Determination of Silver in Rocks and Ores Samples using Modified Voltammetric Technique.

Byline: Afzal Shah, Salah Ud-Din Khan and Usman Ali Rana

Summary: Novel modified electrochemical method were used to analyze sedimentary, metamorphic, igneous, fined grained, coarse grain granite, granite with feldlaths and ferrogenous sand stone rocks along with boulangerite, stibnite, magnetite and scheelite ores for the presence of silver. Rocks and ores samples were processed through fire assay and acid digestion methods. Effect of various interfering metal ions was studied and it was observed that Hg(I) ions contributed maximum increment in the peak current of Ag(I). Differential pulse anodic stripping voltammetry (DPASV) and cyclic voltammetry (CV) were applied for the determination of silver. Glassy carbon bare and modified electrodes were used as working electrodes.

Platinum and saturated calomel electrodes were applied as auxiliary and reference electrodes respectively. The modified method has high affinity, selectivity and sensitivity and can be applied for trace level determination of metal ions. The limits of detection (LDL), quantification (LOQ) and linear regression coefficient (R2) were found 1.14g/L, 3.2g/L and 0.9969 respectively.

Keywords: Voltammetry, Electroanalytical Chemistry, Silver, Electrodes, Rocks, Ores.

Introduction

Silver is termed as precious metal due to its unusual production and greater requirements by community with significant economic values. It has valuable physical and chemical properties along with its industrial and trade uses. It is almost inert in chemical reactivity and possesses very shining properties with soft and flexible nature [1]. The precious nature of silver is due to its inadequate and distinctive production. It exists in combinations with other metals and nonmetals. Thus, the large amounts of less rare metals in the precursors lead to less uptake of silver [2]. Silver has been investigated to allocate its effects on the physiology of humankind and describe its medical advantages. Industrially, silver is highly important metal because more than 85% of the manufactured products involve its use. It has high market value and used as a conductor in various electronic devices, circuits and connectors [3].

Precious Metal Clay (PMC) corresponds to significant developments in the management of silver. PMC consists of very tiny particles of silver or gold floating in an organic binder [4]. Silver has a wide range of applications in jewellary, automobile, chemicals, petrol refineries, electrical, ceramic and glass industries [5-6]. Silver is also used in Xray photography, medicine (Ag2O, AgNO3, Argyrols) bactericide/antiseptic, oil and water purifier (Ag3PO4), tableware, corrosion control in batteries as well as in stable electrode and medals formation [7]. Pakistan has three significant kinds of rocks e.g. metamorphic, magmas and sedimentary which are used as precursors of precious metals. In these rocks, silver mostly exists in aggregation with gold and other metals. It is usually associated with sulphides of copper, arsenic, iron as well as compounds of selenium and antimony [8].

Some techniques like capillary zone electrophoresis [9], ET-AAS [10], solvent extraction [11-13], kinetic spectrophotometric methods [14-15], Ion-exchange [16], SF-ICP-MS [17], ICP-MS enzymatic [18], colorimetricsolid-phase extraction method [19], vapor generation-inductively coupled plasma atomic emission spectrometry and mass spectrometry [20], spectrophotometric [21], Liquid chromatography [22-23], rotating film per-traction [24], hydrometallurgical [25] and various electrochemical methods [26-28] have been used for the determination of silver.

In this current study, a novel modified, cost effective, robust and highly sensitive voltammetric method was proposed for the determination of silver from its precursors. Different working electrodes were used to notice the effect of electrode surface on peak signals.

Experimental

Analytical Techniques

The Waveform Generator PP RI, HITEK instruments England, UK with potentiostat, X-Y recorder and cell assembly possessing GCBE/GCME as working electrode, Pt as an auxiliary electrode and saturated calomel electrode (SCE) as a reference electrode were used for voltammetric determination of silver. pH meter, model inoLab of WTW was used for pH measurements. Pipetman Gilson Micropipettes of variable ranges were used for micro volume adjustments of the solutions. Controlled temperature furnace model 810-00-002 was used for fire assay method of the samples. Swiss-made precisa balance model XB 120A was used for weighing purpose. Electric oven model 8559 was used for drying purpose. Atomic Absorbtion Spectrometer (AAS) model Hitachi 180-50, Japan was used for comparative analysis.

Chemicals and Glassware

All chemicals were of high purity analytical grade, purchased from Fluka, Sigma-Aldrich and Fisher Scientific International Company. Standard aqueous solutions of Ag+/AgNO3, glacial CH3COOH, KCl, HNO3, NH4SCN and potassium hydrogen phthalate (KHP) were prepared in double distilled water respectively. 1% chitosan solution was prepared by dissolving 0.01g chitosan in 1 ml of 2M CH3COOH. All glassware was kept in a container having 3M HNO3 solution. These were then washed thoroughly with single distilled water and finally rinsed with double distilled water and dried in an oven for 1hour, cooled to room temperature and used for analytical work.

Sampling Profile

Samples of rocks and ores were collected from different regions of Pakistan. Natures of various sample locations were identified with help of Geology department. Description of various samples is given in Table-1.

Sample Treatment

The ores/ rocks samples were crushed and grinded in a jaw crusher and a ball mills to convert them into powder form. The powdered samples 80micron mesh sizes were then processed by fire assay method to remove the volatile oxides of Pb, Sb and S. After ignition, acid digestion processes were used to treat the ores and rocks samples accordingly. The solution was then concentrated by evaporating the solvent and diluted with double distilled water up to the desired concentrations of silver(I).

Table-1: Rocks and ores samples collected from different areas of Pakistan are given below.

Sample Code###Site of Collection###Physical Appearance###Remarks

###R1###Bakka Khail (NWA)###Brownish

###R2###Miran Shah (NWA)###Purple

###Sedimentary and Metamorphic

###R3###Mir Ali (NWA)###Dark Gray

###Basic Rocks

###R4###Karak (K.P.K)###Gray

###R5###Dara Pezzo (K.P.K)###Dark Brown

###Samples Collected from PCSIR Laboratories Karachi (Sindh)

###R6###Pink

###R7###Jam Khan jo Vandio (Sindh)###Dark Blue###Igneous Rock

###R8###Light Blue

###R9###Dark Green (Maleno Cratic)###Fined Grained Basic Rock

###R10###Ramji jo Vandio (Sindh)###Light Pink (Leuco Cratic)###Coarse Grain Granite Rock

###R11###do###do

###R12###Dark Gray

###R13###Light Gray###Basic Rocks

###Paradaro (Sindh)

###R14###Gray

###R15###do###Granite with feldlaths

###R16###Mukrio###Dark Green (Hyper Malenium)###Basic Rock

###R17###Kasbo###do###do

###R18###Dark Red

###On jo Vandio (Sindh)###Ferrogenous sand stone of Barthala formation

###R19###Yellow

###R20###Zardari Mine Nagar Parkar###Dark Red###do

###Ores Samples Collected from Mineral Testing Laboratories (MTL) Peshawar (K.P.K)

###S.#.###Ore Sample###Composition###Color

###1.###Boulangerite###Pb5Sb4S11###Blue and Grey to Brown

###2.###Stibnite###Sb2S3###Dark Grey

###3.###Magnetite###Fe3O4###Purple

###4.###Scheelite###Ca[WO4]###Greenish Grey

Preparation and regeneration of Glassy Carbon Modified Electrode (GCME)

The surface of glassy carbon electrode (GCE) was polished with 0.05 micron alumina slurry for 3-5 minutes, sonicated for 5-10min and rinsed with double distilled water. The electrode was then dried under nitrogen gas to make it ready for voltammetric analysis and modification by organic ligands. A drop of 1% chitosan solution was applied on the cleaned surface of GCE with the help of a dropping capillary. Then it was placed under UV light for 20min in order to get the chitosan dried and firmly attached to the surface of GCE. For new analysis the GCME was regenerated by placing in 2M acetic acid to remove the chitosan and repeat the process from polishing with alumina to drying the chitosan on the surface of glassy carbon electrode.

Methodology

Voltammetric analyses were carried out through a cell assembly containing three electrodes system. A 10mL blank solution only containing supporting electrolytes/buffers was taken in the electrochemical cell and purged with nitrogen gas to remove the dissolved oxygen. It was then electrolyzed under the controlled parameters and background voltammograme was recorded. The aforementioned procedure was also adopted for analyzing the analyte solutions containing Ag(I) ions and same amount of supporting electrolytes/ buffers and thus voltammograms were recorded for Ag(I) ions.

Results and Discussion

Effect of pH on Peak Current of Ag(I)

pH is a very sensitive parameter and causes variation in analytical results. The maintenance of pH by using a proper buffer system is thus highly demanded because small amount of CO2 can alter the actual pH value of the solution if a single acid/alkali is used for pH adjustment. This may produce disturbance in the peak signal and may increase noise in signal. Fig. 1 represents the change in peak current values with variation in pH of the solution. It can be seen from Fig. 1 that maximum peak current value of 15.7A is true at a pH value of 4.1.

Some researchers [29] have reported 0.1M potassium nitrate for pH adjustment. Some other researchers [30] have studied a pH range of 3.5 to 7.0 for silver determination using modified carbon paste electrode. They used citrate buffer and noticed that pH value 6.0 gives maximum peak current. In current studies 0.05M [NH4SCN and potassium hydrogen phthalate] buffer system with trace amount of 0.005M NH3 were used for pH adjustments.

Effect of Pulse Amplitude on Peak height of Ag(I)

The effect of pulse amplitude was optimized to obtain well shaped peak signals with higher current values. It can be observed from Fig 2 that 100mV pulse amplitude with 100mV/sec scan rate gives maximum peak current for Ag(I). In case of silver determination different pulse amplitudes were reported by various researchers such as 25mV pulse amplitude with 5mV/s scan rate by [31], 10mV pulse amplitude with 100mV/s scan rate by [32] and 250mV pulse amplitude by [33].

The aforementioned pulse amplitude values depend upon nature of electrolytes/ buffer system and type of voltammetry whether DPASV or CV. In current studies, it was also noticed that at very higher scan rates peak signals are distorted due to broadening effect. However, the slower scan rate is advantageous for a higher peak current using DPASV. A scan rate of 100mV/sec for determination of Ag(I) using cyclic voltammetry was also suggested [34].

Effect of deposition time without stirring on Peak Current of Ag(I)

Fig 3 describes the change in peak current with deposition time for Ag(I) standard solution by keeping all other parameters constant. It can be seen from Fig 3 that maximum peak current was obtained at 5min deposition time. This may be due to the maximum pre-concentration of the analyte Ag(I) and its peeling off after deposition which may be due to the solution's affinity. The decrease in peak currents of Ag(I) beyond the optimum deposition time may be due to the formation of oxides and fading of electrode surface as well as degradation of electrolyte contents with the passage of electric current for longer times. In literature [31, 32, 34], optimum deposition time of 3, 5 and 10 min was proposed for the analyses of silver ions. Hence, in current studies the optimum value of deposition time is quite closer to some referenced the literature.

Effect of deposition time followed by stirring on peak current of Ag(I)

Stirring time effect was optimized for maximum peak current response of Ag(I) ions from standard aqueous solutions under the influence of already optimized parameters. It can be observed from Fig 4 that the peak current increases up to some limits with the use of stirring along with deposition time. Stirring offers frequent transfer of metal ions from solution matrix to electrode surface and increase the rate of deposition while decrease the required time for this deposition. In this case the maximum peak current value was obtained with 4 minutes deposition time followed by stirring. Such studies are not common in literature, yet some researchers [31] have described this parameter as a constant value.

Effect of nitrogen purging time on peak current of Ag(I)

The nitrogen (N2) or other inert gas is purged to remove oxygen from the solution matrix because oxygen causes noise to signal ratio and distorts peak signals. It is apparent from the Fig. 5 that N2 purging of 10min followed by 4min electrolysis time gives greater peak current value for silver(I) determination. The N2 purging was performed to make the peak signals smoother and well resolved. Various researchers [31-32, 35-37] have reported such studies of using inert gas for de- aeration of aqueous solutions containing metal ions.

Effect of temperature on peak Current of Ag(I)

Temperature has profound effect on the mobility of ions and internal energy of matter, which accelerate convection. It is evident from Fig. 6 that the peak current increases with increase in temperature from 1035C in a nearly linear fashion but decreases thereafter. However, 25C was selected as optimum temperature because during calibration studies it was noticed that the linear regression value was lesser for 30C and above as compared to 25C. The increase of peak current with temperature up to 35C may be due to the convection phenomenon, which enhances the mobility of ions towards cathode. The decrease in peak current beyond this temperature may be due to the evaporation of electrolytes, which may disturb complex formation and decrease current carrying capacity. Similar findings of temperature effect on peak current have been reported in literature [31].

Effect of Interfering Metals

Although the effect of others interfering metals on electrochemical behavior of silver ions is not essential because the formers can be eliminated as their volatile oxides at higher temperature using fire assay method. The lead button formed after performing the fire assay method was treated with HNO3. However, interference effect of metal ions was studied to find out a metal which produces highest positive interference for Ag(I) and that could be helpful for lowering the detection limit of Ag(I).

Table-2 shows the interference effect of some metals, which may be present with Ag(I) in ores and rocks. Table-2 indicates that Hg(I) ions have the highest positive interference of 85.5% with an enhanced peak current of 115.3A. Arsenic(III) contributed, the positive interference and Ba(II) ranging from +29.8 to +1.6 respectively while Fe(III) to Cl-1 show negative interference ranging from 2.9 to 38.1 respectively. The effect of various metal ions and anions on silver determination was studied [40]. However, they have not reported the use of Hg(I) ions as interfering specie in this study. Interference effect during anodic stripping voltammetry of metals is mainly due to the formation of intermetallics as reported earlier. They studied strong catalytic effect of Au(III) on the slow redox reaction between Ce(IV) and Hg(I) in a sulphuric acid medium at 90C.

Some positive interferon's may also be considered for the enhancement of peak signals of Ag(I) ions but the addition of more metals may result in complication and production of metallic contamination. Usually the interference by metals can be removed with the use of suitable masking agents [38-42] but this may also make the process complicated and costly. Some researchers [28, 43-44] have reported that interfering metals bind the significant analyzing metal due to intermetallic behavior and thus alter its redox properties.

Metals with strong intermetallic behavior and less polarizability may result in suppressing the peak signals and metals with soft intermetallic behavior and more polarizability may cause increment in peak signals for Ag(I). In the current studies the positive interference by Hg(I) was used for lowering the LDL for determination of Ag(I) ions by DPASV. In literature, [45] have also explained the interference effect of co-existing substances on the peak current of analyte species. A modified form of Nikolsky-Eisenman equation was used to determine selectivity coefficient (Kamp) for the sensor [46-48].

Effect of Hg (I) Conc., on Peak Current of Ag(I)

Fig 7 shows the effect of Hg(I) ions concentration on peak current values of Ag(I) from standard aqueous solutions at others optimized parameters. Studies on the electrochemical behavior of Hg(I) concentration on Ag(I) are not common in the literature. However, a scientist [42] has studied the effect of Hg(I) concentration on Au(III) and reported that at higher concentrations of Hg(I) results become constant. In our case, the intermetallic effect of Hg(I) on Ag(I) follow the same mechanism as described for Au(III). The results in Fig 7 show that there is a gradual increment in the peak current of Ag(I) with increase in the concentration of Hg(I) up to 0.1g/ml and decreased thereafter. Maximum peak current 153.45A was recorded at 0.1g/ml of Hg(I) and 2g/ml of Ag(I).

This decrease in the peak current of Ag(I) may be due to the inhibition effect of higher concentrations of Hg(I), while the increase in peak signals of Ag(I) by addition of Hg(I) may be due to the redox reaction between Ag(I) and Hg(I). Hence, the increment in peak current of Ag(I) may be due to greater reducing effect of Hg(I). The reducing effect of Hg(I) on Ag(I) promotes the accumulation of large amounts of Ag(0) on electrode surface and hence increases the peak signal. Moreover, mercury has the ability to dissolve silver.

This is very rapid and independent of time kinetics. Electrolysis provides a favorable medium for more rapid contact between mercury and silver [49]. Oscillations in the current suggest the formation and dissolution of Ag- Hg species. Regarding the Ag-Hg, a passive layer formation begins on the surface of electrode, which lowers currents, while an increment in current values track the dissolution and oxidation processes [50]. The higher concentration of mercury may produce an excess amount of Hg complex instead of Hg(l). This may decrease the chances of intermetallic contacts between silver and mercury. Moreover, an excess amount of mercury may produce strong intermetallics, may cover more area on the surface of working electrode, and reduces peak signal for Ag(I).

Table-2: Interference effects of various metal ions on peak currents of Ag(I) using DPASV.

Metal ion###Peak currentn=3###Interference effect###Metal ion###Peak currentn=3###Interference effect

(2g/ml)###(A)a###%###Kamp###(2g/ml)###(A)a###%###Kamp

###No ion###62.0###----###----###Fe+3###60.2###-2.9###-0.029

###Hg+1###115.3###+85.5###0.860###Pb+2###58.0###-6.5###-0.065

###+3

###As###80.5###+29.8###0.298###Ca+2###56.8###-8.4###-0.084

###Ce+5###75.0###+21.0###0.210###Zn+2###56.6###-8.7###-0.087

###+2

###Cd###70.5###+13.7###0.137###Ni+2###55.9###-9.8###-0.098

###+2

###Cu###69.7###+12.4###0.124###Sn+2###54.1###-12.7###-0.127

###+2

###Hg###68.4###+10.3###0.103###I-1###53.0###-14.5###-0.145

###+3

###Au###67.2###+8.4###0.084###Br-1###48.2###-22.3###-0.223

###+6

###Cr###66.1###+6.6###0.066###Cl-1###38.4###-38.1###-0.381

###+2

###Ba###63.5###+1.6###0.024###----###----###----###----

Comparison of Voltammetric Signals

Polarization peak signals were recorded for the determination of silver(I) using different working electrodes as shown in Fig. 8. The curve (a) indicates the electrochemical peak signal obtained via GCBE for Ag(I) determination. Curve (b) describes the electrochemical peak signal for Ag (I) using GCME. Curve (c) shows electrochemical peak signal with GCBE for standard aqueous solution containing Ag (I) and treated with an optimum amount of Hg (I) ions.

It is evident from Fig 8 that the response of GCBE is obviously higher for Ag(I) standard aqueous solutions treated with an optimum concentration of Hg(I). The peak signals recorded for Ag(I) by using different electrodes systems show different peak potential values. The shift in peak potential may be due to the affinity/force of interaction between Ag(I) ions and the surface where it was deposited. The electrode response for Ag(I) ions treated with controlled quantity of Hg(I) ions is about 3 folds higher than untreated Ag(I) ions. It means that the presence of Hg(I) catalyze the peak signal of Ag(I).

Calibration Curves and Plots

Silver determination was carried out in the concentration range of 0.043.0g/ml with linear regression coefficient of 0.9951 for untreated Ag(I) standard aqueous solutions using GCME (Fig. 9 and 11) and the linear calibration plot for concentration range 0.012.0g/ml with linear regression coefficient of 0.9969 was obtained for standard aqueous solutions of Ag (I) treated with controlled concentration of Hg(I) ions using GCBE (Fig 10 and11).

A researcher [36] has reported a detection limit of 2.5A-10-7M (26.98g/L) for silver determination using chemically modified carbon paste electrode. The LDL 1.14g/ L in our studies is highly comparable and significant to the LDL noticed from the literature e.g. some authors [32] have given the value of LDL 1A-10-8M (1.08g/L) for silver determination using voltammetric techniques. In current studies the lower detection limit (LDL) was calculated as per procedure [51].

Cyclic Voltammogram

The cyclic voltammogram (Fig12) for Ag(I) shows two peak signals (i) the anodic peak at -20mV and (ii) the cathodic peak at -240mV. The potential difference between the anodic and the cathodic peak signals can be calculated as; (Equation) and the ratio of peak currents, (Equation). Thus, (Equation), hence, all these reveal the quasi-reversible behavior and mechanism of electrode reaction for silver deposition and stripping [52-54].

Sample Analysis

Table-3 shows the results for Ag(I) concentration in various digested ores and rocks samples. The digested samples were diluted up to desired range for voltammetric and spectroscopic analyses (Table-3). The results obtained for Ag(I) by atomic absorption spectroscopy [55] are in close accordance with the results obtained by DPASV, which shows the validity and precision of the developed voltammetric method for Ag(I) determination from its precursors.

Table-3: Application of Method: Comparative results showing presence/absence of Ag (I) in digested ores and rock samples by developed voltammetric method and AAS.

###Silver (I) Determination (g/ml)a

###Samples###By new method###By AAS

###(1000 fold) Dilution###Actual value###(250 fold) Dilution###Actual value

###Boulangerite###0.0230.03###22.7###0.090.09###22.1

###Magnetite###N.D.###N.D.###N.D.###N.D.

###Sheelite###N.D.###N.D.###N.D.###N.D.

###Rock 1###0.0260.11###26.4###0.110.14###26.9

###Rock 2###0.0330.14###33.2###0.130.25###33

###Rock 3###0.0180.09###17.9###0.070.19###18.5

Conclusion

The surface of glassy carbon electrode modified with chitosan showed high sensitivity for silver ions in comparison to bare surface of the same electrode. Chitosan molecules undergo complexation reactions with metal ions. Hence, the affinity and sensitivity of Chitosan modified surface to silver ions may be higher than the bare surface of carbon. Rock samples (1-3) are first time described as new precursors of silver.

However, Boulangerite ore collected from mountains of Pakistan was also found a good source of silver. Glassy carbon modified electrode (GCME) was more optimal and sensitive for trace level determination of Ag(I). However, the addition of Hg(I) ions further increased the peak currents. The more increase in peak currents by addition of Hg(I) may be due to intermetallic effect and reducing behavior of Hg(I) ions. Hg(I) ions can be used for catalytic purpose to lower the limit of detection. Cyclic voltammogram confirmed the redox reactions followed by the deposition and stripping of silver. The modified electrochemical method is robust, sensitive, cost effective and applicable to all kinds of aqueous sample solutions containing Ag(I) ions.

Acknowledgement

The authors would like to appreciate the Higher Education Commission (HEC), Islamabad, Pakistan for research support fellowship at University of Wales, United Kingdom and Monash University, Australia. Moreover, the authors also acknowledge the support of the Deanship of Scientific Research at King Saud University via Research Group Project no RGP-VPP-255. The authors are highly grateful to Director Mineral Testing Laboratories, Peshawar, Khyber Pakhtunkhwa, Pakistan for providing some important ores samples. The authors declare that there are no conflicts of interest regarding the publication of this article.

References

1. B. Salih, O. Celikbicak, S. Doker and M. Dogan, Matrix Elimination Method for the Determination of Precious Metals in Ores Using Electrothermal Atomic Absorption Spectrometry, Anal. Chim. Acta., 587, 272 (2007).

2. A. Shah, Ph.D, Electrochemical Evaluation and Recovery of Precious Metals from Some Pakistani Ores and Rocks, University of Sindh, Jamshoro, (2008).

3. L. Gardner, Lost Secrets of the Sacred Ark; Amazing Revelations on the Incredible Power of Gold, ISBN: 000714296X, 9780007142965, HarperCollins, London (2004).

4. M. Grimwade, Introduction to Precious Metals, Publishers, ISBN; 1408122634, 9781408122631, A and C Black (2010).

5. F. Rani, I. H. Khan, F. Mahmood and M. Z. Iqbal, Studies on the Leaching of Copper from Complex Copper Ores of Chitral, Pak. J. Sci. Indust. Res., 41, 139 (1998).

6. M. Cox, A. A. Pichugin, E. I. El-Shafey and Q. Appleton, Sorption of Precious Metals onto Chemically Prepared Carbon from Flax Shive, Hydrometall., 78, 137 (2005).

7. M. Harper and J. M. Siegel, Comparison of Discharge Silver Concentrations from Electrolytic Plating and Metallic Replacement Silver Recovery Units, J. Air and Waste Manag. Asso., 53, 434 (2003).

8. A. H. Kazmi and S. G. Abbas, Metallurgy and Mineral Deposits of Pakistan, ISBN; 696-837501-5, Orient Petroleum Incorporation Hayat Hall, Islamabad, 1, p. 120 (2001).

9. M. Aguilar, A. Farran and M. Martinez, Determination Of Gold(I) And Silver(I) Cyanide In Ores By Capillary Zone Electrophoresis, J. Chromatography A., 635, 127 (1993).

10. K. Ohta, S. Kaneco, S. I. Itoh and T. Mizuno, Electrothermal Atomic Absorption Spectrometric Determination of Silver In Biological Materials with a Molybdenum tube atomizer, Anal. Chim. Acta., 267, 131 (1992).

11. A. Chatterjee and S. Basu, Solvent Extraction of Silver(I) with Amberlite-LA-2 using110mAg as Tracer, J. Radioanal. Nucl. Chem., 162, 259 (1992).

12. V. Stankovic, L. Outarra, F. Zonnevijlle and C. Comninellis, Solvent Extraction of Silver from Nitric Acid Solutions by Calix[4]arene amide derivatives, Sep. Purif. Tech., 61, 366 (2008).

13. M. A. Rabah, K. A. E. Barawy and F. H. Aly, Silver Recovery From Spent Colour- Photography Solutions, Internat. J. Miner. Proces., 26, 17 (1989).

14. D. Wilms, K. Vercaemst and D. J. C. Van, Recovery Of Silver By Crystallization Of Silver Carbonate In A Fluidized-Bed Reactor, Water Res., 26, 235 (1992).

15. Y. J. Chen, Y. B. Wang and G. H. Li, Microware digestion-catalytic kinetic spectrophotometric determination of trace silver in geological samples from gold ore, Metall. Anal., 27, 48 (2007).

16. M. Tabatabaee, M. R. Nateghi and S. J. Mosavi, Kinetic-Spectrophotometric Determination of trace amounts of silver using the oxidation of thionine with peroxodisulfate, Anal Sci., 22, 1601 (2006).

17. N. B. Dubey and H. K. Bagla, Ion-exchange studies of 110mAg(I) using synthetic inorganic ion-exchanger, J. Radioanal. Nucl. Chem., 274, 271 (2007).

18. J. L. Barriada, A. D. Tappin, E. H. Evans and E. P. Achterberg, Dissolved silver measurements in seawater, TrAC Tren. Anal. Chem., 26, 809 (2007).

19. N. Nakiboglu, D. Toscali and I. Yasa, Silver Recovery from Waste Photographic Films by Using Enzymatic Method. Turkish J. Chemi., 25, 349 (2001).

20. M. P. Arena, M. D. Porter and J. S. Fritz, Rapid, low level determination of silver(I) in drinking water by colorimetricsolid-phase extraction, Anal. Chim. Acta., 482, 197 (2003).

21. X. Duan, R. L. McLaughlin, I. D. Brindle and A. Conn, Investigations into the generation of Ag, Au, Cd, Co, Cu, Ni, Sn and Zn by vapour generation and their determination by inductively coupled plasma atomic emission spectrometry, together with a mass spectrometric study of volatile species. Determination of Ag, Au, Co, Cu, Ni and Zn in iron, J. Anal. At. Spectrom., 17, 227 (2002).

22. E. H. El-Mossalamy and A. S. Amin, Spectrophotometric studies of 4-(2-hydroxy-4- substituted-azobenzene)-2-methyl-quinolines as reagents for the determination of silver, Chem. Month., 128, 23 (1997).

23. M. Y. Khuhawar and G. M. Arain, Liquid Chromatographic Determination of Cobalt(II), Nickel(II) and Silver(I) using 6-Methyl-2- pyridine Carboxaldehyde Isonicotinoyl Hydrazone as Derivatizing Reagent, Asian J. Chem., 19, 1319 (2007).

24. R. Mikelova, J. Baloun, J. Petrlova, V. Adam, L. Havel, J. Petrek, A. Horna and R. Kizek, Electrochemical determination of Ag-ions in environment waters and their action on plant embryos, Bioelectrochem., 70, 508 (2007).

25. L. Boyadzhiev and K. Dimitrov, Recovery of silver from nitrate solution by means of rotating film pertraction, J. Memb. Sci., 86, 137 (1994).

26. C. A. Fleming, Hydrometallurgy of precious metals recovery, Hydrometallurgy, 30, 127 (1992).

27. E. Lorenzo and H. D. Abruna, Determination of silver with polymer-modified electrodes, J. Electroanal. Chem., 328, 111 (1992).

28. J. Runnurags, P. Sukhotu and P. Chooto, Voltammetric Determination of Silver(I) Using Carbon Paste electrode Modified with 1,8- Dihydroxyanthraquinone, Meeting Abs., 205, 14 (2004).

29. H. Ibrahim, Carbon paste electrode modified with silver thimerosal for the potentiometric flow injection analysis of silver(I), Anal. Chim. Acta., 545, 158 (2005).

30. M. Khodari, M. M. A. Krisha and R. Fandy, Determination of Ag(I) with chemically modified carbon paste electrode based on 2,3- dicyano 1,4-naphthoquinone, Talanta., 41, 2179 (1994).

31. M. S. Won, J. S. Yeom, J. H. Yoon, E. D. Jeong and Y. B Shim, Determination of Ag(I) Ion at a Modified Carbon Paste Electrode Containing N,N'-Diphenyl Oxamide, Bull. Korean Chem. Soc., 24, 948 (2003).

32. R. K. Shervedani and M. K. Babadi, Application of 2-mercaptobenzothiazole self-assembled monolayer on polycrystalline gold electrode as a nanosensor for determination of Ag(I), Talanta, 69, 741 (2006).

33. R. Mikelova, V. Adam, L. Trnkova, P. Babula, A. Horna and R. Kizek, Analysis of silver ions by stationary and flow electrochemical techniques on the surface of glassy carbon electrode, biomed. Papers, 149, 17 (2005).

34. Y. H. Li, H. Q. Xie and F. Q. Zhou, Alizarin violet modified carbon paste electrode for the determination of trace silver(I) by adsorptive voltammetry, Talanta, 67, 28 (2005).

35. H. Shin and C. Kang, Adhesion of gold nanoparticles on an electrochemically pretreated glassy carbon electrode, Anal. Sci., 19, 1667 (2003).

36. F. D'Eramo, J. J. Silber, A. H. Arevalo and L. E. Sereno, Electrochemical detection of silver ions and the study of metalpolymer interactions on a polybenzidine film electrode, J. Electroanal. Chem., 494, 60 (2000).

37. A. Mohadesi and M. A. Taher, Stripping voltammetric determination of silver(I) at carbon paste electrode modified with 3-amino-2- mercapto quinazolin-4(3H)-one, Talanta, 71, 615 (2007).

38. W. K. Choi and H. M. Lee, Effect of Ni layer thickness and soldering time on intermetallic compound formation at the interface between molten Sn-3.5Ag and Ni/Cu substrate, J. Electron. Mater., 28, 1251 (1999).

39. P. Cofre and K. Brink, Determination of gallium by anodic stripping square-wave voltammetry Detection of a GaZn intermetallic compound and its destruction by Sb in an NaSCNNaClO4 supporting electrolyte, Talanta, 39, 127 (1992).

40. A. L. B. Marques and G. O. Chierice, Elimination of the copper"zinc interference in anodic stripping voltammetry by addition of a complexing agent, Talanta, 38, 735 (1991).

41. G. E. M. Hall and J. E. Vaive, Determination of gold in geological samples by anodic stripping voltammetry at field locations, Chem. Geolog., 102, 41 (1992).

42. Z. L. Jiang, A novel and highly sensitive catalytic method for the determination of ultratrace amounts of gold in ores with linear scan voltammetry at a DME, Talanta, 40, 1823 (1993).

43. D. Desmond, B. Lane, J. Alderman, G. Hall, M.A. Icaza, A. Garde, J. Ryan, L. Barry, G. Svehla, D.W.M. Arrigan and L. Schniffner, An ASIC-based system for stripping voltammetric determination of trace metals, Sensor. Actuat. B: Chem., 34, 466 (1996).

44. E. P. Gil and P. Ostapczuk, Potentiometric stripping determination of mercury(II), selenium(IV), copper(II) and lead(II) at a gold film electrode in water samples, Anal. Chim. Acta., 293, 55 (1994).

45. E. A. Sosnin, Y. N. Batalova, E. Y. Buyanova and V. F. Tarasenko, Proceedings of the International Conference, PhysCon, St. Petersburg, Russia, 1, 349 (2003).

46. J. Wang, Selectivity coefficients for amperometric sensors, Talanta, 41, 857 (1994).

47. K. Ren, Selectivity problems of membrane ion- selective electrodes, Fresenius J. Anal. Chem., 365, 389 (1999).

48. R. I. Stefan, Electrochemical sensors in bioanalysis, ISBN; 0824706625, 9780824706623, CRC press, p. 60 (2001).

49. C. Bracho-Troconis, P. Colon, J.D. Bartout and Y. Bienvenu, Influence of thermal treatments on Ag Sn Cu powders in order to reduce mercury contents in dental amalgam, J. Mater. Sci.- Mater. Med., 11, 1 (2000).

50. H. A. Acciari, A. C. Guastaldi and C. B. M. A. Brett, Corrosion of dental amalgams: electrochemical study of AgHg, AgSn and Sn Hg phases, Electrochim. Acta., 46, 3887 (2001).

51. C. Locatelli, Simultaneous square wave stripping voltammetric determination of platinum group metals (PGMs) and lead at trace and ultratrace concentration level: Application to surface water, Anal. Chim. Acta., 557, 70 (2006).

52. K. Yoshizuka, Z. Lou and K. Inoue, Silvercomplexed chitosan microparticles for pesticide removal, React. Funct. Polym., 44, 47 (2000).

53. O. Chailapakul, M. Amatatongchai, P. Wilairat, K. Grudpan and D. Nacapricha, Flow-injection determination of iodide ion in nuclear emergency tablets, using boron-doped diamond thin film electrode, Talanta, 64, 1253 (2004).

54. S. Chen, G. Wu and H. Zeng, Preparation of high antimicrobial activity thiourea chitosan Ag+ complex. Carbohyd. Polym., 60, 33 (2005).

55. A. Tunceli and A.R. Turker, Flame atomic absorption spectrometric determination of silver after preconcentration on Amberlite XAD-16 resin from thiocyanate solution, Talanta, 51, 889 (2000).
COPYRIGHT 2015 Asianet-Pakistan
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2015 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Publication:Journal of the Chemical Society of Pakistan