Liquiline M simplicity comes as standard.Life is complicated enough without technology adding to the day-to-day complexity of your plant. That's why Endress+Hauser's Liquiline M is a pH/conductivity transmitter with a guiding philosophy at its heart: to make life simpler.Why should dials be difficult to see? Why shouldn't an instrument be its own technical manual? The Liquiline M addresses both questions, with a large plain text display that shows the measured value in sensibly-sized figures 22mm high. It is also easy to use, thanks to its new Navigator button--a twisting dial complete with an integrated 'enter' key. The Navigator takes you through parameter setting, servicing, diagnosis and predictive maintenance Predictive maintenance (PdM) techniques help determine the condition of in-service equipment in order to predict when maintenance should be performed. This approach offers cost savings over routine or time-based preventive maintenance because tasks are performed only when , with plain text format replacing bulky manuals. Indeed, Endress+Hauser has thought of every permutation One possible combination of items out of a larger set of items. For example, with the set of numbers 1, 2 and 3, there are six possible permutations: 12, 21, 13, 31, 23 and 32. (mathematics) permutation - 1. and feature you might need, including: Predictive maintenance functions, offering immediate error signalling (through an output and red LED alarm) in case of function loss--Modular construction to configure Liquiline M to your needs, allowing a single transmitter to be used for either pH or conductivity measurement--A choice of corrosion-resistant plastic or stainless steel stainless steel: see steel. stainless steel Any of a family of alloy steels usually containing 10–30% chromium. The presence of chromium, together with low carbon content, gives remarkable resistance to corrosion and heat. housings--Options to install in both plants and panels, in safe or hazardous areas--Digital and analogue transmitter options. Liquiline M also complies with international safety standard SIL See safety integrity level. 1. SIL - "SIL - A Simulation Language", N. Houbak, LNCS 426, Springer 1990. 2. SIL - SNOBOL Implementation Language. Intermediate language forming a virtual machine for the implementation of portable interpreters. 2 for simple integration into Safety Instrumented Systems A system that protects a manufacturing or operating process. Conforming to the IEC 61511 or 61508 standards, such a system is designed to shut itself down or change to a reduced operational state in the event of failure or hazardous situation. . It is designed for all standard bus systems such as HART, PROFIBUS (PROcess FIeldBUS) An industrial control network used for factory automation, process control, motion control and safety networks. Using a master/slave architecture, specialized "Profiles" are used to support each of these areas. and FOUNDATION Fieldbus FOUNDATION fieldbus is an all-digital, serial, two-way communications system that serves as the base-level network in a plant or factory automation environment. Developed and administered by the Fieldbus Foundation. , and is integrated simply into new and existing systems. Coupled with Memosens technology, sensor-specific data is automatically transported between sensor and transmitter. Since critical data (for example, calibration data and sensor limits) is also stored in the transmitter, this means simple commissioning and maintenance with pre-calibrated sensors. Contract Endress & Hauser on tel: 0161 286 5000 or visit www.uk.endress.com |
|
||||||||||||||||||||

Printer friendly
Cite/link
Email
Feedback
Reader Opinion