ELECTROCOAGULATION FOR THE TREATMENT OF WASTEWATER FOR REUSE IN IRRIGATION AND PLANTATION.

Byline: Muhammad Saleem, Alaadin A. Bukhari and Muhammad Noman Akram

Abstract

Growing water scarcity in Pakistan is compelling people to use the treated wastewater at least for landscape irrigation and plantation to augment available water resources. In the present study, a laboratory scale electrocoagulation (EC) process was utilized to treat the raw wastewater in order to bring the quality up to the international wastewater reuse standards. Effect of various operating parameters such as operating time, current density and inter-electrode spacing was evaluated to achieve the maximum possible treatment efficiency. It was found that the application of 24.7 mA/cm2 current density with an inter-electrode spacing of 5 cm may provide 91.8%, 77.2% and 68.5% removal in turbidity, COD and TSS within 30 minutes of EC treatment. The quality of treated wastewater was compared with various international standards/guidelines for wastewater reuse.

It was found that the studied parameters such as BOD, COD, TDS, TSS, turbidity, NO3-N, NH3-N, chloride, Na+ 2+ 2+ , Ca , Mg , sulfate, total phosphorus, electrical conductivity Oil and Grease (0 & G) and total coliform (TC) were within allowable limits. Electrical conductivity, TDS and Sodium Adsorption Ratio (SAR) are mainly used for the determination of wastewater suitability for safe irrigation. Their values do not exceed the international wastewater reuse standards. The study shows that the raw wastewater generated at the study site after EC treatment is safe for landscape irrigation and plantation.

Keywords: Electrocoagulation, Wastewater, Removal efficiency, Operating parameters

INTRODUCTION

Water is essential to sustain life on the biosphere. However; with the increasing population and industrial growth, its resources are becoming limited and/or contaminated. Due to growing demand globally more than a billion people lack access to sufficient water of good quality. Studies reported that one third of the world's population will experience severe water scarcity within the next 20 years (CGIAR, 2002). Rapid urbanization and high population growth in major cities of Pakistan has led to a deterioration of living conditions. Problems are compounded as most of the fresh water resources are severely polluted with untreated industrial and municipal wastes (Malik, 2005).

Solution to Augment water Resources

Among other water management alternatives, the reuse of treated wastewater gained considerable attention (Saleem, 2009; Ruma and Sheikh, 2010). The treated wastewater has several advantages over other sources of water, it minimizes pollution, augments groundwater resources by artificial recharge and it is a good nutrient source for landscape and farm irrigation (Saleem et al., 2000). While wastewater reuse in agriculture has been taking place for centuries, in countries like Mexico, Vietnam and China (Shuval et al., 1986). It is now receiving renewed recognition as a potential water source under conditions of increased freshwater scarcity. In many Middle Eastern and Asian countries, the reuse of wastewater is now a common practice. Wastewater may be used in agricultural sector especially for landscape irrigation and plantation (Al Salem and Abouzaid, 2006).

Limitations of Wastewater Reuse

Wastewater carries a wide spectrum of pathogenic organisms, which pose risk to agricultural workers, crop handlers and consumers (Al-Malack et al., 2002; Saleem et al., 2000, 2003; Saleem, 2009). High levels of nitrogen in wastewater may result in nitrate pollution of groundwater resources. Accumulation of heavy metals in soils and its uptake by plants is another risk associated with wastewater irrigation (Saleem, 2009).

Water Scenario in the Study area

Coastal industries at Karachi such as Karachi Nuclear Power Complex (KNPC) have been facing the water shortage problem for many years. It is expected that with the commissioning of next power plant in the vicinity of KNPC, the problem will augment. Municipal water supply to the plant is intermittent and limited. Estimated average municipal water consumption is about 180 to 190 m3/d. The range of annual wastewater generated at KNPC is 165-175 m3/d. Monthly average value noted is 170+-5 m3/d and 120+-5 m3/d during summer and winter seasons respectively. Amount of municipal water being used for landscape irrigation and plantation at the plant is about 53+-5 M3 /d which is about 29 percentage of total municipal water being consumed per day (Personnel communication). The use of wastewater for landscape irrigation and plantation at KNPC could be a promising option to conserve municipal water so as to manage the shortage of water.

Present study is carried out first to characterize the wastewater quality generated at KNPC and then to treat it by electrocoagulation (EC) technology to bring the pollutants within the guidelines of international environmental protection agencies (Daneshvar et al., 2004; Vigneswaran and Sundaravadivel, 2004).

Electrocoagulation is an alternative technology for wastewater treatment in addition to its other conventional applications. The main advantages of electrocoagulation over other conventional techniques, such as chemical coagulation and adsorption, are "in situ" delivery of reactive agents, no generation of secondary pollution, and compact equipment. The earlier studies have reported the potential of electrocoagulation to treat a variety of industrial and domestic wastewater (Vlyssides et al., 2000; Kobya et al., 2003; Can and Kobya, 2006; Holt et al., 2006; Bensadok et al., 2008; Merzouk et al., 2009; Virkutyte et al., 2010).

Electrocoagulation Process

In the electrocoagulation process when electrical current flows between two electrodes, coagulant is generated in situ by electrolytic oxidation of the anode material. With an iron anode, Fe(OH)2 or Fe(OH)3 is formed at the anode. Reaction mechanism of iron electrode at the anode and cathode are reported by many authors (Mollah et al., 2004; Othman et al., 2006; Babu et al., 2007; Murthy and Raina, 2008):

(a) Mechanism 1

Anode: Fe (s) ----> Fe 2+ (aq) + 2 e-

Fe2 (aq) + 2 OW (aq) -----> Fe(OH)2 (s)

Cathode: 2 H20 (1) + 2 e ----> H2 (g) + 2 OW (aq)

Overall : Fe (s) + 2 H20 (1) ----> Fe(OH)2 (s) + H2 (g)

(b) Mechanism 2:

Anode: 4 Fe (s) ----> 4 Fe (aq) + 8 e-

4 Fe (aq)+ 10 H20 (0+02 (g) ----> 4Fe(OH)3(s)+8 H(aq)

Cathode: 8 H (aq) + 8 C-10. ----> 4 H2 (g)

Overall: 4 Fe (s) + 10 H20 (1) + 02 (g) ----> 4 Fe(OH)3 (s) + 4 H2 (g)

According to Lame and Vorobiev (2003), the generation of iron hydroxides Fe(OH)n is followed by an electrophoretic concentration of colloids (usually negatively charged) in the region close to the anode. The produced ferrous ions hydrolyze to form monomeric hydroxide ions and polymeric hydroxide complexes that depend on the pH of the solution. The polymeric hydroxides, which are highly charged cations, destabilize the negatively charged colloidal particles allowing their aggregation and formation of floes. It also, depends on the solubility of the metal hydroxide. When the amount of iron in water exceeds the solubility of the metal hydroxide, the amorphous metal hydroxide precipitates is formed, which causes sweep-floe coagulation (Benefield etal., 1982).

Electrocoagulation process is used in the present study to evaluate the effects of EC time, applied current density and inter-electrode spacing on the EC process efficiency for the removal of studied parameters. The treated wastewater is compared with the international guidelines for its reuse.

METHODOLOGY

Present study carried out at Karachi Institute of Power Engineering (KINPOE) at KNPC, Karachi. Wastewater generated from offices, washrooms, toilets, kitchen and other domestic activities are collected in a sewage tank within KINPOE boundary before discharging to the Arabian Sea. Samples were collected from sewage tank in sterilized 300 ml glass bottles. Separate clean bottles were used for sampling. Nitric acid was added to bring the pH of samples below 2 to minimize precipitation and adsorption on container walls (APHA, 2000). After collection, the samples were transferred immediately to the laboratories in iceboxes within 2 hours and were analyzed. Strictly sterilize conditions were maintained throughout collection and transportation of the samples. Analysis of raw wastewater samples was performed in triplicate for various physical, chemical and biological parameters (Table 1).

In the second part of study the collected raw samples were treated by electrocoagulation process for predetermined time intervals and were analyzed for various parameters (Table 2). Analysis was carried out at Chemical Monitoring Laboratory, K1NPOE and Environmental Engineering Laboratory at NED University of Engineering & Technology, Karachi. All the sampling and analysis procedures were adopted from Standard Methods for the Examination of Water and Wastewater (APHA, 2000). Details of methods and instruments utilized during analysis are presented in Table 1.

Experimental Setup

A laboratory scale electrochemical setup made up of circular cell, electrodes and other accessories were arranged (Fig. 1). Electrocoagulation cell having 20 cm and 50 cm of internal diameter and height respectively provide an effective volume of 5 liters. However, in each run, 3 liter of sample was used to treat by electrocoagulation process. Two electrodes of iron with surface area of 32 cm2 were used in undivided cell based on the study elsewhere (Saleem, 2010).

The separation between the anode and the cathode was kept at 3 cm following the method of Abuzaid and coworkers (1999) during all the runs except in the investigation of electrode spacing. The temperature was maintained between 25-30 degC. The solution in the reactor was stirred by a plate impeller at a rotating velocity of 100 rpm (Heidolph RZR-2101). Controlled direct current was supplied by a DC power supply (Hitachi Model-17858). The current was kept invariant in each test by a rheostat (Engfield-Middlesex, U.K.) and measured by an ammeter (ATAGO, Japan).

Experimental Procedure

After detailed characterization of raw wastewater, several EC batch experimental runs were performed in the laboratory. Initially wastewater was rigorously stirred for few minutes by stirrer for homogenization of sample. During the study of EC, time current density of 24.7 mA/cm2 was applied for various time periods (ranging from 5 minutes to 60 minutes). Treated wastewater samples were collected after settling at predetermined time intervals to see the effect of EC treatment time on removal efficiency of TSS, COD and turbidity.

In order to see the influence of current density, 0.03, 0.2, 0.4, 0.79 and 1.0 A currents were passed for a contact time of 30 minutes. The currents provided current densities of 0.94, 6.25, 12.5, 24.7 and 31.25 mAIcm2 respectively in these runs. After passing each current, the sample was allowed to settle for 30 minutes so that the floes and the coagulates that were formed during electrocoagulation may settle.

In each experimental run, after settling, about 100 ml supernatant sample was collected for laboratory analysis. Various parameters were analyzed in the laboratory namely; BOD, COD, TDS, TSS, turbidity, NO3-N, NH3N, chloride, Na, Ca 2+' Mg2, sulfate, total phosphorus, electrical conductivity and Oil and Grease (0 & G). Later, SAR was calculated from the values of Na' , Ca2+ , Mg2+ of the samples. In addition to indicator microorganism, total coliform (TC), concentration of important metals (such as Hg, Zn, Cd, Fe, Cr and Al) were also determined (Table 2).

RESULT AND DISCUSSION

Characteristics of Raw Wastewater

Characteristics of the raw wastewater used in the experiments are presented in Table 1. As observed, the average BOD, COD and TSS concentrations are at the medium strength side as compared to the characteristics of typical domestic wastewater (Metcalf & Eddy, 2003). The high value of TDS or electrical conductivity is advantageous to the EC treatment of wastewater since it will eliminate the need to add an electrolyte that is necessary to facilitate the passage of current in the wastewater solution. Also, the presence of chloride at relatively high concentrations helps in the production of chlorine as a result of the electrochemical process. Chlorine is an oxidizing agent that can participate in oxidizing soluble ferrous ions into insoluble ferric ions as discussed earlier (Larue and Vorobiev, 2003). Furthermore, low values of IC shows the quality of wastewater is favorable for reuse purpose. Value of O&G is also very low showing that this wastewater may be treated easily.

A comparison of raw wastewater (table 1) with typical municipal wastewater characteristics showed it to be of weak to medium strength (Metcalf & Eddy, 2003).

Later, EC experiments were performed and the effect of various operating parameters on the process efficiency was evaluated. Results obtained in each run are discussed below.

Effect of Operating Time

The effluent treated with iron electrode, appeared greenish first and then turned yellow and turbid. This green and yellow color may be resulted from Fe 2+ and Fe 3+ ions generated during EC process. Fe 2+ is the common ion generated in situ of electrolysis of iron electrode. It has relatively high solubility at acidic or neutral conditions and can be oxidized easily into Fe 3+ by dissolved oxygen in water (Benefield et al., 1982; Babu et al., 2007). The effect of time was studied at constant current density of 24.7 mA/cm2. Figure 2 illustrates the removal of TSS, COD and turbidity as a function of operating time, which shows that EC time has a significant effect on the pollutant removal. When the operating time increased from 10 to 30 minutes, the removal of TSS increased from 39.5% to 68.5% and COD from 49.6% to 77.2%. Similarly turbidity removal increased from 52.9% to 91.8%. In this process, EC involves two stages which are destabilization and aggregation.

The first stage is usually short, whereas the second stage is relatively long. Results show that maximum efficiency of EC process was obtained at a treatment time of 30 minutes and further increase in treatment time has insignificant improvement in the removal efficiency for the studied parameters.

Kobya et al. (2003) and Daneshvar et al. (2003) observed that pH significantly influences the treatment performance of the electrocoagulation process. Therefore, the effect of the operating time on the value of pH was noted. The initial pH of solution was kept constant at 6.5. According to Figure 3 the pH value increases as the operating time of EC process is increased and reached to 8.4. This is due to the OW ion accumulation in aqueous solution during the process. The increase of pH at acidic condition was attributed to hydrogen evolution at cathodes (Abuzaid et al., 1998). Generally, the pH of the medium changes during the process (Othman et al., 2006; Yildiz et al., 2008). However, the value of pH remained within the allowable limits (Table 2).

Effect of Applied Current Density

Effect of current density on the removal efficiency of EC process was investigated. Results are presented in figure 4. As expected, it appears that for a given time, the TSS removal efficiency increased significantly with the increase in current density. As the current density decreased, the time needed to achieve similar efficiencies increased. According to Chen and coworkers (2000) the treatment efficiency was mainly affected by charge loading. However, the cost of the process is required to determine by the consumption of sacrificial electrode and electrical energy. As the increase in current density augment the cost of treatment, one may use an optimum value of current density for efficient treatment and minimum cost. The result shows that the current density of 24.7 mA/cm2 is reasonable because above this value insignificant improvement in removal efficiency is observed.

Effect of Inter-electrode Spacing

Inter-electrode spacing is a vital parameter in EC process for the removal of pollutant from effluent. Increasing the electrodes spacing will reduce the capital cost of treatment but may reduce the treatment efficiency.

Hence, an optimization of this parameter is critical (Bukhari, 2008). Removal of TSS and turbidity at inter-electrode spacing of 3, 5, 7 and 8 cm was studied. In each EC run the treatment time was kept constant at 30 minutes. Variation of TSS and turbidity removal as a function of inter-electrode spacing is presented in Figure 5. The analysis reveals that the removal efficiency of EC process for TSS and turbidity increased as the inter-electrode spacing decreased from 8 cm to 5 cm. Maximum removal efficiency observed at an inter-electrode spacing of 5 cm. However, further reduction in inter electrode spacing does not increase the process efficiency.

The experimental states that a shorter gap would favor the minimization of the potential drop, which lead to a higher current density. However, after an optimum spacing surface charge double layer dominates and suppresses the removal efficiency (Mattenson et al., 1995). Furthermore, that the formation of scale on cathode surface may also passivate the electrode (Belmont et al., 1998, Virkutyte et al., 2010; Reyter et al., 2009, 2010). It concludes that for the studied operational conditions, an inter-electrode spacing of 5 cm is feasible for the removal of TSS and turbidity using EC process.

Comparison of Treated Wastewater Quality with Available Standards

After determining the optimum values of aforesaid operating parameters, the treated wastewater quality was compared with various international wastewater reuse quality standards (Table 2). Comparison allows to judge the effectiveness of EC process for the treatment of wastewater to be utilized for landscape irrigation and plantation at KNPC. The analysis shows that TDS, TSS and turbidity are within the allowable limits of various countries. However, TSS and turbidity slightly exceed the limits of Saudi Arabian standards, since these standards are relatively stringent compared to other countries. These standards are specific for unrestricted (uncooked eaten crops) irrigation.

The final pH value of treated wastewater is basic (8.2 +- 0.2) which is within the allowable limits. Similarly conductivity, 0 & G, COD, BOD, NH3-N, NO3-N, sulfate and chloride are below allowable limits. Value of total phosphate exceeds the Saudi Arabian standards. However, values are far below the standards of other countries. In case of metals, only the concentration of Zn (2.3 + 0.2 mg/1) exceeds the limits of USA (2.0 mg/l), Taiwan (2.0 mg/l), Kuwait (2.0 mg/l) and China (2.0 mg/l). Microbiologically important indicator the total coliform shows that after EC treatment their count became zero. This ensures that the treated wastewater microbiologically safe.

Electrical conductivity and TDS has great importance in irrigation business. Higher EC and TDS may damage the soil and become a potential irrigation problem. The conductivity and TDS values of studied wastewater are coming under 'Good' class (Class 2) of irrigation water (Table 3). Result shows that the quality of treated wastewater is safe for landscape irrigation and plantation. Furthermore, SAR is another important parameter which determines the extent to which sodium ion is adsorbed by the soil. If irrigation water with a high SAR is applied to a soil for years, the sodium can displace the calcium and magnesium in the soil. This will decrease the soil ability to form stable aggregates. This will also lead to a decrease in infiltration and permeability of the soil leading to problems with crop production (Dontsova, 2002). Therefore, SAR are calculated for the treated wastewater and compared with the allowable limits of Canadian Standards (Table 4).

This shows that the values of EC and SAR of the treated wastewater are within the safe range.

Table 1. Characteristics of raw wastewater and a comparison between raw wastewater at KNPC with typical untreated domestic wastewater

###Studied###Typical Concentration

Parameters###Instruments! Method Used###Raw###(Metcalf and Eddy, 2003)

###Wastewater###Low###Medium###High

###Strength###Strength###Strength

Total Solids (TS)###Gravimetric###734+-8###390###720###1230

Total Dissolved Solids (TDS)###Gravimetric###498+-5###270###500###860

Total Suspended Solids (TSS)###Gravimetric###236+-5###120###210###400

Biochemical Oxygen Demand (BOD5)###Low Temperature Incubation###170+-2###110###190###350

Total Organic Carbon (TOC)###Shimadzu, TOC-410###75+-0.8###80###140###260

Chemical Oxygen Demand (COD)###Closed Reflex, Titrimetric Method###420+-3###250###430###800

Conductivity###HACHI 51800-10###980+-5###--###--###--

Turbidity###HACH! 2 1 00###415+-5###--###--###--

Free ammonia###Titrimetric Method###24.2+-0.6###12###25###45

Nitrates###Spectrophotometer###3.7+-0.5###0###0###0

Phosphorus (total as P)###Stannous Chloride Method###9.1+-0.2###4###7###12

Chlroides###Titration###72+-1.2###30###50###90

Sulfate###Spectrophotometer###28.4+-2###20###30###50

Oil and Grease (0 and G)###Soxhlet Extraction Method###8.2+-1###50###90###100

Total Coliform (TC)###MPN Method/Multiple-Tube###410+-5###106_108###107_109###107_1010

###Fermentation Technique

pH###pH meter/Mi-iS 1/Italy###7.5+-1###--###--###--

A11 units are in mg/l, except pH, conductivity ((mho/cm), coliform MPN/lOOml, and turbidity (NTU)

Table 2. Comparison of studied treated wastewater quality with various wastewater reuse standards (Vigneswaran and Sundaravadivel, 2004)

Pararneters###KNPC###WHO###USA###China###Saudi Arabia###Jordan

TDS###450+- 10###1500###500-2000###1000-2000###-###1500

TSS###19+-0.8###150###50###150###10###50

Turbidity###1.2+-0.6###-###Less than 2###-###1###-

pH###8.2+-0.2###6-9###6-9###6.5-8.5###6-8.4###-

Conductivity###650+-10###-###-###-###-###-

Oil and Grease###2.4+-0.2###8.0###-###-###8.0###8.0

COD###84+-3###500###-###200###150###-

BOD###8.7+-1###200###Less than 10###80###10###50

NH3-N###21.4+-0.2###25###-###-###1.0###25

NO3-N###2.7+-0.1###45###-###-###10###-

Sulfate###12.3+-1###-###-###-###-###500

Tot Phosphate###15.7+-0.5###30###-###-###1.0###30

Chloride###64.2+-1###400###-###250###280###400

Total Coliform###0###1000###0###-###23###200

Hg###Less than 0.001###0.002###-###0.01###0.001###0.002

Zn###2.3+-0.2###5.0###2.0###2.0###4.0###5.0

Cd###Less than 0.01###0.01###0.05###0.05###0.01###0.01

Fe###3.8+-0.2###5.0###20###-###5.0###5.0

Cr###Less than 0.1###0.1###1.0###0.1###0.1###0.1

Al###4.2+0.2###5.0###20###-###5.0###5.0

Table 3. Permissible limits for interpretation of water quality for irrigation (Fipps, 2004)

Potential Irrigation###Present###Classes of Water

###Class 1.###Class 2.###Class 3.###Class 4.###Class 5.

Problem###Study###Excellent###Good###Permissible###Doubtful###Unsuitable

Electrical onductivity###650 +- 10###250###250-750###750-2,000###2,000-3,000###3,000

j.tmho/cm

TDS###450 +- 10###175###175-525###525-1,400###1,400-2,100###2,100

mg/i

Table 4. Comparison of SAR and EC values of studied wastewater with the irrigation water guidelines in Alberta, Canada (AEP, 2000)

Parameters###Present Study###Safe###Possibly Safe###Hazardous

EC(jmho/cm)###650+- 10###Less than 1000###1000-2500###Greater than 25000

SAR###3.6+- 0.2###Less than###4###4-9###Greater than 9

CONCLUSIONS

Raw wastewater generated at KNPC was characterized for possible reuse in landscape irrigation and plantation. Analysis of the wastewater shows that it is of weak to medium strength compared to the typical domestic wastewater (MetCalf & Eddy, 2003). However, raw wastewater is not suitable for direct. Since their various parameters (solids, turbidity, BOD, COD, metals and total Coliform) were above international standards. A laboratory scale EC process was utilized to treat the raw wastewater in order to bring the quality up to the required level. Effect of various parameters such as operating time, current density and inter-electrode spacing was evaluated. It was found that 91.8%, 77.2% and 68.5% removal in turbidity, COD and TSS were achieved within 30 minutes of EC treatment. Further increase in treatment time did not improve their removal efficiency. Change in pH value during EC treatment was also noted and maximum value of 8.4 was observed at the end of treatment which is within allowable limits.

Applied current density has significant effect on the removal efficiency of EC process. It was found that the current density of 24.7 mAicm2 has the highest removal efficiency for studied. Further increase in current density showed insignificant improvement in removal efficiency.

The effect of inter-electrode spacing on the removal of TSS and turbidity reveals that their removal efficiency increases as the inter-electrode spacing decreases from 8 cm to 5 cm. Maximum removal efficiency is observed at an inter-electrode spacing of 5 cm. However, further reduction in inter electrode spacing does not increase the process efficiency. This states that a shorter gap favors the minimization of the potential drop that leads to a higher current density. However, after an optimum spacing surface charge double layer dominates and suppresses the removal efficiency (Virkutyte et al., 2010; Reyter et al., 2010).

After EC treatment, the wastewater quality was compared with various international wastewater quality standards. It was found that the studied parameters were within the allowable limits except TSS and turbidity of Saudi Arabian standards. Saudi Arabian standards are relatively stringent these are specific for unrestricted (uncooked eaten crops) irrigation. Electrical conductivity, TDS and Sodium Absorption ration (SAR) are important to determine the suitability of wastewater for safe irrigation. Their values are within safe range. Finally, study shows that the raw wastewater generated at KNPC after EC treatment is safe for landscape irrigation and plantation. It can be stated that the study may help to conserve municipal water and alleviate the water shortage problem in the study area.

ACKNOWLEDGEMENT

Authors are thankful to Karachi Institute of Power Engineering, Karachi for providing support to complete this study.

REFERENCES

Abuzaid, N.S., Bukhari, A.A., Al-Hamouz, Z.M. 1998. Removal of bentonite causing turbidity by electrocoagulation. J. Environ. Sci. Health, Part A. 33(7): 1341-1358.

AEP (Alberta Environmental Protection), 2000. Guidelines for Municipal Wastewater Irrigation, Municipal Program Development Branch Environmental Sciences Division, Environmental Services, Report No. T-528, Alberta.

Al Salem, S.S. and Abouzaid, H. 2006. Wastewater Reuse for Agriculture: regional health perspective. Eastern Mediterranean Health J. 12(3-4): 446.

Al-Malack, M.H., Basha, K.I., and Saleem, M. 2002. Inactivation of indicator bacteria using ultraviolet radiation. In Proceedings of Conference on Wastewater Management and its Effects on the Environment in Hot and Arid Countries. Muscat, Sultanate of Oman.!: 1-10.

APHA (American Public Health Association), 2000. Standard Methods for the Examination of Water and Wastewater. American Public Health Association, Washington, DC.

Babu, R. R., Bhadrinarayana, N.S., Meera, K.M., Begum, S. and Anantharaman, N. 2007. Treatment of tannery wastewater by electrocoagulation, J. of the Univ. of Chem. Technol. and Meta. 42(2): 201-206.

Belmont, C., Ferrigno, R., Leclerc, 0. and Girault, H. H. 1998. Coplanar interdigitated band electrodes for electrosynthesis. Part 4: Application to sea water electrolysis. Electrochimica Acta. 44(4): 597-603.

Benefield, L.D., Judkins, J.F., Weand, B.L. 1982. Process Chemistry for Water and Wastewater Treatment. Prentice-Hall Inc., Publishers, Englewood Cliffs, NJ, 07632.

Bensadok, K., Benammar, S., Lapicque, F., Nezzal, G. 2008. Electrocoagulation of cutting oil emulsions using aluminium plate electrodes. J. Hazard. Mater. 152(1): 423-430.

Bukhari, A.A. 2008. Investigation of the electrocoagulation treatment process for the removal of total suspended solids and turbidity from municipal wastewater. Bioresour. Technol. 99(5): 914-921.

Can, O.T., Kobya, M., Demirbas, E., Bayramoglu, M. 2006. Treatment of the textile wastewater by combined electrocoagulation. Chemosphere. 62(2): 181-187.

CGIAR (Consultative Group on International Agricultural Research). 2002. One Third of World's Population will Experience Severe Water Scarcity by 2025, News, Accessed on September, 2010. http:Ilwww. futureharvest.org/news/03171999.shtrnl.

Chen, G.H., Chen, X.M., Yue, P.L., 2000. Electrocoagulation and electroflotation of restaurant wastewater. J. of Environ. Eng. 126 (9): 858-863.

Daneshvar, N., Salari, D., Khataee, A.R. 2003. Photocatalytic degradation of azo dye acid red 14 in water: investigation of the effect of operational parameters. J. Photocheni. Photobiol. A. Chemistry 157: 111-116.

Daneshvar, N, Sorkhabi, H.A., Kasiri, M B 2004. Decolorization of dye solution containing Acid Red 14 by electrocoagulation with a comparative investigation of different electrode connections. J. of Hazard. Mater. 112(1-2):55-62.

Dontsova, K.M. and Darrell, N.L. 2002. Clay dispersion, infiltration, and erosion as influenced by exchangeable Ca and Mg. Soil Sci. 167:184-193.

Fipps, G. 2004. Irrigation Water Quality Standards and Salinity Management. Texas A&M University, Cooperative Extension, Technical Bulletin B-1664. 2(1): 214-227.

Holt, P.; Barton, G.; Mitchel, C. 2006. Electrocoagulation as a wastewater treatment, The third Annual Australian Environmental Engineering Research Event. 1: 23-26.

Kobya, M., Can, O.T., Bayramoglu, M., 2003. Treatment of textile wastewater by electrocoagulation using iron and aluminum electrodes. J. of Hazard. Mater. 13100: 163178.

Larue, 0., and Vorobiev, E. 2003. Floc Size Estimation in Iron Induced Electrocoagulation and Coagulation using Sedimentation Data. Int. J. Miner. Proc. 71: 1-15.

Malik, A.H. 2005. Sustainable water resources management in Pakistan', Environmentally Sustainable Development. In Proceedings of COMSATS Institute of Information Technology Conference, 26-28 June, 2005, Abbottabad, Pakistan. 947-958.

Mattenson, M.J., Dobson, R.L., Glenn, R.W., Jr., Kukunoor, N.S., Waits III W.H., Clayfield, E.J. 1995. Electrocoagulation and separation of aqueous suspension of ultrafine particles. Colloids and Surfaces A: Physicochem. Eng. Aspects. 104: 101-109.

Merzouk, B., Gourich, B., Sekki, A., Madani, K., Vial, Ch., Barkaoui, M., 2009. Studies on the decolorization of textile dye wastewater by continuous electrocoagulation process. Chem. Eng. J. 149 (1-3): 207-214.

Metcalf and Eddy. 2003. Wastewater Engineering Treatment, Disposal and Reuse, Mc Graw-Hill Book Co, Singapore.

Mollah, M.Y.A., Morkovsky, P., Gomes, J.A.G., Kesmez, M., Parga, J., Cocke, D.L., 2004. Fundamentals, present and future perspectives of electrocoagulation. J. Hazard. Mater. Bi 14 (1-3): 199- 210.

Murthy, Z.V.P. and Raina, A. 2008. Treatment of Wastewater of Navy Blue-3G by Electrocoagulation. Int. J. Chem. React. Eng. 6: S2.

Othman, F., Sohaili J., Ni'am M.F. and Fauzia Z. 2006. Enhancing suspended solids remove from wastewater using Fe electrodes. Malaysian J. of Civil Eng. 18 (2): 139-148.

Reyter, D., Belanger, D. and Roue, L. 2009. Elaboration of Cu-Pd films by co-electrodeposition. Application to nitrate electroreduction. J. of Phy. Chem. 113: 290-297.

Reyter, D., Belanger, D. and Roue, L. 2010. Nitrate removal by a paired electrolysis on copper and Ti/Ir02 coupled electrodes - influence of the anode/cathode surface area ratio.Wat. Res. 44(6): 1918-1926..

Ruma, M.M. and Sheikh, A.U. 2010. Reuse of wastewater in urban farming and urban planning implications in Katsina metropolis, Nigeria. African J. Environ. Sci. Technol. 4(1):028-033.

Saleem, M. 2009. Wastewater reuse potential in Pakistan: Guidelines for environment and public health protection. Int. J. Environ. Eng. 1(3): 306-320.

Saleem, M. 2010. Nitrite removal from marine aquaculture wastewater using electrochemical process. The Nucleus 47(3): 227-232.

Saleem, M., Bukhari, A.A., and Al-Malack, M.H. 2000. Removal efficiencies of indicator micro-organisms in the Al-Khobar wastewater treatment plant. Environ. Eng. Sci. 17(4): 227-232.

Saleem, M., Bukhari, A.A., and Al-Malack, M.H. 2003. Seasonal variations in the bacterial population in an activated sludge system. J. Environ. Eng. and Sci., 2(2): 155-162.

Shuval, H.I., Adin, A.B., Fattal, E.R. and Yekutiel, P. 1986. Wastewater irrigation in developing countries: Health effects and technical solutions. World Bank Technical Paper No. 51. Washington, U.S.A: The World Bank.

Vigneswaran, S. and Sundaravadivel, M. 2004. Recycle and reuse of domestic wastewater, in Wastewater Recycle, Reuse, and Reclamation, in Encyclopedia of Life Support Systems (EOLSS), UNESCO, Eolss Publishers, Oxford, UK. Accessed on October, 2010. [http://www.eolss.net]

Virkutyte, J., Rokhina, E. and Jegatheesan, V. 2010. Optimisation of Electro-Fenton denitrification of a model wastewater using a response surface methodology. Bioresource Technol. 101(5): 1440-1446.

Vlyssides, A.G., Papaioannou, D., Loizidoy, M., Karlis, P.K., Zorpas, A.A. 2000. Testing an electrochemical method for treatment of textile dye wastewater. Waste Manag. 20(7): 569-574.

Yildiz, Y.$., Koparal, A.S., Keskinler, B. 2008. Effect of initial pH and supporting electrolyte on the treatment of water containing high concentration of humic substances by electrocoagulation. Chem. Eng. J. 138(1-3): 63-72.

Muhammad Saleem 1 , Alaadin A. Bukhari 2 and Muhammad Noman Akram 1 1 Karachi Institute of Power Engineering (KINPOE), KNPC, Karachi, Pakistan 2 Centre for Environment and Water, The Research Institute, King Fahd University of Petroleum & Minerals, Dhahran, Saudi Arabia Corresponding author: E-mail: i_am_saleem@yahoo.com
COPYRIGHT 2011 Asianet-Pakistan
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2011 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Publication:Journal of Basic & Applied Sciences
Article Type:Report