Printer Friendly

Elevated Level of Troponin but Not N-Terminal Probrain Natriuretic Peptide Is Associated with Increased Risk of Sudden Cardiac Death in Hypertrophic Cardiomyopathy Calculated According to the ESC Guidelines 2014.

1. Introduction

The risk factors of sudden cardiac death (SCD) for hypertrophic cardiomyopathy (HCM) in the ESC Guidelines [1] included echocardiogram, electrocardiographic (ECG) Holter monitoring, and clinical variables. The calculator for sudden cardiac death risk [1] has not included any biomarker. Recently, Kehl et al. [2] reviewed the available data regarding the usefulness of natriuretic peptides and troponins in HCM. Concentrations of natriuretic peptides, and to a lesser extent of troponins, correlate with left ventricular thickness, symptom status, and left ventricular hemodynamics by Doppler measurements (left ventricular filling pressure, left ventricular outflow tract gradient).

Neither ischemic biomarker nor signs and symptoms of myocardial ischemia are included in the calculator [1]. However, ischemic response to stress revealed by echocardiographic methods becomes important prognostic player [3,4].

Currently used high-sensitivity troponin I (hs-TnI) is an super precise biomarker for the detection of myocardial ischemia. In previous HCM studies, measurements of hsTn were only at a resting (without stress in unnatural condition) echocardiography and not timely synchronized with maneuvers to provoke LVOTG by natural stimuli reflecting daily common physical activity for patients [5-8]. Moreover, measurements of hs-Tn were also not timely synchronized with the Holter monitoring. So far, we have used the following protocol: 24-hour cycle--8 a.m., echocardiography with LVOTG provocation by natural stimuli (orthostatic test and Valsalva test [1, 9-13]; the observation was divided into 2 periods: day phase physical activity with probable episodes of provocable LVOTG (unmeasurable) and night phase period as a potential time for rise of troponin, in which the level has been measured after night at 8 a.m. in the next day). Between echocardiography and biomarker sampling, 24-hour Holter electrocardiography (ECG) was recorded and then the measurement of hs-TnI (the biomarker level has a close temporal relationship with findings on Holter ECG). This protocol seems to be reasonable because hs-TnI levels may be a potential cause of life-threatening ventricular arrhythmias occurring during the previous 24 hours.

The aim of this study was to assess the relationship between biomarker concentrations (hs-TnI, NT-proBNP) and calculated 5-year percentage risk score of SCD in HCM.

2. Methods

Consecutive patients with HCM were recruited to the study. Informed consent was obtained from each participant. All patients fulfilled conventional diagnostic criteria for HCM. The criteria for diagnosis of HCM, according to the ESC Guidelines, were the presence of left ventricular (LV) wall thickness of at least 15 mm without any other cause that could lead to ventricular hypertrophy [1,13]. The exclusion criteria were as follows: sport activity more than recreational, prior myocardial infarction, current symptoms suggestive of coronary artery disease, concomitant neoplasm, infection, or renal failure. Subjects who had a history of alcohol septal ablation or septal myectomy were not included into the present study.

The final sample included 46 patients with HCM (mean [+ or -] SD age, 39 [+ or -] 7 years; 24 men and 22 women).

Patients on current pharmacotherapy were studied according to the abovementioned protocol. Patients have been asked to perform their common day physical activity and nocturnal resting. This protocol seems to be reasonable because hs-TnI levels may be related with labile, dynamic nature of LVOTG with fluctuating peaks in daytime (provoked LVOTG as a potential cause of myocardial ischemia).

2.1. First Model of Risk Calculation (Only the Current ECG Holter). For calculating the percentage value of HCM risk score SCD, we assessed the following parameters: episodes of nonsustained ventricular tachycardia (nsVT) in current Holter monitoring (defined as three or more consecutive ventricular beats > 120 beats per minute) and two-dimensional (2D) echocardiography with the assessment of the maximal left ventricular wall thickness in diastole (MWT), left atrial diameter (LAD), and maximal provocable left ventricular outflow tract (LVOT) gradient [1]. For the disease history, we check the following binary variables: syncope and family history of sudden death [1]. Finally, we include into the calculator the age of patients [1].

2.2. Second Model of Risk Calculation (All ECG Holter Current + Previous ECG Holter). Every patient had at least 3 times 24-hour ECG Holter recordings during life. One ECG Holter is defined as current (simultaneous) with biomarker sampling, and the remaining 2 or more recordings took place in past history. Presence/absence of NsVT was assessed by summing the data of all Holter (previous and current). The remaining parameters used in calculation were identical as in the first model.

The study protocol was approved by a local institutional review board (Komisja Bioetyki Jagiellonian University).

2.3. Statistical Analysis. Normally distributed continuous variables were presented as mean [+ or -] SD. Differences between two groups were assessed using independent t-test. Categorical variables were assessed using the Fisher exact test and expressed as numbers (percentages). A P value of less than 0.05 was considered significant.

3. Results

The baseline characteristics of HCM patients are displayed in Table 1.

Hs-TnI was detected in all HCM patients and patients with abnormal level > 19.5 ng/L were defined as positive troponin subgroup; nonelevated hs-TnI subgroup consisted of negative troponin subgroup. After NT-proBNP measurement, only 3 patients have a normal concentration < 125pg/mL; thus, subgroup division has been created by a median.

In comparison between 19 patients (hs-TnI positive) versus 27 patients (hs-TnI negative), the calculated 5-year percentage risk of SCD in HCM was significantly greater, both in the first and in the second models (Table 2). In the second comparison between higher NT-proBNP versus lower NT-proBNP subgroups, the calculated 5-year percentage risk of SCD in HCM was not significantly greater in the first model as well as in the second model (Table 2).

4. Discussion

In the current study, patients with HCM and positive hs-TnI test have a higher risk of SCD estimated according to SCD calculator recommended by the ESC Guidelines 2014 than patients with negative hs-TnI test. Level of NT-proBNP is not associated with the calculated 5-year risk of SCD (stratified by calculator).

4.1. Clinical Application of Biomarkers in HCM. In a recent review paper, authors ask the question: NT-proBNP versus troponin: is one better than the other [2]. Although both biomarkers correlate with indices of HCM disease progression, BNP may be a more sensitive indicator of left ventricular hypertrophy than troponin. It was documented that the wall thickness threshold was lower for BNP elevation than for TnI elevation [14]. Moreover, it has also stronger predictors of hemodynamic parameters and clinical symptoms than troponin. Although a correlation between elevated troponin and elevated BNP has been demonstrated [14,15], it is not a consistent finding [8, 14].

Before our study, a strategy for application of these biomarkers to risk stratification has not yet been investigated. These biomarkers may be most useful when risk markers of SCD indicate intermediate or indeterminate risk.

The impact of stress echocardiography in HCM is limited by lack of standardization and outcome data. ECS guidelines recommend stress echo solely for evaluation of LVOT [3]. However, large-scale registry data show that stress echocardiography positivity for ischemic criteria (such as new wall motion abnormalities and coronary flow velocity reserve) rather than inducible gradients predicts adverse outcome in HCM [4]. In a large study [3], mortality was predicted using criteria for detecting ischemia on stress echocardiography. The investigators proposed that stress echocardiography has a signficant prognostic role in patients with HCM, with ischemic endpoints showing a greater predictive accuracy than hemodynamic endpoints [3].

In a recent review by McCarthy et al. [16], the utility of hs-Tn assessment in arrhythmic disease is only at the initial stage of investigations, but it has been postulated as a valuable screening marker for patients with HCM at high risk of SCD.

Regular training exercise (e.g., fitness activity) has recently been recommended for selected patients with HCM [17]. Based on current observation on the association between tachycardia and elevated troponin level in patients with HCM [18] and phenomenon of troponin release by exercise [19], we suggest that any exercise stress test in HCM patients (performed either for training or diagnostic purposes) should be controlled by troponin level measurements before exercise and 6 and 12 hours after the exercise. Especially predisposed to high LVOT gradient are HCM women > 50 years of age, due to smaller LV cavity size [20]. This subgroup of HCM patients may be particularly at risk to develop high gradient at peak/post exercise period resulting into increased calculated risk in calculator.

Our study has several limitations. First, our study group may appear too small to definitely rule out association between NT-proBNP and SCD HCM risk score. Secondly, the current pharmacological treatment was maintained, and particularly, [beta]-blockers were not withdrawn. In our pilot study, we aimed to make the observation on the correlation between hs-TnI release and timely synchronized findings on ECG Holter and resting/stress echocardiography.

Our preliminary study showed that ^-blocker withdrawal might not be safe in troponin-positive subgroup of patients. In future studies, we will attempt to increase the dose and use only one type of a [beta]-blocker to decrease ischemia burden.

We decided to measure hs-TnI levels only once because our pilot study was conducted in an outpatient setting. The optimal protocol, that is, 48-hour profile of troponin measurement with the assessment of troponin with echocardiographic examination every 8 hours, and 48 hours Holter monitoring (recommended by the ESC Guidelines), would require the in-hospital setting for the study and would be more costly. Moreover, only an outpatient-based study provides an opportunity to assess the heart rate during common daily physical activity of patients. At first look, the study by Kubo et al. [5] seems similar to our study; however, we have found essential differences from our investigation in many important points.

(i) Kubo et al. (in pre-era of the ESC Guidelines from 2014, authors did not use calculator risk factors for SCD) defined their study as analysis of combined cardiovascular events (with SCD episode [the most fatal end point] only in 4 patients--such number seems to be too small for proper statistical analysis). Our study was not follow-up designed, but focused on relationship between biomarker levels and calculated 5-year percentage risk score only for SCD in HCM. SDC is the most fatal, but an easy preventable complication of HCM (by ICD).

(ii) Morphologic/prognostic differences are also important (in Kubo et al., patients had less predisposition for SCD: a benign apical variant 28% versus 0% in our group). The benign morphologic pattern in Kubo et al. paper seems to correspond to the low number of SCD.

(iii) In Kubo et al., LVOT gradient was assessed in binary analysis < 30mmHg or [greater than or equal to] 30mmHg and only in resting conditions. In contrast, we have assessed LVOTG more precisely as a continuous variable, measured both at rest and after provocation (the provocable LVOTG is absolutely needed to measure risk of SCD by ESC calculator).

(iv) Kubo et al. did not analyze nsVT in ECG-Holter (which is absolutely needed to measure the risk of SCD by calculator); moreover, nsVT assessment is needed also in the American Guideline from 2011 for risk stratification of SDC. Thus, in a paper by Kubo et al., the lack of ECG Holter analysis is a serious limitation.

(v) Kubo et al. did not describe the time period between blood sampling for biomarkers and measurement of echo parameters (nsVT in Holter was not studied). In our study, the time synchrony between echo/ Holter and hs-TnI measurement was defined.

(vi) Kubo et al. did not analyze NT-proBNP, but only hsTn. Our study provides more information about two important biomarker sampling simultaneously with echocardiographic and ECG Holter measurements.

5. Conclusions

Patients with HCM and positive hs-TnI test have higher risk of SCD estimated according to SCD calculator recommended by the ESC Guidelines 2014 than patients with negative hs-TnI test.

5.1. Clinical Perspective. These findings suggest that hs-Tn may be useful as an additional biomarker for better risk stratification in HCM. Additionally, we have postulated to monitor also the biomarkers of endothelial dysfunction (impaired endothelium-dependent vasodilatation) [21].

https://doi.org/10.1155/2017/9417908

Conflicts of Interest

The authors declare that there is no conflict of interest.

Authors' Contributions

Rafal Hladij contributed to the conception, contributed to acquisition and analysis, and gave final approval. Renata Rajtar-Salwa contributed to the conception and design; contributed to acquisition, analysis, and interpretation; critically revised the manuscript; and gave final approval. Pawel Petkow Dimitrow contributed to the conception and design; contributed to acquisition, analysis, and interpretation; drafted the manuscript; critically revised the manuscript; and gave final approval. Renata Rajtar-Salwa and Rafal Hladij contributed equally to this work.

Funding

The authors received a Jagiellonian University Grant.

References

[1] Authors/Task Force members, P. M. Elliott, A. Anastasakis et al., "2014 ESC guidelines on diagnosis and management of hypertrophic cardiomyopathy: the task force for the diagnosis and management of hypertrophic cardiomyopathy of the European Society of Cardiology (ESC)," European Heart Journal, vol. 35, no. 39, pp. 2733-2779, 2014.

[2] D. Kehl, A. Buttan, R. J. Siegel, and F. Rader, "Clinical utility of natriuretic peptides and troponins in hypertrophic cardiomyopathy," International Journal of Cardiology, vol. 218, no. 2, pp. 252-258, 2016.

[3] Q. Ciampi, I. Olivotto, C. Gardini et al., "Prognostic role of stress echocardiography in hypertrophic cardiomyopathy: The International Stress Echo Registry," International Journal of Cardiology, vol. 219, no. 3, pp. 331-338, 2016.

[4] E. Picano, Q. Ciampi, R. Citro et al., "Stress echo 2020: the international stress echo study in ischemic and non-ischemic heart disease," Cardiovascular Ultrasound, vol. 15, no. 1, p. 3, 2017.

[5] T. Kubo, H. Kitaoka, S. Yamanaka et al., "Significance of high-sensitivity cardiac troponin T in hypertrophic cardiomyopathy," Journal of the American College of Cardiology, vol. 62, no. 14, pp. 1252-1259, 2013.

[6] S. Hasler, R. Manka, M. Greutmann et al., "Elevated high-sensitivity troponin T levels are associated with adverse cardiac remodelling and myocardial fibrosis in hypertrophic cardiomyopathy," Swiss Medical Weekly, vol. 146, article w14285, 2016.

[7] T. Kawasaki, C. Sakai, K. Harimoto, M. Yamano, S. Miki, and T. Kamitani, "Usefulness of high-sensitivity cardiac troponin and brain natriuretic peptide as biomarkers of myocardial fibrosis in patients with hypertrophic cardiomyopathy," The American Journal of Cardiology, vol. 112, no. 6, pp. 867-872, 2013.

[8] V. Moreno, D. Hernandez-Romero, J. Vilchez et al., "Serum levels of high-sensitivity troponin T: a novel marker for cardiac remodeling in hypertrophic cardiomyopathy," Journal of Cardiac Failure, vol. 16, no. 8, pp. 950-956, 2010.

[9] P. P. Dimitrow, M. Bober, J. Michalowska, and D. Sorysz, "Left ventricular outflow tract gradient provoked by upright position or exercise in treated patients with hypertrophic cardiomyopathy without obstruction at rest," Echocardiography, vol. 26, no. 5, pp. 513-520, 2009.

[10] P. P. Dimitrow and T. O. Cheng, "Standing position alone or in combination with exercise as a stress test to provoke left ventricular outflow tract gradient in hypertrophic cardiomyopathy and other conditions," International Journal of Cardiology, vol. 143, no. 2, pp. 219-222, 2010.

[11] P. P. Dimitrow, C. Cotrim, and T. O. Cheng, "Need for a standardized protocol for stress echocardiography in provoking subaortic and valvular gradient in various cardiac conditions," Cardiovascular Ultrasound, vol. 12, no. 1, p. 26, 2014.

[12] P. P. Dimitrow and R. Rajtar-Salwa, "Obstructive form of hypertrophic cardiomyopathy-left ventricular outflow tract gradient: novel methods of provocation, monitoring of biomarkers, and recent advances in the treatment," BioMed Research International, vol. 2016, Article ID 1575130, 8 pages, 2016.

[13] V. M. Parato, V. Antoncecchi, F. Sozzi et al., "Echocardiographic diagnosis of the different phenotypes of hypertrophic cardiomyopathy," Cardiovascular Ultrasound, vol. 14, no. 1, p. 30, 2016.

[14] T. Kubo, H. Kitaoka, M. Okawa et al., "Serum cardiac troponin I is related to increased left ventricular wall thickness, left ventricular dysfunction, and male gender in hypertrophic cardiomyopathy," Clinical Cardiology, vol. 33, no. 2, pp. E1-E7, 2010.

[15] C. Zhang, R. Liu, J. Yuan et al., "Significance and determinants of cardiac troponin I in patients with obstructive hypertrophic cardiomyopathy," The American Journal of Cardiology, vol. 116, no. 11, pp. 1744-1751, 2015.

[16] C. P. McCarthy, O. Yousuf, and A. Alonso, "High-sensitivity troponin as a biomarker in heart rhythm disease," The American Journal of Cardiology, vol. 119, no. 9, pp. 1407-1413, 2017.

[17] S. Saberi, W. Wheeler, J. Bragg-Gresham et al., "Effect of moderate-intensity exercise training on peak oxygen consumption in patients with hypertrophic cardiomyopathy: a randomized clinical trial," JAMA, vol. 317, no. 13, pp. 1349-1357, 2017.

[18] R. Hladij, R. Rajtar-Salwa, and P. P. Dimitrow, "Associaton of elevated troponin levels with increased heart rate and higher frequency of nonsustained ventricular tachycardia in hypertrophic cardiomyopathy," Polish Archives of Internal Medicine, vol. 126, no. 6, pp. 445-447, 2017.

[19] G. A. Pop, E. Cramer, J. Timmermans, H. Bos, and F. W. Verheugt, "Troponin I release at rest and after exercise in patients with hypertrophic cardiomyopathy and the effect of betablockade," Archivos de Cardiologia de Mexico, vol. 76, no. 4, pp. 415-418, 2006.

[20] P. P. Dimitrow, D. Czarnecka, K. Kawecka-Jaszcz, and J. S. Dubiel, "The influence of age on gender-specific differences in the left ventricular cavity size and contractility in patients with hypertrophic cardiomyopathy," International Journal of Cardiology, vol. 88, no. 1, pp. 11-16, 2003.

[21] P. P. Dimitrow, A. Undaa, M. Bober, W. Tracz, and J. S. Dubiel, "Plasma biomarkers of endothelial dysfunction in patients with hypertrophic cardiomyopathy," Pharmacological Reports, vol. 59, no. 6, pp. 715-720, 2007.

Renata Rajtar-Salwa, Rafal Hladij, and Pawel Petkow Dimitrow

2nd Department of Cardiology, Jagiellonian University Medical College, Krakow, Poland

Correspondence should be addressed to Pawel Petkow Dimitrow; dimitrow@mp.pl

Received 19 July 2017; Revised 8 September 2017; Accepted 26 September 2017; Published 20 November 2017

Academic Editor: Agata M. Bielecka-Dabrowa
Table 1: Baseline characteristics of the patients.

NYHA class                                   2.3 [+ or -] 0.6
CCS class                                    1.5 [+ or -] 0.4
Syncope (n)                                         15
Sudden death in family history (n)                  15
NSVT in current Holter (n)                          11
Creatinine, [micro]g/L                      82.3 [+ or -] 11.6
Maximum LV thickness, mm                    22.5 [+ or -] 4.2
Resting LVOT gradient, [greater than                8
 or equal to] 30 mm Hg (n)
Provocable LVOT gradient, [greater than             17
 or equal to] 30 mm Hg (n)
Left atrial diameter, mm, mean (SD)         4.83 [+ or -] 0.81
Drugs with negative chronotropic
 properties (n)
  [beta]-Blocker                                    37
  Verapamil                                         5
  None                                              4

CCS: Canadian Cardiovascular Society; LVOT: left ventricular
outflow tract; LV: left ventricular; NSVT: nonsustained ventricular
tachycardia; NYHA: New York Heart Association.

Table 2: Comparison between subgroups of hs-TnI positive versus
negative and also between subgroup of lower versus higher NT-proBNT
concentration (NS: nonsignificant).

First model-
current Holter     Hs-TnI negative       Hs-TnI positive
                       n = 27                n = 19

5-year SCD       3.81 [+ or -] 3.23%   6.38 [+ or -] 4.17%   P < 0.05
risk in HCM        Lower NT-proBNP      Higher NT-proBNP
                       n = 23                n = 23

5-year SCD       4.14 [+ or -] 4.18%   5.18 [+ or -] 3.63%      NS
risk in HCM

Second model-
all Holter         Hs-TnI negative       Hs-TnI positive
                       n = 27                n = 19

5-year SCD       4.25 [+ or -] 4.20%   6.90 [+ or -] 3.99%   P < 0.05
risk in HCM
                   Lower NT-proBNP      Higher NT-proBNP
                       n = 23                n = 23
5-year SCD       4.40 [+ or -] 3.62%   6.29 [+ or -] 4.18%      NS
risk in HCM
COPYRIGHT 2017 Hindawi Limited
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2017 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Research Article
Author:Rajtar-Salwa, Renata; Hladij, Rafal; Dimitrow, Pawel Petkow
Publication:Disease Markers
Article Type:Report
Date:Jan 1, 2017
Words:3171
Previous Article:New Markers of Inflammation and Tubular Damage in Children with Chronic Kidney Disease.
Next Article:The Impact of tagSNPs in CXCL16 Gene on the Risk of Myocardial Infarction in a Chinese Han Population.
Topics:

Terms of use | Privacy policy | Copyright © 2021 Farlex, Inc. | Feedback | For webmasters |