Comparison of computer aided diagnostic system for wireless capsule endoscopy images using various filters.

INTRODUCTION

An early radio transmitting capsule for the Gastrointestinal (GI) tract examination was released by the Rockefeller Institute of New York in 1957. The total number of cancer related to GI tract in United States is about 149,530. WCE have been used about 12 years for clinical procedure. WCE has become a popular method, which is used to visualize and diagnose the human gastrointestinal tract estimate the location of the capsule without going through the usual intermediate stage of first estimating received signal strength, and then a second stage of estimating the location. The capsule used by WCE have dimension of 2.8 cm long and 0.9 cm in diameter.

In one end of the capsule is housed a minute replaceable battery which is able to supply the electrical power of 15 hours. The other end of the capsule is sealed by a rubber membrane which transmits the body pressure variations to the armature of an inductance coil, and so changes the frequency of the radio signal.

When the capsule is swallowed by a patient and pursues its course through the GI tract, it transmits frequency signals which are varied by the pressure changes in the tract. These signals from the capsule are picked up on a receiver with an antenna held close to the body. The output responses can be displayed on the CRT screen. WCE has advantages, because it is a non-invasive, highly accurate, and portable procedure. The usage of WCE technology is convenient and safe procedure to analyze the affect ulcer bleeding area of the gastrointestinal, and the entire GI tracts is examined without dead zones. Such endoscopy is a realistic alternative to traditional invasive endoscopy and revolutionizes the methods of diagnosing the GI tract diseases.

Dan Wang et al, proposed a novel method for acquiring an Intestinal Direction Vector (IDV) based on a single static wireless endoscopic image. It is based on a lumen detection, which involves Bayer-format down sample, adaptive threshold segmentation, and radial texture detection. The lumen detection method achieves 95.5% precision and 98.1% sensitivity [1].

[FIGURE 1 OMITTED]

Gaffling, S Daum et al, [2] described three-dimensional reconstruction of histological slice sequences offers great benefits in the investigation of different morphologies. The validity of this method is shown on synthetic data, simulated histology data using a CT data set and real histology data. In the case of the simulated histology where the ground truth was known, the mean Target Registration Error (TRE) between the unwrapped and original volume could be reduced to less than 1 pixel.

GuanqunBao et al, [3] presented a hybrid localization technique, which takes advantage of data fusion of multiple sensors inside the WCE, to enhance the positioning accuracy and construct the 3-D trajectory of the WCE. The hybrid algorithm is able to reduce the average localization error from 6.8 cm to <2.3 cm of the existing RF localization systems.

Seung-Kyun Lee et al, [4] described the capability of magnetic resonance imaging (MRI) to produce spatially resolved estimation of tissue electrical properties. It is based on a new theoretical formalism that allows calculation of EPs from the product of transmit and receive radio-frequency field maps. Our results show the feasibility of rapid EP mapping from MRI without B1+ mapping.

Mohammad Pourhomayoun et al, [5] described a wireless capsule endoscopy has become a popular method to visualize and diagnose the human gastrointestinal tract. In this method through extensive Monte Carlo simulations for radio frequency emission signals within the required power and bandwidth range. In wireless capsule is effective and accurate, even in massive multipath conditions. Sehyuk Yim et al, [6] described a new wireless biopsy method where a magnetically actuated untethered soft capsule endoscope carries and releases a large number of thermo-sensitive, untethered micro grippers (g-grippers). The advanced navigation skill of centimeter-scaled untethered magnetic capsule endoscopes with highly parallel, autonomous, sub millimeter scale tissue sampling g-grippers offers a multifunctional strategy for gastrointestinal capsule biopsy.

Jinn-Yi Yeh et al, [7] proposed a capsule endoscopy to detect abnormalities inside regions of the small intestine that are not accessible when using traditional endoscopy techniques. The novel method used for detecting bleeding and ulcers in WCE images. This approach involves using color features to determine the status of the small intestine.

Shu Ting Goh et al, [8] proposed a new method of presurgery gastroscopy and colonoscopy monitoring procedure that allows the patient to freely move inside the medical ward. The DOA is estimated via antenna arrays installed within a medical ward and the IMU is installed on the capsule endoscopy. The number of available antenna arrays on multiplication required by UKF. Image based localization performance is affected by image quality, such as image resolution and distortion.

Holly S. lay et al, [9] proposed an endoscopy and colonoscopy has significantly advanced visualization of the gastrointestinal tract (GIT). To combine the imaging capabilities of endoscopic ultrasound with the full GIT transit of capsule endoscopy. In a hybrid MATLAB simulation was created, incorporating both KLM circuit elements for analog analysis and digitizing and beam forming elements to render a final grey-scale image for imaging quality analysis.

Yuan Gao et al, [10] presented a chipset including an asymmetrical QPSK/OOK transceiver SoC and a JPEG image encoder for wireless capsule endoscopy. The transceiver SoC supports bi-directional telemetry for high data-rate image transmission with QPSK modulation and low data-rate command link with OOK modulation. Jenna L. Gorlewicz, [11] presented the potential benefits of insufflation and the need for an untethered air supply in a capsule endoscope, we now explore the potential of acid/base reactions in producing sufficient gaseous output to meet the visualization and locomotion requirements. The feasibility of enhancing visualization and locomotion of endoscopic capsules through wireless insufflation is explained.

Pawel Turcza et al, [12] presented the design of hardware efficient, low power image processing system for next generation wireless endoscopy. The most significant part of the system is the image compressor. The presented system was prototyped in a single, low-power, 65-nm Field Programmable Gate Arrays (FPGA) chip. Its power consumption is low and comparable to other application-specific-integrated-circuits-based systems, despite FPGA-based implementation.

II. Methodology:

The Flow diagram of developed technique is shown in Fig.2 and the steps involved in this work have explained as follows:

[FIGURE 2 OMITTED]

The input image is gastrointestinal image. This color image can be converted into grayscale image. After converting into grayscale formal histogram equalization is applied and here we taking three filters which are Box, Median and Gaussian filter. By using these filters, we are analysing parameters such as Mean, Standard Deviation, Skewness and Kurtosis.

2.1 Input CE Image:

Capsule Endoscopy (CE) has gradually seen its wide application in hospitals in the last few years because it can view the entire small bowel without invasiveness. However, CE produces too many images each time, thus causing a huge burden to physicians, so it is meaningful to help clinicians if we can employ computerized methods to diagnose.

2.2 RGB Modifications:

RGB image is 24, each channel has 8 bits, for red, green, and blue--in other words, the image is composed of three images (one for each channel), where each image can store discrete pixels with conventional brightness intensities between 0 and 255.

[FIGURE 3 OMITTED]

2.7 Median Filter:

The Median filter is a sliding-window spatial filter, but it replaces the center value in the window with median of all pixel values in the window. In a median filter, a window slides along the image, and the median intensity value of the pixels within the window becomes the output intensity of the pixel being processed. Size of the filter window, by default set to 5 for filter.

RESULTS AND DISCUSSION

The WCE Image has been applied for pre-processing. Fig 4a shows the acquired input image (color image). This color image can be converted into gray scale image value (0-255) as shown in fig.4b. Fig 4c shows the histogram equalization for improving contrast.

[FIGURE 4 OMITTED]

The graph representation of RGB color model using histogram equalization as shown in fig.3. From this graph Red color requires extracting the dominant of an image.

2.3 Gray scale Image:

A gray scale digital image is an image in which the value of each pixel is a single sample that it is carries only intensity information. When converting an RGB image to gray scale, we have to take the RGB value for each pixel and make as output a single value reflecting the brightness of that pixel.

2.4 Histogram Equalization:

Histogram Equalization is a method in image processing of contrast adjustment using the image's histogram. Histogram equalization is a popular technique for improving the appearance of a poor image. HE is one of the common methods used for improving contrast in digital images.

2.5 Box Filter:

Box filtering is basically an average-of-surrounding-pixel kind of image filtering. They have the advantage of being fast to compute, but their adoption has been hampered by the fact that they present serious restrictions to filter construction. The power of box filtering is one can write a general image filter that can do sharpen, emboss, edge-detect, smooth, motion-blur, etcetera. Size of the filter window, by default set to 4 for filter.

2.6 Gaussian Filter:

The Gaussian filtering technique has been used in the removal of speckles. Gaussian smoothing is also used as a pre-processing stage in computer vision algorithms in order to enhance image structures at different scales. Size of the filter window, by default set to 3 for filter.

The obtained results from Aphelion Dev software have been shown in the table 1 and 2.

The statistical parameters such as Mean, Standard Deviation, Skewness and Kurtosis for different filtering techniques are obtained as shown in table.2. The comparative analysis shows that the Gaussian filtering provides better than other techniques.

[FIGURE 3 OMITTED]

[FIGURE 3 OMITTED]

[FIGURE 3 OMITTED]

From this graph representation, it is observed that the Gaussian filter is superior to other filter. It gives better noise reduction when compared to other filters.

Conclusion:

In this paper, the problem associated with the diagnostics of WCE image. Image has been filtered using different methods such as Median, Gaussian and Box. The performances were analyzed using statistical values like Mean, Standard Deviation, Skewness and Kurtosis with the aid of Aphelion Dev software. The comparison of results shows that Gaussian filtering is more suitable for higher noise reduction than other techniques.

REFERENCES

[1.] Dan Wang, Xiang Xie, Guolin Li, Zheng Yin and Zhihua Wang, 2015. "A Lumen Detection-Based Intestinal Direction Vector Acquisition Method for Wireless Endoscopy Systems," IEEE Transactions on Biomedical Engineering, 62(3): 807-819.

[2.] Gaffling, S., V. Daum, S. Steidl, A. Maier, H. Kostler, J. Hornegger, 2015. "A Gauss-Seidel Iteration Scheme for Reference-Free 3-D Histological Image Reconstruction," IEEE Transactions on Medical Imaging, 34(2): 514-530.

[3.] Guanqun Bao, Kaveh Pahlavan, Fellow and Liang Mi, 2015. "Hybrid Localization of Micro robotic Endoscopic Capsule Inside Small Intestine by Data Fusion of Vision and RF Sensors," IEEE Sensors Journal, 15(5): 2669-2678.

[4.] Seung-Kyun Lee; Bulumulla, S., F. Wiesinger, L. Sacolick, Wei Sun, I. Hancu, 2015. "Tissue Electrical Property Mapping From Zero Echo-Time Magnetic Resonance Imaging," IEEE Transactions on Medical Imaging, 34(2): 541-550.

[5.] Mohammad Pourhomayoun, ZhanpengJin, and Mark L. Fowler, 2014. "Accurate Localization of In-Body Medical Implants Based on Spatial Sparsity," IEEE Transactions on Biomedical Engineering, 61(2): 590-597.

[6.] SehyukYim, EvinGultepe, David H. Gracias, and MetinSitti, 2014. "Biopsy using a Magnetic Capsule Endoscope Carrying, Releasing, and Retrieving Untethered Microgrippers," IEEE Transactions on Biomedical Engineering, 61( 2): 513-521.

[7.] Jinn-Yi Yeh1, Tai-Hsi Wu2, Wei-Jun Tsai1, 2014. "Bleeding and Ulcer Detection Using Wireless Capsule Endoscopy Images," Journal of Software Engineering and Applications, 7: 422-432.

[8.] Shu Ting Goh, Seyed A. (Reza) Zekavat, and Kaveh Pahlavan, Fellow, 2014. "DOA-Based Endoscopy Capsule Localization and Orientation Estimation via Unscented Kalman Filter," IEEE Sensors Journal, 14(11): 3819-3829.

[9.] Holly S. Lay, Vipin Seetohul, Ben Cox, Christine E.M. Demore, 2014. "Design and Simulation of a High-Frequency Ring-Shaped Linear Array for Capsule Ultrasound Endoscopy," IEEE International Ultrasonic Symposium Proceedings, pp: 683-686.

[10.] Mohammed A. Al-Rawhani, Member and David R.S. Cumming, 2013. "Design and Implementation of a Wireless Capsule Suitable for Auto fluorescence Intensity Detection in Biological Tissues," IEEE Transactions on Biomedical Engineering, 60(1): 55-62.

[11.] Yuan Gao, San-Jeow Cheng, Chun-HuatHeng, 2013. "An Asymmetrical

[12.] QPSK/OOK Transceiver SoC and 15:1 JPEG Encoder IC for Multifunction Wireless Capsule Endoscopy," IEEE Journal Of Solid-State Circuits, 48(11): 2717-2732.

[13.] Jenna, L., Gorlewicz, Santina Battaglia, Byron F. Smith, 2013. "Wireless Insufflation of the Gastrointestinal Tract," IEEE Transactions on Biomedical Engineering, 60(5): 1225-1233.

[14.] Pawel Turcza and Mariusz Duplagam, 2013. "Hardware-Efficient Low-Power Image Processing System for Wireless Capsule Endoscopy," IEEE Journal of Biomedical and Health Informatics, 17(6): 1046-1056.

(1) P. Elamathi, MIEEE, (2) P. Shanmuga Sundaram, (3) N. Santhiyakumari

(1) PG Scholar (ME- VLSI Design), Dept of ECE, Knowledge Institute of Technology,

(2) Assistant Professor, Dept of ECE, Knowledge Institute of Technology,

(3) Professor and Head Dept of ECE, Knowledge Institute of Technology,

Received February 2016; Accepted 18 April 2016; Available 25 April 2016

Address For Correspondence:

P. Elamathi, MIEEE, PG Scholar (ME- VLSI Design), Dept of ECE, Knowledge Institute of Technology, E-mail: elamathikiot@gmail.com

This work is licensed under the Creative Commons Attribution International License (CC BY).

http://creativecommons.orp/licenses/by/4.0/
Table 1: Histogram Equalization Of Capsule Endoscopy

               Mean      Standard    Skewness   Kurtosis
               RGB       Deviation   RGB        RGB
                         RGB

Histogram      123.072   78.926      -0.1346    -1.128
Equalization   122.373   79.807      -0.1468    -1.139
               123.470   78.267      -0.111     -1.153

Table 2: Comparison Of Various Filters

           Mean     Standard    Skewness   Kurtosis
           RGB      Deviation   RGB        RGB
                    RGB

Median     95.856   59.579      -0.517     -0.976
           95.820   59.624      -0.517     -0.976
           96.051   59.281      -0.510     -0.980
Gaussian   96.336   64.519      -0.532     -0.990
           96.291   63.980      -0.533     -0.990
           96.539   62.908      -0.525     -0.994

Box        95.855   58.9940     -0.520     -0.950
           95.815   59.086      -0.515     -0.951
           96.029   58.695      -0.514     -0.945
COPYRIGHT 2016 American-Eurasian Network for Scientific Information
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2016 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Author:Elamathi, P.; Sundaram, P. Shanmuga; Santhiyakumari, N.
Publication:Advances in Natural and Applied Sciences
Date:May 1, 2016
Words:2365
Previous Article:An efficient proxy re-signature technique for preserving data integrity in cloud.
Next Article:Content based image retrieval system using image classification.
Topics:

Terms of use | Privacy policy | Copyright © 2019 Farlex, Inc. | Feedback | For webmasters