IMPACT STRENGTH OF ACRYLIC RESINS AFTER STORAGE IN DENTURE CLEANSERS.

Byline: FAIZA AMIN FAUZIA QADIR and SIDRA AKRAM

Abstract

The aim of the study was to evaluate the impact strength of heat cure acrylic resin after immersed in distilled water and denture cleansers.

Study was conducted at Dr. Ishrat-ul-ebad Khan Institute of Oral Health Sciences from January to April 2013. Seventy two (72) rectangular shaped13.0 mm in length and 4.0 mm thickness formed the study;Eighteen (18) specimens were measured at baseline (control group) of the study (0 day) 18 specimens were immersed in distilled water. Eighteen (18) specimens were placed in fittydent denture cleanser solution for 10 minutes and eighteen (18) specimens were placed in dentipur denture cleanser solution for 10 minutes. Specimens were polished stored in distilled water for 24 hours prior to experiment.After 60 days of immersion the specimens were tested for impact strength with impact strength tester. SPSS 16 was used for statistical analysis.Charpys impact strength was significantly decreased after storage in fittydent and dentipur denture cleanser tablets (pless than 0.05). No statistically significant difference were observed in impact strength when stored indistilled water (pgreater than 0.05).

These results suggest thatthe impact strength of denture base acrylic resin is influenced by denture cleansers used.

Key Words: Denture Base Resins Impact strength Denture Cleansers.

INTRODUCTION

Poly methyl methacrylate (PMMA) was first intro duced in 1937 by Walter Wright and is currently the material of choice for fabrication of removable partial denture and complete denture.1 PMMA is the most popular denture base material.2 Using the conventional (polymer/monomer) dough molding process virtually all dentures are constructed from PMMA based materials.3

Almost all these materials are processed by waterbath curing system.3 PMMA is being used in dentistry for various purposes like making denture bases artificial teeth provisional restorations surgical splints stents and orthodontic appliances.4 These polymers are cost effective and processed by comparatively simple tech niques. They are the material of choice for removable complete dental prostheses.5

It is of great importance to maintain the health of oral mucosa and hygiene of dentures in patients who use partial and fixed removable dentures.67 Denture cleansers prevent dentureinduced stomatitis halitosis remove discoloring caused by foods and drinks provide adequate denture plaque control and eliminate Candida albicans and Candida glabrataand other microorgan isms to dissolve calculus.810 The use of chemical agents may be the only means of denture hygiene in patients particularly those who are very old have Alzheimer's disease dementia or low motor capacity.1112 According to their chemical composition denture cleansers can be classified as: neutral peroxide enzymes alkaline peroxides alkaline hypocholorites disinfectants and acid.7 The most common commercial cleansers currently in use which require immersion techniques is alkaline peroxide.13

Gornitskyet al14 in their study evaluate perboratebased denture cleansers on the prosthesis and found out the excellent antimicrobial activity of these solution. McCabe et al15 confirmed that these 1 Assistant Professor Department of Science of Dental Materials solutions do not contain any abrasive particles and are favorable for hygiene of prosthesis. Fernandes et al16 reported that for removing Candida biofilms forms perborate solution was effective both in and polyamide and acrylic based denture base resins.

It is of clinical importance to determine whether denture cleansers alter the properties of acrylic resins. Some authors have concluded that the daily use of denture cleanser can affect the properties of denture acrylic resin.17 Denture base polymers are susceptible of color change18 if the cleaning solutions are not cor rectly used. The surface roughness is of great clinical relevance since it can affect biofilm formation and make it difficult to remove.19 A frequent problem that occurs with removable dentures is fracture which may be due to accidental dropping repeated masticatory forces and areas of stress concentrations around frenal notches.3

For this reason the impact strength (IS) of polymers used for the production of denture bases has been inves tigated.2021 The literature has shown that a 0.5% sodium hypochlorite solution is an effective denture cleanser for reducing microorganisms22 and it is also indicated for disinfecting denture liners and tissue conditioners preventing oral candidiasis.23 Conversely it has been suggested that alkaline peroxide tablets decrease the number of C. albicans colonyforming units on maxillary dentures24 and this cleaning solution is also considered to be an effective remover of bacterial plaque.25

Therefore the choice of appropriate methods for denture cleaning is clinically important when the ob jective of the procedures is not cause surface damage of the denture base and for daily use to prevent microbial adhesion.

METHODOLOGY

It was an in vitro experimental study conducted at Dr IshratulEbad Khan Institute of Oral Health Sciences and testing was performed at PCSIR Karachi Pakistan from January to April 2013. The material tested in the study was heatcure acrylic resin (Vertex rapid simplified Holland).

Seventy two rectangular specimens 13.0 mm in length and 4.0 mm thickness were prepared from stain less steel mould. These dimensions were according to the American Society for Testing and Material Standard D 256O6a. Material was polymerized according to manufacture instructions. After heat polymerization specimens were removed from the mold the flash was trimmed with a carbide bur and smoothened by the 200 girt sand papers with the help of sandpaper holder. The specimens were polished on a wet rag wheel with pumice slurry. After polishing all specimens were placed in distilled water at room temperature for 24 hours.

The samples were divided into four groups: Eighteen specimens were measured at baseline (0 day) without immersion in any solution. This was the control group of the study. Eighteen specimens were measured af ter 60 days of immersion in distilled water; eighteen specimens were measured after 60 days of immersion in fittydent denture cleanser tablets for 10 minutes (According to manufacturer recommendations) and eighteen specimens were measured after 60 days im mersion in Dentipur denture cleansers tablets for 10 minutes. (According to manufacturer recommendations) All specimens except the specimens in the control group (baseline) were placed in their respective containers and filled with distilled water. The specimens in the control group were measure at 0 day. After 24 hours the distilled water was discarded and the container was filled with their respective denture cleansers. The specimens were washed with distilled water and stored in distilled water.

This was repeated twice a day for total of 60 days. Specimens were placed in distilled water during storage. After 60 days impact strength was evaluated using charpys impact tester (Ceast Resil Itlay). Data analysis was performed by using Statistical Package for Social Sciences (SPSS) version16. The data was analyzed by using one way analysis of varianceone way (ANOVA) for a quantitative dependent variable by a single factor (independent) variable. To identify which of the mean differed significantly Tuckey's HSD (Honestly significant difference) was used at 0.05 sig nificance level.

RESULTS

The mean and standard deviation of impact strength test data are shown in Table 2. The fittydent denture cleanser solution showed highest reduction in the impact strength as compared to baseline (0 day). This was followed by dentipur denture cleanser solution in which specimens were immersed for 60 days twice a day simulating 120 cycles. The specimens immersed in distilled water showed lowest reduction in the impact strength in comparison with control group. One way analysis of variance (ANOVA) showed that statistically significant differences were found (pless than 0.001) when specimens were stored in baseline (control) and when specimens were stored in fittydent and dentipur solution (Table 3). It showed that the storage medium had an effect on the impact strength of heat cure acrylic res ins. Post hoc analysis for impact strength was done by Tukey HSD (Honesty Significant Difference) analysis to determine the difference among the groups.

After Post hoc analysis by Tukey HSD statistically insignificant values were observed when the specimens at baseline (0 day) were compared with the specimens immersed in distilled water. However statistically significant difference were observed when the specimens were immersed in distilled water and compare with the spec imens at baseline (0 day) The Post Hoc results showed statistically significant differences when specimens were stored in fittydent denture cleanser solution and dentipur denture cleanser solution.

DISCUSSION

To avoid the risk of crossinfection and to reduce microorganism's colonization different prostheses disin fection procedures have been studied and applied rou tinely. These procedures are washing and brushing with chemical agents microwave irradiation immersion in disinfectant solutions and use of effervescent cleansing tablets commonly used to clean dental prostheses.26

TABLE 1: MATERIAL USED IN THE STUDY

Material Type###Processing###Manufac-

###method###turer

Heat cure PMMA Heat cure polym VertexTM

acrylic###erization 100OC Rapid Sim

resins###for 20 min in the plified

###curing tank

TABLE 2: MEAN AND STANDARD DEVIATION OF CHARPY IMPACT STRENGTH AT BASE LINE (0 DAY) AND 60 DAYS IMMERSION IN CONTROL GROUP (DISTILLED WATER) AND EXPERIMENTAL GROUPS

Groups###Mean and Standard

###Deviation

Baseline (0 day)(control)###13.96 0.64b

Distilled water###12.611 0.50c

Fittydent denture cleanser###9.023 1.79a

tablets

Dentipur denture cleanser###9.680 1.60a

tablets

TABLE 3: RESULTS OF ONE WAY ANOVA FOR MEAN VALUES OF CHARPYS

N###Groups###Sum of###Df###Mean###Sig

###squares###square###value

72###Baseline###299.424###3###99.808###less than 0.001

###Control

###Fittydent

###Dentipur

IMPACT STRENGTH

To complement denture hygiene chemical cleansing is usually associated with mechanical cleansing as for good denture biofilm control brushing alone is not suf ficient.27 For patients with impaired manual dexterity chemical denture cleansing have become increasingly more popular due to ease of use. In the past chemical cleansing was thought to possibly damage denture base materials especially acrylic resins.28 This study was undertaken to evaluate any mechanical alterations in heatpolymerized denture base acrylic resins after soaking in different denture cleansers for 60 days twice a day simulating 120 cycles. It has been shown that by immersing in certain cleansing solutions the strength and the structure of denture base resins can be affect ed.29 If these chemicals affect negatively there would be greater incidence of fracture of these prosthesis. These fractures may occur either inside or outside the mouth.

If the denture dropped accidently and the denture has low impact strength fracture occur outside the mouth. Whereas inside the mouth heavy occlusal forces might cause denture base to fracture. Increased frequency of this type of failure due to use of denture cleanserscan be demonstrated byimpact strength testing. Ideally a complete denture resin must offer sufficient impact strength while extra orally high impact forces may occur as a result of dropping the prosthesis.30

The Charpy type test selected for the present study has been used by investigators to evaluate the IS of denture base acrylic resins.303132 The work hypothesis that denture cleansers would not have a significant effect on the IS of the denture base resin was rejected. The selection of denture cleanser depends on many factors and since these chemical solutions can cause substantial deterioration on the soft liners compatible materials should be considered to avoid or minimize any changes in the favorable physical or chemical prop erties.33 Future In vivo studies are recommended if the results of the current and other previous studies are clinically applicable.In a study conducted by Pisani MX et al33 authors found that the use of sodium perborate did not promote significant alterations in the evaluated properties.

The soaking trials followed the manufacture recom mendations. Significant differences in impact strength were found Pavarina AC21 conducted a study on the evaluation of strength of heat cure acrylic resins after immersing into disinfectants; they did not find any significant changes in the strength. The disinfectants used in the study were 4% chlorhexidine 1% sodium hypochlorite and 3.78% sodium perborate. These results might be due to the fact that the specimens were sub mitted to disinfection twice simulating when dentures come from the patient and before being returned to the patient. In a study conducted by Mansoor NS et al34 the authors immersed their specimens in denture cleansers and they did not find any significant difference in the impact strength of heat cure acrylic resins.

Similarly in a study conducted by Peracini A et al35 authors evaluated the strength of heat cure acrylic resins after immersed in denture cleansers solution and they found a marked decrease in the strength. The decrease in the impact strength of in the both the studies may be due to the reason that long term exposure to denture cleansers results in absorption of organic and inorganic components of denture cleansers by the polymer net work. Water molecules incorporated in between the polymer chains cause swelling of the meshwork and reduces the frictional forces in between the chains. As a result the chains of polymers move far a part from each other results in decrease strength of the material. The decrease in the impact strength of the specimens may be due to the fact that the heat cure acrylic resins used in the present study was polymerized through short curing cycle. This might lead to increase content of residual methylmethacrylate.

This result in decrease strength of the material as residual MMA adversely effects the properties of resins.

CONCLUSION

Within the limitations of this study following con clusion can be drawn: Ten minutes immersion twice a day for 60 days in Fittydent denture cleansers tablets and Dentipur denture cleansers tablets resulted in significant decrease in impact strength of the heat cure acrylic resin material.

REFERENCES

1 Eick JD. Biological properties of denture base resins. Dent Clin North Am: 1977; 21: 45960.

2 Abuzar MA Bellur S Duong N Kim BB Lu P Palfreyman N Surendran D Tran VT. Evaluating surface roughness of a polyamide denture base material in comparison with poly (methyl methacrylate).J Oral Sci. 2010; 52(4): 57781.

3 Craig RG. Restorative Dental Materials (ed) 11th. Saint Louis Mosby; 2006. Chapter No: 21 p 230.

4 Lee SY Lai YL Hsu TS. Influence of polymerization conditions on monomer elution and microhardness of autopolymerized polymethyl methacrylate resin. Eur J Oral Sci. 2002; 110(2): 17983.

5 Shay K. Denture Hygiene: A Review and Update. J Contemp Dent Pract. 2000; 1(2): 2841.

6 Peracini A Davi LR Ribeiro NG Souza RF Silva CHL Para nhos HFO. Effect of denture cleansers on physical properties of heatpolymerized acrylic resin. J Prosthodont Res 2010; 54: 7883.

7 Machado AL Breesing LC Vergani CE da Cruz Perez LE. Hardness and surface roughness of reline and denture base acrylic resins after repeated disinfection procedures. J Prosthet Dent 2009; 102: 11522.

8 Nikawa H Hamada T Yamamoto T. Denture plaquepast and recent concerns. J Dent 1998; 26: 299304.

9 Silva FG Kimpara ET Mancini MNG Balducci I Jorge AOC KogaHo CY. Effectiveness of six different disinfectants on removing five microbial species and effects on the topographic characteristics of acrylic resin. J Prosthodont 2008; 17: 62733.

10 Nalbant AD Kalkanci A Filiz B Kustimur S. Effectiveness of different cleaning agents against the colonization of candida spp and the in vitro detection of the adherence of these yeast cells to denture acrylic surfaces. Yonsei Med J 2008; 49: 64754.

11 Kulak-Ozkan Y Kazaoglu E Arikan A. Oral hygiene habits denture cleanliness presence of yeasts and stomatitis in elderly people. J Oral Rehabil 2002; 29: 30004.

12 Alam M Jagger R Vowles R Moran J. Comperative stain removal properties of four commercially available denture cleaning products: an in vitro study. Int J Dent Hygiene 2011; 9: 3742.

13 Renata CM Rodrigues G Blanca LT LACopyrighton Viviane MB Oliveira Altair A Del BelCury. Effect of a denture cleanser on weight surface roughness and tensile bond strength of two resilient denture liners. J Prosthet Dent 2003; 29: 494 98.

14 Gornitsky M Paradis I Landaverde G Malo AM Velly AM. A clinical and microbiological evaluation of denture cleansers for geriatric patients in longterm care institutions. J Can Dent Assoc 2002; 68: 3945.

15 McCabe JF Murray ID Kelly PJ. The efficacy of denture cleansers. Eur J Prosthodont Rest Dent 1995; 3: 203207.

16 Fernandes FSF PereiraCenci T Silva WJ Filho APR Straioto FG Del BelCury AA. Efficacy of denture cleansers on candida spp. biofilm formed on polyamide and polymethyl methacrylate resins. J Prosthet Dent 2010; 105: 5158.

17 McNeme SJ von Gonten AS and Woolsey GD. Effects of labo ratory disinfecting agents on color stability of denture acrylic resins. Journal of Prosthetic Dentistry. 1991; 66:13236.

18 Ma S Johnson GH and Gordon GE. Effects of chemical dis infectants on the surface characteristicsand color ofdenture resins. Journal of Prosthetic Dentistry. 1997; 77:197204.

19 Azevedo A Machado AL Vergani CE and Giampaolo ET. Effect of disinfectants on the hardness and roughness of reline acrylic resins. Journal of Prosthodontics. 2006; 15:23542.

20 Straioto FG RicominiFilho AP FernandesNeto AJ Del BelCury AA. Polytetrafluorethylene added to acrylic resins: mechanical properties. Braz Dent J 2010; 21: 5559.

21 Consani RL Azevedo DD Mesquita MF Mendes WB Saquy PC. Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins. Braz Dent J 2009; 20: 13237

22 SousaPorta S. R. LucenaFerreira S. C. Silva W. J. and Del BelCury A. A. "Evaluation of Sodium Hypochlorite as a Denture Cleanser: A Clinical Study" Gerodontology.2013.

23 Skupien J. A. Valentini F. Boscato N. and PereiraCenci T. "Prevention and Treatment of Candida Colonization on Denture Liners: A Systematic Review" Journal of Prosthetic Dentist ry.2013;110:(5) 35662

24 Uludamar A. Ozkan Y. K. Kadir T. and Ceyhan I.. "In Vivo Efficacy of Alkaline Peroxide Tablets and Mouthwashes on Candida Albicans in Patients with Denture Stomatitis" Journal of Applied Oral Sciences. 2010;18:(3)29196.

25 Rossato M. B. Unfer B. May L. G. and Braun K. O. "Analysis of the Effectiveness of Different Hygiene Procedures Used in Dental Prostheses" Oral Health and Preventive Dentistry. 2011;9:(3) 22127

26 Buergers R.; Rosentritt M.; SchneiderBrachert W.; BehrM.; Handel G. and Hahnel S. Efficacy of denture disinfection methods in controlling Candida albicans colonization in vitro. ActaOdon tol. Scand. 2008;66(3):17480

27 Mima EG Pavarina AC Neppelenbroek KH Vergani CE Spo lidorio DM Machado ALEffect of different exposure times on microwave irradiation on the disinfection of a hard chairside reline resin. J Prosthodont. 2008; 17(4):31217.

28 Jin C Nikawa H Makihira S Hamada T Furukawa M Murata H. Changes in surface roughness and colour stability of soft denture lining materials caused by denture cleansers. J Oral Rehab. 2003; 30(2):12530.

29 Pavan S ArioliFilho JN Dos Santos PH MolloFde A Jr. Effect of microwave treatments on dimensional accuracy of maxillary acrylic resin denture base. Braz Dent J. 2005; 16(2):119230

30 Dogan OM Bolayir G Keskin S Dogan A Bek B Boztug A. The effect of esthetic fibers on impact resistance of a conventional heatcured denture base resin. Dent Mat J 2007;26:23239.

31 Straioto FG RicominiFilho AP FernandesNeto AJ Del BelCury AA. Polytetrafluorethylene added to acrylic resins: mechanical properties. Braz Dent J 2010;21:5559.

32 Da Cruz Perez LE Machado AL Canevarolo SV Vergani CE Giampaolo ET Pavarina AC. Effect of reline material and denture base surface treatment on the impact strength of a denture base acrylic resin. Gerodontology 2010; 27: 6269.

33 Pisani MX SilvaLovato CH MalheirosSegundo Ade L Mace do AP Paranhos HF.Bond strength and degree of infiltration between acrylic resin denture liner after immersion in effer vescentdenture cleanser. J Prosthodont. 2009 ;18(2):12329.

34 Mansoor NS Saleh DM AbdAlhameed SM. The Effect of Denture Cleanser Materials on Impact Strength of Heat Cure Acrylic Resin. MDJ. 2010;7(2):21419.

35 Peracini A Davi LR de QueirozRibeiro N de Souza RF Lovato da Silva CH de Freitas Oliveira Paranhos H.Effect of denture cleansers on physical properties of heatpolymerized acrylic resin.J Prosthodont Res. 2010;54(2):7883.
COPYRIGHT 2014 Asianet-Pakistan
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2014 Gale, Cengage Learning. All rights reserved.

 
Article Details
Printer friendly Cite/link Email Feedback
Publication:Pakistan Oral and Dental Journal
Article Type:Report
Geographic Code:9PAKI
Date:Dec 31, 2014
Words:3318
Previous Article:A SURVEY ON ENDODONTIC IRRIGANTS USED BY DENTISTS IN PAKISTAN.
Next Article:EVALUATION OF RECURRING ESTHETIC DENTAL PROPORTION IN NATURAL SMILE OF PAKISTANI SAMPLE.
Topics:

Terms of use | Privacy policy | Copyright © 2018 Farlex, Inc. | Feedback | For webmasters