknesses. They can be produced with flatness to 1/10 wave in the visible and [is less than] 2 arc sec in/in parallelism. They transmit from the UV to IR with up to 85% transmission uncoated and up to 99% with A/R coatings on two sides. Meller Optics, Inc., 120 Corliss St., Providence, RI 02940.

Write In 239 - Or Reply Online

Hydrogen Gas Generator ultra high purity

NITROX hydrogen gas generators are an ideal source of ultra high purity hydrogen gas for many lab applications including carrier gas for GC and fuel gas for flame ionization detectors. Using the principle of electrolytic dissociation of water, generators produce a continuous stream of ultra pure hydrogen gas at flow rates from 160 cc/min to 500 cc/min. Deionized water and an electricity supply are all that are needed for continuous, uninterrupted operation and the units are virtually maintenance-free. The generators supply gas only on demand at low pressure, thus eliminating the potential risks of high pressure gas storage, domnick hunter limited, Dukesway, Team Valley Trading Estate, Gateshead, Tyne & Wear, UK NE11 0PZ.

Write In 240 - Or Reply Online

Homogenizing Mixer reversible

Model CJ-75-3 Reversible Homogenizing Mixer meets stringent sanitary requirements of food and pharmaceutical manufacturing industries. All product contact parts are Type 316 stainless steel. Non-316 electric motor is wash down duty model that is highly resistant to corrosion and wet processing conditions. Homogenizer is used to draw in and wet out powdered solids such as mineral supplements, and difficult to disperse stabilizer such as xanthan gum. After incorporation of the solid powders, the homogenizer is reversed to provide a high velocity recirculating flow through the high shear rotor/stator mixing head. This provides extremely fine particle size distributions and complete mixing of each individual dosage. ARDE Barinco, Inc., 500 Walnut St., Norwood, NJ 07648.

Write In 241 - Or Reply Online

Self-Priming Gear Pumps metering/dispensing

Ideal for accurate metering, dispensing or transferring of fluids, gear pumps have a flow rate range to 1.5 gpm and pressures to 125 psi. Various motor options are available and pump life ranges to 10,000 hours. These positive displacement gear pumps are self-priming and ideal for instrumentation. Gorman-Rupp Industries, 180 Hines Ave., Bellville, OH 44813.

Write In 242 - Or Reply Online

Black Seal Syringes for syringe pumps

Two new syringes, 1.0 ml and 5.0 ml, for the XP 3000 Modular Digital Syringe Pump, have black seals to ensure a longer life. Seals are made of ultra high molecular weight polyethylene, rather than traditional Teflon. This harder material makes it an excellent choice for saline or other solutions that can crystallize and damage syringe seals. Cavro Scientific Instruments, Inc., 242 Humboldt Ct., Sunnyvale, CA 94089.

Write In 243 - Or Reply Online

Autosampler Vials easy to use

StepVial System provides an easy to use, reliable and cost effective sample vial for use with autosamplers. System is comprised of a sample vial and a limited volume insert with a choice of either a Poly Crimp Seal, Snap Top Cap, aluminum seal or a threaded closure. System design allows for the insert to be precisely positioned in the center of the vial neck, which eliminates any possibility of the autosampler needle jamming accidentally between the insert opening and the neck of the vial. An enlarged diameter neck opening on both the vial and insert provides a larger target area for the autosampler and facilitates manual pipetting. J.G. Finnean Associates, 3600 Reilly Court, Vineland, NJ 08360.

Write In 244 - Or Reply Online

GPC Columns for organic polymer analysis

Shodex KF-400 series GPC columns for organic polymer analysis are based on a 3 gm SDVB copolymer packing material. Several improvements over older GPC columns include: higher resolution with efficiency exceeding 100,000 plates/m; one-third less solvent use; better detection limits; and assurance of linear calibration curves. JM Science, Inc., 355 Lang Blvd., Grand Island, NY 14072.

Write In 250 - Or Reply Online

Camera Software provides improved color rendition

SPOT 3.1.0 software provides new features and improvements for the RT series of SPOT cameras including: improved color rendition, live mode zoom and gamma adjustment, and a programmable output for external shutter control. The full line of SPOT cameras are provided with: sequential images saved to a single TIFF file; a sequential image player that allows the replay of a set of sequential images with display controls; and an improved histogram function that allows zooming. Users still covered by software warranty agreement can download the new release off of the Internet. Diagnostic Instruments, Inc., 6540 Burroughs, Sterling Heights, MI 48314.

Write In 251 - Or Reply Online

Vacuum Furnace System improved hot zone design

The Plus control system for the Performer vacuum furnace system is an arrangement of precision digital controls that provide a widely expanded scope of system operation data, in a convenient and easy-to-use format. System heat treat processing cycles are configured directly on the display panel by a series of programmable steps. This includes multiple zone control along with all system information and parameters on multiple screens. The hot zone is removable for efficient operation and maintenance. Hot zone sizes are available up to 24" x 24" x 48". System is a high-vacuum heat treating system for processing at vacuum levels of [10.sup.-5] to [10.sup.-6] Torr, to 1300 C. T-M Vacuum Products, 630 S. Warrington St., Cinnaminson, NJ 08077.

Write In 252 - Or Reply Online

Fast-Set Epoxy high-temperature

Aremco-Bond 820 high-temperatures epoxy system is used for bonding of ceramics, glass, plastics, metals and other substrates in applications to 400 F. It features flexural and tensile shear strengths of 8000 and 1200 psi, respectively, and volume resistivity of 2.0 x [10.sup.14]. Epoxy mixes easily in a 1:1 ratio, providing a mixed viscosity of 12,000 cps and cure time of 45 minutes at room temperature. It is supplied in pre-filled 50 ml dispense cartridges, as well as in pint, quart, and gallon containers. Aremco Products, Inc., 707-B Executive Blvd., Valley Cottage, NY 10989.

Write In 253 - Or Reply Online

Ethernet/GPIB Integration for remote equipment access

The GPIB-ENET/100 Ethernet-to-GPIB controller and the PCI-8212 combination GPIB and Ethernet interface for PCI, offer high-speed interfaces for connecting, sharing, or controlling GPIB instruments on Ethernet networks. Both products are HS488 compliant, so engineers and scientists can achieve the best GPIB performance. With the GPIBENET/100 controller, users can easily access remote test equipment from anywhere in the world via TCP/IP protocols on 100BaseT and 100BaseT networks. By incorporating a new architecture, users achieve more than a 10x performance improvement compared to existing GPIB controllers. The PCI-8212 interface combines a GPIB controller and a standard Ethernet controller in a single PCI board to save slots in a user's computer. The GPIB computer chip is capable of transfer rates up to 8 Mbytes/s. National Instruments, 11500 N Mopac Expwy., Austin, TX 78759.

Write In 254 - Or Reply Online

Particle Size Analyzer for dry granular material

GRADEX 2000 particle size analyzer automates sieve analysis of dry granular material. Sample analysis and data recording are automatic. Samples can be analyzed individually, or up to seven samples can be run continuously in autofeed mode. Each sample of material is fed into a stack of test sieves and then sieved using a rotary/tapping action. The system accommodates a stack of six full-height or nine half-height standard round test sieves. Software is Windows-based for ease of setup and operation, data collection and transfer. ROTEX Inc., 1230 Knowlton St., Cincinnati, OH 45223.

Write In 255 - Or Reply Online

Lab Centered LIMS increases productivity

Nautilus 2000 includes automated validation tests that greatly reduce the validation effort in regulated laboratories. Standard Automated Installation Qualification Kit validates the installation and runs automated tests against the software. An optional kit includes automated tests with code; document of the extractred text and comments from the code; traceability matrix linking the tests to the functional descriptions; user guide; and run time libraries and files from the test automation tool. Program has been made Chemistry Aware through incorporation of the Accord ActiveX Chemistry control from Synopsys. For each chemical registered with the program, system can display chemical structure and perform chemical calculations. Thermo LabSystems Inc., 100 Cummings Center, Ste. 407J, Beverly, MA 01915.

Write In 260 - Or Reply Online

High Temperature Furnace benchtop model

Vulcan 3-400 HTA benchtop furnace provides a rapid, 40 C per minute ramp rote up to a maximum temperature of 1225 C. Higher temperature expands applications to include an increased range of metals. Integral Venturi drive air exchange increases exhaust rate of combustion gases, making the unit ideal for ashing samples for material analysis. Chamber size is 550 cubic inches and standard, multi-stage PID controller offers 9 separate programmable cycles for precise time/temperature control and one additional constant-temperature program. Furnace features a high performance quartz hybrid muffle, quartz shielded heating elements, and a specially designed thermocouple for reliable high temperature performance. NEYTECH, 65 W. Dudley Town Rd., Bloomfield, CT 06002.

Write In 261 - Or Reply Online

Zero Air Generators operational status display

Zero Air Generators are available in four models to produce up to 30 1pm of hydrocarbon-free air from an existing compressed air supply. New features include increased zero air flow rates of up to 20%, upgraded high tech design, continuous visual operational status display and wall mounting brackets. These generators allow chromatographers to supply, control, and automate their gas supplies for GCFIDs. Generators produce lower, more stable baselines than cylinders, significantly enhancing the sensitivity of analysis. They reduce the total hydrocarbon content to less than 0.05 ppm, measured as methane. Whatman, Inc., 100 Ames Pond Drive, Tewksbury, MA 01876.

Write In 262 - Or Reply Online

Benchtop Freeze Dryer 2-liter condenser

The Benchtop 2K Freeze Dryer offers a unique, low-cost solution to the sample processing needs of the pharmaceutical or life science researcher. This model features freezing capabilities to -50 C. The freeze dryer has a robust, 2-liter condenser system and a smooth-walled stainless steel condenser that achieves temperatures to - 55 C. It also provides an easy, hot-water defrost. VirTis Company, 815 Rte. 208, Gardiner, NY 12525.

Write In 263 - Or Reply Online

Ion Reference Materials for ion chromatography

Double the number of ion chromatography reference materials is now available from the company. The product line includes anion and cation single-element IC standards. Multi-element ion standards are also available and manufactured with the same high purity materials as the single-element standards. High level quality control documentation is provided with every standard. SPEX CertiPrep, Inc., 203 Norcross Ave., Metuchen, NJ 08840.

Write In 264 - Or Reply Online

Data Logger Line NIST traceable

Expanded Pro Series line of Data Loggers has a delayed start capability, storage of 32,512 sample points, and five-year battery life. They are compatible with MP100 multipoint monitor for remote monitoring of multiple instruments from one PC Four models include: TP 120 for temperature and humidity, SP 100 for single channel temperature, SP 120 for dual channel temperature with remote probe, and ES 120 for universal input. Dickson Co., 930 S. Westwood Ave., Addison, IL 60101.

Write In 312 - Or Reply Online

Small Circulator refrigerated & heating Model F30-C, a small sized refrigerated and heating circulator, offers full-range cooling and heating from - 26 C to 200 C. Compact model is 10" wide x 21" long x 15 1/2" high. Digital temperature setting and readout, external temperature controls via Pt100 remote sensor, digital interface, and many safety and early warning functions are standard. A strong pressure/suction pump handles temperature applications of the most demanding requirements and smallest tubing-diameters. JULABO, 754 Roble Rd., Allentown, PA 18103.

Write In 313 - Or Reply Online

Spectroradiometer UV/Vis/IR

IL2000 SpectroCube Spectroradiometer features double pass single grating optics which provide a scatter figure of 1 x [10.sup.-6] and dispersion of 4 nm/mm. Operating from 250 to 1100 nm and autoranging over 8 decades from 200 pW/[cm.sup.2]/nm @500 nm to 40 mW/[cm.sup.2] @ 500 nm with an f/4 aperture ratio and [+ or -] 0.5 nm wavelength accuracy, it can be controlled remotely via phone or serial port. Fully automated, it is powered on/off under remote software control and has a mode for unattended field monitoring. International Light, Inc., 17 Graf Rd., Newburyport, MA 01950.

Write In 314 - Or Reply Online

Mass Flow Sensors stainless steel

Model 50-SD Flo-Sensors combine state-of-the-art electronics, compact mechanical design and mass production tooling concepts. Meters combine features of sensors with a rotatably adjustable 3 1/2 digit LCD meter to view flow rate in engineering units such as ml/min or liters/min. Model incorporates thermal gas flow sensing technique combined with sophisticated electronic circuitry to provide a 0 to 5 VDC output signal. Flo-sensors cover flow ranges from 0-20 ml/min to 0-5 liters/min with accuracies of up to [+ or -] 1.5% full scale. McMillan Co., P.O. Box 1340, Georgetown, TX 78627.

Write In 315 - Or Reply Online

Dead Weight Testers pressure calibration

Whether pneumatic or hydraulic, 9000 series of Dead Weight Testers offers a high quality, cost-effective precision calibration source for many applications. Stainless-steel, non-magnetic weights are simple to use. Models available include pneumatic testers for pressures to 30,000 psi, comparison pump for quick checks against a test gauge reference, a convenient portable tester for pressures to 5000 psi, and an isolating diaphragm for oxygen clean applications. All dead weight testers are supplied with a certificate traceable to NIST. TTI, Inc., 8 LeRoy Rd., Williston, VT 05495.

Write In 316 - Or Reply Online

ORP Calibration Kit for electrodes

ORP Calibration Kit easily verifies the operational status of ORP electrodes. Each kit contains one pint of pH 7 buffer, one pint of pH 4 buffer, 20 grams of quinhydrone, 3 measuring cups and 75 wood applicators; enough material for 30 two-point calibrations. When made, solutions will generate 90 mV and 260 mV. A properly operating electrode will reproduce these values within 10%. If an electrode does not match these reference values, it requires maintenance or replacement. Sensorex, 11751 Markon Dr., Garden Grove, CA 92841.

Write In 317 - Or Reply Online

Circulator Line heating and cooling

Designed specifically for external systems, Huber Unistats provide highly efficient heating and cooling from -120 C to 300 C and cooling capacities up to 16 kW. With fully enclosed circulation systems designed for -40 C, -80 C or -120 C operation, these circulators eliminate problems associated with open bath systems, such as oil vapors, oxidation, spillage and moisture absorption. Standard features include programmable controller, digital and analog interface, stainless steel construction and compatibility with most thermal fluids. CARON Products & Services, P.O. Box 715, Marietta, OH 45750.

Write In 318 - Or Reply Online

Fume Extractor articulating arm

Miniarm FX is a jointed, articulating fume extractor arm, which can be mounted on the wall, ceiling, or directly to the workbench. Its main sections are constructed of aluminum, while the joints are comprised of polypropylene plastic, to add durability to the ann. The large, knurled ball bearing adjusted joints are easily adjusted with one hand. Five different hood designs and several fume cabinets allow this arm to handle most applications for smoke, dust, chemicals, solvents and fumes. Available in 2" and 3" diameters, they are offered in lengths from 1.8 to 4.74 feet long. Nederman, Inc., 39115 Warren Rd., Westland, MI 48185.

Write In 319 - Or Reply Online

Freezer Storage Boxes unbreakable/autoclavable

Economical line of twenty new freezer storage boxes is designed for microcentrifuge tubes and cryogenic vials. They are constructed of durable, unbreakable polypropylene, making them autoclavable and ideal for freezer storage. Some of the boxes have a hinged lid while others have a telescoping lid, allowing tubes of various lengths to be stored in them. The lid has a frosted area for marking and is translucent, allow for visibility of the tube caps. The boxes are supplied in a variety of sizes including 100 x 2 ml and 10 x 50 ml. Denville Scientific Inc., P.O. Box 4588, Metuchen, NJ 08840.

Write In 320 - Or Reply Online

Benchtop Desiccator storage system

SmartDesiccator Benchtop Storage System maximizes yields of sensitive materials by automatically maintaining a user-determined humidity set point. A quick-response feedback system continuously monitors RH level of the cabinet and activates a purge of dry nitrogen only when it is needed. A miniaturized LED display and sensor module occupies about 4 cubic inches inside the cabinet. Units include humidity control module, sensor, adjustable shelving and a safety bleed valve. They are available in acrylic or static-dissipative PVC, which helps control static charges and the particles they attract. Terra Universal, Inc., 700 N. Harbor Blvd., Anaheim, CA 92805.

Write In 321 - Or Reply Online

Environmental Chamber reach-in model

Model 3960 Reach-In Incubator/Environmental Chamber is 29 cubic foot model that provides a maximum of 140.4 square feet of usable space and is ideal for elevated temperature stability studies and shelf life testing. Microprocessor control/monitoring system with large, digital LED readout displays the actual temperature. Features include alarm contacts for remote monitoring of chamber conditions; heated glass door that optimizes temperature uniformity; two through-wall access ports; and an audible/visual alarm that warns of undertemperature or overtemperature conditions. Forma Scientific, Inc., P.O. Box 649, Marietta, OH 45750.

Write In 322 - Or Reply Online

Window Creator for CE columns

The Window Maker is specially designed for controlled stripping of polyamide to create detection windows in protectively clad, fused silica capillaries. It creates a reproducible 2 mm window area on both coated and uncoated capillaries, but is not recommended for use with polyacrylamide or CE-100SA, sulfonic acid coated capillaries. By creating only a 2 mm window, column maintains its strength while providing an adequate area for detector line-up. Unit uses a program switch so that a controlled, reproducible window is created from capillary to capillary, analysis to analysis. MicroSolv Technology Corp., 101 Brighton Ave., Long Branch, NJ 07740.

Write In 323 - Or Reply Online
COPYRIGHT 2000 Advantage Business Media
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2000 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:includes multiple products
Publication:Laboratory Equipment
Article Type:Product Announcement
Geographic Code:1USA
Date:Jun 1, 2000
Words:7914
Previous Article:New Literature.
Next Article:Editor's Choice.
Topics:

Terms of use | Privacy policy | Copyright © 2021 Farlex, Inc. | Feedback | For webmasters |