Relationship of knee extension force to independence in sit-to-stand performance in patients receiving acute rehabilitation. (Research Report).The inability to rise from a sitting position is recognized by the World Health Organization (WHO) as a disabling dis·a·ble tr.v. dis·a·bled, dis·a·bling, dis·a·bles 1. To deprive of capability or effectiveness, especially to impair the physical abilities of. 2. Law To render legally disqualified. condition. (1) Sit-to-stand (STS (Synchronous Transport Signal) The electrical equivalent of the SONET optical signal. In SDH, the European counterpart of SONET, STS is known as STM (Synchronous Transport Module). ) performance correlates with walking speed, independent ambulation am·bu·late intr.v. am·bu·lat·ed, am·bu·lat·ing, am·bu·lates To walk from place to place; move about. [Latin ambul , and stair climbing Stair climbing is the climbing of a flight of stairs. It is often described as a "low-impact" exercise, often for people who have recently started trying to get in shape. A common phrase in health pop culture is "Take the stairs, not the elevator". . (2, 3) Difficulty in rising from a sitting position is a predictor of future disability, (4) falls, (5) nursing home use, (6) increased utilization of hospital services, (7) and mortality. (8) Sit-to-stand performance is one of the activities used in functional indexes and in test batteries of physical functioning. (4, 9, 10) Completion of the STS maneuver is fundamental to transfers and the initiation of gait. Sit-to-stand performance is reduced in many older individuals, particularly women and those who have various pathologies. (4, 9, 11-19) The ability to complete an independent chair rise successfully is highly valued by older individuals. (20) Although STS performance has been found to be influenced by lower-extremity range of motion and balance, the physiologic variable shown most consistently to relate to STS performance is lower-extremity muscle force. (3,10,17-19,21-23) Wretenberg and Aborelius (23) found that the knee extensors contribute 72% of the concentric force at the hip and the knee joint during STS. Bohannon (17) estimated that 330 N is needed in bilateral knee extension force (KEF kef n. Variant of kif. ) to successfully stand up once from a chair, but he did not account for body weight. Ploutz-Snyder et al (24) indicated that individuals with a force-to-weight ratio of <3.0 N*m/kg are at substantial risk of reduced function in rising from a chair. Other researchers, (21) however, have described KEF as a predictor of STS success only when considered in combination with plantar-flexion and hip extension forces. Furthermore, Tinetti and Ginter (22) reported that only 44% of people with chair-rise problems had decreased KEF. They, however, used manual muscle testing (MMT MMT Million Metric Tons MMT Médecins Maîtres-Toile MMT Methadone Maintenance Treatment MMT Multiple Mirror Telescope MMT Mission Management Team (International Space Station) MMT Military Training Technology ), which we consider a subjective measure of force with low sensitivity above the grade 3/5 level. (25) Although KEF has an established relationship to STS performance, (3,17-19,21,23,24) we believed the measure's relevance might be enhanced by normalization In relational database management, a process that breaks down data into record groups for efficient processing. There are six stages. By the third stage (third normal form), data are identified only by the key field in their record. using other variables. Measurements of KEF have been normalized to body weight, but on a limited basis. (3,18,21,26) We consider this noteworthy because muscle force is known to correlate with body weight. In our opinion, therefore, KEF output, when measured with a dynamometer dynamometer /dy·na·mom·e·ter/ (di?nah-mom´e-ter) an instrument for measuring the force of muscular contraction. dy·na·mom·e·ter n. An instrument for measuring the degree of muscular power. , might better reflect a force-generation impairment when normalized against body weight. Reference values ref·er·ence values pl.n. A set of laboratory test values obtained from an individual or from a group in a defined state of health. for KEF for male (n=106) and female (n=125) subjects in different age groups have been published. (26) Therefore, it is possible to normalize normalize to convert a set of data by, for example, converting them to logarithms or reciprocals so that their previous non-normal distribution is converted to a normal one. force measurements with the variables of age and sex. The relevance of KEF, we believe, also might be enhanced through the establishment of a cutoff point Cutoff point The lowest rate of return acceptable on investments. , a value that divides a distribution of scores into 2 classes or categories. A KEF cutoff point, therefore, could serve to formulate goals in therapy or to justify use of an assistive device assistive device Public health Any device designed or adapted to help people with physical or emotional disorders to perform actions, tasks, and activities. See Americans with Disabilities Act, Architectural barriers, Assistive technology. . Requirements for KEF will vary with use of the upper extremities on armrests, (19,27) due to chair height, (18,28,29) and with the technique used to stand. (18) Chair height has been found to be a determinant of a person's rising successfully from a chair. (18,28-31) The knee flexion flexion /flex·ion/ (flek´shun) the act of bending or the condition of being bent. flex·ion n. 1. The act of bending a joint or limb in the body by the action of flexors. 2. moment, and therefore the demand on the knee extensors, will increase with a decrease in chair height. (18,28,29) Similarly, the demand on the knee extensors of taller individuals may be greater than for shorter individuals when rising from a standard-height chair. Upper-extremity assistance at the time of standing, when the knee flexion moment is greatest, will decrease the knee flexion moment and thus the KEF requirement of the task. (19,27) Some older individuals use a stability-maximizing technique during STS. This technique, in which the center of mass is positioned over the base of support before standing is initiated, requires a greater KEF than a technique that uses momentum. (28) The purpose of our study was to determine the role of KEF relative to weight, height, sex, and age in completion of one STS maneuver, whether or not the upper extremities were used for assistance. We also sought to establish sensitive, specific, and valid cutoff points of different KEF measures for predicting independence in rising from a chair. Method Subjects We conducted a descriptive and correlational study that involved the recording, in a separate database, of information from the medical records of patients who were referred and seen by a physical therapist (RWB RWB Reporters Without Borders RWB Red/White/Blue RWB Royal Winnipeg Ballet RWB Responsive Workbench (3D interactive VR workspace) RWB Renommierte Weingüter Burgenland ) for acute rehabilitation rehabilitation: see physical therapy. . There were 107 subjects, all of whom were taken from the caseload case·load n. The number of cases handled in a given period, as by an attorney or by a clinic or social services agency. caseload Noun of the second author. Subjects were included in the study if they were able to follow directions, had no lower-extremity amputations, and had no restrictions on lower-extremity movement or weight bearing ordered by a physician. The subjects were highly variable in age, size, diagnoses, ambulatory independence, and use of assistive devices. The mean age of the subjects was 62.1 years (SD=16.4, range=24-97). Measurements of weight and height were obtained from their medical records. Their mean weight was 76.7 kg (SD=25.3, range=37.3-198.2), and their mean height was 168.6 cm (SD=11.4, range=147.3-193.0). Fifty-five (51.4%) of the subjects were men, and 52 (48.6%) were women. The subjects were divided into 6 groups based on diagnosis (frequency indicated in parentheses See parenthesis. parentheses - See left parenthesis, right parenthesis. ): neuromuscular neuromuscular /neu·ro·mus·cu·lar/ (-mus´ku-ler) pertaining to nerves and muscles, or to the relationship between them. neu·ro·mus·cu·lar adj. 1. (n=61), postsurgical (n=7), cardiovascular or pulmonary (n=19), trauma (n=4), cancer (n=7), and other (n=9). For descriptive purposes, ambulatory function was quantified by use of the Functional Independence Measure (FIM FIM The ISO 4217 currency code for the Finnish Markka. ). The FIM score was assigned based on the Guide to the Uniform Data Set for Medical Rehabilitation, version 5.0. (32) The distribution of subjects with an FIM gait score was as follows: FIM 1 (n=27), FIM 2 (n=22), FIM 3 (n=2), FIM 4 (n=22), FIM 5 (n=21), FIM 6 (n=4), FIM 7 (n=9). The use of ambulatory assistive devices was as follows: no device (n=54), cane (n=8), quad cane (n=2), hemiwalker (n=5), rolling platform walker (n=7), rolling walker (n=26), and standard walker (n=5). Of the 54 subjects who were categorized cat·e·go·rize tr.v. cat·e·go·rized, cat·e·go·riz·ing, cat·e·go·riz·es To put into a category or categories; classify. cat as using no device, 29 were hand assisted by the tester. Equipment The instrumented measurements of the subjects' KEFs were obtained using 2 digital hand-held dynamometers (HHDs) and a standard-height chair. The HHDs (Ametek Cadet Gauge and Ametek Accuforce II) * were calibrated cal·i·brate tr.v. cal·i·brat·ed, cal·i·brat·ing, cal·i·brates 1. To check, adjust, or determine by comparison with a standard (the graduations of a quantitative measuring instrument): periodically over the course of the study and found to be accurate within 1 N. The chairs used were all armless with a slightly padded seat and 44 to 46 cm high. Such chairs are representative of those typically encountered in everyday life. Procedure Maximum isometric isometric /iso·met·ric/ (-met´rik) maintaining, or pertaining to, the same measure of length; of equal dimensions. i·so·met·ric adj. 1. KEF was tested by one examiner (RWB) who had over 20 years of experience using HHDs and MMT. The reliability of HHD (Hybrid Hard Drive) See hybrid drive. measurements obtained by the examiner has been established previously for both patients and individuals without known impairments or pathology. (33) The reliability of MMT scores also has been established by Wadsworth et al. (34) They reported reliability coefficients of .63 to .98 for 11 patients with chronic orthopedic and neuromuscular disorders. Subjects were tested with the HHD while seated upright with the leg vertical and the knee in approximately 90 degrees of flexion to decrease the influence of gravity during testing. They were not allowed to lean back Verb 1. lean back - move the upper body backwards and down recline lean, tilt, angle, slant, tip - to incline or bend from a vertical position; "She leaned over the banister" fall back - fall backwards and down in the chair while being tested. The subjects were asked to take 1 or 2 seconds to come to maximum effort, during which they were to push as hard as possible into the HHD. The counterforce coun·ter·force n. A contrary or opposing force, especially a military force capable of destroying the nuclear armaments of an enemy. to the KEF was applied by the tester through the HHD, which was perpendicular and just proximal to the malleoli. The subjects were given encouragement and were asked to stop after 4 to 5 seconds. They were given one trial for each lower extremity lower extremity n. The hip, thigh, leg, ankle, or foot. Also called inferior limb, pelvic limb. . (35) The peak forces for both lower extremities were recorded in pounds and converted to newtons. Because we were interested in the force that could be used to lift the body's weight against the pull of gravity, we summed the KEF values of the 2 sides and labeled them "HHD (total force)." The HHD (total force) values were normalized based on body weight and labeled "HHD (weight normalized)." This value was further normalized based on age and sex by dividing HHD (weight normalized) by the expected bilateral KEF output of the appropriate age- and sex-referenced described by Bohannon. (26) This category was "labeled HHD (norm referenced)" and was limited to subjects (n=106) in the age range to which the reference values applied. (26) The MMT of KEF was conducted according to according to prep. 1. As stated or indicated by; on the authority of: according to historians. 2. In keeping with: according to instructions. 3. the technique described by Hislop and Montgomery. (36) Patients with grades greater than 2 were tested in the chair used for the STS and HHD testing. The numerical grading system (0-5) of the Medical Research Council (MRC See Maximum return criterion. ) was used. (37) Pluses and minuses were designated when required. The scores from one trial of each lower extremity were then converted to a categorical ordinal (mathematics) ordinal - An isomorphism class of well-ordered sets. score (0-12) to facilitate analysis. Consistent with the treatment of HHD values, the ordinal scores assigned to the original MRC grades were as follows: 0=0, 1=1, [1.sup.+]=2, [2.sup.-]=3, 2=4, [2.sup.+]=5, [3.sup.-]=6, 3=7, [3.sup.+]=8, [4.sup.-]=9, 4=10, [4.sup.+]=11, and 5=12. The ordinal scores of both KEF measures were added together (maximum possible score=24) and labeled "MMT (total)." Following assumption of a forward position on the seat with their feet flat on the floor, the subjects were given 3 opportunities to attain a standing position without use of their upper extremities (STS [without hands]). Subjects were classified as "able" (1) or "unable" (0). If unable to stand without use of the upper extremities, subjects were given 3 opportunities to stand using the upper extremities (STS [with hands]), that is, by pushing down on the chair or their thighs. They were again classified as "able" (1) or "unable" (0). Data Analysis Data analysis was conducted using SYSTAT 10.0 for Windows (38) and SPSS A statistical package from SPSS, Inc., Chicago (www.spss.com) that runs on PCs, most mainframes and minis and is used extensively in marketing research. It provides over 50 statistical processes, including regression analysis, correlation and analysis of variance. 10.0 for Windows. (39) Descriptive statistics descriptive statistics see statistics. were calculated first. Zero-order correlations (Pearson r) were calculated among KEF, age, sex, height, weight, and STS performance under 2 conditions (STS [without hands] and STS [with hands]). The correlations were point-biserial correlations because the dependent variable was dichotomous di·chot·o·mous adj. 1. Divided or dividing into two parts or classifications. 2. Characterized by dichotomy. di·chot (able versus unable to rise). Hotelling See hoteling. T analyses were used to determine if there was a difference between the KEF measures in their ability to explain STS independence. Because variables in the study were dichotomous (able versus unable to complete STS), a forward logistic regression In statistics, logistic regression is a regression model for binomially distributed response/dependent variables. It is useful for modeling the probability of an event occurring as a function of other factors. analysis was used to determine the effects of multiple independent variables on STS independence. The KEF variables had the highest correlations with STS performance; therefore, these values were introduced first into each prediction model for STS (without hands) and STS (with hands). The subject's age, sex, weight, and height were then added if not already accounted for through normalization. Weight was not entered into the model including HHD (weight normalized) because this KEF measure was already normalized to body weight. Weight, age, and sex were not entered into the model including HHD (norm referenced) because that variable was already normalized based on those measures. Receiver operating characteristic (ROC) curves (40) were generated for the 4 KEF variables (HHD [total force], MMT [total], HHD [weight normalized], and HHD [norm referenced]) against the 2 dependent variables (STS [without hands] and STS [with hands]). These curves were used to determine cutoff points of the different KEF measures with their respective validity, sensitivity, and specificity. The ROC curve ROC curve acronym for receiver operating characteristic curve. A graphical method of assessing the characteristic of a diagnostic test. has sensitivity values along the y-axis and specificity values along the x-axis. A perfect cutoff point, one with 100% sensitivity and 100% specificity, would be located in the upper left-hand corner of the graph. The point closest to this location was considered the best cutpoint. Sensitivity and specificity values were determined from the x-axis and y-axis of this point, and these values were used in the accompanying data matrix to find the cutoff point value. Validity was described by the proportion of subjects correctly classified as able to succeed at STS, which corresponds to the area under the curve. (41) Results Descriptive statistics of the 4 KEF measures are presented in Table 1, grouped according to the subjects' ability versus inability to achieve standing (either without use of their hands or with use of their hands). For both categories, the values of the different KEF measures were higher for subjects who were able to complete the STS maneuver than for subjects who were unable to complete the STS maneuver. Zero-order correlation coefficients between the independent variables (KEF measures, age, sex, height, and weight) and the 2 STS variables are presented in Table 2. The coefficients of the different KEF measures correlated with STS performance were all significant (P<.001). They ranged from .652 to .708 for STS (without hands) and from .545 to .638 for STS (with hands). Although varying in magnitude, the coefficients between the KEF measures and STS performance were not found to differ by the Hotelling T analyses. None of the other measures (age, sex, height, or weight) were found to correlate with STS performance. With one exception, with use of multiple logistic regression (Tab. 3), we did not find any measure to add to the explanation of STS performance provided by the KEF measures. That exception was the additional contribution offered by weight to the explanation of STS (without hands) and STS (with hands) by HHD (total force). After accounting for weight, the correlation (R) of HHD (total force) with STS (without hands) was .662 and the correlation of HHD (total force) with STS (with hands) was .584. Cutoff points and the proportion of subjects who were correctly classified, as well as sensitivity and specificity, for the 4 KEF measures are presented in Table 4. Of the KEF measures, HHD (weight normalized) could be used to classify the highest proportion of subjects (.928 for STS [without hands] and .899 for STS [with hands]). The HHD (weight normalized) cutoff point for STS (without hands) was determined from the ROC curve (Fig. 1) to be 40.0% of body weight, with a sensitivity of 86.0% and a specificity of 91.2%. With the use of the upper extremities (STS [with hands]), the cutoff point decreased to 31.1% of body weight (Fig. 2), with a sensitivity of 78.1% and a specificity of 82.4%. [FIGURES 1-2 OMITTED] Discussion All of the KEF measures in our study were found to have moderate correlations with STS independence, which is in agreement with previously published data. (3,10,17-19,21-24) Because we found no significant difference between the various KEF measures in their ability to predict STS independence, we believe none can be advocated (as a measure) over another on the basis of correlations. On the basis of ROC curve analysis, however, HHD (weight normalized) appears to have a slight advantage. Forward logistic multiple regression Multiple regression The estimated relationship between a dependent variable and more than one explanatory variable. analysis demonstrated that use of body weight added to the correlation of STS (without hands) and STS (with hands) provided by HHD (total force) (Tab. 3). This relationship persisted with STS (with hands) as the dependent variable, we believe because this variable involves the use of the upper extremities, which can decrease the demand that body weight places on the knee extensor muscles Extensor muscles A group of muscles in the forearm that serve to lift or extend the wrist and hand. Tennis elbow results from overuse and inflammation of the tendons that attach these muscles to the outside of the elbow. Mentioned in: Tennis Elbow during STS performance. This finding shows the importance of taking body weight into consideration, and thus the possible advantage of the HHD (weight normalized) when interpreting performance of the knee extensor muscles. Our findings do not support taking the time to normalize KEF measurements with age- and sex-specific force measurements if prediction of STS performance is desired. For measures that are designed to predict function, cutoff points, in theory, can be used to identify problems and guide goal setting. There are, however, few functionally relevant cutoff points reported in the literature. Ikezoe et al (3) determined that a KEF cutoff point of 45.5% of body weight was needed for independent ambulation. Ploutz-Snyder et al (24) reported a torque value of 3.0 N*m/kg of body weight to be important for performance of several activities, including the STS maneuver. However, no cutoff points involving an absolute force measurement normalized to body weight (HHD [weight normalized]) have been published relative to the ability to do the STS maneuver. Bohannon (17) estimated an HHD (total force) cutoff point of 330 N and an MMT (total) cutoff point of 22 for independence in the STS maneuver without the use of the upper extremities. In our study, which involved more subjects in a different setting, we found cutoff points of 300 N for HHD (total force) and 20.5 for MMT (total). However, the HHD (weight normalized) cutoff points were consistently found to have the highest sensitivity, specificity, and correct classification proportions for both STS (without hands) and STS (with hands). The usefulness of the cutoff points can be illustrated with an example. If a patient is observed to be unable to stand from a standard armless chair (even when using the upper extremities) and the patient is known to have an HHD (weight normalized) value of 20.0%, we believe it is reasonable to say that the patient has a KEF impairment that might be responsible for the failure to do the STS maneuver because the cutoff point for STS (with hands) is 31.1%. We contend it is also reasonable to set a goal of 31.1% for HHD (weight normalized) if independence in STS is a goal. There are many variables that were not analyzed in our study that can have an effect on the ability to rise from a sitting position. Balance (18,19,42) and technique (18,19,28) have been described as influencing STS capabilities. Balance, which we did not quantify, in our view tends to correlate with muscle force, which .was measured in our study. Sensation and dizziness are other variables found to correlate with balance, (19,42) which we did not quantify in our study. Subjects were not restricted or instructed in a specific chair-rise technique. Other factors such as vision, (21,22) available range of motion, (21) joint pain, (9) and a history of falls (13) can affect the ability of patients to rise from a sitting position. We believe the most important factor contributing to the increased success of rising from a sitting position in STS (with hands) as compared with STS (without hands) is upper-extremity muscle force, which we also did not measure. Researchers, we contend, should take this variable into consideration in future research, especially when the upper extremities are used. Our data suggest that upper-extremity muscle force and training of the upper extremities might affect a person's success in rising from a chair. Conclusion Multiple measures of KEF are valuable for explaining STS performance. In our study, HHD measurements normalized to body weight were found to be the best predictor of STS independence. However, the generalization of these measures may be limited by the restriction of measurements to hospitalized adult patients. The KEF required of patients in other settings may vary slightly.
Table 1.
Mean (Standard Deviation) for Knee Extension Force Measurements
Associated With Differences in Stand-up Performance (a)
MMT HHD (Total)
Stand-up Performance (Total) (N)
STS (without hands): able 22.6 (2.4) 421.5 (153.0)
STS (without hands): unable 16.5 (3.7) 198.8 (106.9)
STS (with hands): able 21.3 (3.3) 366.2 (163.4)
STS (with hands): unable 15.3 (3.6) 166.8 (89.4)
HHD (Weight HHD (Norm
Stand-up Performance Normalized) (%) Referenced) (%)
STS (without hands): able 58.9 (20.6) 58.9 (19.9)
STS (without hands): unable 26.4 (11.4) 28.0 (14.0)
STS (with hands): able 50.7 (21.7) 51.1 (20.8)
STS (with hands): unable 22.0 (10.1) 23.6 (13.7)
(a) STS=sit-to-stand, MMT (total)=total manual muscle test score
for left and right knee extensors, HHD (total)=total hand-held
dynamometry force (in newtons) for left and right knee extensors,
HHD (weight normalized)=HHD (total)/body weight,
HHD (norm referenced)=HHD (total) normalized to age- and
sex-specific reference values.
Table 2.
Correlation of Independent Variables With Sit-to-Stand Performance (a)
STS (Without STS (With
Independent Hands) Hands)
Variable r (P) [r.sup.2] r (P) [r.sup.2]
MMT (total) .693 (.001) .480 .638 (.001) .407
HHD (total) .652 (.001) .425 .545 (.001) .297
HHD (weight
normalized) .708 (.001) .501 .582 (.001) .339
HHD (norm
referenced) .682 (.001) .465 .566 (.001) .320
Age -.054 (.583) .003 -.029 (.764) .001
Sex -.124 (.205) .015 .021 (.830) .000
Weight -.072 (.459) .005 -.107 (.274) .011
Height .079 (.416) .006 -.044 (.967) .000
(a) STS=sit-to-stand, MMT (total)=total manual muscle test score
for left and right knee extensors, HHD (total)=total hand-held
dynamometry force for left and right knee extensors, HHD
(weight normalized)=HHD (total)/body weight, HHD
(norm referenced)=HHD (total) normalized to age- and
sex-specific reference values.
Table 3.
Multiple Forward Logistic Regression Models for Prediction of
Sit-to-Stand Performance (a)
Predictors Coefficient Standard Odds
([beta]) Error Wald P Ratio 95% CI
Without Hands
HHD (total) 0.085 0.016 27.813 .000 1.088 1.055-1.123
Weight -0.024 0.007 11.220 .001 0.976 0.963-0.990
Constant -1.676 0.975 2.963 .085 0.187
With Hands
HHD (total) 0.084 0.018 21.277 .000 1.088 1.049-1.127
Weight -0.023 0.007 9.552 .002 0.978 0.964-0.992
(a) STS=sit-to-stand, HHD (total)=total hand-held dynamometry force
for left and right knee extensors, CI=confidence interval.
Table 4.
Receiver Operating Characteristic Curve Analysis of Force Measures
Against Sit-to-Stand Independence (a)
Dependent Cutoff Area Under
Variable Force Measure Point Curve
STS (without hands) MMT (total) 20.5 0.907
STS (without hands) HHD (total) (N) 300.3 0.888
STS (without hands) HHD (weight normalized) (%) 40.0 0.928
STS (without hands) HHD (norm referenced) (%) 39.7 0.898
STS (with hands) MMT (total) 18.5 0.878
STS (with hands) HHD (total) (N) 223.7 0.868
STS (with hands) HHD (weight normalized) (%) 31.1 0.899
STS (with hands) HHD (norm referenced) (%) 31.6 0.870
Dependent Sensitivity Specificity
Variable (%) (%)
STS (without hands) 88.0 82.5
STS (without hands) 82.0 84.2
STS (without hands) 86.0 91.2
STS (without hands) 81.6 82.5
STS (with hands) 75.3 79.4
STS (with hands) 76.7 76.5
STS (with hands) 78.1 82.4
STS (with hands) 76.4 76.5
(a) STS=sit-to-stand, MMT (total)=total manual muscle test score for
left and right knee extensors, HHD (total)=total hand-held dynamometry
force (in newtons) for left and right knee extensors, HD (weight
normalized)=HHD (total)/body weight, HHD (norm referenced)=HHD (total)
normalized to age- and sex-specific reference values.
* Ametek Test and Calibration Instruments, 8600 Sommerset Dr, Largo Largo, town (1990 pop. 65,674), Pinellas co., W Fla., on the Pinellas peninsula and the Gulf Coast, across the bay from Tampa; settled 1853, inc. 1905. It is a packing, canning, and shipping center in a citrus fruit and fishing area. , FL 33773. References (1) International Classification of Impairments, Disabilities and Handicaps. Geneva Geneva, canton and city, Switzerland Geneva (jənē`və), Fr. Genève, canton (1990 pop. 373,019), 109 sq mi (282 sq km), SW Switzerland, surrounding the southwest tip of the Lake of Geneva. , Switzerland: World Health Organization; 1980. (2) Bohannon RW. Sit-to-stand test for measuring performance of lower extremity muscles. Percept percept /per·cept/ (per´sept?) the object perceived; the mental image of an object in space perceived by the senses. per·cept n. 1. The object of perception. 2. Mot Skills. 1995;80:163-166. (3) Ikezoe T, Asakawa Y, Hazaki H, et al. Muscle strength and muscle endurance required for independent walking and in the elderly. Journal of Physical Therapy Science. 1997;9:19-22. (4) Guralink JM, Ferrucci L, Simonsick EM, et al. Lower extremity function in persons over the age of 70 years as a prediction of subsequent disability. N Engl J Med. 1995;332:556-561. (5) Campbell AJ, Borrie MJ, Spears GF. Risk factors for falls in a community-based prospective study of people 70 years and over. J Gerontol. 1989;44:M112-M117. (6) Severson MA, Smith GE, Tangalos EG, et al. Patterns and predictors of institutionalization Institutionalization The gradual domination of financial markets by institutional investors, as opposed to individual investors. This process has occurred throughout the industrialized world. in community-based dementia patients. J Am Geriatr Soc. 1994;42:181-185. (7) Mor V, Wilcox V, Williams R, Hins J. Functional transitions among the elderly: patterns, predictors, and related hospital use. Am J Public Health. 1994;84:1274-1280. (8) Manton KG. A longitudinal study longitudinal study a chronological study in epidemiology which attempts to establish a relationship between an antecedent cause and a subsequent effect. See also cohort study. of functional change and mortality in the United States United States, officially United States of America, republic (2005 est. pop. 295,734,000), 3,539,227 sq mi (9,166,598 sq km), North America. The United States is the world's third largest country in population and the fourth largest country in area. . J Gerontol. 1988;43:S153-S161. (9) Odding E, Valkenburg HA, Algra D, et al. Association of locomotor lo·co·mo·tor or lo·co·mo·tive adj. Of or relating to movement from one place to another. locomotor of or pertaining to locomotion. complaints and disability in the Rotterdam study The Rotterdam Study is a prospective, population-based cohort study. The aim of the Rotterdam Study is to investigate factors that determine the occurrence of cardiovascular, neurological, ophthalmological, endocrinological, and psychiatric diseases in elderly people. . Ann Rheum rheum (rldbomacm) any watery or catarrhal discharge. rheum n. A watery or thin mucous discharge from the eyes or nose. rheum any watery or catarrhal discharge. Dis. 1995;54:721-725. (10) Rikli RE, Jones J. Development and validation of a functional fitness test for community-residing older adults. Journal of Aging and Physical Activity. 1999;7:129-161. (11) Csuka M, McCarthy DJ. Simple method for measurement of lower extremity muscle strength. Am J Med. 1985;78:77-81. (12) Guralnik JM, Simonsick EM, Ferrucci L, et al. A short physical performance battery assessing lower extremity function: association with self-reported disability and prediction of mortality and nursing home admission. J Gerontol. 1994;49:M85-M94. (13) Hart D, Bowling A, Ellis M, Silman A. Locomotor disability an very elderly people: value of a programme for screening and provision of aids of daily living. BMJ BMJ n abbr (= British Medical Journal) → vom BMA herausgegebene Zeitschrift . 1990;301 (6745):216-220. (14) Lundgren-Lindquist B, Rundgren JA. Functional capacity of the elderly in Sweden. Int Disabil Stud. 1987;10:6-9. (15) Sonn U, Frandin K, Grimby G. Instrumental activities of daily living instrumental activities of daily living A series of life functions necessary for maintaining a person's immediate environment–eg, obtaining food, cooking, laundering, housecleaning, managing one's medications, phone use; IADL measures a related to impairments and functional limitations in 70-year-olds and changes between 70 and 76 years of age. Scand J Rehabil Med. 1995;27: 119-128. (16) Dawson D, Hendershot G, Fulton J. Aging in the Eighties: Functional Limitations of Individuals Age 65 and Over. Hyattsville, Md: National Center for Health Statistics National Center for Health Statistics (NCHS) is part of the Centers for Disease Control and Prevention (CDC), which is part of the United States Department of Health and Human Services. NCHS is the United States' principal health statistics agency. , Public Health Service; 1987; Advance Data From Vital and Health Statistics No. 133 (PHS (Personal Handyphone System) A TDMA-based cellular phone system introduced in Japan in mid-1995. Operating in the 1880-1930 MHz band, PHS uses microcells that cover an area only 100 to 500 meters in diameter, resulting in lower equipment costs but requiring more base ):87-1250. (17) Bohannon RW. Alternatives for measuring knee extension strength of the elderly at home. Clin Rehabil. 1998;12:434-440. (18) Schenkman M, Hughes MA, Samsa G, Studenski S. The relative importance of strength and balance by functionally impaired older individuals. J Am Geriatr Soc. 1996;44:1441-1446. (19) Alexander NB, Schultz AB, Warwick DN. Rising from a chair: effects of age and functional ability on performance biomechanics The study of the anatomical principles of movement. Biomechanical applications on the computer employ stick modeling to analyze the movement of athletes as well as racing horses. Biomechanics . J Gerontol. 1991;46:M91-M98. (20) Chiou IL, Burnett CN. Values of activities of daily living: a survey of stroke patients and their home therapists. Phys Ther. 1985;65:901-906. (21) Brown M, Sinacore DR, Host HH. The relationship of strength to function in the older adult. Gerontol A Biol Sci Med Sci. 1995;50:55-59. (22) Tinetti ME, Ginter SF. Identifying mobility dysfunctions in elderly patients: standard neuromuscular examination or direct assessment? JAMA JAMA abbr. Journal of the American Medical Association . 1988;259:1190-1193. (23) Wretenberg P, Aborelius UP. Power and work produced in different leg muscle groups when rising from a chair. Eur J Appl Physiol. 1994;68:413-417. (24) Ploutz-Snyder LL, Manini T, Ploutz-Snyder RJ, Wolf DA. Functionally relevant thresholds of quadriceps femoris Noun 1. quadriceps femoris - a muscle of the thigh that extends the leg musculus quadriceps femoris, quadriceps, quad extensor, extensor muscle - a skeletal muscle whose contraction extends or stretches a body part strength. J Gerontol A Biol Sci Med Sci. 2002;57:B144-B152. (25) Van der Ploeg RJO RJO Remote Job Output , Oosterhuis HJHG, Reuvekamp J. Measuring muscle strength. J Neurol. 1984;231:200-203. (26) Bohannon RW. Reference values for extremity muscle strength obtained by hand-held dynamometry dy·na·mom·e·ter n. Any of several instruments used to measure mechanical power. [French dynamomètre : Greek dunamis, power; see dynamic + -mètre, -meter. from adults aged 20 to 79. Arch Phys Med Rehabil. 1997;78:26-32. (27) Wretenberg P, Lindberg F, Arborelius UP. Effects of arm rests and different ways of using them on hip and knee load during rising. Clin Biomech. 1993;8:95-101. (28) Hughes MA, Weiner DK, Schenkman ML, et al. Chair rise strategies in the elderly. Clin Biomech. 1994;9:178-192. (29) Rodosky MW, Andriacchi TP, Andersson GBJ GBJ Jersey (International Auto Identification) . The influence of chair height on lower limb mechanics during rising. J Orthop Res. 1989;7:266-271. (30) Finlay OE, Bayles TB, Milling J. Effects of chair rise design, age and cognitive status on mobility. Age Aging. 1983;12:329-335. (31) Weiner DK, Long R, Hughes MA, et al. When older adults face the chair-rise challenge: a study of chair height availability and height-modified chair-rise performance in the elderly. J Am Geriatr Soc. 1993;41:6-10. (32) Functional Independence Measure. In: Guide to the Uniform Data Set for Medical Rehabilitation. Version 5.0. Buffalo, NY: Uniform Data System for Medical Rehabilitation; 1996. (33) Bohannon RW. Intertester reliability of hand-held dynamometry: a concise summary of published research. Percept Mot Skills. 1999;88: 899-902. (34) Wadsworth CT, Krishnan R, Sear sear 1 v. seared, sear·ing, sears v.tr. 1. To char, scorch, or burn the surface of with or as if with a hot instrument. See Synonyms at burn1. 2. M, et al. Intrarater reliability of manual muscle testing and hand-held dynametric muscle testing. Phys Ther. 1987;67:1342-1347. (35) Bohannon RW, Saunders N. Hand-held dynamometry: a single trial may be adequate for measuring muscle strength in healthy individuals. Physiotherapy Canada. 1990;42:6-9. (36) Hislop HJ, Montgomery J. Daniels and Worthingham's Muscle Testing: Techniques of Manual Examination. 6th ed. Philadelphia, Pa: WB Saunders Co; 1995:208-210. (37) Medical Research Council. Aids to the Examination of the Peripheral Nervous System peripheral nervous system: see nervous system. . London, England: HMSO HMSO (in Britain) Her (or His) Majesty's Stationery Office HMSO n abbr (BRIT) (= His (or Her) Majesty's Stationery Office) → distribuidor oficial de las publicaciones del gobierno del Reino Unido ; 1976:1. (38) SYSTAT 10.0 for Windows. Chicago Ill: SPSS Inc; 1999. (39) SPSS 10.0 for Windows. Chicago Ill: SPSS Inc; 2000. (40) Portney LG, Watkins MP. Foundations of Clinical Research: Applications to Practice. 2nd ed. Upper Saddle River Saddle River may refer to:
In 1913, law professor Dr. ; 2000:98-101. (41) Cantor SB, Sun CC, Tortolero-Luna G, et al. A comparison of c/b ratios from studies using receiver operating characteristic curve receiver operating characteristic curve see roc curve. analysis. J Clin Epidmiol. 1999;52:885-892. (42) Lord SR, Murray SM, Chapman K, et al. Sit-to-stand performance depends on sensation, speed, balance, and psychological status in addition to strength in older people. J Gerontol A Biol Sci Med Sci. 2002;57:M539-M543. O Eriksrud, PT, MSPT MSPT Master of Science in Physical Therapy MSPT Morning Star Polytechnic MSPT Maintenance Support Product Team MSPT Male Straight Pipe Thread MSPT Microsoft Power Toys , is Physical Therapist, Wilton Physical Therapy, Wilton, Conn. RW Bohannon, PT, EdD, NCS (Network Call Signaling) CableLabs version of MGCP. See MGCP/MEGACO. NCS - Network Computing System: Apollo's RPC system used by DEC and Hewlett-Packard.The protocol has been adopted by OSF. , FAHA FAHA Florida Air Hockey Association FAHA Fellow of the American Heart Association FAHA Florida Association of Homes for the Aging FAHA Fellow of the Australian Academy of the Humanities FAHA Finnish American Heritage Association , is Professor, Department of Physical Therapy, School of Allied Health, University of Connecticut The University of Connecticut is the State of Connecticut's land-grant university. It was founded in 1881 and serves more than 27,000 students on its six campuses, including more than 9,000 graduate students in multiple programs. UConn's main campus is in Storrs, Connecticut. , 358 Mansfield Rd, U-2101, Storrs, CT 06250-2101 (USA) (RICHARD.BOHANNON@UCONN.EDU), and Senior Scientist, Institute of Outcomes Research and Evaluation, Hartford Hospital Hartford Hospital is an acute care hospital located in the South End of Hartford, Connecticut. The hospital was formed in 1854 after the State of Connecticut granted a charter for the Formation of Hartford Hospital following a boiler explosion and resulting fire at the Fales and , Hartford, Conn. Address all correspondence to Dr Bohannon at the first address. Dr Bohannon provided concept/idea/research design, project management, subjects, facilities/equipment, and institutional liaisons. Both authors provided writing and data collection and analysis. The study was approved by the Institutional Review Committee of Hartford Hospital. The Connecticut Chapter of the American Physical Therapy Association The American Physical Therapy Association (APTA) is a national professional organization representing more than 66,000 members. Its goal is to foster advancements in physical therapy practice, research, and education. supported the study. This article was submitted April 30, 2002, and was accepted February 4, 2003. |
|
||||||||||||||||||

Printer friendly
Cite/link
Email
Feedback
Reader Opinion