Printer Friendly

DIAGNOSTIC ACCURACY OF CONE-BEAM COMPUTED TOMOGRAPHY IN DETECTING SECONDARY CARIES UNDER COMPOSITE FILLINGS: AN IN VITRO STUDY/Kompozit Rezin Restorasyonlarda Sekonder Curuk Lezyonlarinin Teshisinde Konik Isinli Bilgisayarli Tomografinin Tanisal Dogrulugu.

Introduction

Cone-beam computed tomography (CBCT) provides accurate and detailed information for diagnosis and treatment planning of dentomaxillofacial pathologies. CBCT produces three dimensional images with high resolution of bony structures and also the radiation dose of CBCT is lower than computed tomography (CT) (1, 2). Thus, it is used for various purposes such as dental implant planning, oral and maxillofacial surgery, orthodontics, airway assessment, temporomandibular joint disorders, endodontics and periodontics (3-8). In recent studies, the efficacy of CBCT has been evaluated for caries diagnosis. Some of them have concluded that the accuracy of CBCT may be similar to that of intraoral digital radiographic images for occlusal and proximal caries detection (9-12). However, CBCT images were found to be superior to intraoral techniques in other studies for secondary caries lesions under both composite and amalgam restorations (13-15). On the other hand, some authors reported that diagnostic performance of CBCT in detecting secondary caries may be negatively affected by the presence of dental restorations because of metal artifacts (16). There is still no justification regarding the use of this modality for caries detection. CBCT scanning is unnecessary for caries detection; it can only be used when it is taken for other reasons.

As x-ray beam passes through an object, low energy photons become more likely to be absorbed than high energy photons and this is called "beam hardening". Metal objects lead to artifacts in CBCT images related to beam hardening because absorption of x-ray beam is greater for metal objects than human tissues and cupping, as well as streaking artifacts may occur. Cupping artifacts are seen as distortion around the metallic objects and streaking artifacts are seen as dark and bright bands between two objects with high density (17). Because of their low attenuation values, the use of composite resins has been suggested to reduce artifacts before CBCT examination (18). There are limited number published articles in the literature regarding secondary caries detection by using CBCT. Also, there are no published studies about the diagnostic performance of CBCT for secondary caries detection in different type of cavities filled with composite resin. The aim of this in vitro study was therefore to evaluate the diagnostic performance of CBCT in the detection of secondary caries lesions created under different types of composite resin fillings.

Materials and Methods

Specimen preparation and experimental procedure

Eighty four extracted human permanent posterior teeth were used in this study (N=84). Teeth with tissue loss and/or fillings were excluded. All the teeth were randomly divided into three groups according to type of cavities. The first group was prepared as occlusal cavities (0) (n=24), the second group was prepared as mesial and/or distal occlusal cavities (MO/DO) (n=30), and the third group was prepared as mesial--occlusal--distal cavities (MOD) (n=30). In each group, artificial secondary caries lesions were created in half of the cavities. The artificial caries lesions were prepared with round steel bur in 1 mm diameter, the location of the artificial holes on the base of the cavity was randomly selected. The drilled holes were then filled with pink wax. All groups of teeth were restored by composite resin (CR) (Valux plus, 3M Dental Products, St. Paul, MN, USA). For composite resin restoration, the cavities were etched for 15 seconds, bonding agent was applied and then cured for 40 seconds.

Premolar and molar teeth with approximal contacts were positioned in silicone blocks in a blind manner (Figure 1).

There were 21 blocks that contain four teeth each. Seven different block type was created according to various arrangements of tooth sets. There were three sums for each type of block. Half of the teeth with MOD (n=15) and DO/MO composite filling (n=15) were positioned to be adjacent approximal surfaces with restoration and the other half were located to adjacent approximal surfaces without restoration.

In total, 84 teeth with 24 O, 30 MO/DO and 30 MOD restorations were arranged to simulate various situations in the oral cavity. The number of teeth with 0 restorations (n=24) was lower than that of the MO/DO and MOD restorations (n=30). Arrangement of tooth sets and type of blocks are shown in Table 1.

Image acquisition and evaluation protocols

All blocks were radiographed by ProMax 3Ds CBCT system (Planmeca Oy, Helsinki, Finland). This device was operated at 90 kVp and 6.3 mA with 5x5 cm field of view (FOV) in high resolution settings. The acquired data were reconstructed with 0.48 mm slice thickness. Romexis Viewer (Planmeca Oy, Helsinki, Finland) software was used to evaluate the images in three orthogonal planes. Examples of CBCT images are shown in Figure 2. All images were evaluated by two oral and maxillofacial radiologists on two separate sessions with at least one week interval. The images were displayed on a 19-inch LCD monitor (Dell Inc., Round Rock, TX, USA). The observers were free to modify image algorithms but they did not have access to raw data. The presence or absence of secondary caries was scored using a five-point confidence scale; 1=definitely no caries, 2=probably no caries, 3=questionable, 4=probably caries, 5=definitely caries. Since there must be a final judgement under clinical conditions, scores 3, 4 and 5 were classified as positive diagnosis for caries whereas scores 1 and 2 were considered as negative diagnosis for caries.

Statistical analysis

The Kappa (k) coefficient values of intra- and inter-observer agreements were calculated and the values with higher than 0.7 were denoted as acceptable consistency. SPSS version 19.0 (SPSS Inc., Chicago, IL, USA) was used for statistical analysis. The area under ([A.sub.z]) the receiver operating characteristic (ROC) curve was used to evaluate the diagnostic accuracy. The areas under the curves were compared using Z-tests and p values less than 0.05 were considered as statistically significant.

Results

The k coefficients were 0.89 and 0.79 for intra- and inter-observer agreement, respectively. The areas under the ROC curves ([A.sub.z] values), sensitivity and specificity values of two observers were presented in Figure 3 and Table 2. [A.sub.z] values of the second observer was higher than the first observer. Sensitivity of the first observer was higher than the second observer while specificity of the second observer was higher than that of the first observer (Table 2). The areas under the ROC curves (Az values), sensitivities and specificities for each observers and cavity types were given in Table 3. The Az values of two observers were the highest for the O restorations, followed by the MOD and DO/MO restorations, respectively. Az values for MOD and DO/MO restorations were very low and diagnostic accuracy based on sensitivity and specificity values was not statistically significant. In simpler terms, sensitivity for DO/MO restorations and specificity for MOD restorations were found to be the lowest values.

Discussion

The diagnostic accuracy of CBCT was tested in different types of cavities with composite restorations for secondary caries detection in the present study. The burr with one-mm-diameter was used to simulate secondary caries under restorations in accordance with previous studies (15, 19). The use of small burs has been recommended since larger burs were found to be ineffective for simulation of caries lesions (19).

In earlier studies (15, 20), the researchers have standardized the position of artificial caries lesions, however, occurrence of caries in a standard location is unrealistic for clinical situation. Therefore, we created random artificial holes on the base to evaluate the performance of CBCT. In this study, the small voxel size and FOV were selected for CBCT scanning because reducing field size has been reported to increase spatial resolution and image quality (21). It is well known that the beam hardening artifacts occur with amalgam during CBCT scanning (16). Metal artifacts seen in CBCT images restricted the diagnosis of caries under restorations (15). Dark bands around the metallic restorations may look like secondary caries which may lead the clinicians to reach false positive diagnosis (16, 22). It is also suggested that composite resin fillings could be useful for improving diagnostic accuracy of CBCT (18). But in contrast, recent studies showed that composite fillings were not superior to amalgam in terms of secondary caries detection with CBCT (15, 20). Based on this contradictory findings, it can be stated that the clinical performance of CBCT in the detection of secondary caries under composite resin fillings still remains unclear. In the present study, the diagnostic accuracy of CBCT in the detection of simulated secondary caries under composite resin restorations were found to be highest for the O type of restorations. In addition, its sensitivity for DO/MO restorations and its specificity for MOD restorations were found to be the lowest values. Sensitivity is defined as the percentage of true positive answers while specificity is the percentage of true negatives (23). In other words, the observers were unable to detect true positive cases in DO/MO restorations and also the true negative cases in MOD restorations. This finding could be attributed to the increased intensity of the artifacts which has been found to correlate positively with the restoration size. Nabha et al. (18) assessed artifacts induced by O, MO/DO, MOD amalgam restorations with CBCT and concluded that increasing amalgam restoration size has caused higher intensity of artifacts on CBCT images. Even though the density of composite resin is lower than that of the amalgam, it is still higher than that of the enamel (24). Thus, it can be stated that composite resin may lead to beam hardening artefacts as well, which makes it harder to detect secondary caries under such fillings. In this context, the findings of the present study are not consistent with those of previous reports which claim that the composite resin improves diagnostic accuracy of CBCT (18). The [A.sub.z] values of two observers were found to be between 0.813 and 0.875 for O restorations, 0.553 to 0.560 for MOD restorations and 0.589 to 0.575 for DO/MO restorations. In previous studies, accuracy of CBCT were found to be between 75% 97% for occlusal and class 2 cavities respectively in detecting secondary caries lesions restored with composite fillings (16, 20). Such inconsistencies may arise from difference in study designs, evaluation criteria, and experience of the observers as well as observers' backgrounds.

Conclusion

The in vitro diagnostic performance of CBCT in detecting secondary caries is higher for O composite restorations than for MOD and DO/MO restorations. In addition, CBCT is a reliable imaging method for the detection of secondary caries under O composite restorations. Further clinical studies are needed to determine the accuracy of CBCT for secondary caries detection under different restorative materials.

Source of funding

None declared

Conflict of interest

None declared

References

(1.) Bianchi S. AS, Castellano S., Rizzi, L., Ragona R. Absorbed doses and risk in implant planning: Comparison between spiral ct and cone beam ct. Dentomaxillofac Radiol. 2001;30:28.

(2.) Tsiklakis K, Donta C, Gavala S, Karayianni K, Kamenopoulou V, Hourdakis CJ. Dose reduction in maxillofacial imaging using low dose cone beam CT. Eur J Radiol 2005;56(3):413-417.

(3.) Drage NA, Sivarajasingam V. The use of cone beam computed tomography in the management of isolated orbital floor fractures. Br J Oral Maxillofac Surg 2009;47(1):65-66.

(4.) Garrett BJ, Caruso JM, Rungcharassaeng K, Farrage JR, Kim JS, Taylor GD. Skeletal effects to the maxilla after rapid maxillary expansion assessed with cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2008;134(1):8-9.

(5.) Guerrero ME, Jacobs R, Loubele M, Schutyser F, Suetens P, van Steenberghe D. State-of-the-art on cone beam ct imaging for preoperative planning of implant placement. Clin Oral Investig2006;10(1):1-7.

(6.) Holberg C, Steinhauser S, Geis P, Rudzki-Janson I. Cone-beam computed tomography in orthodontics: Benefits and limitations. J Orofac Orthop 2005;66(6):434-444.

(7.) Honda K, Arai Y, Kashima M, Takano Y. Sawada K, Ejima K, Iwai K. Evaluation of the usefulness of the limited cone-beam CT (3DX) in the assessment of the thickness of the roof of the glenoid fossa of the temporomandibular joint. Dentomaxillofac Radiol 2004;33(6):391-395.

(8.) Misch KA, Yi ES, Sarment DP. Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontal 2006;77(7): 1261-1266.

(9.) Kayipmaz S, Sezgin OS, Saricaoglu ST, Can G An in vitro comparison of diagnostic abilities of conventional radiography, storage phosphor, and cone beam computed tomography to determine occlusal and approximal caries. Eur J Radiol 2011;80(2):478-482.

(10.) Qu X, Li G, Zhang Z, Ma X. Detection accuracy of in vitro approximal caries by cone beam computed tomography images. Eur J Radiol 2011;79(2):e24-27.

(11.) Senel B, Kamburoglu K, Ucok O, Yuksel SP, Ozen T, Avsever H. Diagnostic accuracy of different imaging modalities in detection of proximal caries. Dentomaxillofac Radiol 2010;39(8):501-511.

(12.) Tsuchida R, Araki K, Okano T. Evaluation of a limited cone-beam volumetric imaging system: Comparison with film radiography in detecting incipient proximal caries. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007;104(3):412-416.

(13.) Akdeniz BG, Grondahl HG, Magnusson B. Accuracy of proximal caries depth measurements: Comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res 2006;40(3):202-207.

(14.) American Dental Association Council on Scientific A. The use of cone-beam computed tomography in dentistry: An advisory statement from the american dental association council on scientific affairs. J Am Dent Assoc 2012;143(8):899-902.

(15.) Murat S, Kamburoglu K, Isayev A, Kursun S, Yuksel S. Visibility of artificial buccal recurrent caries under restorations using different radiographic techniques. Oper Dent 2013;38(2): 197-207.

(16.) Farag S AM. Detection of in vitro secondary caries adjacent to restorations using cone-beam computed tomography. Egypt Dent J 2011;57:907-919.

(17.) Jaju PP, Jain M, Singh A, Gupta A. Artefacts in cone beam CT. Open J Stomatol 2013;3:292-297.

(18.) Nabha W, Hong YM, Cho JH, Hwang HS. Assessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography. Korean J Orthod 2014;44(5):229-235.

(19.) Nair MK, Ludlow JB, May KN, Nair UP Johnson MP, Close JM. Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay. Oper Dent 2001;26(3):223-230.

(20.) Charuakkra A, Prapayasatok S, Janhom A, Pongsiriwet S, Verochana K, Mahasantipiya P. Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries. Imaging Sci Dent 2011;41(4):143-150.

(21.) Tohnak S, Mehnert AJ, Mahoney M, Crozier S. Dental ct metal artefact reduction based on sequential substitution. Dentomaxillofac Radiol 2011;40(3):184-190.

(22.) White SC, Pharoah MJ. The evolution and application of dental maxillofacial imaging modalities. Dent ClinNorth Am 2008;52(4):689-705.

(23.) Espelid I, Tveit AB, Erickson RL, Keck SC, Glasspoole EA. Radiopacity of restorations and detection of secondary caries. Dent Mater 1991;7(2):114-117.

(24.) Emadi N, Safi Y, Akbarzadeh Bagheban A, Asgary S. Comparison of CT-number and gray scale value of different dental materials and hard tissues in CT and CBCT Iran Endod J 2014;9(4):283-286.

Elif YILDIZER-KERIS (1), Oguzhan DEMIREL (2), Melih OZDEDE (3), Bulent ALTUNKAYNAK (4), Ilkay PEKER (3)

Corresponding Author:

Elif YILDIZER KERIS

Department of Radiology Canakkale Dentistry Hospital 17000 Kepez- Canakkale/Turkey

Phone: +90 286 216 00 00 (ext:1108)

e-mail: dtelifkaya@gmail.com

(1) Department of Radiology Qanakkale Dentistry Hospital

(2) Department of Dentomaxillofacial Radiology Faculty of Dentistry Medipol University

(3) Department of Dentomaxillofacial Radiology Faculty Dentistry Gazi University

(4) Department of Statistics Faculty Arts and Sciences Gazi University

Received: 23/04/2016

Accepted: 13/06/2016

http://dx.doi.org/10.17096/jiufd.62563
Table 1. Arrangement of tooth sets and block types (O: occlusal, MOD:
mesial-occlusal-distal, DO: distal-occlusal, MO: mesial-occlusal).

Type of blocks  Arrangement of tooth sets

Block type 1    O-MOD-DO-DO
Block type 2    O-MOD-MO-DO
Block type 3    MOD-O-MOD-DO
Block type 4    MOD-O-MOD-MO
Block type 5    O-MOD-O-MO
Block type 7    DO-MOD-O-0

Table 2. The statistical analysis of the areas under the receiver
operating characteristics curves (A values) and the sensitivity and
specificity values of two observers.

Observer  Area  Standard Error  p value   Sensitivity  Specificity

First     .623  .066            .068      .833         .412
Second    .646  .065            .030 (*)  .762         .529

(*) Statistically significant at p<0.05 level.

Table 3. The areas under receiver operating characteristics curves (Az
values) and sensitivity and specificity values for the cavity types (O:
occlusal, MOD: mesial-occlusal-distal, DO: distal-occlusal, MO:
mesial-occlusal, SE: standard error).

Cavity Type  Observer  Area  SE    P     Sensitivity  Specificity

MO/DO        First     .575  .109  .497   .688        .464
             Second    .589  .108  .417   .563        .615
MOD          First     .553  .110  .630   .875        .231
             Second    .560  .110  .584   .813        .308
O            First     .813  .114  .026  1.000        .625
             Second    .875  .097  .008  1.000        .750
COPYRIGHT 2017 AVES
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2017 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:ORIGINAL RESEARCH
Author:Yildizer-Keris, Elif; Demirel, Oguzhan; Ozdede, Melih; Altunkaynak, Bulent; Peker, Ilkay
Publication:Journal of Istanbul University Faculty of Dentistry
Article Type:Report
Date:Jan 1, 2017
Words:2802
Previous Article:LEVELS OF LL-37 ANTIMICROBIAL PEPTIDE IN THE GINGIVAL CREVICULAR FLUID OF YOUNG AND MIDDLE-AGED SUBJECTS WITH OR WITHOUT GINGIVITIS/Gingivitisin Genc...
Next Article:A COMPARATIVE ASSESSMENT OF THE ACCURACIES OF RAYPEX 5, RAYPEX 6, IPEX AND IPEX II ELECTRONIC APEX LOCATORS: AN IN VITRO STUDY/Raypex 5, Raypex 6,...
Topics:

Terms of use | Privacy policy | Copyright © 2020 Farlex, Inc. | Feedback | For webmasters