Legionella--an environmental issue and concern.William E. Pearson II, C.W.T., Association of Water Technologies The discovery and identification of Legionella bacteria followed an outbreak of illness reported to the Pennsylvania health authority that resulted in 34 deaths among 231 afflicted people. The outbreak occurred in 1976 around a Philadelphia hotel that was host to an American Legion Convention--thus, the illness became known as Legionnaires' disease (LD). Legionnaires' disease is a form of pneumonia, and the microorganism responsible for the disease is a naturally occurring water bacterium. Legionella is found in lakes, streams, rivers, groundwaters, and even some soils. It can escape water plant chlorination treatment and is thus found in domestic (potable) water plumbing and other water-use systems (e.g., commercial, industrial, process, and HVAC systems). In many of these systems, it finds conditions that favor a disease risk. Outbreaks of legionellosis are often blamed on the air conditioning (cooling tower) systems of large buildings and commercial or industrial complexes. It is just as well established, however, that another common habitat for the disease-producing bacteria is in the hot-water and potable-plumbing systems of these same buildings. New research shows that residential hot-water pipes also can be a source of the bacteria (and the disease). A recent U.S. Environmental Agency (U.S. EPA)-sponsored study sampled for Legionella in the residential water systems of 21 Legionnaires' disease patients and linked five of the water systems to the disease bacteria. Several conditions and factors must occur for Legionella to cause disease; sufficient quantity of the bacteria, a virulent form of the bacteria, or both must be made transmittable to a susceptible host. Transmission occurs when a host inhales tiny water droplets (mists or aerosols) containing Legionella or aspirates Legionellaladen water during the drinking (swallowing) process. These transmission routes provide entry of the infectious Legionella into the deeper parts of the lungs, where they take over and promote the pneumonia. Legionella bacteria grow well and amplify in warm water environments and systems that provide favorable conditions for bacterial growth and the formation of biofilm. The optimum temperature range for growth is 90 to 105 degrees Fahrenheit. The subsequent use or release of water from systems harboring Legionella, (i.e., through faucets, shower sprays, humidifying devices, aerosolizing devices, or other operational spray or drift mechanisms), may transmit the potential disease-causing bacteria to susceptible hosts. Fortunately, less than 5 to 6 percent of the general population are considered to be susceptible hosts, at greatest risk of contracting Legionnaires' disease upon exposure to the bacteria. People considered at high risk include the elderly, the very young, and those with underlying health problems such as chronic obstructive pulmonary disease (COPD), diabetes, congestive heart failure, and sickle cell anemia. Patients who are taking corticosteroids or other immunosuppressant drugs, who are undergoing cancer therapy or organ transplantation, or who have conditions or diseases that impair the immune system (such as AIDS), asthma, or other chronic illnesses, are particularly vulnerable. Nosocomial (hospital-acquired) cases of Legionnaires' disease are a natural concern within the health care community. The potable-hot-water plumbing systems present a favorable habitat for Legionella and pose an associated disease risk to the large at-risk population within a health care facility. Thus, a major emphasis is placed on the risk assessment, control, and management of these systems and their associated water-disseminating equipment or systems. Accordingly, the Joint Commission on Accreditation of Healthcare Organizations (JCAHO) issued a standard that became effective January 1, 2001. Standard (EC1.7) requires each JCAHO-accredited facility to have in place a management program to "reduce the potential for organizational-acquired illness." It holds the health care facility responsible for "managing pathogenic biological agents in cooling towers, domestic hot water, and other aerosolizing water systems"--Legionella among others. It is estimated that Legionella is responsible for 15,000 to 30,000 of the 600,000 pneumonia cases that require hospitalization each year in the United States. Specialized laboratory tests are necessary to confirm Legionnaires' disease and, unfortunately, may not be available in many hospitals. Therefore, the disease remains largely undiagnosed or diagnosed without confirmation and subsequently goes unreported. Legionella is and should be considered an environmental health issue. The Association of Water Technologies (AWT) has recently released an update to its comprehensive document on Legionella and Legionnaires' disease. The document is available as a free download from the AWT Web site at www.awt.org. |
|
||||||||||||||||

Printer friendly
Cite/link
Email
Feedback
Reader Opinion