The hex: New regulations for hexavalent chromium go into effect in late November.


For years, hexavalent chromium compounds have been regulated in many different ways.

For the construction (29 CFR CFR

See: Cost and Freight
 1926) and shipyard (29 CFR 1915) industries, the Occupational Safety and Health Administration Occupational Safety and Health Administration (OSHA), U.S. agency established (1970) in the Dept. of Labor (see Labor, United States Department of) to develop and enforce regulations for the safety and health of workers in businesses that are engaged in interstate  (OSHA OSHA
n.
Occupational Safety and Health Administration, a branch of the US Department of Labor responsible for establishing and enforcing safety and health standards in the workplace.
) required that employee exposure not exceed 0.1 mg/[m.sup.3] for an 8-hour time-weighted average (TWA).

Yet, for general industry (29 CFR 1910), marine terminals (29 CFR 1917) and longshoring (29 CFR 1918), OSHA regulations only provided a protection ceiling of I mg/10[m.sup.3]. According to OSHA's regulations, employee exposure in these industries could not exceed these specified amounts for any 10-minute period.

Then on Feb. 28, 2006, OSHA published new standards for the protection of all workers with occupational exposure to hexavalent chromium. In this rule, OSHA recognizes that workers exposed to any of these compounds are at significant risk of developing lung cancer and asthma as well as damage to nasal and skin tissue. The final rule establishes a new permissible exposure limit The Permissible Exposure Limit (PEL or OSHA PEL) is a legal limit in the United States for exposure of an employee to a substance, usually expressed in parts per million (ppm), or sometimes in milligrams per cubic metre (mg/m3).  (PEL) of 5 micrograms of hexavalent chromium per cubic meter of air for an 8-hour TWA.

During the rulemaking for this new standard, OSHA seemed to agree with many scientists and health professionals that 1 [micro]g/[m.sup.3] was a safer 8-hour TWA. Yet, ultimately OSHA determined that it would not be feasible for employees to achieve this lower exposure limit. Time will tell if this compromise standard will truly protect exposed employees. Yet, for many employees this means that the exposure limits established to protect them for many years may have been 100 times greater than what is actually safe.

WHAT IS HEXAVALENT CHROMIUM? Chromium is found in nature as part of chromite chromite (krō`mīt), dark brown to black mineral. It is an iron-chromium oxide, FeCr2O4, with traces of magnesium and aluminum.  ore (Fe[Cr.sub.2][O.sub.4]). This ore is processed to produce pure chromium metal. Chromium easily bonds with other elements to form different compounds. This bonding usually occurs when chromium (Cr) accepts electrons from other elements, thereby joining together with them. If Chromium accepts three electrons, then it is considered trivalent trivalent /tri·va·lent/ (tri-va´lent) having a valence of three.

tri·va·lent
adj.
Having valence 3.



tri·va
 chromium, or Cr (III), in that compound. If it accepts six electrons it is considered hexavalent chromium, or Cr (VI).

Compounds containing hexavalent chromium are used in electroplating electroplating: see plating.
electroplating

Process of coating with metal by means of an electric current. Plating metal may be transferred to conductive surfaces (e.g., metals) or to nonconductive surfaces (e.g.
 and the production of paint pigments, corrosion inhibitors and many other products. Workers can be exposed in the fumes fumes

odorous gases and other volatile materials; inhalation of irritating fumes causes coughing and, if sufficiently severe, irreversible pulmonary edema.
 or spray from operations using these compounds, including in scrap-related operations.

HEALTH RISKS. The most significant health risks result from exposure to hexavalent chromium particles by inhalation and through skin contact. Particles of hexavalent chromium can be in mists, dust or fumes. Mists can come from using molten metal, such as chrome plating baths or painting. Dusts can come from grinding or cutting. Fumes can be generated during torch cutting and welding operations.

When hexavalent chromium particles are inhaled, large particles may be trapped in the mucous membranes of the mouth and nose. Smaller particles may travel farther and deposit in the throat, trachea trachea (trā`kēə) or windpipe, principal tube that carries air to and from the lungs. It is about 4 1-2 in. (11.4 cm) long and about 3-4 in. (1.9 cm) in diameter in the adult.  or the left and right bronchi bronchi /bron·chi/ (brong´ki) plural of bronchus.
Bronchi
Two main branches of the trachea that go into the lungs. This then further divides into the bronchioles and alveoli.
. These particles are likely to be coughed up and swallowed.

The smallest particles will travel beyond the bronchi and deposit, ultimately, in the blood stream and be carried to the rest of the body.

The health risks from hexavalent chromium particles can include respiratory tract tumors.

Inhalation exposure to soluble hexavalent chromium can lead to nasal irritation, nasal ulcerations Ulcerations
Breaks in skin or mucous membranes that are often accompanied by loss of tissue on the surface.

Mentioned in: Hypersplenism
 and perforations, asthma and bronchitis. Direct skin contact can lead to dermatitis and skin ulceration. Direct eye contact may lead to conjunctivitis conjunctivitis (kənjəngtəvī`təs), inflammation or infection of the mucosal membrane that covers the eyeball and lines the eyelid, usually acute, caused by a virus or, less often, by a bacillus, an allergic reaction, or an .

WELDING AND TORCH CUTTING EXPOSURE. Welding or torch cutting uses intense heat from either a gas fired flame or an electric arc. This heat can bring a metal to above its boiling point. This superheating
See superheater for the device used in steam engines.


In physics, superheating (sometimes referred to as boiling retardation, or boiling delay
 converts small metal particles into metal vapor. Visible or invisible fumes form when the vapor cools and condenses back into particles. Welding smoke is an example of visible fumes. But particles can still be present even when fumes cannot be seen.

Metal particles in welding fumes can come from several sources and can vary in size from 0.00 [micro]m to 20 [micro]m. These sources include the base metal, coatings, residues or paint, electrode material, flux material and filler metal.

The boiling point for chromium is 4,841 degrees Fahrenheit. Since the heat of welding or cutting can exceed 5,432 degrees Fahrenheit, chromium particles can easily vaporize va·por·ize
v.
To convert or be converted into a vapor.


Vaporize
To dissolve solid material or convert it into smoke or gas.
 and then condense into fumes. Chromium particles generated in welding fumes can undergo a chemical reaction to become hexavalent chromium particles. Variables include electrical current, voltage, droplet droplet

very small drop of fluid.


droplet nuclei
the finite particles of matter which are transmitted from animal to animal.
 size, surface temperature, evaporation rate, shielding gas, arc length and ultraviolet radiation.

OSHA REGULATIONS. There is a specific standard for general industry, shipyards and construction.

All industries must comply with the new permissible exposure limit of 5 micrograms of hexavalent chromium per cubic meter of air (5 [micro]g/m3) for an 8-hour TWA. Exposure that falls below the action level (2.5 [micro]g/m3) has no compliance requirements. Each of the regulations has requirements for:

* Exposure determination,

* Engineering and work practice controls,

* Respiratory protection,

* Protective work clothing and equipment,

* Hygiene areas and practices,

* Medical surveillance,

* Communication of hazards to employees, and

* Recordkeeping.

For companies with 20 or more employees, all requirements of this standard, except for engineering controls, are effective Nov. 27, 2006. For businesses with 19 or fewer employees, the standard's requirements are in effect, except for engineering controls, on May 20, 2007.

THE COMPLIANCE CONCERNS. Monitoring for exposure from welding fumes is accomplished by drawing air from a worker's breathing zone through a filter. The filter is then processed in a lab to determine the amount of hexavalent chromium and other metals, such as lead and cadmium, to which the employee was exposed. This is expressed as an 8-hour TWA. While important, this monitoring alone will not provide information on the origin of the hexavalent chromium.

The origin of most particles in welding or cutting fumes is the metal being cut or welded and/or the paint, coatings or other substances on the surface of the metal. Yet, as explained above, chromium particles generated during cutting can be changed to hexavalent chromium particles.

The author owns HSR HSR homogeneously staining regions.  Consulting and advises on health, safety, loss prevention and risk management issues. He can be contacted at mikemattia@hsrconsulting. org or at (301) 318-6974.
COPYRIGHT 2006 G.I.E. Media, Inc.
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2006, Gale Group. All rights reserved. Gale Group is a Thomson Corporation Company.

 Reader Opinion

Title:

Comment:



 

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:HEALTH & SAFETY REGULATIONS
Comment:The hex: New regulations for hexavalent chromium go into effect in late November.(HEALTH & SAFETY REGULATIONS)
Author:Mattia, Mike
Publication:Recycling Today
Geographic Code:1USA
Date:Aug 1, 2006
Words:1036
Previous Article:For sale? How have unprecedented metals prices affected the value of your company?(BUSINESS CONCERNS)
Next Article:Rate of recovery: Attendees gather in the Chicago area for conferences that address paper and plastic recycling.(CONFERENCE WRAP-UP)(Paper Recycling...
Topics:



Related Articles
Lockheed Linked to Aquifer Contamination.(Brief Article)(Statistical Data Included)
HOW DANGEROUS IS CCA?
STATE SENATE CONSIDERS EFFECTS OF CHROMIUM 6.(News)
Crystalline silica remains a priority on OSHA's regulatory agenda. (Washington Alert).(Occupational Safety and Health Administration)(Brief Article)
Sanmina-SCI goes green.(Around The World / Manufacturing)(to meet European environmental regulations)(Brief Article)
OSHA issues final rule on hexavalent chromium exposure limit.(WASHINGTON ALERT)
OSHA publishes final Hexavalent Chromium Standard in three versions.(North America)
Cal-OSHA sets rules on keeping workers safe from heat.(REGULATION WATCH)
Shiny science: a new substitute for hexavalent chromium.(Innovations)
Water pollution crackdown.(REGULATION WATCH)

Terms of use | Copyright © 2009 Farlex, Inc. | Feedback | For webmasters | Submit articles