Printer Friendly

A Comparative Study for Detection of EGFR Mutations in Plasma Cell-Free DNA in Korean Clinical Diagnostic Laboratories.

1. Introduction

Circulating tumor DNA (ctDNA) carries the same molecular alterations as the tumor itself and can be used to select treatment, assess the emergence of drug resistance, and monitor lung cancer patients in routine clinical practice [1]. The fraction of tumor-derived cell-free DNA (cfDNA) in blood plasma varies according to tumor stage, tumor burden, vascularization of the tumor, biological features of the tumor such as apoptotic rate, and the metastatic potential of the cancer cells [2]. Tumor-derived ctDNA often represents a small percentage of the total cfDNA and can be present at allele fractions as low as 0.01% [3]. Therefore, highly sensitive methodologies have been developed to detect low abundance epidermal growth factor receptor (EGFR) mutations, including p.T790M, from cfDNA in non-small cell lung cancer (NSCLC) patients, although the sensitivities and specificities of the methods vary [4, 5].

A sensitive method is needed to detect the p.T790M mutation in relapsed tumors because of tumor heterogeneity [6]. Recently, several in vitro diagnostics (IVD) have been approved by the European Medicines Agency (EMA) and the US Food and Drug Administration (FDA) for detecting EGFR mutations in plasma [7]. To ensure optimal quality molecular testing, clinical laboratories should evaluate the technical performance of ctDNA testing according to the standards from formal accreditation bodies, such as Clinical Laboratory Improvement Amendments (CLIA) and ISO 15189 [8, 9]. External quality assessment (EQA) is a way to standardize interlaboratory results and to monitor and improve testing processes across laboratories [10].

In this study, we designed EQA materials to evaluate the limit of detection (LOD) of the cobas EGFR Mutation Test v2 (Roche Molecular Systems, Inc., Branchburg, NJ, USA) and Oncomine Lung cfDNA Assay (Thermo Fisher Scientific, Waltham, MA, USA). We also implemented a pilot EQA scheme to assess the interlaboratory comparability of plasma EGFR testing results.

2. Materials and Methods

2.1. Preparation of EQA Materials

2.1.1. Pooled Normal Human Plasma (NHP) Preparation. The workflow of the study pro cess is shown in Supplementary Figure S1. Pooled normal human K2 EDTA plasma (NHP) was prepared using residual specimens from healthy individuals and was separated within 4 hours of collection. Negativity for EGFR mutation of 2 mL NHP was confirmed using the cobas EGFR Mutation Test v2 (Roche Molecular Systems, Inc.). cfDNA was extracted from 2mL NHP using the MagMAX[TM] Cell-Free DNA Isolation Kit (Thermo Fisher Scientific) according to the manufacturer's instructions. cfDNA concentration and fragment size distribution were assessed using a 2200 TapeStation Instrument (Agilent Technologies, Santa Clara, CA, USA) with the Agilent D1000 ScreenTape System. Average fragment size was 185 bp, and average cfDNA concentration was 0.106 ng/[micro]L. We calculated that there were 1,162 wild-type copies per 2 mL NHP.

2.1.2. EQA Material to Evaluate Assay Sensitivity. To prepare spiked materials with known mutant allele frequencies and mutant DNA copies, Multiplex I cfDNA Reference Standards (Horizon Discovery, Cambridge, UK) were purchased. This set is composed of wild-type cfDNA with mutant allele frequencies of 5%, 1%, 0.1%, and 0%. For each reference standard, copies per [micro]L of wild-type and mutant DNA were measured using digital droplet PCR and compared with the values provided by the manufacturer (Supplementary Table S1).

Four levels (levels 1 to 4) of spiked NHP (2 mL per sample) were prepared to determine the LOD of the detection assays. Intended mutant allele frequencies were 5%, 2.5%, 1%, and 0.1%, with 4 to 760 mutant copies in a background of about 10,000~16,000 wild-type copies in a spiked NPH samples, depending on the mutation. cfDNA was extracted from 2 mL spiked NHP using MagMAX Cell-Free DNA Isolation Kit (Thermo Fisher Scientific). Concentration and fragment size distribution of cfDNA were assessed using a 2200 TapeStation Instrument (Agilent Technologies). Average fragment size was about 190 bp, and the range of cfDNA was 60.42 ng to 80.18 ng. Details are provided in Supplementary Table S1.

2.1.3. EQA Material to Evaluate Assay Precision. Genomic DNA from cell lines harboring mutations of the EGFR gene including p.T790M (HD258), p.L858R (HD254), and p.E746_A750del (HD251) were purchased from Horizon Discovery. To simulate the size distribution of cfDNA, each genomic DNA was fragmented to about 180~190bp by sonication using a Covaris M220 (330 sec, 0.2% duty, 50 peak incident power, and 200 cycles/burst; Covaris Inc., Woburn, MA, USA) (Supplementary Table S2 and Supplementary Figure S2). Three spiked NHPs (1mL per sample) were prepared to evaluate assay precision. Intended mutant allele frequencies were about 5%, with 1,221 to 1,503 mutant copies in a background of nearly 23,000~30,000 wild-type copies in spiked NPH samples, depending on the mutation. cfDNA was extracted from 1 mL spiked NHP using MagMAX Cell-Free DNA Isolation Kit (Thermo Fisher Scientific). Concentration and fragment size distribution of cfDNA were assessed using a 2200 TapeStation Instrument (Agilent Technologies instructions). Average size was 190 bp, and the cfDNA concentration (ng/mL) was 74.5~80.2. Details are provided in Supplementary Table S2. Spiked NHPs were frozen at < -70[degrees]C until genotyping.

2.2. Validation of EQA Material for LOD Evaluation

2.2.1. cfDNA Extraction from Spiked NHP Samples. cfDNA was extracted from spiked NHP samples using MagMAX Cell-Free DNA Isolation Kit (Thermo Fisher Scientific) for next-generation sequencing and the cobas cfDNA Sample Preparation Kit (Roche Molecular Systems, Inc.) for the cobas EGFR assay. cfDNA concentration and purity were assessed using a NanoDrop 1000 spectrometer (Thermo Scientific, Waltham, MA, USA) and a Qubit 2.0 Fluorometer (Life Technologies, Grand Island, NY, USA) using the Qubit[TM] dsDNA HS Assay Kit. Size and amount of DNA fragments were assessed using a 2200 TapeStation Instrument (Agilent Technologies) with the Agilent D1000 ScreenTape System (Agilent Technologies).

2.2.2. Evaluation of EQA Material Using Next-Generation Sequencing. For next-generation sequencing (NGS), a library was prepared using the Oncomine Lung cfDNA Assay and quantitated using qPCR. Emulsion PCR was performed using the Ion Chef System and Ion AmpliSeq IC 200 Kit (all Thermo Fisher Scientific). Barcoded libraries generated from 20 ng DNA per sample were loaded on an Ion 530 chip and sequenced on the Ion S5 XL System using Ion 520 and Ion 530 Kit-Chef (all Thermo Fisher Scientific). Alignment to the hg19 human reference genome and variant calling were performed using Torrent Suite[TM] software (Thermo Fisher Scientific). Variant annotation was performed using Ion Reporter[TM] Software 5.2 (Thermo Fisher Scientific). Torrent Suite software provides molecular coverage depth as well as read coverage depth at target bases to increase detection sensitivity for low-frequency variants [11, 12]. The manufacturer recommends a median read coverage >25,000X and median molecular coverage >2,500X to detect a variant with an allele frequency of 0.1%. Measured allele frequency (%) was calculated as mutant coverage depth divided by total coverage depth.

2.2.3. Evaluation of LOD Material Using Real-Time PCR. For the cobas EGFR assay, 75 [micro]L DNA from each sample was loaded into three reaction wells (25 [micro]L DNA per well). Amplification and detection were performed using the cobas z 480 analyzer (Roche Molecular Systems, Inc.). Data were interpreted by the cobas z 480 software if positive and negative controls showed valid results. When a mutation was detected, semiquantitative index (SQI) values for each mutation are reported automatically by the software using the observed threshold cycle for the target mutation. The SQI was developed to measure trends in the amount of mutant cfDNA in a patient [13].

The analytical performance of the cobas EGFR assay was additionally evaluated using five NHP samples spiked with different mutant allele frequencies that were made using Multiplex I cfDNA Reference Standards (Horizon Discovery, Cambridge, UK). These test samples had expected mutant allele frequencies of 3.85-5.19%, 1.94-2.65%, 0.72~1.10%, 0.34-0.51%, and 0.05-0.12% (Supplementary Table and Figure 1).

2.3. Distribution of EQA Material, Data Collection, and Analysis. Each laboratory director requested the amount of EQA material needed according to the number of methods planned for plasma EGFR testing. The number of reactions per test method among participating laboratories was 13. The EQA material set comprised four samples (2 mL, levels 1 to 4) with different mutant allele frequencies (5.0%, 2.5%, 1%, and 0.1%) for LOD analysis, and three samples with different EGFR mutations were also provided (1 mL per a reaction, P-1 to P-3).

For each test method, one EQA material set with 2mL of LOD materials (levels 1 to 4) and 3 mL precision materials (P-1 to P-3) were distributed to each participating laboratory. Materials in barcoded K2 EDTA tubes were shipped to laboratories at 4[degrees]C along with a results datasheet to record qualitative results (detected or not detected) and quantitative results (SQI value from the cobas EGFR assay and total/mutant coverage depth from next-generation sequencing) for each mutation. Submitted qualitative results were evaluated as acceptable (positive for expected mutations or negative for unexpected mutations) or unacceptable (negative for expected mutations or positive for unexpected mutations), according to the manufactured and validated target mutations in this study (Table 1 and Supplementary Table S2). LOD level 4 material, which had an expected mutant allele frequency of 0.05-0.12%, was not graded. For the cobas assay, the mean, standard deviation, coefficient of variation (CV), median value, minimum value, and maximum value of data from the peer group and the standard deviation index of the data from the laboratory were provided in the evaluation reports.

2.4. Statistical Analysis. Statistical analysis was performed using SPSS Statistics version 24.0.0 (IBM Corp., Armonk, NY, USA). Correlations between SQI from cobas assay and mutant allele frequency were analyzed using Spearman rank-correlation test. All p values were two-sided, and values less than 0.05 were considered significant.

3. Results

3.1. Validation of EQA Materials. EQA materials for LOD evaluation were validated using the Oncomine Lung cfDNA Assay and cobas EGFR Mutation Test (Table 1). In a deep sequencing run, all four quality control samples were sequenced with high median coverage depth of more than 86,321X. All target bases showed adequate coverage (>500X). There was sufficient coverage at all target mutations to detect variants with allele frequencies of 0.1% (2,236-4,439X). All targeted mutations were called in levels 1-4 materials at similar allele frequencies to what were expected. cobas assay detected not only all target mutations in levels 1-3 materials but also p.L858R (0.12% allele frequency) and p.E746_A750del (exon 19 deletion; 0.10% allele frequency) in level 4 material.

3.2. Analytical Sensitivity of Real-Time PCR. Analytical sensitivity (LOD) of the cobas EGFR assay was assessed using five NHP samples spiked with different amounts of mutated targets (Figure 1 and Supplementary Table S3). Seven of nine cobas assays (77.8%) detected the exon 19 deletion in Test 5 material. All eight measurements of Test 4 material detected the exon 19 deletion. Six (75%), five (62.5%), and seven (87.5%) of eight measurements detected p.L858R, p.T790M, and p.A767_V769dup (exon 20 insertion) mutations in the Test 4 material, respectively. Therefore, the LODs of the cobas EGFR assay were determined to be 5-27 copies/mL for exon 19 deletion (0.1~0.5% allele frequency), 35-70 copies/mL for p.L858R (0.4-0.8% allele frequency), 18-36 copies/mL for p.T790M (0.4-0.8% allele frequency), and 15-31 copies/mL for exon 20 insertion (0.3-0.7% allele frequency). For all mutations, SQI values from the cobas assay exhibited a strong positive correlation with the expected mutant allele frequencies derived from digital droplet PCR measurements (Spearman rank-correlation coefficient, 0.823-0.924; p < 0.0001).

3.3. Pilot EQA Scheme. In November 2016, seven clinical laboratories that perform plasma EGFR molecular testing were recruited for the pilot EQA scheme (Table 2). In April 2017, EQA materials were made and distributed to each laboratory. A month after distributing the EQA materials, all results were emailed from each laboratory to an organizing director. In June 2017, evaluation reports were distributed to participating laboratories. Plasma EGFR testing was performed using an IVD assay and two laboratory-developed tests based on NGS: the cobas EGFR assay (n = 7), the Oncomine Lung cfDNA Assay on the Ion S5 XL (n = 1), and the QIAGEN GeneRead QIAact Actionable Insights Tumor Panel (QIAGEN, Hilden, Germany) on the GeneReader Platform (QIAGEN) (n = 1). There were two unacceptable results for NGS of LOD level 3 material (Tables 3 and 5).

3.4. Interlaboratory Comparability of Real-Time PCR Results. All results obtained using the cobas assay were concordant except for detection of EGFR exon 19 deletion and p.L858R in LOD level 4 material. Among seven laboratories, only six laboratories had a positive result for exon 19 deletion (detection rate 85.7%) and one laboratory had a positive result for p.L858R (detection rate 14.8%) in level 4 material. p.T790M and exon 20 insertion mutations were not detected in LOD level 4 material by any of the laboratories. The precision of SQI is summarized in Table 4. The cobas assay generally showed good reproducibility with a CV between 1.29% and 7.35% for target mutations. However, for p.T790M and exon 20 insertion, the CV for level 3 and/or level 4 materials (13.1% -30.98%) was poorer than for the other mutations.

3.5. Interlaboratory Comparison of Next-Generation Sequencing Results. Mutant allele frequencies were calculated from the submitted depth of coverage data from NGS (Table 5). Results from two laboratories were consistent with the expected mutant allele frequencies calculated from absolute allele frequencies measured using digital droplet PCR. In laboratory F (S5XL + Oncomine Lung cfDNA Assay), all expected mutations were detected in level 3 material. Exon 19 deletion and exon 20 insertion mutations were detected at 0.15% (total read coverage depth of 73,836X) and 0.23% (total read coverage depth of 49,234X) in level 4 material, respectively. However, p.T790M and p.L858R mutations were not detected, despite the fact that total read coverage depth was not lower for these loci than other loci (65,455X for p.T790M and 70,849X for p.L858R). In laboratory C (GeneReader + QIAGEN GeneRead QIAact Actionable Insights Tumor Panel), p.T790M and exon 20 insertion mutations were not detected in level 3 material (unacceptable result). None of the four target mutations were detected in level 4 material.

4. Discussion

In this study, we prepared and validated EQA material for EGFR mutation detection using cfDNA and evaluated the analytical sensitivity of the cobas EGFR assay. According to the package insert, the LOD of the cobas assay using sheared DNA with an average size of 220 bp is less than 0.1% (75 copies/mL for exon 19 deletion, 25copies/mL for the exon 20 insertion, and 100 copies/mL for p.L858R and p.T790M). In the present study, we confirmed the LODs of the cobas assay for each target mutation. The analytical sensitivities of the cobas assay were not identical for the different target mutations, similar to previous reports [14, 15]. In our pilot EQA, the cobas assay showed a higher detection rate and lower imprecision for exon 19 deletion and p.L858R than for p.T790M and exon 20 insertion. Similarly, in laboratory F that used the Oncomine Lung cfDNA Assay, p.T790M and p.L858R were not detected, despite adequate depth of coverage of the target site compared to other loci. This difference in assay performance according to target mutation might be due to the assay design and characteristics of the target regions [14, 15]. This finding is an important issue for detection of p.T790M in patients who show evidence of tumor progression after prior EGFR-tyrosine kinase inhibitor (TKI) therapy. Previous studies reported that it is challenging to detect the p.T790M mutation in patients with acquired resistance to prior EGFR-TKI therapy due to genomic heterogeneity [16, 17]. Therefore, caution is warranted in the setting of tumor relapse, and additional efforts should be made to optimize the experimental conditions to increase the sensitivity of p.T790M detection.

In our pilot EQA, participating laboratories performed one IVD assay (cobas EGFR assay) and two laboratory-developed tests based on NGS. The cobas assay showed reliable and robust test performance in all laboratories. SQI showed a positive correlation with mutant allele frequency derived from digital droplet PCR measurements. This finding is consistent with that of a previous study that evaluated clinical samples with NGS and the cobas assay [13]. Moreover, SQI from the cobas assay was reproducible among laboratories in our pilot EQA. Therefore, SQI could be useful for patient monitoring. About 3 hours of processing time is required for DNA extraction, PCR amplification, and detection in the cobas assay. Thus, this assay can be used for rapid and reliable plasma ctDNA analysis in clinical diagnostic laboratories.

A limitation of this study is the small number of laboratories that participated, especially laboratories performing NGS. It was unclear whether unacceptable responses were due to the performance of specific NGS methods or the laboratory. However, coverage depth results from two laboratories indicate that more read coverage depth is required to detect low-frequency variants in samples. In our validation experiment using the Oncomine Lung cfDNA Assay, all mutations were detected in level 4 material when the coverage depth was more than 100,000X. Our data and previous reports indicate that high coverage depth is essential to improve the detection of low-level targets [18,19].

Another issue related to NGS is assay turn-around time (TAT). TAT for EGFR testing for NSCLC patients is important for drug selection. NGS generally requires more time than IVD, although it differs depending on batch constitution and the platform used. The two laboratories that performed NGS also used an IVD assay. The main advantage of NGS over IVD is scalability for type of mutation and target gene. Using NGS, rare (e.g., the p.C797S resistance mutation [20]) or novel mutations in EGFR, as well as other genes, can be identified [21]. Moreover, advanced NGS technology enables detection of not only point mutation but also gene fusions and amplifications [22, 23].

In the era of companion diagnostics, more mutations will be used as predictive markers to determine patient eligibility for molecular-targeted therapies. As a result, rigorous quality controls to avoid inappropriate patient treatment will become increasingly important in clinical diagnostic laboratories. EQA is critical for quality assurance and continuous improvement of individual laboratory performance [9]. Recently, Haselmann et al. have reported EQA scheme for ctDNA analysis of KRAS and BRAF genotyping, using mutant allele frequency of 0%, 5%, and 10% samples [24]. Digital approaches revealed no error rate, although Sanger sequencing revealed very high error rate around 20%. The authors suggested that method sensitivity correlates with diagnostic accuracy. Another EQA report for blood based EGFR p.T790M testing included pyrosequencing, digital PCR, and several allele-specific PCR platforms, using four levels of spiked materials [25]. Although we used limited number of methods of two NGS and one IVD platform, we suggested more delicate means of EQA workflow tailored to ctDNA testing, using strictly designed low-level materials to assess assay sensitivity and precision in individual laboratories. Larger trial including more genotyping platforms including digital PCR with our sample preparation protocol is worthy of further investigation. In our pilot EQA, we used spiked ctDNA samples, which will facilitate standardization and improvement of ctDNA testing practices in clinical diagnostic laboratories.

https://doi.org/10.1155/2018/7392419

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this paper.

Authors' Contributions

Yoonjung Kim and Saeam Shin contributed equally to this work.

Acknowledgments

This study was supported by a grant of the Korean Health Technology R&D Project, Ministry of Health & Welfare, Republic of Korea (A120030).

Supplementary Materials

Supplementary Figure S1: workflow of the pilot external quality assurance scheme. Supplementary Figure S2: electropherograms of DNA sheared by ultrasonication and run on an Agilent D1000 ScreenTape System. Supplementary Table S1: external quality assurance material for evaluation of limit of detection. Supplementary Table S2: external quality assurance material for evaluation of precision. Supplementary Table S3: preparation material for performance evaluation. (Supplementary Materials)

References

[1] M. A. Molina-Vila, C. Mayo-de-las-Casas, A. Gimenez-Capitan et al., "Liquid biopsy in non-small cell lung cancer," Frontiers in Medicine, vol. 3, p. 69, 2016.

[2] F. Diehl, K. Schmidt, M. A. Choti et al., "Circulating mutant DNA to assess tumor dynamics," Nature Medicine, vol. 14, no. 9, pp. 985-990, 2008.

[3] S. Volik, M. Alcaide, R. D. Morin, and C. Collins, "Cell-free DNA (cfDNA): Clinical significance and utility in cancer shaped by emerging technologies," Molecular Cancer Research, vol. 14, no. 10, pp. 898-908, 2016.

[4] M. Qiu, J. Wang, Y. Xu et al., "Circulating tumor DNA is effective for the detection of EGFR mutation in non-small cell lung cancer: a meta-analysis," Cancer Epidemiology, Biomarkers & Prevention, vol. 24, no. 1, pp. 206-212, 2015.

[5] J. Luo, L. Shen, and D. Zheng, "Diagnostic value of circulating free DNA for the detection of EGFR mutation status in NSCLC: a systematic review and meta-analysis," Scientific Reports, vol. 4, article 6269, 2014.

[6] R. A. Burrell, N. McGranahan, J. Bartek, and C. Swanton, "The causes and consequences of genetic heterogeneity in cancer evolution," Nature, vol. 501, no. 7467, pp. 338-345, 2013.

[7] G. Siravegna, S. Marsoni, S. Siena, and A. Bardelli, "Integrating liquid biopsies into the management of cancer," Nature Reviews Clinical Oncology, vol. 14, no. 9, pp. 531-548, 2017.

[8] J. O. Westgard and S. A. Westgard, "The quality of laboratory testing today: An assessment of a metrics for analytic quality using performance data from proficiency testing surveys and the CLIA criteria for acceptable performance," American Journal of Clinical Pathology, vol. 125, no. 3, pp. 343-354, 2006.

[9] E. Dequeker, S. Ramsden, W. W. Grody, T. T. Stenzel, and D. E. Barton, "Quality control in molecular genetic testing," Nature Reviews Genetics, vol. 2, no. 9, pp. 717-723, 2001.

[10] J. H. van Krieken, A. G. Siebers, and N. Normanno, "European Consensus Conference for external quality assessment in molecular pathology," Annals of Oncology, vol. 24, no. 8, pp. 1958-1963, 2013.

[11] S. Islam, A. Zeisel, S. Joost et al., "Quantitative single-cell RNA-seq with unique molecular identifiers," Nature Methods, vol. 11, no. 2, pp. 163-166, 2014.

[12] M. Shugay, O. V. Britanova, E. M. Merzlyak et al., "Towards error-free profiling of immune repertoires," Nature Methods, vol. 11, no. 6, pp. 653-655, 2014.

[13] A. Marchetti, J. F. Palma, L. Felicioni et al., "Early prediction of response to tyrosine kinase inhibitors by quantification of EGFR mutations in plasma of NSCLC patients," Journal of Thoracic Oncology, vol. 10, no. 10, pp. 1437-1443, 2015.

[14] P. O'Donnell, J. Ferguson, J. Shyu et al., "Analytic performance studies and clinical reproducibility of a real-time PCR assay for the detection of epidermal growth factor receptor gene mutations in formalin-fixed paraffin-embedded tissue specimens of non-small cell lung cancer," BMC Cancer, vol. 13, article no. 210, 2013.

[15] T. Xu, X. Kang, X. You et al., "Cross-platform comparison of four leading technologies for detecting EGFR mutations in circulating tumor DNA from non-small cell lung carcinoma patient plasma," Theranostics, vol. 7, no. 6, pp. 1437-1446, 2017.

[16] K. S. Thress, R. Brant, T. H. Carr et al., "EGFR mutation detection in ctDNA from NSCLC patient plasma: a crossplatform comparison of leading technologies to support the clinical development of AZD9291," Lung Cancer, vol. 90, no. 3, pp. 509-515, 2015.

[17] S. Jenkins, J. C.-H. Yang, S. S. Ramalingam et al., "Plasma ctDNA Analysis for Detection of the EGFR T790M Mutation in Patients with Advanced Non-Small Cell Lung Cancer," Journal of Thoracic Oncology, vol. 12, no. 7, pp. 1061-1070, 2017.

[18] J. Uchida, K. Kato, Y. Kukita et al., "Diagnostic accuracy of noninvasive genotyping of EGFR in lung cancer patients by deep sequencing of plasma cell-free DNA," Clinical Chemistry, vol. 61, no. 9, pp. 1191-1196, 2015.

[19] Y. Kukita, J. Uchida, S. Oba et al., "Quantitative identification of mutant alleles derived from lung cancer in plasma cell-free DNA via anomaly detection using deep sequencing data," PLoS ONE, vol. 8, no. 11, Article ID e81468, 2013.

[20] K. S. Thress, C. P. Paweletz, E. Felip et al., "Acquired EGFR C797S mutation mediates resistance to AZD9291 in non-small cell lung cancer harboring EGFR T790M," Nature Medicine, vol. 21, no. 6, pp. 560-562, 2015.

[21] C. W. Bennett, G. Berchem, Y. J. Kim, and V. El-Khoury, "Cell-free DNA and next-generation sequencing in the service of personalized medicine for lung cancer," Oncotarget, vol. 7, no. 43, pp. 71013-71035, 2016.

[22] C. P. Paweletz, A. G. Sacher, C. K. Raymond et al., "Bias-corrected targeted next-generation sequencing for rapid, multiplexed detection of actionable alterations in cell-free DNA from advanced lung cancer patients," Clinical Cancer Research, vol. 22, no. 4, pp. 915-922, 2016.

[23] S. Cui, W. Zhang, L. Xiong et al., "Use of capture-based next-generation sequencing to detect ALK fusion in plasma cell-free DNA of patients with non-small-cell lung cancer," Oncotarget, vol. 8, no. 2, pp. 2771-2780, 2017.

[24] V. Haselmann, P. Ahmad-Nejad, W. J. Geilenkeuser et al., "Results of the first external quality assessment scheme (EQA) for isolation and analysis of circulating tumour DNA (ctDNA)," Clinical Chemistry and Laboratory Medicine, 2017.

[25] J. Fassunke, M. A. Ihle, D. Lenze et al., "EGFR T790M mutation testing of non-small cell lung cancer tissue and blood samples artificially spiked with circulating cell-free tumor DNA: results of a round robin trial," Virchows Archiv, vol. 471, no. 4, pp. 509-520, 2017.

Yoonjung Kim [ID], (1) Saeam Shin [ID], (2) and Kyung-A Lee [ID] (1)

(1) Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea

(2) Department of Laboratory Medicine, Hallym University College of Medicine, Kangnam Sacred Heart Hospital, Seoul, Republic of Korea

Correspondence should be addressed to Kyung-A Lee; kal1119@yuhs.ac

Received 4 January 2018; Revised 12 March 2018; Accepted 2 April 2018; Published 8 May 2018

Academic Editor: Valli De Re

Caption: FIGURE 1: Analytical sensitivity of the cobas EGFR assay for NHP spiked with five different levels of mutant cfDNA. Copy numbers and frequencies of mutant alleles are provided in Supplementary Table S3. Dots in the figure represent negative measurement (ND) or the SQI value of the positive measurement for (a) p.E746_A750del (exon 19 deletion), (b) p.L858R, (c) p.T790M, and (d) p.A767_V769dup (exon 20 insertion) mutations.
TABLE 1: Validation of external quality assurance material using
Oncomine Lung cfDNA Assay and cobas EGFR Mutation Test.

EQA          EGFR variant      Expected      Number of    Percentage
materials                    mutant allele     mapped     of reads on
                             frequency (%)     reads      target (%)

               P-L858R           4.29
Level 1     p.E746_A750del       5.19         3376397        89.72
               P-T790M           4.01
            p.A767_V769dup       3.85

               P-L858R           2.13
Level 2     p.E746_A750del       2.65         4144029        89.28
               P-T790M           2.05
            p.A767_V769dup       1.94

               P-L858R           0.80
Level 3     p.E746_A750del       1.10         3410157        87.94
               P-T790M           0.81
            p.A767_V769dup       0.72

               P-L858R           0.12
Level 4     p.E746_A750del       0.10         4252130        88.17
               P-T790M           0.11
            p.A767_V769dup       0.05

                                           Oncomine Lung
                                           cfDNA Assay

EQA          EGFR variant    Median base
materials                     coverage     Uniformity of
                                depth      base coverage
                                                (%)

               P-L858R
Level 1     p.E746_A750del      91374           100
               P-T790M
            p.A767_V769dup

               P-L858R
Level 2     p.E746_A750del     108108           100
               P-T790M
            p.A767_V769dup

               P-L858R
Level 3     p.E746_A750del      86321           100
               P-T790M
            p.A767_V769dup

               P-L858R
Level 4     p.E746_A750del     108397           100
               P-T790M
            p.A767_V769dup

                             Oncomine Lung
                             cfDNA Assay
EQA          EGFR variant
materials                      Target base         Molecular
                             coverage at 500X    coverage depth,
                                   (%)            total/mutant

               P-L858R                               2999/53
Level 1     p.E746_A750del          100             4026/118
               P-T790M                              3674/117
            p.A767_V769dup                          3834/122

               P-L858R                               2843/56
Level 2     p.E746_A750del          100              4174/90
               P-T790M                               3942/82
            p.A767_V769dup                           4349/74

               P-L858R                               2236/6
Level 3     p.E746_A750del          100              3533/39
               P-T790M                               3269/31
            p.A767_V769dup                           3655/21

               P-L858R                               2692/2
Level 4     p.E746_A750del          100              3880/4
               P-T790M                               3770/5
            p.A767_V769dup                           3877/4

EQA          EGFR variant     Measured allele    Read coverage
materials                    frequency (%) (a)      depth,
                                                 total/mutant

               P-L858R             1.77           151533/2489
Level 1     p.E746_A750del         2.93           88048/1523
               P-T790M             3.18           97546/3212
            p.A767_V769dup         3.18           58931/2214

               P-L858R             1.97           160148/3418
Level 2     p.E746_A750del         2.16           103525/1216
               P-T790M             2.08           109822/2170
            p.A767_V769dup         1.70           77146/1661

               P-L858R             0.27           122767/477
Level 3     p.E746_A750del         1.10            88048/523
               P-T790M             0.95            92814/927
            p.A767_V769dup         0.57            63023/462

               P-L858R             0.07           159720/152
Level 4     p.E746_A750del         0.10           110976/117
               P-T790M             0.13           117037/149
            p.A767_V769dup         0.10            79321/198

EQA          EGFR variant     Measured allele    SQI from cobas
materials                    frequency (%) (b)   EGFR mutation
                                                      test

               P-L858R             1.64               9.82
Level 1     p.E746_A750del         1.73              15.49
               P-T790M             3.29              11.93
            p.A767_V769dup         3.76               5.06

               P-L858R             2.13               7.49
Level 2     p.E746_A750del         1.17              13.88
               P-T790M             1.98              10.71
            p.A767_V769dup         2.15               3.5

               P-L858R             0.39               6.67
Level 3     p.E746_A750del         0.59               12.9
               P-T790M             1.00               9.28
            p.A767_V769dup         0.73               2.68

               P-L858R             0.10               6.07
Level 4     p.E746_A750del         0.11               9.99
               P-T790M             0.13                ND
            p.A767_V769dup         0.25                ND

(a) Allele frequency (%) = mutant molecular coverage depth/total
molecular coverage depth. (b) Allele frequency (%) = mutant read
coverage depth/total read coverage depth. EQA, external quality
assurance; SQI, semiquantitative index; ND, not detected.

TABLE 2: Plasma EGFR genotyping methods by laboratories participating
in pilot external quality assurance.

                 In vitro           Laboratory-developed tests
                diagnostics

Laboratories
               cobas z 480 +   S5XL + Oncomine    GeneReader + QIAGEN
               cobas  EGFR     Lung cfDNA Assay    GeneRead QIAact
                 Mutation                         Actionable Insights
                  Test v2                             Tumor Panel

A                    O
B                    O
C                    O                                     O
D                    O
E                    O
F                    O                O
G                    O

TABLE 3: Unacceptable response rate in pilot external quality
assurance scheme.

                                           Acceptable response/total
                                                  response (n)

                                               cobas EGFR Mutation
                                              Test (7 laboratories)

Material (a)         EGFR variant

                                            A       B       C      D

Level 1                                    4/4     4/4     4/4    4/4
Level 2        p.L858R; p.E746_ A750del;   4/4     4/4     4/4    4/4
Level 3         p.T790M; p.A767_V769dup    4/4     4/4     4/4    4/4
Level 4                                    -14     -14     -14    -14
P-l                     p.T790M            3/3     3/3     3/3    3/3
P-2                     p.L858R            3/3     3/3     3/3    3/3
P-3                 p.E746_A750del         3/3     3/3     3/3    3/3

                         Acceptable response/total
                               response (n)

                cobas EGFR Mutation            NGS
                Test (7 laboratories)    (2 laboratories)

Material (a)

                 E        F        G        C        F

Level 1         4/4      4/4      4/4      4/4      4/4
Level 2         4/4      4/4      4/4      4/4      4/4
Level 3         4/4      4/4      4/4      2/4      4/4
Level 4         -14      -14      -14      -14      -14
P-l             3/3      3/3      3/3      3/3      3/3
P-2             3/3      3/3      3/3      3/3      3/3
P-3             3/3      3/3      3/3      3/3      3/3

Material (a)   Unacceptable       Unacceptable
               response/total   response rate (%)
                response (n)

Level 1             0/36               0.0
Level 2             0/36               0.0
Level 3             2/36               5.6
Level 4        Not graded (b)          --
P-l                0/26c               0.0
P-2                 0/27               0.0
P-3                 0/27               0.0

(a) Level 1~level 4 materials were prepared for a limit of detection
and P-1~P-3 materials were prepared for precision evaluation. P-1~P-3
materials were split and run on three replications. (b) For cobas
assay, p.L858R mutation was detected in one among seven laboratories
(14.3%), and p.E746_ A750del (exon 19 deletion) mutation was detected
in six among seven laboratories (85.7%). For NGS, exon 19 deletion and
p.A767_V769dup (exon 20 insertion) were detected in laboratory F.
(c) One measurement of P-1 material showed an invalid result in
laboratory C. NGS, next-generation sequencing.

TABLE 4: The performance of interlaboratory comparison samples
using the cobas EGFR Mutation Assay.

                                        p.L858R

Sample          Expected       Copies of      Mean    SD    CV (%)
                 allele       mutant DNA
                frequency   (/[micro]L) (a)
                 (%) (a)

Level 1           4.29            760         9.91   0.61    6.16
Level 2           4.02            380         8.65   0.5     5.76
Level 3            0.8            140         6.93   0.47    6.79
Level 4           0.12            20           --     --      --
Precision          3.0            NP          9.99   0.46    4.61
materials          3.0            NP          9.77   0.53    5.46
(P-1~P-3) (b)      3.0            NP          9.75   0.72    7.35

                           p.E746_A750del (exon 19 deletion)

Sample          Expected       Copies of      Mean     SD    CV (%)
                 allele       mutant DNA
                frequency   (/[micro]L) (a)
                 (%) (a)

Level 1           5.19            600         15.14   0.27    1.79
Level 2           4.72            300         14.24   0.18    1.29
Level 3            1.1            108         12.03   0.56    4.63
Level 4            0.1            10          8.91    0.63    7.11
Precision          3.0            NP          15.2    0.27    1.78
materials          3.0            NP          15.2    0.3     1.95
(P-1~P-3) (b)      3.0            NP          15.22   0.32    2.09

                                       p.T790M

Sample          Expected       Copies of      Mean     SD    CV (%)
                 allele       mutant DNA
                frequency   (/[micro]L) (a)
                 (%) (a)

Level 1           4.01            420         11.28   0.5     4.43
Level 2           3.61            210         10.25   0.59    5.74
Level 3           0.81            72           7.4    1.78   24.08
Level 4           0.11            10           --      --      --
Precision          3.0            NP          11.03   0.31    2.83
materials          3.0            NP          11.22   0.49    4.38
(P-1~P-3) (b)      3.0            NP          11.19   0.59    5.24

                            p.A767_V769dup (exon 20 insertion)

Sample          Expected       Copies of      Mean     SD     CV (%)
                 allele       mutant DNA
                frequency   (/[micro]L) (a)
                 (%) (a)

Level 1           3.85            362         4.52    0.25     5.57
Level 2           3.42            181         3.56    0.47     13.1
Level 3           0.72            62          2.07    0.64    30.98
Level 4           0.05             4           --      --       --
Precision          --             --           --      --       --
materials          --             --           --      --       --
(P-1~P-3) (b)      --             --           --      --       --

(a) Mutant allelic frequency and copies of mutant DNA in materials
were adjusted using next-generation sequencing result from information
provided by the manufacturer of reference standards. (b) Only positive
results from precision materials were summarized in the table. SQI,
semiquantitative index; SD, standard deviation; CV, coefficient of
variation; NP, not provided.

TABLE 5: Comparison of mutant allelic frequency from two
laboratories using different next-generation sequencing platforms.

                                        P-LS5SR

                            Lab F
                Expected                                     Lab C
                 mutant      Molecular         Read           Read
Sample           allele       coverage       coverage       coverage
                frequency      depth,         depth,         depth,
                   (%)      total/mutant   total/mutant   total/mutant
                              (allele        (allele        (allele
                             frequency,     frequency,     frequency,
                                 %)             %)             %)

Level 1           4.29        1970/67       74088/2440      4594/171
                               (3.40)         (3.29)         (3.72)

Level 2           2.13        1755/41       70894/1707      4385/84
                               (2.34)         (2.41)         (1.92)

Level 3           0.80        1912/15       107664/791      4681/52
                               (0.78)         (0.73)         (1.11)

Level 4           0.12         1804/0        70849/0         ND (a)
                                (ND)           (ND)

Precision         3.00        2250/89       97519/3743      4067/148
materials                      (3.96)         (3.84)         (3.64)
(P-1~P-3) (b)
                  3.00        2259/94      124662/5042      6335/344
                               (4.16)         (4.04)         (5.43)

                  3.00        2200/72       87890/2799      4638/139
                               (3.27)         (3.18)         (2.99)

                           p.E746_A750del (exon 19 deletion)

                            Lab F
                Expected                                     Lab C
                 mutant      Molecular         Read           Read
Sample           allele       coverage       coverage       coverage
                frequency      depth,         depth,         depth,
                   (%)      total/mutant   total/mutant   total/mutant
                              (allele        (allele        (allele
                             frequency,     frequency,     frequency,
                                 %)             %)             %)

Level 1           5.19        3360/131      60991/1272      5819/231
                               (3.90)         (2.09)         (3.97)

Level 2           2.13        2855/65       61723/753      10001/130
                               (2.28)         (1.22)         (1.30)

Level 3           1.10        3095/22       94144/378       9416/57
                               (0.71)         (0.40)         (0.61)

Level 4           0.10         3158/3       73836/114        ND (a)
                               (0.09)         (0.15)

Precision         3.00        2306/68       45162/1336      9157/250
materials                      (2.95)         (2.96)         (2.73)
(P-1~P-3) (b)
                  3.00        3326/114     110580/3431      8823/274
                               (3.43)         (3.1)          (3.11)

                  3.00        3462/134      81882/1905     14136/242
                               (3.87)         (2.33)         (1.71)

                                           p.T790M

                            Lab F

                Expected                                     Lab C
                 mutant      Molecular         Read           Read
Sample           allele       coverage       coverage       coverage
                frequency      depth,         depth,         depth,
                   (%)      total/mutant   total/mutant   total/mutant
                              (allele        (allele        (allele
                             frequency,     frequency,     frequency,
                                 %)             %)             %)

Level 1           4.01        3182/124      59366/2276      1717/71
                               (3.90)         (3.83)         (4.14)

Level 2           2.05        2680/51       56596/983       2572/87
                               (1.90)         (1.74)         (3.38)

Level 3           0.81        2902/26       84166/754        ND (a)
                               (0.90)         (0.90)

Level 4           0.11         2980/0        65455/0         ND (a)
                                (ND)           (ND)

Precision         3.00        3132/126      60226/1396      2131/111
materials                      (4.02)         (2.32)         (5.21)
(P-1~P-3) (b)
                  3.00        2980/112      88684/3164      2904/126
                               (3.76)         (3.57)         (4.34)

                  3.00        3380/123      89937/3303      Invalid (c)
                               (3.64)         (3.67)

                           p.A767_V769dup (exon 20 insertion)

                            Lab F

                Expected                                     Lab C
                 mutant      Molecular         Read           Read
Sample           allele       coverage       coverage       coverage
                frequency      depth,         depth,         depth,
                   (%)      total/mutant   total/mutant   total/mutant
                              (allele        (allele        (allele
                             frequency,     frequency,     frequency,
                                 %)             %)             %)

Level 1           3.85        3258/130      38689/1707      1091/30
                               (3.99)         (4.41)         (2.75)

Level 2           1.94        2670/53       37564/541       2341/24
                               (1.99)         (2.37)         (1.03)

Level 3           0.72        3667/21       57591/541        ND (a)
                               (0.57)         (0.94)

Level 4           0.05         3296/3       49234/115        ND (a)
                               (0.09)         (0.23)

Precision
materials
(P-1~P-3) (b)

(a) Coverage depth was not provided by the laboratory. (b) Only
positive results from precision materials were summarized in the table.
(c) One measurement of P-l material showed invalid result using
next-generation sequencing from a laboratory. ND, not detected.
COPYRIGHT 2018 Hindawi Limited
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2018 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Research Article
Author:Kim, Yoonjung; Shin, Saeam; Lee, Kyung-A
Publication:BioMed Research International
Geographic Code:7ISRA
Date:Jan 1, 2018
Words:6344
Previous Article:Dendrimer-Entrapped Gold Nanoparticles as Potential CT Contrast Agents for Localizing Sentinel Lymph Node via Indirect CT Lymphography on Rabbit...
Next Article:Retracted: Analysis of the Influence of Complexity and Entropy of Odorant on Fractal Dynamics and Entropy of EEG Signal.
Topics:

Terms of use | Privacy policy | Copyright © 2021 Farlex, Inc. | Feedback | For webmasters |