Water & oil temperature control: whether your molds run cold or hot, new chillers, TCUs, and cooling towers can save you energy, floor space, and maintenance costs. Some of them even talk to you over the Web.


If you're the sort of manager that can't resist checking up on your plant after you go home for the night, now you can click on your web browser The program that serves as your front end to the Web on the Internet. In order to view a site, you type its address (URL) into the browser's Location field; for example, www.computerlanguage.com, and the home page of that site is downloaded to you.  and read out mold temperatures right there on your PC. If you need such peace of mind, you can get it from "web-enabled" mold temperature control units, or TCUs, that were introduced at the big NPE NPE NullPointerException (Java)
NPE Network Processing Engine
NPE National Policy on Education
NPE National Plastics Exposition
NPE Natural Penis Enlargement
NPE Nutrition Program for the Elderly
 show in Chicago.

Monitoring auxiliary equipment Noun 1. auxiliary equipment - electronic equipment not in direct communication (or under the control of) the central processing unit
off-line equipment
 in cyberspace Coined by William Gibson in his 1984 novel "Neuromancer," it is a futuristic computer network that people use by plugging their minds into it! The term now refers to the Internet or to the online or digital world in general. See Internet and virtual reality. Contrast with meatspace.  may strike some of you as a bit exotic, but most of the new developments in fluid temperature control at NPE were very down to earth. The news was mostly in components that are more compact, more durable, less prone to leaking or corrosion, and able to heat or cool your molds with less energy. More safety features and easier-to-use controls are also common on the new chillers, towers, pump tanks, and TCUs. In many cases, these features come at the same or lower cost than previous models.

New portable chillers

Budzar Industries upgraded its portable chillers with a PLC and touchscreen that displays complete operating conditions, diagnostics, and a troubleshooting guide when needed. The controls also feature complete communications, a run-hour meter, and remote online servicing capability. They have scroll compressors and nonferrous pumps, reservoirs, and piping. Air-cooled models run 0.75 to 20 tons, water-cooled are 3 to 20 tons.

Conair introduced the Thermolator line of portable chillers that are said to be "aggressively priced" but net strippeddown in terms of features. They have brazed-plate evaporators, scroll compressors on larger units, and reciprocating compressors on smaller ones. There is also a three-year warranty and plenty of options. Among them are two levels of control: A simple microprocessor type with LED is standard. Above that are a full-featured PLC with LCD screen and an option for a remote PLC.

In this series, PCA (tool, programming) PCA - A dynamic analyser from DEC giving information on run-time performance and code use.  air-cooled models of l.5 to 30 tens have fin-mid-tube condensers. PCW PCW PC World (computer magazine; PC World Communications, Inc.)
PCW Post Consumer Waste
PCW Polichlorek Winylu (Polish: Polyvinyl chloride)
PCW Personal Care Worker
 water-cooled versions of 1.5 to 30 tons have tube-in-tube condensers on smaller units and brazed-plate condensers on the larger ones (shell-and-tube optional).

L-R L-R Left to Right
L-R Lenoir-Rhyne College (Hickory, North Carolina) 
 Systems brought out a complete line of cooling products--its first--built by an unnamed U.S. supplier. The line includes portable air-cooled models of 0.25 to 30 tons and water-cooled units of 2 to 40 tons. They have centrifugal pumps (0.24 to 10 hp), scroll or reciprocating compressors, brazed-plate evaporators, nonferrous reservoirs, stainless-steel cabinets, and microprocessor controls with SPI (1) (Stateful Packet Inspection) See stateful inspection.

(2) (Service Provider Interface) The programming interface for developing Windows drivers under WOSA.
 communications protocol Hardware and software standards that govern data transmission between computers. The term "protocol" is very generic and is used for hundreds of different communications methods. A protocol may define the packet structure of the data transmitted or the control commands that manage the .

Also getting into chillers for the first time is Regloplas, which will roll out portable units of up to 80 tons at the start of 2004.

New from Thermal Care is the AccuChiller EQ series of air-cooled portable models (0.5 to 3 tons) with microprocessor control. They are said to be more compact than previous models and to have easier access for maintenance.

Wittmann's new portable chillers have been completely redesigned since its acquisition of Capitol Temptrol last year. These air- and water-cooled models of 2 to 15 tons now have all-stainless cabinets, nonferrous plumbing, brazed-plate heat exchangers, and scroll compressors.

Central chillers evolve

AEC's new central chillers employ rotational compressors, which are said to be more reliable and efficient than reciprocating (discus) compressors. The latter have up to twice as many moving parts Moving parts are the components of a device that undergo continuous or frequent motion, most commonly rotation. "Parts" only include the mechanical components which does not include fuel, or any other gas or liquid. , which cause more noise and vibration. The R series comprises two groups: RC models of 30 to 100 tons have scroll compressors and stainless brazed-plate evaporators. RS units of 60 to 195 tons use screw compressors (said to be more efficient) and shell-and-tube evaporators in models over 100 tons; smaller units in this group have the more compact stainless brazed-plate evaporators.

While The RC models use conventional R-22 refrigerant re·frig·er·ant
adj.
1. Cooling or freezing; refrigerating.

2. Reducing fever.

n.
1. A substance, such as air, ammonia, water, or carbon dioxide, used to provide cooling either as the working substance of
, RS models use newer R-134a non-CFC refrigerant, which is less ozone-depleting and also up to 12% more energy efficient, according to according to
prep.
1. As stated or indicated by; on the authority of: according to historians.

2. In keeping with: according to instructions.

3.
 AEC AEC US Atomic Energy Commission

Noun 1. AEC - a former executive agency (from 1946 to 1974) that was responsible for research into atomic energy and its peacetime uses in the United States
Atomic Energy Commission
. While smaller chillers have been using R134a, AEC believes its RS models are the first large industrial screw-type units to use this refrigerant.

Two levels of Allen-Bradley touchscreen controls are offered for the R Series--a basic monochrome version to control up to four compressors in one or two circuits, and a more advanced color model See color space.

color model - colour model
 that can also control cooling-tower fans and pumps, as well as chemical water-treatment pumps.

Sister company Sterlco introduced a similar S Series of central chillers, except that Sterlco uses PLCs from Mitsubishi instead of Allen-Bradley.

Berg Chilling Systems has a new line of large packaged chillers and pumps from 30 to 200 tons. They boast smaller footprints and easier servicing since they are built all on one level. They also have a new, simple-to-use touchscreen controller.

Budzar's new WM (water-cooled) and AMO AMO - America's Multimedia Online  (outdoor air-cooled) central chillers have a PLC and touchscreen that displays complete operating conditions, diagnostics, and a troubleshooting guide. Remote diagnostics Vehicle Diagnostics
Vehicle diagnostics enables a mechanic to diagnose the exact mechanical condition of the vehicle and its systems and components. Remote Diagnostics enables to perform such diagnosis without requiring the vehicle to physically be present for checkup.
 can be performed via modem, Software constantly adjusts the chiller chill·er  
n.
1. One that chills.

2. A frightening story, especially one involving violence, evil, or the supernatural; a thriller.


chiller
Noun

1.
 to the operating and ambient conditions, yielding operating cost/ton lower than with other chillers, the company says. Both series range from 20 to 400 tons. The AMO Series is available in a split system or with an optional on-board pump-tank system and reservoir that greatly reduce installation costs.

L-R Systems' new cooling line includes central chillers of 20 to 200 tons with one, two, or three zones plus air or water cooling Water cooling is a method of heat removal from components. As opposed to air cooling, water is used as the heat transmitter. Water cooling is commonly used for cooling internal combustion engines in automobiles and electrical generators.  and integral pump tank with two pumps (three optional). They can have scroll, screw, or discus compressors and brazed-plate or shell-and-tube evaporators. Outputs are 60 to 600 gpm. Microprocessor controls are standard.

Mokon, which previously specialized in smaller portable chillers, unveiled its first central models at the show. These air- and water-cooled Iceman Iceman

Body of a man found sealed in a glacier in the Tirolean Ötztal Alps in 1991 and dated to 3300 BC. It has revealed significant details of everyday life during the Neolithic Period.
 models of 30 to 80 tons have single or multiple circuits, scroll or discus compressors, brazed-plate evaporators, and microprocessor or Allen-Bradley PLC control. Standard features are all-stainless construction and electronic hot-gas bypass--said to be more accurate than mechanical bypass.

Regloplas's new chiller offerings, to debut the first of the year, will include central models of up to 150 tons.

Thermal Care has upgraded its TX Series of central chillers, which have screw compressors and range up to 440 tons. The firm now offers compressors of 70 to 220 hp, whereas the previous maximum was 60 hp. The upgrade permits use of one large compressor in place of two small ones to reduce both cost and machine footprint. (On the other hand, dual compressors provide redundancy and better efficiency at low loads.) Also new are electronic expansion valves, said to raise energy efficiency at reduced head pressures.

Within the past year, Thermal Care also came out with a color touchscreen PLC control for its central chillers. It displays the entire plant cooling system cooling system: see air conditioning; internal-combustion engine; refrigeration.
cooling system

Apparatus used to keep the temperature of a structure or device from exceeding limits imposed by needs of safety and efficiency.
 and the run-time hours on all equipment. You just touch an icon to bring up all the details for any piece of equipment in the system.

In addition, Thermal Care's TS Series of central chillers up to 100 tons have a new low-cost Allen-Bradley PLC and PanelView display.

Wittmann redesigned its central chillers since its Capitol Temptrol acquisition. Models up to 300 tons can have screw, scroll, or discus compressors. In what may be a unique option, these multi-circuit systems can have a so-called '"free cooling" coil packaged with the chiller. This allows the system to switch automatically from the chiller to ambient cooling whenever the outdoor temperature drops to 40 F or below.

Pump tanks

Several firms also brought out new pump tanks for central chilling systems. Mokon, for example, introduced its first line of such products, in standard sizes from 250 to 3500 gal and in stainless or carbon steel.

Thermal Care added an intermediate size--1100 gal--to its line of fiberglass/plastic pump tanks, which go up to 2200 gal. The line also has a new compact (1/16 DIN) control.

Wittmann introduced an unusual pump-tank design with four pumps for the same price as the usual three. Standard systems have one recirculation Noun 1. recirculation - circulation again
circulation - the spread or transmission of something (as news or money) to a wider group or area
 pump, one process pump, and often one backup pump that can substitute for either of the first two. Instead Wittmann's new setup has two pairs of Armstrong dual-arm pumps--one pair for recirculation and one for the process. One member of each pair is a back-up that comes on automatically if the first one fails--or the two pumps can be used in an alternating schedule to minimize wear and extend their life. These Armstrong pumps have integral valves, which reduce cost. Also, their vertical mounting eliminates the need for bearings, so they run quieter, Wittmann says. Oversized o·ver·size  
n.
1. A size that is larger than usual.

2. An oversize article or object.

adj. o·ver·size also o·ver·sized
Larger in size than usual or necessary.
 fittings are said to provide 60% more flow than in typical systems.

Pump tanks are also part of the new cooling-system offerings from L-R Systems. They range from 250 to 5000 gal with pumps of 2 to 60 hp.

Smarter cooling towers

New controls for cooling towers and pump-tank stations were highlighted by Advantage Engineering. The new CheckMate checkmate

end of game in chess: folk-etymology of Shah-mat, ‘the Shah is dead.’ [Br. Folklore: Espy, 217]

See : End
 Series is said to be less expensive and simpler to use than PLCs and can control up to 12 motors. Two versions are offered: The LE model has an LCD display, while the HE version has a touchscreen. The LE displays water temperatures to and from the process and allows you to change thermostat settings without opening the cabinet. The HE can display time/temperature graphs and the fan's run-time hours. Options include display of water quality--pH and dissolved solids--as well as wet-bulb temperature Wet-bulb temperature - there are several meanings of this term:
  1. The temperature read from a wet bulb thermometer,
  2. Isobaric wet-bulb temperature: the temperature an air parcel would have if cooled adiabatically to saturation at constant pressure by evaporation of water
.

CheckMate systems also have the company's new Top Operator pump/fan control. It combines three traditional components in one module--on/off or on/off/auto switch, running light, and overload light. Top Operator can also work with any PLC system.

Marley Cooling Towers introduced two new product lines. Primus cross-flow UniBasin factory-assembled towers boast a simpler design, lower cost, and faster delivery (two weeks). They have an integrated fan cylinder and distribution basin on top and a one-piece collection basin on the bottom--both of rotomolded polyethylene. Primus systems are said to be lighter and quieter than most and have no valves.

Also new are Modulus counterflow modular towers. These stainless-steel units have a simple design that reportedly allows them to be erected in one-third the time of conventional "stick-built" towers.

L-R Systems now offers cooling towers of 45 to 450 tons with nonferrous construction, structural base, and gasketed, easily removed inspection covers. They can have single or multiple cells.

Water treating/filtering

New from Miller-Leaman is the automatic Turbo-Disc water filter. This fully automatic unit is offered for both side-stream and full-flow applications. It has stainless-steel manifolds and comes with or without a booster pump. It reportedly uses a fraction of the flushing water used by traditional sand filters.

Automatic Filters now makes its Tekleen water filter in stainless steel stainless steel: see steel.
stainless steel

Any of a family of alloy steels usually containing 10–30% chromium. The presence of chromium, together with low carbon content, gives remarkable resistance to corrosion and heat.
 at the same price as before.

Both AEC and Sterling have new arrangements to offer the TowerKleen chemical-free water-treatment system. AEC calls it the TK Series, and Sterling dubs it the STK Series.

L-R Systems now offers water filters with 1-psi pressure drop as well as automatic water-treatment systems, heat exchangers, and centrifugal separators.

Hot-water TCUs on the web

Wittmann claims to have introduced the industry's first "web-enabled" TCUs. They have embedded web servers Web server software embedded within a hardware device such as a print server. It is widely used in a myriad of devices, because it allows access to the software via any Web browser, typically for configuring the device or obtaining reports. See ETI and Web server.  in the controls that give users access to setpoints, maintenance documents, operating instructions, and troubleshooting assistance from any location. The web servers also have interfaces to Wittmann's Wittlink software, which "allows setpoints and operating data to be communicated to and from an entire cell of Wittmann auxiliaries.

Wittmann also brought out two new TCUs. The Tempro Direct 250 is a microprocessor-controlled unit with direct-injection cooling. It comes with turbine pumps of 1 to 3 hp that are said to generate higher pressure (50 to 90 psi) and higher flow (6 to 8 gpm) than typical units with centrifugal pumps. Heating capacity is 9 or 12 kw. Mold evacuation or purging is optional. Price of the standard 1-hp, 9-kw unit starts at $2250. It measures just 10.2 in. wide x 19.5 in. long x 26.2 in. high.

Wittmann's other new TCU (Transmission Control Unit) A communications control unit controlled by the computer that does not execute internally stored programs. Contrast with front end processor, which executes its own instructions.  is the Tempro Primus C, a more basic, inexpensive model that starts at $1395. This 0.75-hp, 9-kw unit can be supplied with either vacuum mold purge or negative-pressure capability. Temperature capability is 200 F (vs. 250 F for the Tempro Direct 250). It has microprocessor control, nonferrous wetted surfaces, and a high-pressure pump capable of 15 gpm at 55 psi. The submerged sealless pump eliminates leakage from mechanical pump seals.

Both AEC and sister company Sterlco introduced water-temperature controllers described as low-priced but amply equipped. AEC's ECU Series and Sterlco's SEU SEU Shoot 'Em Up (game category)
SEU St. Edward's University (Austin, Texas)
SEU Southeast University
SEU Single Event Upset
 Series have centrifugal pumps from 0.75 to 7.5 hp, flow rates up to 100 gpm, and 9-kw Incoloy immersion heaters (12 kw optional). They also have up to 0.75-in. solenoid valves, and microprocessor control with process and setpoint LED readouts. Numerous safety features include automatic vent sequencing, independent high-temperature safety thermostats, adjustable low-level pressure switches, and 150-psi relief valves. Starting price starting price n (COMM) → precio inicial

starting price nprix initial

starting price start n (at auction
 for a 0.75-hp unit is $1395--$600 less than a high-end model. Delivery time is one week. Sources at these companies hint that another sister company, Economizer e·con·o·mize  
v. e·con·o·mized, e·con·o·miz·ing, e·con·o·miz·es

v.intr.
1. To practice economy, as by avoiding waste or reducing expenditures.

2.
 USA, will soon come out with even lower-priced TCU models.

Sterling also introduced a new 6kw SEA hot-water TCU designed for European and Asian molders that prefer very small units that can slide under the press. They are used by transplant operations here that process silicone and other thermoset A polymer-based liquid or powder that becomes solid when heated, placed under pressure, treated with a chemical or via radiation. The curing process creates a chemical bond that, unlike a thermoplastic, prevents the material from being remelted. See thermoplastic.  rubbers. Unlike the majority of U.S. molders, transplant and overseas processors also prefer dosed-loop operation (i.e., using heat exchangers to interface with a separate cooling-tower circuit instead of direct injection of cooling water). The SEA unit has a new high-efficiency pump with no mechanical seal to be damaged by hard water. Ahot-oil version for up to 300 F is also available.

More economical "value-priced" Thermolator hot-water TCUs are new from Con-air. With pumps from 0.75 to 7.5 hp and heaters from 9 to 48 kw, the units start at $1550, down from $1695 for past models. In addition to a three-year warranty, they feature two-piece cast construction, silicon carbide silicon carbide, chemical compound, SiC, that forms extremely hard, dark, iridescent crystals that are insoluble in water and other common solvents. Widely used as an abrasive, it is marketed under such familiar trade names as Carborundum and Crystolon.  pump seals, Incoloy heaters, to/from-process pressure gauges, and simple microprocessor controls with LED readout (1) A small display device that typically shows only a few digits or a couple of lines of data.

(2) Any display screen or panel.
. (Higher level control options are available,) Direct-injection cooling is standard, though closed-circuit and isolated-circuit cooling are available, as are dual-zone models.

Budzar has redesigned its portable "mini" hot-water units with stainless-steel piping and pumps and higher-temperature (300 F), silicon-carbide seals. Direct-injection or closed-loop cooling are offered. Closed-loop models have stainless brazed-plate heat exchangers. Flow rates can be 20 to 100 gpm at 30 psi (50 psi optional).

Matsui has also upgraded its hot-water units in the new Plas-Aid GMC GMC

See: Guaranteed Mortgage Certificate
 line that features lower prices but increased pump power, stainless-steel components, and simpler microprocessor controls. Nine models cover three temperature ranges (hot-oil models are also available). Pumps are 0.4, 0.8, and 1.3 hp. Water manifolds, ball valves with threaded couplers, and solid-state relays are standard.

Mokon's line of Duratherm hot-water TCUs has been expanded from the former range of 0.75 to 3 hp up to 10 hp without increasing the cabinet size. Flow rates are now up to 120 gpm, and maximum heating capacity has been raised to 96 kw. Single- and dual-zone models offer temperatures up to 300 F. All have noncorrosive construction.

Mokon also brought out its first positive/negative-pressure units, which can temporarily stop leaks by pulling rather than pushing water through the mold. These Duratherm NPS NPS National Park Service
NPS Naval Postgraduate School
NPS Net Promoter Score (customer management)
NPS Non-Point Source pollution
NPS Native Plant Society
NPS Norfolk Public Schools (Virginia) 
 units range up to 5 hp and handle temperatures to 180 F.

A small combination chiller and hot-water controller was introduced by Opti-Temp. Its "Cheater" (chiller/ heater) provides water temperatures from 30 to 190 F to machines processing under 100 lb/hr. It's aimed at high-end applications that require very precise temperature control within [+ or -]0.2[degrees]F. This stand-alone, close-loop system does not require an outside water source.

A pressurized pres·sur·ize  
tr.v. pres·sur·ized, pres·sur·iz·ing, pres·sur·iz·es
1. To maintain normal air pressure in (an enclosure, as an aircraft or submarine).

2.
 hot-water unit for 250 F and up was unveiled by Regloplas. Suited to large presses, model P120XL has heating capacity to 40 kw and water-cooling capacity to 125 kw, along with automatic water refill, negative-pressure "leak-stop" mode, and automatic suction to purge lines for mold changes.

In the past year, several firms brought out multi-zone hot-water TCUs aimed at CD and DVD DVD: see digital versatile disc.
DVD
 in full digital video disc or digital versatile disc

Type of optical disc. The DVD represents the second generation of compact-disc (CD) technology.
 molding. Among these were units of four or six zones from AEC and Sterlco .Another comes from Thermal Care. Its CRA See Community Reinvestment Act.  Series is said to control within [+ or -] 0.2 to 0.5[degrees]F.

L-R Systems now offers hot-water units of 0.75 to 7.5 hp mad 6 to 48 kw for temperatures up to 250 F. They include modulating cooling valves, stainless-steel cabinets, continuous display of set-point and to-process temperatures, and SPI communications protocol.

Oil TCUs go hotter Budzar redesigned and upgraded its portable Silver Series hot-oil units, which now operate at up to 600 F vs. 450 F previously and provide flow rates up to 50 gpm (from 30 gpm before). Heating capacity is up to 48 kw. Other new features include welded pipe construction to eliminate leaks, an ultra-low-watt-density heater to prevent "coking," and a reversible pump for mold evacuation/purging.

The latest hot-oil unit from Regloplas is model 300S for high-temperature engineering resins. This 6-kw unit heats up to 570 F and pumps 14.3 gpm at 73 psi. It offers a small footprint, magnetically coupled pump for zero leakage, negative-pressure leak-stop mode, and automatic suction for mold purging. Its microprocessor control provides simultaneous readout of set and actual temperatures. This is the smallest unit in a line that previously went from 12 to 36 kw.

Hot-oil units newly available from L-R Systems heat up to 500 F with 12 to 48 kw. They have centrifugal pumps of 1 to 7.5 hp, stainless-steel cabinets, low-watt-density heaters, continuous set and actual temperature display, and SPI communications protocol.

Other news in hot-oil systems includes the following:

* Burger & Brown launched the Smartflow hat-oil flowmeter See flow meter.  for use at up to 550 F. This positive-displacement device is line-mounted to give visual indication of flow rates from 5 to 40 gpm on an analog gauge.

* Mokon's new ClearFlo oil filtration system removes particles down to 10 microns without disrupting system operation. The companion ClearFlo Plus system filters particles down to 0.1 micron and also removes water:

* Paratherm Corp. showed its new SC "system cleaner" fluid, which removes sludge and carbon deposits. Run it through your system overnight, and no manual labor should be necessary.

NEED TO KNOW MORE?

Advantage Engineering, Inc., Greenwood, Ind. (317) 887-0729.www.advantageengineering.com

AEC Inc., Wood Dale. III. (630) 595-1060 www.aecinternet.com

Automatic Filters. Inc., Los Angeles Los Angeles (lôs ăn`jələs, lŏs, ăn`jəlēz'), city (1990 pop. 3,485,398), seat of Los Angeles co., S Calif.; inc. 1850.  (800) 336-1942, www.tekleen.com

Berg Chilling Systems Inc., Toronto (416) 755-2221. www.berg-group.com

Budzar Industries, Inc., Willoughby, Ohio Willoughby is a city in Lake County, Ohio, United States. It is a suburb of Cleveland, Ohio. The population was 22,621 at the 2000 census. Willoughby is served by a branch of the Willoughby-Eastlake Public Library.  (440) 918-0505. www.budzar.com

Burger & Brown Engineering, Inc., Olathe, Kan. (800) 764-3518 www.smartflow-usa.com

Conair, Pittsburgh (412) 312-6000. www.conairnet.com

Economizer USA, South Attleboro, Mass. (508) 399-3019

L-R Systems, New Lenox, III. (8t5) 485-2155. www.I-rsystems.com

Marley Cooling Technologies, Overland Park Overland Park, city (1990 pop. 111,790), Johnson co., NE Kans., a residential suburb of Kansas City; inc. 1960. There is printing and publishing, and the manufacture of apparel, aircraft parts, cement, prepared foods, salt, chemicals, marine accessories, and signs. , Kan. (800) 462-7539, www.marleyct.com

Matsui America, Inc., Elk Grove Village Elk Grove Village, village (1990 pop. 33,429), Cook and Du Page counties, NE Ill., a suburb of Chicago; inc. 1956. With a population of c.100 at the time of its establishment on open farmland, the village has grown dramatically and steadily, largely because of its , III. (847) 290-9680, www.matsuiamerica.com

Miller-Leaman, Inc., Daytona Beach Daytona Beach (dātō`nə), city (1990 pop. 61,921), Volusia co., NE Fla., on the Atlantic coast and Halifax River (a lagoon); inc. 1876. Center of a rapidly urbanizing area, in a region settled by Spanish Franciscans in the 17th cent. , Fla. (800) 881-0320

Mokon, Buffalo, N.Y. (716) 876-9951, www.mokon.com

Opti Temp Inc., Traverse City Traverse City, city (1990 pop. 15,155), seat of Grand Traverse co., N Mich., at the head of the West Arm of Grand Traverse Bay, in a resort and cherry-growing region; inc. 1881. , Mich. (231) 946-2931, www.optitemp.com

Paratherm Corp., Conshohocken, Pa. (800) 222-3611, www.paratherm.com

Regloplas Corp., St. Joseph, Mich. (888) 799-4110, www.regloplasusa.com

Sterlco Div. of Sterling, Inc., Milwaukee (414) 354-0970, www.sterlco.com

Thermal Care, Inc., Niles, III. (888) 828-7387, www.thermalcare.com

Wittmann, Inc., Torrington, Conn. (880) 496-9603, www.wittmann-ct.com
COPYRIGHT 2003 Gardner Publications, Inc.
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2003, Gale Group. All rights reserved. Gale Group is a Thomson Corporation Company.

 Reader Opinion

Title:

Comment:



 

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:NPE News Wrap-Up
Author:Naitove, Matthew H.
Publication:Plastics Technology
Geographic Code:1USA
Date:Dec 1, 2003
Words:3239
Previous Article:Sequential valve gating: ultimate control for the toughest molding jobs.(Cover Story)
Next Article:Polyurethanes: regulatory cost pressures spur foam formulators.
Topics:



Related Articles
Liquid Temperature-Control Equipment.
LIQUID TEMPERATURE-CONTROL EQUIPMENT.(Brief Article)
Liquid temperature-control equipment. (Product Lines Reviewed).
Liquid temperature-control equipment.(Product Lines Reviewed)
Liquid temperature-control equipment.(Product Lines Reviewed)
Liquid temperature-control equipment.(PRODUCT LINES REVIEWED)
Heating & cooling.(What to See at NPE 2006)
'Fluid cooler' offers alternative to cooling towers or central chillers.(Close-Up: PROCESS COOLING)
Liquid temperature-control equipment.(PRODUCT LINES REVIEWED)
Fluid temperature control: saving on energy & maintenance.(NPE 2006 News Wrap-Up)

Terms of use | Copyright © 2009 Farlex, Inc. | Feedback | For webmasters | Submit articles