Printer Friendly

United Kingdom - INTERCOMPARISON OF LOW CYCLE FATIGUE MEASUREMENTS.

Project Funding Project Funding reflects the overall financial analysis and entails the analysis that is needed in order to get the financial means approved and funds made available to be able to perform the discipline of project management. :344600 EURO (USD USD

In currencies, this is the abbreviation for the U.S. Dollar.

Notes:
The currency market, also known as the Foreign Exchange market, is the largest financial market in the world, with a daily average volume of over US $1 trillion.
 448,490.61)

Description:

General information: Structures and parts are normally designed so that their in-service deformation is solely elastic and at such a level as to not induce fatigue failure. However, for advanced applications such as gas turbines, electric power plants and nuclear reactors, it becomes impossible to avoid repeatedly stressing parts beyond their elastic limit during critical phases of operation such as start up and shut down. As a result fatigue lives for materials are reduced from many millions of cycles in the elastic range to thousands in the plastic range.

Low cycle fatigue Low-Cycle Fatigue is cycle conditions that result in

1.) fatigue (material) in less than 105 cycles (some sources say 103cycles).

2.) macroplastic deformation in every cycle.
 tests which should simulate in-service plastic stressing are not standardized. The purpose of the project is to provide a clear understanding of the effects of test parameters in order that the standardization process may proceed upon a sound basis.

STATUS -

Four materials, 2 strain softening, 1 strain hardening and 1 strain stable were purchased and, following homogeneity testing, were distributed to the participants. Each of these made measurements in accordance with a well defined set of guidelines using their normal design of specimen and types of extensometers plus a range of failure criteria. The results of the intercomparison show that the differences between laboratories are frequently greater than a factor of 10 whilst the variations within any given laboratory are significantly less. Although the scatter depends of a variety of parameters it appears that the use of ridged specimens leads to much reduced lifetime. Excluding the results of such specimens, the scatter remains unacceptable for reasons which were not resolved by the intercomparison. However, subsequent research suggests that even small amounts of specimen misalignment mis·a·ligned  
adj.
Incorrectly aligned.



misa·lignment n.
 could account for it. Experiments are therefore being undertaken to confirm this.

country :United Kingdom

2012 Al Bawaba (Albawaba.com)

Provided by Syndigate.info an Albawaba.com company
COPYRIGHT 2013 Al Bawaba (Middle East) Ltd.
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2013 Gale, Cengage Learning. All rights reserved.

 Reader Opinion

Title:

Comment:



 

Article Details
Printer friendly Cite/link Email Feedback
Publication:Mena Report
Date:Jan 4, 2013
Words:303
Previous Article:Belgium : Coordination of a Centralized Facility for Clinical Trials in Oncology.
Next Article:United Kingdom - PROSTATIC ACID PHOSPHATASE.
Topics:

Terms of use | Copyright © 2014 Farlex, Inc. | Feedback | For webmasters