Now one instrument can test high- & low-shear viscosity.Consistent melt viscosity is an important criterion for achieving product uniformity. Unfortunately, rheological rhe·ol·o·gy n. The study of the deformation and flow of matter. rhe o·log testing can be time-consuming and labor-intensive, and one instrument is often not sufficient to test the full range of shear rates desired. A new measurement device is said to solve this long-standing problem by making it faster and easier to check resin viscosity over a wide range of shear rates. For routine QC work, capillary rheometers are widely used to assess resin processability. They are also used for R&D to qualify which material best fits a process or application. However, a conventional single-bore/single-die capillary rheometer rhe·om·e·ter n. An instrument for measuring the flow of viscous liquids, such as blood. often requires making multiple measurements that can take as long as half a day. A new triple-bore capillary rheometer from Goettfert of Rock Hill, S.C., reportedly provides a variety of flow measurements in a single test within half an hour. This instrument makes it easy to conduct normally tedious tests like Bagley-corrections, which correlate with elongational viscosity or melt strength, or Mooney viscosity measurements to determine slip velocity. Stretching the speed range Goettfert's new Rheograph 6000 uses microprocessor-controlled servo An electromechanical device that uses feedback to provide precise starts and stops for such functions as the motors on a tape drive or the moving of an access arm on a disk. hydraulics hydraulics, branch of engineering concerned mainly with moving liquids. The term is applied commonly to the study of the mechanical properties of water, other liquids, and even gases when the effects of compressibility are small. to push capillary rheometry into new territory. Traditionally, the linear flow behavior of polymer melts at low shear rates has been characterized with rotational rheometers, while the nonlinear shear-thinning region at high shear rates is measured with capillary rheometers, which typically have electromechanical The use of electricity to run moving parts. Disk drives, printers and motors are examples. Electromechanical systems must be designed for the eventual deterioration of moving components that wear over time. The first TVs were electromechanical systems (see video/TV history). drives. According to according to prep. 1. As stated or indicated by; on the authority of: according to historians. 2. In keeping with: according to instructions. 3. Goettfert sources, there has been a need to broaden the speed range of capillary rheometers to cover both high and low shear rates. The new instrument accomplishes that with a servo-hydraulic drive system that combines a high-pressure cylinder with a low-pressure cycle and high-precision control. Rheograph 6000 uses a microprocessor-controlled stepper motor A motor that rotates in small, fixed increments and is used to control the movement of the access arm on a disk drive. Contrast with voice coil. (hardware) stepper motor to actuate the high-load hydraulic system Noun 1. hydraulic system - a mechanism operated by the resistance offered or the pressure transmitted when a liquid is forced through a small opening or tube . The servo-hydraulic drive offers a dynamic speed range of 1:400,000 as compared with 1:20,000 when using a single-bore capillary rheometer. Minimum piston speeds of 0.0001 mm/sec can be obtained for very low shear. For ultra-high shear rates, the maximum ram speed is 40 mm/sec, twice that of the older Rheograph 2003 model. The new instrument also offers a maximum force of 13,500 lb, three times higher than that of its predecessor. Why three bores are better The Rheograph 6000 utilizes a new measuring cell concept, which consists of a triple-bore, triple-die system enclosed in a single barrel. According to Goettfert, this development expands the range even farther. Parallel operation of three dies of 0.5 to 3 mm diam. gives a shear-rate ratio larger than 1:500. As a result, a total shear range of eight decades can be achieved, compared with three decades typically achievable with a single-bore unit. According to Goettfert, the triple-bore/triple-die configuration offers two possibilities. Within a single experiment, the shear rate range can be extended by using different die-orifice diameters, or the formerly time-consuming triple-point Bagley-correction can be performed in one experiment using a set of capillaries with the same orifice orifice /or·i·fice/ (or´i-fis) 1. the entrance or outlet of any body cavity. 2. any opening or meatus.orific´ial aortic orifice diameter but different lengths. Also, the extrudate swell as a function of shear rate can be determined to provide a measure of the melt's viscoelastic Adj. 1. viscoelastic - having viscous as well as elastic properties natural philosophy, physics - the science of matter and energy and their interactions; "his favorite subject was physics" behavior. Elastic parameters such as the first normal stress difference can be estimated by the unit's software. Optional die-swell and melt tensile tests are possible with the aid of the company's Rheotens elongational tester. The Rheograph 6000 sells for around $100,00-150,000. |
|
||||||||||||||||||||

o·log
Printer friendly
Cite/link
Email
Feedback
Reader Opinion