A GRM test that needs a check.

[ILLUSTRATIONS OMITTED]

1. Remove the radio cover and check the part number of the CCA in the A10 slot. If the part number is A3131457, a real failure has happened. Replace the CCA. If the part number is A3137670, reinstall the cover and repeat the test.

2. If the RT displays a FAIL4 code as well as a FAIL6, press and release the "8" key on the keypad until the internal failure codes are displayed. If failure codes "A15-2" or "A10-5" appear, you have a false failure. Press the GO/ENTER key as instructed for a pass condition on the GRM display and soldier on.

3. If other failure codes are displayed, you have an actual failure and the CCA should be replaced.

[ILLUSTRATION OMITTED]

1. Remove the radio cover and check the part number of the CCA in the A10 slot. If the part number is A3131457, a real failure has happened. Replace the CCA. If the part number is A3137670, reinstall the cover and repeat the test.

2. If a failure occurs during the test where the GRM-122 display reads "Read RT display for FAIL6", set the RT FCTN to TST and observe the RT display. If FAIL4 and/or FAIL2 appears in addition to FAIL6, press and release the "8" key on the keypad until the internal failure codes are displayed. If failure codes "A15-2", "A10-5", "A12-1" or "A12-2" appear, you have a false failure. Press the GO/ENTER key as instructed for a pass condition on the GRM display and keep on testing.

3. If other failure codes are displayed, you have an actual failure and the CCA should be replaced.

[ILLUSTRATION OMITTED]

IF YOU HAVE QUESTIONS ABOUT ANY OF THIS, CECOM LCMC EXPERTS ARE STANDING BY AT DSN 992-2082, (732)532-2082, OR DSN 992-9141, (732)532-9141.

YOU CAN REACH THEM BY EMAIL: @us.army.mil AND @us.army.mil.

[ILLUSTRATION OMITTED]
COPYRIGHT 2008 PS Magazine
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2008 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:RT-1523A SINCGARS ...
Publication:PS, the Preventive Maintenance Monthly
Article Type:Brief article
Geographic Code:1USA
Date:May 1, 2008
Words:316
Previous Article:No helmet painting!
Next Article:Save the screens!
Topics:


Related Articles
Metlife acquires ownership of building in Stamford.
Sounding off about SINCGARS.
Seal out moisture.
Some GRM news.
Fire up firefinder with PM.
Operating below E-level.
Princely sum paid for SoHo buildings.
INC test workaround for AM-7239E.

Terms of use | Privacy policy | Copyright © 2019 Farlex, Inc. | Feedback | For webmasters