Let's keep M8A1 alarmed.YAAAHHHH! I'M SO ALARMED BY THIS CHEMICAL THREAT! EVERYONE IN THEIR JSLIST JSLIST Joint Service Lightweight Integrated Suit Technology ! OUR M8 HAS COME THROUGH FOR US! PMCS PMCS PMC Sierra (stock symbol) PMCS Project Management Control System PMCS partial mission-capable, supply (US DoD) PMCS Preventive Maintenance Checks & Services PMCS Professional Military Comptroller School If your M8A1 has been locked in a cabinet for weeks, the M43A1 detector probably won't reach the green zone on its meter in 15 minutes during PMCS. Give it longer to run. Sometimes the M43A1 just has to run until the cell assembly clears itself, which may take longer than 15 minutes. JUST GIVE ME SOME TIME TO STABILIZE. I'VE BEEN SITTING A LONG TIME. If the M8A1 has been stored for a long period, also check that the binding posts can be depressed. Corrosion could have frozen them. Then you can't connect the detector to the alarm. Get frozen binding posts replaced. IF YOUR M8A1 CHEMICAL AGENT ALARM DOESN'T STAY ALARMED, YOU COULD HAVE ALARMING RESULTS. HERE ARE A FEW WAYS NBC NBC in full National Broadcasting Co. Major U.S. commercial broadcasting company. It was formed in 1926 by RCA Corp., General Electric Co. (GE), and Westinghouse and was the first U.S. company to operate a broadcast network. NCOS (Network Computer Operating System) The operating system in Oracle's network computer. See Network in a Box. AND OPERATORS CAN KEEP THE M8A1 SNIFFING FOR DANGER. Look for cracks in the flowmeter See flow meter. and a missing gasket at the top of the flowmeter. That's Item 3 in the PMCS; If it's cracked; the flowmeter won't pass its test. Remember your NBC NCO NCO abbr. noncommissioned officer NCO noncommissioned officer NCO n abbr (Mil) (= noncommissioned officer) → Uffz. needs to install the air outlet filter if you're operating the M8A1 inside. Because of its radioactive source, the M8A1 puts out radioactive particles. If the flowmeter is OK but the M43A1 still can't get the ball into the green zone, make sure the air outlet nut is tight and the case main seal, air filter plug seal, and air inlet seal are good. Turn the air outlet nut clockwise with your fingers until it's hand-tight. Report bad seals. Still no luck? The air outlet cap may be leaking. Put a new cap on or seal the outlet with your finger (wear gloves to do that). Still doesn't pass? Check that the rainshield adapter is tight. If all that doesn't fix the problem, it's time for that M8A1 to go to support. Remember, never run the M43A1 longer than 30 seconds with the air outlet sealed. Otherwise, heat destroys its circuitry. Another never is to never leave a test paddle in longer than two minutes and never try more than two paddles. If you ignore those rules, the detector cell is contaminated and it takes a l-o-n-g time to purge it. If the M43A1 doesn't respond to tests; its toggle switch may be turned off. The switch should point out, away from the pump module. Flip it out if necessary. In the field When you connect the detector to the alarm, tie off nine inches of wire at the loop on the side of the M43A1. If the loop is missing, wrap the wire around the handle. That keeps the wire from being jerked out if someone trips on it. Warn your unit before you rest the alarm. Otherwise, you could come back to your unit and find everyone dressed in chemical gear ... and saying unkind things about you. OOPS! I SHOULD HAVE TOLD YOU GUYS I WAS TESTING. Radiation Rules BECAUSE THE M3A1 HAS A RADIOACTIVE SOURCE, YOU HAVE TO FOLLOW THE RADIATION RULES ... * Keep the M43A1 locked in a metal cabinet or caged area with a radioactive caution sticker posted on the door. If you don't have a sticker, see your safety officer. * Have the M43A1 wipe tested for radiation leaks by support every 12 months. Your M43A1 detector will be non-mission capable if there's not a record of a current wipe test. And the detector cell must have radiation warning labels stuck to it, as well as a sticker showing when it was wipe tested. * Once the outlet filter is clogged or damaged, it must be placed in a sealed plastic bag and given to your local RPO RPO Recruitment Process Outsourcing RPO Recovery Point Objective (disaster recovery) RPO Royal Philharmonic Orchestra RPO Rochester Philharmonic Orchestra RPO Representative Poetry Online RPO Railway Post Office . See Para 4-13 in the M8A1's TM 3-6665-312-12&P for details. IF YOU DON'T FOLLOW THESE RULES, YOU COULD FIND YOURSELF IN HOT WATER WITH ALL SORTS OF GOVERNMENT AGENCIES. HEY, WHAT'S GOING ON What's Going On is a record by American soul singer Marvin Gaye. Released on May 21, 1971 (see 1971 in music), What's Going On reflected the beginning of a new trend in soul music. ? I WISH I KNEW WHICH SHIPPING CONTAINER TO USE TO SHIP THIS BRADLEY ENGINE STATESIDE state·side adj. 1. Of or in the continental United States. 2. Alaska Of or in the 48 contiguous states of the United States. adv. Informal 1. . YOU'RE IN LUCK! I JUST SAW SOME INFO ABOUT THIS AT THE NEW PS WEBPAGE. THE ONE CALLED HOT TOPICS. HERE, LEMME The Lemme is a 35 km torrent, a right tributary of the Orba, which flows through the Province of Alessandria in northern Italy. Its source is near Monte Calvo; from there it passes through the communes of Fraconalto, Voltaggio, Carrosio, Gavi, San Cristoforo, Francavilla SHOW YOU! LET'S SEE IF I GOT THIS URL URL in full Uniform Resource Locator Address of a resource on the Internet. The resource can be any type of file stored on a server, such as a Web page, a text file, a graphics file, or an application program. TYPED IN CORRECTLY ... https://www.logsa.army.mil/psmag/topics.cfm YEP ... HIT ENTER, AND ... AHA! |
|
||||||||||||||||||

Printer friendly
Cite/link
Email
Feedback
Reader Opinion