Improvement of the electrochemical determination of antioxidant using cationic micellar environment/Determinacao eletroquimica de antioxidante em meio micelar cationico.

Introduction

Ascorbic acid (AA) ([gamma]-lactone) is a water-soluble compound cited as antiscorbutic and antioxidant playing a key role in the immune response. This dietary component is well-known as an effective chain-breaking antioxidant employed as additive in emulsions to prevent lipid oxidation in pharmaceutical preparations and food. Thus, the oxidation of this compound to L-dehydroascorbic acid has received a great attention because of the important role that the redox chemistry of AA plays in human nutrition. The acid character and reduction action are attributed to its enodiol group (-COH = COH-) in the structure (LIU; ANZAI, 2004).

Considering the therapeutic purposes, nutritional assessment and important industrial application of AA, its determination in a selective and simple way has been a subject of constant interest. Among the analytical procedures to quantify AA, electrochemical approaches seem to have the greatest versatility (ARYA et al., 2000). However using bare electrode for instance is difficult because its fouling by oxidation and formed interfering products (ZEN et al., 2003). Strategies to eliminate interferences include covalent attachment of moieties with antifouling properties or ultrasonication (BANKS; COMPTON, 2003). Electrochemical treatment of working electrodes as glassy carbon electrode by potential cycling or prenodization has also been used to minimize adsorption effects in electrochemical determination of organic compounds (DOWNARD; RODDICK, 1994).

Recently has been shown the anionic surfactant sodium dodecyl sulfate (SDS) is effective in suppressing or eliminating adsorption interferences from proteins and phospholipids in the voltammetric determination of several bioorganic compounds. The anti-fouling effect of the SDS is attributed to its property of formation soluble aggregates with surface-active compounds (HOYER; JENSEN, 2005). It is known that surfactant behavior in solution involving aggregation or adsorption and organization on the electrode surface and it influences the electrode processes and the rate of electron transfer (VITTAL et al., 2006). In addition it has been reported that the antioxidant activity of AA was enhanced in micelles systems in some study of the anodic oxidation of AA and its lipophilic derivates in the presence of micelles (JAISWAL et al., 2001). The effect of micelles on chemical reaction has been drawing interest of many researchers, since chemical reactivity, equilibrium and stereochemistry of the reactants are significantly affected by micelles. Micellar catalysts of reactions are important due to their industrial applications pertinence to biological processes and analytical chemistry and also because of the parallel behavior of biological macro-molecules and enzymes. Micellar catalysis of reaction in aqueous solution is generally explained in terms of distribution of reactants between water and micelles with reactions occurring in both media (PENG; GAO, 2006).

Therefore studies in this direction can contribute to a better understanding of the role of surfactant in the improvement of analytical determination of biologically relevant compounds as AA.

This work describes a fast and simple method to determination of AA using a glassy carbon electrode without modification in the presence of cationic CPC micellar system. The surfactant works as masking agent and influences positively the electrochemical oxidation of AA. As a result is observed an improvement in the selectivity and sensitivity of the proposed method.

Material and methods

Reagents and Solution

Ascorbic acid (AA) and cetylpyridinium chloride (CPC) were used without further purification and were purchased from Sigma (St. Louis, USA). All aqueous solutions were prepared using ultrapure water ([rho] > 18 M[OMEGA] [cm.sup.-1]) from a Milli-Q System (Millipore, System). All other used chemicals were analytical grade reagent.

Apparatus and Equipments

The electrochemical measurements were carried out in phosphate buffer solution (PBS) 0.1 mol [L.sub.-1] using a conventional cell based on satured calomel electrode (SCE) as reference, platinum wire as auxiliary and glassy carbon electrode (GCE) as working electrode. The used CGE (A = 0.071 [cm.sup.2]) was polished with [Al.sub.2][O.sub.3] (0.5 pm), followed by rinsing with deionized water and then sonicated using alcohol and deionized water for 2 min.

A potentiostat from Eco Chemie Autolab[R] PGSTAT30 connected to a PC (software GPES 4.8) from Eco Chemie (The Netherlands) was employed in the measurements. Electrochemical experiments were performed at room temperature.

Results and discussion

Shows the effect of the CPC on the electrochemical oxidation of AA in PBS. Voltammetric curves of AA recorded in the absence of CPC (Figure 1b) showed an irreversible cyclic voltammogram with the AA oxidation peak around +0.23 V (vs SCE). Details of AA's electrochemical mechanism in bare CGE were reported in previous work (HU; KUWANA, 1986) and include an oxidative mechanism of multi steps (Figure 1).

[FIGURE 1 OMITTED]

The presence of CPC in solution promoted an increase in the electron transfer for the oxidation of AA as observed by the shift of the anodic peak potential toward less positive values followed by an increase in the peak current. Compared with bare GCE, the system in the presence CPC exhibits a 220 mV shifts of the oxidation potential of AA in the cathodic direction and a market enhancement of the current response.

The observed changes in the redox parameters of AA can be attributed to a surface effect. It is well established that surfactants can be absorbed on solid surfaces to form surfactants films (ROY et al., 2003; SZYMULA; MICHALEK, 2003). This behavior can be explained considering that AA in the studied media (pH 7.0) is monoprotonated and in micellar medium, before the CMC, this dissociated form is stabilized by an electrostatic interaction with CPC. A possible adsorption of the surfactant onto electrode surface may result in the formation of a positively charged hydrophilic film with the polar head group towards to the bulk of the solution, which interact with anionic AA. As a result a great effect is observed on the electron transfer rate.

Previous tests were performed to verify if occurs the formation of CPC film on the electrode and if this is the responsible by the observed electrochemical behavior. The film was prepared in a concentrated CPC solution before measuring. After immersing the electrode in a 0.1 mol [L.sup.-1] CPC solution during some minutes and after washed with water, the cyclic voltammogram recorded in presence of AA without CPC in the medium was similar to those obtained in the CPC presence, indicating the CPC film adsorbed on the electrode surface.

This effect on the behavior of AA was found to be dependent on the CPC concentration as shown in Figure 2. The oxidation potential of AA decreases with the increasing of the surfactant concentration. In the vicinity of CMC (critical micellar concentration) reaches a plateau corresponding to 0.020 V, whereas the peak current increases significantly up to the CMC and after this value it remains constant.

In the vicinity of CMC, ascorbate acid anion and the cationic surfactant coexist in solution in dynamic equilibrium, which starts the attachment of the anion radical to the micelle. At the CMC, in the present study, estimated by cyclic voltammetry occur the micellization process. The micellar assembly can be formed by the positively charged polar head group of surfactant locate in the interfacial region of the micelle and in its external core are the ascorbic acid molecules (ascorbate anions) bind by electrostatic interaction. After the CMC is observed a plateau in the plot of [E.sub.pa] and [I.sub.pa] against the surfactant concentration demonstrating a saturation of the adsorbed surfactant onto electrode surface. The excess of surfactant form micelles in the bulk solution and it no longer affect the electron-transfer process. Thus, it is possible to verify that CPC concentration around 1.0 mol [L.sup.-1] was enough to reach the CMC. Hence, this value was chosen for further experiments.

[FIGURE 2 OMITTED]

Optimized analytical parameters

In the electrochemical determination of organic molecules, the applied potential has a great influence over to the analytical response (SRIPRIYA et al. 2006). The dependence of potential on the electrode current is shown in Figure 3. It can be seen that the applied potential 0 V vs SCE is adequate to reach the maximum response for AA in CPC micellar medium. The presence of surfactant in the medium allows that redox direct reaction of AA at bare conventional electrodes as GC, occur in low potential. This eliminates the pronounced fouling effect associated with the oxidation of interference commonly present in samples, since this problem result in rather poor reproducibility to determine the vitamin. Thus, this potential was fixed for further analytical determination.

[FIGURE 3 OMITTED]

The amperometric determination of AA based on its electrochemical oxidation can be done at GC electrode operating at potential above + 500 mV vs ECS. This overpotential could be lowered substantially by the presence of surfactant in the medium as can be seen in Figure 4 that presents the changes in the steady-state oxidation current at 0 V vs SCE on the stepwise addition of increment of 50 [micro]mol [L.sup.-1] AA into PBS. The electrode response in the presence of surfactant is attained with much better sensitivity and more extensive linear response range in comparison those without surfactant in medium. The effect of surfactant on the performance of the GC electrode is attributed to the interference suppressor effect that allows the direct determination of AA (CONNORS et al., 1985; KAMAU et al., 1987) in this low potential with great sensitivity. This result is significant from the viewpoint of its practical application.

[FIGURE 4 OMITTED]

The GC electrode response for AA in the presence of 1.0 mol [L.sup.-1] CPC showed a linear range from 5.0 x [10.sup.-7] mol [L.sup.-1] up to 4.3 x [10.sup.-4] mol [L.sup.-1], expressed by the linear regression equation [I.sub.([mu]A)] = 0.05 ([+ or -] 0.01) + 0.017 ([+ or -] 0.001) [AA] [micro]mol [L.sup.-1], with a correlation coefficient of r = 0.9996 (n = 9). The detection limit of 2.0 x [10.sub.-7] mol [L.sup.-1] (S/N = 3). The present method showed sensitivity values lower than those obtained in recent reports for AA determination based on chemically modified electrode (CME). In these studies, the values obtained were linear range from 5 x [10.sup.-6] to 1 x [10.sup.-4] mol [L.sup.-1] and DL = 2.45 x [10.sup.-6] mol [L.sup.-1] (O'CONNELL et al., 2001), linear range from (2 4) x [10.sup.-6] mol [L.sup.-1] and DL = 6 x [10.sup.-7] mol [L.sup.-1] (FEI et al., 2004), linear range up to 6.2 x [10.sup.-3] mol [L.sup.-1] and DL = 3.1 x [10.sup.-7] mol [L.sup.-1] (MOTLAGH; NOROOZIFAR, 2003).

The repeatability in the measurements was evaluated through a series of 10 repetitive experiments carried out with 40 and 200 [micro]mol [L.sup.-1] ascorbic acid solutions. The relative standard deviations (R.S.D.) were 1.5 and 0.5%, respectively. These results suggest a good precision of the proposed method.

The response time considering the time to reach 100% of the signal was around 2 s. The response time was very better than the absence of CPC (around 20 s) at the same conditions of potential and concentration.

AA determination in samples

The fruit juice samples were diluted 100 times with PBS (pH 7.0) before measurements. Commercials pharmaceuticals were tested of fixed contents (300 mg [tablet.sup.-1]). A known amount of one tablet equivalent to 15 mg of AA was diluted in 10 mL electrolyte solution. The urine samples were tested without pretreatment. The AA content of the samples solution was detected using a conventional technique of standard addition method by extrapolating the linear curve. The accuracy of the results was verified by the recovery tests using samples in triplicate. In the samples were added certain amounts of AA in about the same concentration as found in the samples themselves. As shown for samples of orange juice and urine, recovery values were close to 100%. Samples of drug, despite simpler composition, showed major variations which can be attributed to an interference of matrix or other factor such as, errors in the experimental procedure as ineffective cleaning of electrode before measuring.

Considering the variety of interferents compounds coexisting in the tested samples the practical usefulness of the proposed method was demonstrated, which indicating that the proposed method can be applied very well in the analysis of the samples (Table 1).

Conclusion

The positively charged CPC adsorbed onto the electrode surface is responsible to control the electrode reactions of AA, shifting its oxidation potential toward less positive values. Thus, the oxidation of AA is facilitated at the positively charged surfactant CPC in solutions by electrostatic interaction between AA and CPC.

The electrode response to determine AA, in the presence of the CPC surfactant was very sensitive and good values in the recovery tests were found, contribute to the applicability of the proposed method for AA determination in complex samples.

Considering the analytical features of the method it is possible to conclude that it presents advantageous characteristics when compared to other similar methods mainly due to the simplicity, since used a GC electrode without modification.

DOI: 10.4025/actascitechnol.v32i4.6945

Acknowledgments

The authors thank Fapesp and CNPq for financial support.

References

ARYA, S. P.; MAHAJAN, M.; JAIN, P. Non-spectrophotometric methods for the determination of vitamin C. Analytical Chimica Acta, v. 417, n. 1, p. 1-14, 2000.

BANKS, C. E.; COMPTON, R. G. Ultrasonically enhanced voltammetric analysis and applications: an overview. Electroanalysis, v. 15, n. 5-6, p. 329-346, 2003.

CONNORS, T. F.; RUSLING, J. F.; OWLIA, A. Determination of standard potentials and electron-transfer rates for halobiphenyls from electrocatalytic data. Analytical Chemistry, v. 57, n. 1, p. 170-174, 1985.

DOWNARD, A. J.; RODDICK, A. D. Effect of electrochemical pretreatment of protein adsorption at glassy carbon electrodes. Electroanalysis, v. 6, n. 5-6, p. 409-414, 1994.

FEI, J. J.; LUO, L. M.; HU, S. S.; GAO, Z. Q. Amperometric determination of ascorbic acid at an electrodeposited redox polymer film modified gold electrode. Electroanalysis, v. 16, n. 4, p. 319-323, 2004.

HOYER, B.; JENSEN, N. Use of sodium dodecyl sulfate for suppression of electrode fouling in the voltammetric detection of biologically relevant compounds. Electroanalysis, v. 17, n. 22, p. 2037-2042, 2005.

HU, I. F.; KUWANA, T. Oxidative mechanism of ascorbic acid at glassy carbon electrode. Analytical Chemistry, v. 58, n. 14, p. 3235-3239, 1986.

JAISWAL, P.; IJERI, V. S.; SHRIVASTAVA, A. K. Voltammetric behavior of certain vitamins and their determination in surfactant media. Analytical Sciences, v. 17, p. 741-744, 2001.

KAMAU, G. N.; LEIPERT, T.; SHUKLA, S. S.; RUSLING, J. F. Electrochemistry of bipyridyl derivates of cobalt in solutions of anionic and cationic micelles. Journal of Electroanalytical Chemistry, v. 233, n. 1-2, p. 173-187, 1987.

LIU, A. H.; ANZAI, J. Ferrocene-containing polyelectrolyte multilayer film-covered electrodes: electrocatalytic determination of ascorbic acid and use of inner blocking layers to improve the upper detection limit of the electrodes. Analytical Bioanalytical Chemistry, v. 380, n. 1, p. 98-103, 2004.

MOTLAGH, M. K.; NOROOZIFAR, M. Electrocatalytic determination of L-ascorbic acid by modified glassy carbon with Ni[[([Me.sub.2](C[H.sub.3]CO).sub.2][14]tetraeno[N.sub.4]) Complex. Analytical Science, v. 19, n. 12, p. 1671-1674, 2003.

O'CONNELL, P. J.; GORMALLY, C.; PRAVDA, M.; GUILBAULT, G. G. Development of an amperometric L-ascorbic acid (Vitamin C) sensor based on electropolymerised aniline for pharmaceutical and food analysis. Analytical Chimica Acta, v. 431, n. 2, p. 239-247, 2001.

PENG, J.; GAO, Z. N. Influence of micelles on the electrochemical behaviors of catechol and hydroquinone and their simultaneous determination. Analytical and Bioanalytical Chemistry, v. 384, n. 7-8, p. 1525-1532, 2006.

ROY, P. R.; OKAJIMA, T.; OHSAKA, T. Simultaneous electroanalysis of dopamine and ascorbic acid using poly (N,N-dimethylaniline)-modified electrodes. Bioelectrochemistry, v. 59, n. 1-2, p. 11-19, 2003.

SRIPRIYA, R.; CHANDRASEKARAN, M.; NOEL, M. Voltammetric analysis of hydroquinone, ascorbic acid, nitrobenzene and benzyl chloride in aqueous, nonaqueous, micellar and microemulsion media. Colloid and Polymer Science, v. 285, n. 1, p. 39-48, 2006.

SZYMULA, M.; MICHALEK, J. N. Atmospheric and electrochemical oxidation of ascorbic acid in anionic, nonionic and cationic surfactant systems. Colloid and Polymer Science, v. 282, n. 12, p. 1142-1148, 2003.

VITTAL, R.; GOMATHI, H.; KIM, K. J. Beneficial role of surfactants in electrochemistry and in the modification of electrodes. Advances in Colloid and Interfaces Science, v. 119, n. 1, p. 55-68, 2006.

ZEN, J. M.; TSAI, D. M.; KUMAR, A. S. Flow injection analysis of ascorbic acid in real samples using a highly stable chemically modified screen-printed electrode. Electroanalysis, v. 15, n. 14, p. 1171-1175, 2003.

Received on 28 April, 2009.

Accepted on 29 September, 2009.

License information: This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Lucilene Dornelles Mello (1) *, Alaecio Pinheiro dos Reis (2) and Lauro Tatsuo Kubota (2)

(1) Universidade Federal do Pampa, Campus Bage, 96400-970, Bage, Rio Grande do Sul, Brazil. (2) Instituto de Quimica, Universidade Estadual de Campinas, Campinas, Sao Paulo, Brazil. * Author for correspondence: E-mail: lucilenemartins@unipampa.edu.br
Table 1. Determination of AA by proposed method.

Sample                          [AA] added

Human urine 1           80.0 [micro]mol [L.sup.-1]
Human urine 2           80.0 [micro]mol [L.sup.-1]
Human urine 3           80.0 [micro]mol [L.sup.-1]
Vitamin C tablet 1 **       6.0 mg [L.sup.-1]
Vitamin C tablet 2 **       6.0 mg [L.sup.-1]
Orange juice 1 ***          6.0 mg [L.sup.-1]
Orange juice 2 ***          6.0 mg [L.sup.-1]

Sample                               [AA] found *

Human urine 1           82.0 [+ or -] 2.0 [micro]mol [L.sup.-1]
Human urine 2           79.2 [+ or -] 1.0 [micro]mol [L.sup.-1]
Human urine 3           80.4 [+ or -] 1.0 [micro]mol [L.sup.-1]
Vitamin C tablet 1 **       6.1 [+ or -] 1.3 mg [L.sup.-1]
Vitamin C tablet 2 **       5.9 [+ or -] 1.0 mg [L.sup.-1]
Orange juice 1 ***          6.0 [+ or -] 0.2 mg [L.sup.-1]
Orange juice 2 ***          6.1 [+ or -] 0.2 mg [L.sup.-1]

Sample                  Recovery (%)

Human urine 1              103.0
Human urine 2               99.0
Human urine 3              102.0
Vitamin C tablet 1 **      100.2
Vitamin C tablet 2 **       98.3
Orange juice 1 ***         100.3
Orange juice 2 ***         101.0

* Standard deviation for three replicates;
** label value = 300 mg AA; *** mg AA calculated
by the method proposed = 485.2 [+ or -] 10 mg [L.sup.-1].
COPYRIGHT 2010 Universidade Estadual de Maringa
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2010 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Author:Mello, Lucilene Dornelles; dos Reis, Alaecio Pinheiro; Kubota, Lauro Tatsuo
Publication:Acta Scientiarum. Technology (UEM)
Date:Oct 1, 2010
Words:3091
Previous Article:Frying quality of potato, with regard to reducing sugar and nonreducing sugar, during storage at room temperature/Qualidade de batata para fritura,...
Next Article:Physicochemical parameters and quantification of cis-trans fatty acid in soybean oil and cassava french fries during discontinued frying/Parametros...
Topics:

Terms of use | Privacy policy | Copyright © 2019 Farlex, Inc. | Feedback | For webmasters