Printer Friendly
The Free Library
14,558,366 articles and books
Member login
User name  
Password 
 
Join us Forgot password?

Reliability of a diabetic foot evaluation.


Reliability of a Diabetic Foot diabetic foot A foot with a constellation of pathologic changes affecting the lower extremity in diabetics, often leading to amputation and/or death due to complications; the common initial lesion leading to amputation is a nonhealing skin ulcer, induced by  Evaluation

The purpose of this study was to establish the interrater and intrarater reliability of various ankle and foot measures common to a diabetic evaluation. Bilateral biomechanical, sensory, and wound-size measurements were obtained in 31 subjects with diabetes mellitus diabetes mellitus

Disorder of insufficient production of or reduced sensitivity to insulin. Insulin, synthesized in the islets of Langerhans (see Langerhans, islets of), is necessary to metabolize glucose. In diabetes, blood sugar levels increase (hyperglycemia).
. Twenty-five subjects were retested by the initial examiner to determine intratester reliability, and all subjects were retested by another examiner to determine intertester reliability. Both examiners participated in an extensive training period prior to the initiation of this study to minimize variability between and within measurers. Intraclass correlation coefficients for interrater and intrarater measurements ranged from .58 to .89 and from .74 to .99, respectively. The results of this study indicate that ankle and foot measurements common to a diabetic evaluation can be taken reliably between testers. We believe extensive examiner training in these clinically relevant measures can improve reliability between testers.

Key Words: Diabetes; Diabetic neuropathies; Lower extremity lower extremity
n.
The hip, thigh, leg, ankle, or foot. Also called inferior limb, pelvic limb.
, ankle and foot; Tests and measurements, range of motion.

Plantar plantar /plan·tar/ (plan´tar) pertaining to the sole of the foot.

plan·tar
adj.
Of, relating to, or occurring on the sole.
 ulceration is a serious complication that often affects patients with diabetes mellitus. Neuropathy, a common sequela sequela /se·que·la/ (se-kwel´ah) pl. seque´lae   [L.] a morbid condition following or occurring as a consequence of another condition or event.

se·quel·a
n. pl.
 of diabetes mellitus, has been implicated im·pli·cate  
tr.v. im·pli·cat·ed, im·pli·cat·ing, im·pli·cates
1. To involve or connect intimately or incriminatingly: evidence that implicates others in the plot.

2.
 as the primary cause of plantar ulceration.[1-3] Loss of sensation in the foot can allow unperceived trauma, contributing to plantar ulceration. Other contributing factors include limited joint mobility and foot deformities, both of which have been associated with the diabetic population.[4-9] These biomechanical factors may lead to excessive plantar pressure and subsequent ulceration in the presence of sensory loss. Because these factors may contribute to foot complications, it is imperative that biomechanical, sensory, and wound-size measures in a diabetic population be reliably established for use in research, evaluation, treatment, and prevention of these foot complications.

Various authors have published reports either describing or comparing devices that will standardize a biomechanical foot evaluation. Kaye and Sorto described a device called the "k-square" that measures subtalar joint (STJ STJ Superior Tribunal de Justica (Brazil)
STJ Supremo Tribunal de Justiça (Portugal)
STJ Superconducting Tunnel Junction
STJ San Giljan (postal locality, Malta) 
) range of motion, forefoot-to-rearfoot (FF/RF) relationship, and ankle dorsiflexion dorsiflexion /dor·si·flex·ion/ (dor?si-flek´shun) flexion or bending toward the extensor aspect of a limb, as of the hand or foot.

dor·si·flex·ion
n.
The turning of the foot or the toes upward.
 (DF), but no reliability for the measurements was reported.[10] Baldwin and Graebner compared the use of the k-square and the tractograph when measuring STJ ROM and FF/RF relationship. Intraclass correlation coefficients (ICCs) revealed no significant agreement between testers. No intrarater reliability was assessed, and no mention of the population measured was reported.[11] Muwanga et al developed a device that measured total ankle ROM with the foot secured to a footplace.[12] They reported no significant difference between the same or independent observers using the device in a group of healthy volunteers.

Laftanza et al reported significant differences for measurements of STJ eversion eversion /ever·sion/ (e-ver´zhun) a turning inside out; a turning outward.

e·ver·sion
n.
A turning outward, as of the eyelid.
 in a closed versus an open kinetic chain.[13] Their subjects were physical therapy students and physical therapists, and no reliability of the measurements was established. McPoil et al found high intrarater reliability (ICC ICC

See: International Chamber of Commerce
 = .90-.96) for three techniques used to measure a condition commonly referred to as "tibial varum tibial varum Orthopedics A frontal plane deformity where the distal13 of the leg is angled closer to the midsagittal plane than the proximal end ," which the authors state is more accurately termed "tibiofibular tibiofibular /tib·io·fib·u·lar/ (-fib´u-ler) pertaining to the tibia and fibula.

tib·i·o·fib·u·lar
adj.
Of, relating to, or involving both the tibia and the fibula.
 varum."[14] No interrater reliability, however, was reported. Lohmann et al analyzed tibial varum measurements obtained by two raters while healthy subjects assumed three different positions.[15] Intrarater reliability coefficients were .46 and .83 for each of the raters, and interrater reliability coefficients by position were .41, .49, and .58. Boone et al used multiple testers to assess the reliability of various upper extremity upper extremity
n.
The shoulder, arm, forearm, wrist, or hand. Also called superior limb, thoracic limb.
 and lower extremity motions.[16] The average interrater and intrarater ICCs for foot inversion were .69 and .80, respectively. This study was based on a small sample of healthy subjects (N = 12); thus, the results have little inference to the diabetic population.

To our knowledge, only two reliability studies on foot and ankle measures have used patients as subjects.[17,18] Elveru et al measured patients with neurological or orthopedic disorders.[17] The goniometric go·ni·om·e·ter  
n.
1. An optical instrument for measuring crystal angles, as between crystal faces.

2. A radio receiver and directional antenna used as a system to determine the angular direction of incoming radio signals.
 measurements were made by 14 physical therapists with limited or no experience in measuring the subtalar joint neutral subtalar joint neutral Subtalar neutral Orthopedics The position in which the forefoot is locked on the rearfoot with maximum pronation of the midtarsal joint  (STJN STJN Stichting Top Judo Nijmegen (Dutch judo association) ) position or STJ passive ROM with a goniometer goniometer /go·ni·om·e·ter/ (go?ne-om´e-ter)
1. an instrument for measuring angles.

2. a plank that can be tilted at one end to any height, used in testing for labyrinthine disease.
. They also investigated passive rearfoot inversion, eversion, and passive ankle DF and plantar flexion flexion /flex·ion/ (flek´shun) the act of bending or the condition of being bent.

flex·ion
n.
1. The act of bending a joint or limb in the body by the action of flexors.

2.
 (PF). Intrarater reliability was adequate (ICC = .6-.9), but interrater reliability was low (ICC = .1-.5). The researchers concluded that clinical measurement of the STJ and ankle may be performed somewhat reliably if the same tester takes the measurements over a short time period; however, these same measurements taken by different therapists cannot be considered reliable. Pandya et al determined intrarater and interrater reliability of goniometric measurements of seven common upper extremity and lower extremity joints in children with Duchenne muscular dystrophy Duchenne muscular dystrophy (DMD)
The most severe form of muscular dystrophy, DMD usually affects young boys and causes progressive muscle weakness, usually beginning in the legs.
.[18] Their ICC values for passive ankle DF intrarater and interrater reliability were .90 and .73, respectively. The authors concluded that goniometric measurements taken by the same examiner are highly reliable.

Decreased plantar sensation attributable to neuropathy is commonly seen in patients with diabetes. Several studies have documented the use of Semmes-Weinstein (SW) monofilaments for screening patients at risk for plantar ulcerations Ulcerations
Breaks in skin or mucous membranes that are often accompanied by loss of tissue on the surface.

Mentioned in: Hypersplenism
 secondary to Hansen's disease Hansen's disease: see leprosy.  and diabetes.[8,19,20] These studies document the 5.07 monofilament monofilament,
n a single strand of untwisted synthetic material such as nylon; used to create surgical sutures.

monofilament 
 as the best discriminator dis·crim·i·na·tor  
n.
1. One that discriminates.

2. Electronics A device that converts a property of an input signal, such as frequency or phase, into an amplitude variation, depending on how the signal differs from a
 for feet susceptible to ulceration.

The purpose of this study was to determine the interrater and intrarater reliability of various foot and ankle measurements, taken by experienced physical therapists, in a group of diabetic patients vulnerable to serious foot complications. Specifically, we assessed the following measures: passive calcaneal calcaneal /cal·ca·ne·al/ (kal-ka´ne-al) pertaining to the calcaneus.

calcaneal

arising from or pertaining to the calcaneus.
 inversion and eversion, palpated STJN, FF/RF relationship in STJN, passive talocrural DF, sensation level, ulcer area and depth, calcaneal stance position, and tibial varum. We expected all measures would be reliable between and within raters because of extensive examiner training.

Method

Subjects

Thirty-one volunteers participated in this study. Subjects were recruited from patients referred to physical therapy from the diabetic foot center at Washington University Medical School and by private physicians. The purpose and procedure of the study were explained to each prospective subject, and informed consent was obtained. Subject characteristics are shown in Table 1.

Materials

A standard plastic goniometer with the scale marked in 2-degree increments was used for all biomechanical measurements. Semmes-Weinstein monofilaments 4.17, 5.07, and 6.10 were used for sensation measurements. An indelible ink marker was used to trace the ulcer area on a piece of sterilized ster·il·ize  
tr.v. ster·il·ized, ster·il·iz·ing, ster·il·iz·es
1. To make free from live bacteria or other microorganisms.

2.
 x-ray film,[21] and a modified slide rule was used to measure ulcer depth.

Procedure

We used a test-retest design, with the same subject assessed three times during each session. To assess interrater reliability, subjects were randomly tested by one of the two testers (JED JED Journal of Electronic Defense
JED Jeddah, Saudi Arabia - Jeddah International (Airport Code)
JED Juntas Electorales Departamentales (Guatemala)
JED Japan Engineer District
JED Joint Exercise Division
, MJM MJM Multi-Jet Modeling (prototyping manufacturing)
MJM Metropolitan Japanese Ministry
MJM Married Jewish Male
) and next by the other tester. To assess intrarater reliability, the subject was measured a third time by one of the testers, again determined randomly. Each evaluation took about 15 minutes to complete. Testers were in separate rooms when the measurements were taken. Interrater measurements were obtained for 31 subjects (17 men, 14 women), and intrarater measurements were obtained for 25 subjects (14 men, 11 women). Six subjects were not assessed a third time because of time constraints. Not all subjects had plantar ulceration. Ulcer size and depth were measured by the same tester on 14 subjects and by different testers on 9 subjects.

Both examiners underwent a lengthy training period with the measures used in this evaluation. Training sessions consisted of the evaluation of patients by each therapist independent of the other. Each patient's measurements were discussed and remeasured jointly if discrepancies existed. Approximately 20 of these training sessions were conducted over an 18-month period prior to this experiment. Both examiners commonly (ie, daily) used these measures in their clinical practice.

A standard biomechanical examination procedure described by McPoil and Brocato was used.[22] Briefly, patients were positioned prone with the leg not being examined flexed at the knee, laterally rotated, and abducted abducted Distal angulation of an extremity away from the midline of the body in a transverse plane and away from a sagittal plane passing through the proximal aspect of the foot or part, or away from some other specified reference point  at the hip. The lower third of the tested leg and the calcaneus calcaneus /cal·ca·ne·us/ (kal-ka´ne-us) pl. calca´nei   [L.] heel bone; the irregular quadrangular bone at the back of the tarsus. calca´nealcalca´nean

cal·ca·ne·us or cal·ca·ne·um
n.
 were bisected. For passive calcaneal inversion and eversion, the calcaneus was secured with one hand, maximally inverted inverted

reverse in position, direction or order.


inverted L block
a pattern of local filtration anesthesia commonly used in laparotomy in the ox.
 or everted, and measured from anatomical zero. The goniometer arms were aligned with the bisection bisection /bi·sec·tion/ (bi-sek´shun) division into two parts by cutting.

bisection

division into two parts by cutting.
 of the calcaneus and the bisection of the lower third of the leg. Palpated STJN is the position of inversion or eversion the calcaneus assumes, in relationship to the tibia tibia: see leg. , when the talus talus (tā`ləs), deposit of rock fragments detached from cliffs or mountain slopes by weathering and piled up at their bases. A talus is a common geologic feature in regions of high cliffs.  position is congruent between palpating fingers. The foot is passively pronated and supinated until the medial and lateral sides of the talar head are neither protruding pro·trude  
v. pro·trud·ed, pro·trud·ing, pro·trudes

v.tr.
To push or thrust outward.

v.intr.
To jut out; project. See Synonyms at bulge.
 nor depressed. The fourth and fifth metatarsal metatarsal /meta·tar·sal/ (met?ah-tahr´sal)
1. pertaining to the metatarsus.

2. a bone of the metatarsus.


met·a·tar·sal
adj.
Of or relating to the metatarsus.
 heads are then passively dorsiflexed, locking the midtarsal joints, and the calcaneal position is then measured as described previously. To determine the FF/RF relationship, first the STJN position is located. The goniometer is then placed with one arm parallel to the plane of the metatarsal heads and the other arm aligned perpendicular to the bisection of the calcaneus. Passive talocrural DF is also measured by first finding the STJN position. The axis of the the diameter of the sphere which is perpendicular to the plane of the circle.

See also: Axis
 goniometer is then placed over the lateral malleolus, and one arm is aligned with the lateral border of the foot while the other arm is aligned with the lateral border of the lower leg. The examiner then passively dorsiflexes the talocrural joint talocrural joint
n.
See ankle joint.
, and the angle is measured.

Sensation at the plantar surface of the foot was measured using 4.17, 5.07, or 6.10 SW monofilament similar to the method described by Birke and Sims.[19] Sites for testing were the first, third, and fifth toes and their associated metatarsal head; the medial (at the base of the first metatarsal) and lateral midfoot (at the base of the fifth metatarsal); and the heel. The monofilament was pressed perpendicular to the surface of the skin with enough pressure to bend the monofilament. The higher the value of the monofilament, the more difficult it is to bend. Five to 10 trials were performed at each site, and the subject needed to perceive 80% of the trials to be graded a given value at that site. If the subject was unable to sense at least 80% of the trials, he or she would be tested with the next highest monofilament. If the subject was unable to sense 80% of the trials using the 6.10 monofilament, he or she was graded the value "[is greater than] 6.10." The highest perceived monofilament value at any of the sites was taken as the overall grade of the foot.

If an ulcer was present, area measurements were obtained by tracing the circumference of the wound onto sterilized x-ray film.[21] Area was computed with a sonic digitizer.(*) Ulcer depth was obtained by placing the edge of a modified slide rule at the ulcer's deepest point.

The subject was then asked to stand, and calcaneal stance was measured by aligning one arm of the goniometer with the calcaneal bisect bi·sect  
v. bi·sect·ed, bi·sect·ing, bi·sects

v.tr.
To cut or divide into two parts, especially two equal parts.

v.intr.
To split; fork.
 and the other arm parallel with the floor. Tibial varum was measured with the subject in relaxed single leg stance and with one arm of the goniometer aligned with the bisect of the lower third of the leg and the other arm parallel with the floor. All marks on the leg were then washed off, and the subject was measured by the next examiner.

Data Analysis

Reliability was assessed using ICCs (formula 2,1)[23] for all measures except sensation testing. Reliability for sensation measurement was determined by Cohen's Kappa statistic.[24]

Criteria for acceptable reliability were partially based on the work of Lahey et al[23] and included a minimal acceptable ICC of .70. Acceptable criteria for the Kappa statistic were based on the work of Landis and Koch,[25] who stated that a Kappa value of [is greater than or equal to] .61 infers a "moderate" strength of agreement.

In addition, we calculated the standard error of measurement (SEM) for all data except sensation using the formula[26]:

SEM = SD x [(1 - r).sup.1/2] were SD is the standard deviation In statistics, the average amount a number varies from the average number in a series of numbers.

(statistics) standard deviation - (SD) A measure of the range of values in a set of numbers.
 and r is the correlation coefficient Correlation Coefficient

A measure that determines the degree to which two variable's movements are associated.

The correlation coefficient is calculated as:
. The SEM is used to estimate the "reasonable limits" of the true score for a person with any obtained score; therefore, it is useful in the interpretation of the reliability of a single score.

Results

The means and standard deviations for all goniometric measurements are summarized in Table 2. Results of the interrater and intrarater ICCs and SEMs for goniometric measurements are summarized in Table 3. Intrarater reliability coefficients ranged from .74 to .99, and interrater reliability coefficients ranged from .58 to .89. All intrarater reliability coefficients were acceptable. Kappa values for interrater and intrarater reliability for sensation testing ranged from .72 to .83. Distribution of patients according to sensation measurements is summarized in Table 4. The mean ulcer area and depth were 1.0 [+ or -] 0.9 [cm.sup.2] and 3.4 [+ or -] 2.4 mm, respectively. The ICC value of interrater and intrarater reliability for ulcer area was .99. The ICC values for interrater and intrarater reliability of ulcer depth measurements were .92 and .99, respectively. The SEM for ulcer depth and ulcer area was zero.

Discussion

Two previous studies examined the reliability of foot and ankle goniometric measurements in patient populations.[17,18] Our study differs from those of Elveru et al[17] and Pandya et al[18] in two basic ways. Our study involved only two testers (Elveru et al's study[17] involved 14 testers, and Pandya et al's study[18] involved 5 testers), and the testers had undergone extensive training with the measures involved in our evaluation. Elveru et al's examiners had limited or no experience in measuring the STJN position or passive STJ ROM. Pandya et al's examiners were "five experienced therapists," but there is no mention of examiner training with the measurements used. Elveru et al's study reported poor interrater reliability for STJN and passive STJ ROM measurements, but this finding is not surprising because the therapists had limited or no experience in these measures.

We attempted to minimize our measurement variability by undergoing extensive training in the measures being used. Our results indicated acceptable interrater reliability for all except four measurements (Tab. 3). Our results indicate that the same rater may reliably take foot and ankle measurements in this patient population. Different measurers, with training, may be reliable with certain foot and ankle measurements in this population. The extensive training our examiners have undergone, however, infers the generalization of our results only to other examiners who have undertaken similar training. We believe the most important aspects of these training sessions were defining and agreeing on common techniques of measurement. Although clinicians may believe they use similar measurement techniques, comparing outcome measurements often proves otherwise. The training sessions offered an opportunity to discover and correct these differences, which decreased variability in the measure. Although our training encompassed an 18-month time period, a shorter time period with more frequent sessions may achieve similar results.

Our acceptable reliability findings using the SW monofilaments to measure sensation agree with the results of Birke and Sims[19] and Holewski et al.[20] Sensation measurements obtained with SW monofilaments are reliable, require minimal training to perform, and appear to be a valid indicator of sensory loss.[8,19,20] We also found that measuring wound area by tracing the circumference of the ulcer onto sterilized x-ray film[21] was extremely reliable and offered a good comparison of wound size for future office visits. Unlike the biomechanical measures, taking reliable wound measurements appears to require minimal training.

Interestingly, although several ICC values were unacceptable, we found relatively low SEMs. The SEM is useful in the interpretation of the reliability of a single score. Thus, the SEM is a useful statistic in clinical settings for estimating the range of values within which a patient's "true" value may lie. Caution must be exercised when interpreting the SEM because this measure is "end sensitive." That is, as the obtained value approaches the extremes of the distribution, the SEM will increase dramatically. Nevertheless, if values obtained in applied settings are near the means obtained in this study, the low SEMs can be interpreted to mean that a patient's true value may lie within a very small range of the obtained value. For example, if a clinician measures calcaneal inversion at 22 degrees (the mean obtained in this study) in a diabetic patient, the true value can be interpreted to fall within a range of 18 to 26 degrees (using the obtained value of [plus or minus] 2 SEMs).

The magnitude of the SEM is directly related to the standard deviation and indirectly related to the correlation coefficient between the test-retest values. As the correlation coefficient approaches 1, the SEM approaches zero. As the standard deviation decreases, however, so does the SEM. The range of values for most of the measurements obtained in this study is relatively low. As Lahey et al[23] have pointed out, restricted ranges have a deleterious effect on obtained reliability coefficients. Thus, we are left with contradictory results: although the reliability coefficients at times appear to be unacceptable, the obtained SEMs are certainly within acceptable and useful ranges for the clinician. For example, the measure of tibial varum had low interrater reliability coefficients (ICC = .66 and .62 for left and right sides, respectively), although it had acceptable intrarater reliability (ICC = .84 and .86 for left and right sides, respectively). The SEM for both intrarater and interrater tibial varum measurements, however, was 1 degree (Tab. 3). Even with a conservative estimate of [plus or minus] 2 SEMs, a clinician obtaining a tibial varum measurement of 9 degrees should expect the "true" value to fall within a range of 7 to 11 degrees for both interrater and intratester situations. Consequently, we believe that judging the reliability of some measurements obtained in this study needs further clarification beyond failing to meet the predetermined pre·de·ter·mine  
v. pre·de·ter·mined, pre·de·ter·min·ing, pre·de·ter·mines

v.tr.
1. To determine, decide, or establish in advance:
 ICC acceptability level of [is greater than or equal to] .70.

Alternative explanations for obtaining low reliability coefficients should be ruled out before a measure is judged unreliable. Lahey et al suggest ruling out the following explanations before concluding that a measure is unreliable: 1) sampling from a restricted range of values, thus decreasing between intrarater and interrater variability and artificially decreasing the obtained ICC value; 2) interrater interactions, usually resulting when one rater misinterprets instructions (eg, consistently misreads the goniometer in the opposite direction); and 3) low intertrial correlations.[23] Accordingly, we have attributed the low ICC values obtained in this study to the small range of measurements sampled and measurement. As mentioned previously, Lahey et al noted that data with a restricted range of values have a deleterious effect on the obtained reliability coefficients.[23] Furthermore, they point out that low reliability coefficients obtained from values in a restricted range should not necessarily be interpreted as unreliable. Instead, they suggest stratifying the sample to increase the range of values. This strategy was not practical in our study. Instead, we can only point out that although some reliability coefficients did not meet our predetermined level of acceptability, this fact alone does not infer that the measure is unreliable. We have outlined this situation with interrater assessment of tibial varum measurements, and we point out that analogous situations exist in all other measures with ICC values below .70.

Conclusion

A foot and ankle evaluation is an important consideration for diabetic patients because of the frequency of injury or disability of this area of the body. We have shown that in the test-retest situation of this foot and ankle evaluation, the SEMs of all measures were sufficiently low for them to be clinically useful. These results indicate that therapists who train extensively can take many clinical foot and ankle measurements in the diabetic population reliably. [Tabular Data 1 to 4 Omitted]

(*)Sciences Accessories, Inc, 970 Kings Hwy W, Southport, CT 06490.

References

[1]Levin ME: The Diabetic Foot, ed 4. St Louis, MO, C V Mosby Co, 1988 [2]Brand PW: The diabetic foot. In Ellenberg M, Rifkin H (eds): Diabetes Mellitus: Theory and Practice, ed 3. New Hyde Park New Hyde Park, village (1990 pop. 9,728), Nassau co., SE N.Y., on Long Island; inc. 1927. It is a residential community with some manufacturing and truck farms. Nearby is the uninc. town of North New Hyde Park (1990 pop. 14,359). , NY, Medical Examination Publishing Co Inc, 1983, pp 829-849 [3]Boulton AJ, Betts RP, Franks CI, et al: The natural history of foot pressure abnormalities in neuropathic diabetic subjects. Diabetes Res 5:73-77, 1977 [4]Grigic A, Rosenbloom AL, Weber TF, et al: Joint contractures Joint contractures
Stiffness of the joints that prevents full extension.

Mentioned in: Mucopolysaccharidoses
 common manifestation of childhood diabetes. J Pediatr 88:584-588, 1976 [5]Rosenbloom AL, Silverstein JH, Lexotte DC, et al: Limited joint mobility in childhood diabetics indicates increased risk for microvascular diseases. N Engl J Med 305:191-194, 1982 [6]Rosenbloom AL, Silverstein JH, Riley WJ, et al: Limited joint mobility in childhood diabetics: Family studies. Diabetes Care 6:370-373, 1983 [7]Shinabarger NA: Limited joint mobility in adults with diabetes mellitus. Phys Ther 67:215-218, 1987 [8]Mueller MJ, Diamond JE, Delitto A, et al: Insensitivity, limited joint mobility, and plantar ulcers in patients with diabetes mellitus. Phys Ther 69:453-459, 1989 [9]Birke JA, Cornwall MW, Jackson M: Relationship between hallux hallux /hal·lux/ (hal´uks) pl. hal´luces   [L.] the great toe.

hallux doloro´sus  a painful condition of the great toe, usually associated with flatfoot.

hallux flex´us  h.
 limitus and ulceration of the great toe. Journal of Orthopaedic and Sports Physical Therapy 10:172-176, 1988 [10]Kaye JM, Sorto LA: The k-square: A new biomechanical measuring device for the foot and ankle. J Am Podiatr Assoc 69:58-64, 1979 [11]Baldwin EB, Graebner JE: A comparison of the k-square and tractograph. J Am Podiatr Assoc 72:629-633, 1982 [12]Muwanga CL, Dove AF, Plant GR: The measurement of ankle movements: A new method. Injury 16:312-314, 1985 [13]Laftanza L, Gray GW, Kantner RM: Closed versus open kinematic chain measurements of subtalar joint eversion: Implications for clinical practice. Journal of Orthopaedic and Sports Physical Therapy 9:310-314, 1988 [14]McPoil TG, Schuit D, Knecht HG: A comparison of three positions used to evaluate tibial varum. J Am Podiatr Med Assoc 78:22-28, 1988 [15]Lohmann KN, Rayhel HE, Schneiderwind WP, et al: Static measurement of tibia vara tibia var·a
n.
Bowleg.
: Reliability and effect of lower extremity position. Phys Ther 67:196-202, 1987 [16]Boone DC, Azen SP, Lin C-M C-M Control-Monitor
C-M Constant Modulus
, et al: Reliability of goniometric measurements. Phys Ther 58:1355-1360, 1978 [17]Elveru RA, Rothstein JM, Lamb RL: Goniometric reliability in a clinical settings: Subtalar and ankle joint ankle joint
n.
A hinge joint formed by the articulating of the tibia and the fibula with the talus below. Also called mortise joint, talocrural joint.
 measurements. Phys Ther 68:672-677, 1988 [18]Pandya S, Florence JM, King WM, et al: Reliability of goniometric measurements in patients with Duchenne muscular dystrophy. Phys Ther 65:1339-1342, 1985 [19]Birke JA, Sims DS: Plantar sensory threshold in the Hansen's disease ulcerative ulcerative /ul·cer·a·tive/ (ul´se-ra?tiv) (ul´ser-ah-tiv) pertaining to or characterized by ulceration.

ulcerative

pertaining to or characterized by ulceration.
 foot. In: Proceedings of the International Conference of Biomechanics and Clinical Kinesiology of Hand and Foot. Madras, India, December 16-18, 1985, pp 137-138 [20]Holewski JJ, Stress RM, Graf PM, et al: Aesthesiometry: Quantification of cutaneous cutaneous /cu·ta·ne·ous/ (ku-ta´ne-us) pertaining to the skin.

cu·ta·ne·ous
adj.
Of, relating to, or affecting the skin.


Cutaneous
Pertaining to the skin.
 pressure sensation in diabetic peripheral neuropathy Diabetic peripheral neuropathy
A condition where the sensitivity of nerves to pain, temperature, and pressure is dulled, particularly in the legs and feet.

Mentioned in: Diabetes Mellitus
. J Rehabil Res Dev 25:1-10, 1988 [21]Bohannon RW, Pfaller BA: Documentation of wound surface area from tracings of wound perimeters: Clinical report of three techniques. Phys Ther 63:1622-1624, 1983 [22]McPoil TG, Brocato RS: The foot and ankle: Biomechanical evaluation and treatment. In Gould JA, Davies GJ (eds): Orthopaedic and Sports Physical Therapy. St Louis, MO, C V Mosby Co, 1985, vol 2, pp 313-341 [23]Lahey MA, Downey RG, Saal FE: Intraclass correlations: There's more there than meets the eye. Psychol Bull 93:586-595, 1983 [24]Cohen cohen
 or kohen

(Hebrew: “priest”) Jewish priest descended from Zadok (a descendant of Aaron), priest at the First Temple of Jerusalem. The biblical priesthood was hereditary and male.
 J: A coefficient of agreement for nominal scales. Educational and Psychological Measurement 20:27-36, 1960 [25]Landis RJ, Koch GG: The measurement of observer agreement for categorical data categorical data

data relating to category such as qualitative data, e.g. dog, cat, female. It may be nominal when a name is used, e.g. location, breed, or ordinal when a range of categories is used, e.g. calf, yearling, cow.
. Biometrics 33:159-174, 1977 [26]Anastasi A: Psychological Testing, ed 6. New York New York, state, United States
New York, Middle Atlantic state of the United States. It is bordered by Vermont, Massachusetts, Connecticut, and the Atlantic Ocean (E), New Jersey and Pennsylvania (S), Lakes Erie and Ontario and the Canadian province of
, NY, Macmillan Publishing Co, 1988, pp 133-135

J Diamond, MHS (1) (Message Handling Service) An earlier messaging system from Novell that supported multiple operating systems and other messaging protocols, including SMTP, SNADS and X.400. It used the SMF-71 messaging format. , PT, is Physical Therapy Supervisor, Department of Physical Therapy, Irene Walter Johnson Rehabilitation Institute, Washington University Medical School, 509 S Euclid Ave, St Louis, MO 63110 (USA). M Mueller, MHS, PT, is Instructor, Program in Physical Therapy, Washington University Medical School, and Physical Therapist, Department of Physical Therapy, Irene Walter Johnson Rehabilitation Institute. A Delitto, MHS, PT, is Instructor, Program in Physical Therapy, Washington University Medical School, and Consulting Physical Therapist, Department of Physical Therapy, Irene Walter Johnson Rehabilitation Institute. D Sinacore, MHS, PT, is a physical therapist and a doctoral candidate, Department of Anatomy, School of Medicine, West Virginia University West Virginia University, mainly at Morgantown; coeducational; land-grant and state supported; est. and opened 1867 as an agricultural college, renamed 1868. , Morgantown, WV 26506.
COPYRIGHT 1989 American Physical Therapy Association, Inc.
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 1989, Gale Group. All rights reserved. Gale Group is a Thomson Corporation Company.

 Reader Opinion

Title:

Comment:



 

Article Details
Printer friendly Cite/link Email Feedback
Author:Sinacore, David R.
Publication:Physical Therapy
Date:Oct 1, 1989
Words:3988
Previous Article:Save Your Knees.
Next Article:Isokinetic, electrophysiologic, and clinical function relationships following tourniquet-aided knee arthrotomy.
Topics:



Related Articles
A neuropathic foot - a management scheme: a case report.
Insensitivity, limited joint mobility, and plantar ulcers in patients with diabetes mellitus. (includes commentary and response)
Relationship of foot deformity to ulcer location in patients with diabetes mellitus.
Methods of treating plantar ulcers. (clinical perspective)
Effect of total contact cast immobilization on subtalar and talocrural joint motion in patients with diabetes mellitus.
Differences in the gait characteristics of patients with diabetes and peripheral neuropathy compared with age-matched controls. (includes commentary...
Use of Computed Tomography and Plantar Pressure Measurement for Management of Neuropathic Ulcers in Patients With Diabetes.
Management of the Diabetic Foot: Preventing Amputation. (Featured CME Topic: Diabetes Mellitus).
Chronic complications of diabetes. (Featured CME Topic: Diabetes Mellitus).
Diabetic foot: Evaluation and Management. (Review Article).

Terms of use | Copyright © 2009 Farlex, Inc. | Feedback | For webmasters | Submit articles