NIST establishes reference for measuring frequency dependence of capacitors.Recent work at NIST (National Institute of Standards & Technology, Washington, DC, www.nist.gov) The standards-defining agency of the U.S. government, formerly the National Bureau of Standards. It is one of three agencies that fall under the Technology Administration (www.technology. could lead to improvements in the capacitance calibration services at NIST by a factor of three or four. The primary maintenance standard for NIST capacitance calibrations consists of a bank of four 10 pF fused-silica standards (referred to as the Farad Bank) which are maintained in an oil bath at 25 [degrees]C. The Farad Bank is calibrated cal·i·brate tr.v. cal·i·brat·ed, cal·i·brat·ing, cal·i·brates 1. To check, adjust, or determine by comparison with a standard (the graduations of a quantitative measuring instrument): twice a year against the calculable cal·cu·la·ble adj. 1. That can be calculated or estimated: calculable odds. 2. Readily relied on; dependable: a calculable assistant. capacitor at a frequency of 1592 Hz. The calculable capacitor provides an absolute determination of capacitance in terms of length only and is the ultimate reference for all impedance measurements in the United States United States, officially United States of America, republic (2005 est. pop. 295,734,000), 3,539,227 sq mi (9,166,598 sq km), North America. The United States is the world's third largest country in population and the fourth largest country in area. . Until recently, there was a lack of a well-characterized reference capacitor over the audio frequency range, resulting in large assigned uncertainties for capacitance calibrations to account for the uncharacterized frequency dependence of the Farad Bank. The value of a standard capacitor may vary slightly with frequency because the imperfect medium between its electrodes has varying degrees of dielectric relaxation Dielectric relaxation is the momentary delay (or lag) in the dielectric constant of a material. This is usually caused by the delay in molecular polarization with respect to a changing electric field in a dielectric medium (e.g. inside capacitors or between two large conducting surfaces). over the frequency range and the leads and electrodes of the capacitor have residual inductance inductance, quantity that measures the electromagnetic induction of an electric circuit component; it is a property of the component itself rather than of the circuit as a whole. . Using a combination of a 1 pF cross capacitor that has negligible frequency dependence due to electrode surface films and a 10 pF nitrogen dielectric dielectric (dī'ĭlĕk`trĭk), material that does not conduct electricity readily, i.e., an insulator (see insulation). A good dielectric should also have other properties: It must resist breakdown under high voltages; it should not capacitor with a very small residual inductance as references, NIST staff have measured the frequency dependence of two 10 pF transportable fused-silica capacitors from 50 Hz to 20 kHz. The relative standard uncertainties determined at 400 Hz and 100 Hz (0.15 X 1[0.sup.-6] and 0.32 X 1[0.sup.-6], respectively) are smaller than the uncertainties previously assigned to frequency dependence at these frequencies by a factor of five. This will lead to improvements in the capacitance calibration services at NIST by a factor of three or four. The results were presented in an invited talk in August at the 2003 National Conference of Standards Laboratories; an archival paper describing the work has been published in the September issue of Review of Scientific Instruments Review of Scientific Instruments is a journal published monthly by the American Institute of Physics. Its area of interest is scientific instruments, apparatus, and techniques. . NIST plans to transfer the frequency dependence data to the Farad Bank and other reference capacitance standards, so that in the near future, improved capacitance calibrations will be available from NIST for the entire audio frequency range. CONTACT: Jerry Stenbakken, (301) 975-2440; gerard.stenbakken@nist.gov. General Developments Inquiries about News Briefs, where no contact person is identified, should be referred to the Managing Editor, Journal of Research, National Institute of Standards, and Technology, Building 101, Room E215, Gaithersburg, MD 20899-2500; telephone: (301) 975-3577. |
|
||||||||||||||

Printer friendly
Cite/link
Email
Feedback
Reader Opinion