Electrocardiographic artifacts.A 34-year-old nurse complained of recurrent attacks of palpitations in the past 2 months. The palpitations were not related to any specific event or physiological changes. Twenty-four-hour ambulatory electrocardiographic monitoring ambulatory electrocardiographic monitoring Holter monitoring, see there of her cardiac rhythm using a Holter recorder did not reveal any arrhythmias, even though she reported several attacks of palpitations during the recording. The electrocardiogram electrocardiogram /elec·tro·car·dio·gram/ (-kahr´de-o-gram?) a graphic tracing of the variations in electrical potential caused by the excitation of the heart muscle and detected at the body surface. (ECG ECG electrocardiogram. ECG abbr. 1. electrocardiogram 2. electrocardiograph ECG Also called an electrocardiogram, it records the electrical activity of the heart. ) in Figure 1 was recorded following an emotionally stressful period and when she complained of having palpitations. The patient was alert at the time, and her blood pressure was normal. [FIGURE 1 OMITTED] QUESTIONS 1. The interpretation of the ECG is which of the following? a. supraventricular tachycardia b. ventricular tachycardia c. atrial flutter with 1:1 atrioventricular conduction d. ventricular flutter e. none of the above 2. Artifact may be caused by which of the following? a. muscle tremors b. Parkinson's disease c. poor skin-electrode contact d. electrical interference e. errors in electrode position f. any of the above 3. Electrocardiographic electrocardiographic emanating from or pertaining to electrocardiography. electrocardiographic monitoring maintenance of a more or less continuous surveillance of a patient's cardiac status by means of electrocardiography. artifacts artifacts see specimen artifacts. that mimic ventricular arrhythmias may result in which of the following? a. intravenous antiarrhythmic therapy b. the implantation of cardiac devices c. blood transfusions d. cardiac catheterizations e. any of the above ANSWERS 1. e. none of the above The ECG represents a pseudo-arrhythmia due to artifacts. Two clues direct you to the correct interpretation. The first clue reveals sinus rhythm in lead II. The normal appearance of the complexes in lead II is a result of the cancellation of artifacts and not because of a transient return to normal rhythm. The second clue is that most of the leads show sharp deflections that are regular and at the same intervals as those of the R-R cycles in lead II. An example can be seen in Figure 2, where an enlargement of leads II and [V.sub.3] (taken from Figure 1) reveals "X" marks above the "tips" of the QRS complexes. [FIGURE 2 OMITTED] The native rhythm has been altered by artifacts, which are revealed as small pointed deflections on the "tips" of the QRS complexes. An artifact may be classified as a pseudo-arrhythmia or a nonarrhythmia. In this case, the artifact has the appearance of an arrhythmia. However, artifacts may not resemble an arrhythmia, but nevertheless can alter the configuration of the native underlying rhythm. This altered configuration would occur with misplaced mis·place tr.v. mis·placed, mis·plac·ing, mis·plac·es 1. a. To put into a wrong place: misplace punctuation in a sentence. b. electrodes and is considered to be a nonarrhythmic artifact. Artifacts can be found in any setting where electrocardiographic monitoring information is stored, which includes Holter monitoring, continuous bedside ECG monitoring, or use of event recorders. 2. f. any of the above Muscle tremors may appear as rapid variations in the baseline that may be either coarse or fine and mimic atrial flutter or a runaway pacemaker. (1) Tremors that reflect fine artifacts can be seen with Parkinson's disease. Artifacts should be considered initially when sudden changes occur during an ECG recording in a patient with Parkinson's disease or muscle tremors. The artifacts related to Parkinson's disease are more prominent in the limb leads and represent the action potentials of active striated muscles. This active movement also occurs in disoriented dis·o·ri·ent tr.v. dis·o·ri·ent·ed, dis·o·ri·ent·ing, dis·o·ri·ents To cause (a person, for example) to experience disorientation. Adj. 1. patients who cannot relax. (2) The effects of upper extremity tremor may be minimized by having patients sit on their hands during the ECG recording. (3) Poor skin-electrode contact is corrected by pressing on the electrode to ensure better contact. If poor skin-electrode contact persists, the electrodes should be changed. Current best-practice standards call for cleaning the skin with alcohol to remove skin oils before electrode placement and/or shaving the area if necessary. (4) Electrical interference may produce a rhythm that has regular sawtooth peaks and is referred to as 60-cycle alternating current (AC) interference. This artifact, which was common in the past, occurs less often with newer equipment. ECG cable wires should not cross other electrical wires such as transducer cables or the line of the call light. Other electrical sources such as electric beds, lighting fixtures, ventilators, or electrical wiring may generate artifacts (even when not in use). Unplugging the surrounding electrical equipment may be necessary to eliminate 60-cycle AC artifacts. Finally, moving the patient to a different location may alleviate the problem. (3) Proper grounding initially can prevent many of the electrical artifacts. Errors in electrode placement can alter the interpretation; as a result, appropriate therapy may be jeopardized. (2) If the precordial lead [V.sub.1] is misplaced by 1 intercostal space, the morphology of the QRS complex may be altered and ventricular tachycardia could be misinterpreted as supraventricular tachycardia. (4,5) Practitioners should be familiar with the routine placements of electrode leads on the chest. Begin at the top of the manubrium manubrium /ma·nu·bri·um/ (mah-noo´bre-um) pl. manu´bria [L.] a handle-like structure or part, such as the manubrium of the sternum. at the jugular jugular /jug·u·lar/ (jug´u-lar) 1. cervical. 2. pertaining to a jugular vein. 3. a jugular vein. jug·u·lar adj. notch and palpate pal·pate v. To examine by feeling and pressing with the palms of the hands and the fingers. pal·pa tion n. inferiorly until the angle of Louis is felt. The angle of Louis (sternal angle) represents the prominent border between the sternum sternum: see rib. and manubrium. Directly to the right of the angle of Louis is the second rib. The space below the second rib is the second intercostal space. By palpating inferiorly, one can locate the fourth intercostal space for placement of lead [V.sub.1] to the right and [V.sub.2] to the left of the sternum. The other chest leads are then easily located; lead [V.sub.4] at the fifth intercostal space to the left of the midclavicular line and [V.sub.3] midway on a line between [V.sub.2] and [V.sub.4]. Lead [V.sub.5] is located at the same level as [V.sub.4], but at the anterior axillary line, and [V.sub.6] is on the horizontal level of [V.sub.4] and [V.sub.5] at the midaxillary line. The common practice of "eyeballing" precordial lead placements is not acceptable and does not come close to the best-practice standards! 3. e. any of the above It is obvious from the ECG in Figure 1 that artifacts can be misinterpreted as ventricular tachycardia. Similar examples can be found in textbooks; however, reports on ECG artifacts in the literature are rare. (6-8) Nevertheless, it is noteworthy that a report published in the New England Journal of Medicine The New England Journal of Medicine (New Engl J Med or NEJM) is an English-language peer-reviewed medical journal published by the Massachusetts Medical Society. It is one of the most popular and widely-read peer-reviewed general medical journals in the world. describes 12 patients in whom diagnostic or therapeutic interventions were initiated as a direct result of misdiagnosed artifacts; for example, monomorphic monomorphic /mono·mor·phic/ (-mor´fik) existing in only one form; maintaining the same form throughout all developmental stages. mon·o·mor·phic or mon·o·mor·phous adj. 1. ventricular tachycardia in 5 patients and polymorphic ventricular tachycardia in 7 patients. (6) The clinical consequences of a misdiagnosis mis·di·ag·no·sis n. pl. mis·di·ag·no·ses An incorrect diagnosis. mis·di ag·nose are potentially ominous, because the pharmacological interventions and the precordial thumps performed in these patients are superfluous and potentially harmful. A misdiagnosis of torsades de pointes Torsades de pointes or torsades is a French term that literally means "twisting of the points". It was first described by Dessertenne in 1966[1] and refers to a specific variety of ventricular tachycardia that exhibits distinct characteristics on the can result in an unnecessary implantation of a permanent pacemaker and an automatic implantable defibrillator. (6) Diagnostic cardiac catheterizations have been performed on the basis of misdiagnosed artifacts. (6) Electrocardiographic interpreters who have average skills in ECG analysis can readily recognize and differentiate electrocardiographic artifacts. These skills are learned through attendance at organized ECG courses and honed by experience, not by osmosis. Unfortunately, organized courses in ECG interpretation are "history" in nursing and medical school curricula. Summary Skills in differentiating electrocardiographic artifacts are mandatory for healthcare providers who use electrocardiography electrocardiography (ĭlĕk'trōkärdēŏg`rəfē), science of recording and interpreting the electrical activity that precedes and is a measure of the action of heart muscles. in diagnosis and treatment. Artifacts are more common than appreciated. Clues are usually present, but you see only what you look for and recognize only what you know. In the case described here, the stable clinical state during the ECG recording is evidence that the cardiac rate was not that of the artifactual oscillations oscillations See Cortical oscillations. ; namely, 220 beats per minute beats per minute Cardiac pacing The unit of measure for the frequency of heart depolarizations or contractions each minute–or pulse rate . Finally, a diagnosis is not made and management is not determined on the basis of an ECG interpretation, rather the ECG interpretation is one factor in determining the complete diagnosis. ACKNOWLEDGMENTS Supported in part by a grant from the Applebaum Foundation in loving memory of Mr. Joseph Applebaum. Reprint requests: Louis Lemberg, MD, University of Miami This article is about the university in Coral Gables, Florida. For the university in Oxford, Ohio, see Miami University. The University of Miami (also known as Miami of Florida,[2] UM,[3] or just The U Miller School of Medicine, Division of Cardiology (D-39), P.O. Box 0169690, Miami, FL 33101. Kathryn Buchanan Keller, RN, PhD, and Louis Lemberg, MD. From the Florida Atlantic University “FAU” redirects here. For other uses, see FAU (disambiguation). Florida Atlantic University, also referred to as FAU or Florida Atlantic, is a public, coeducational research university with its main campus in Boca Raton, Florida, United States. Christine E. Lynn College of Nursing The Christine E. Lynn College of Nursing is an academic college of Florida Atlantic University located in Boca Raton, Florida, USA. The dean of the college is Dr. Anne Boykin. References External links
KBK Kristiansund Ballklubb (Kristiansund Ball Club; Norway) ), and the Division of Cardiology, Department of Medicine, University of Miami Miller School of Medicine, Miami, Fla (LL). REFERENCES (1.) Chung EK. Complex Arrhythmias: Self Assessment--Artifacts Due to Muscle Tremors Resembling Atrial Flutter or Runaway, Artificial Pacemaker (Case 73). New York, NY: Karger; 1985:149-150. (2.) Blake TM. Introduction to Electrocardiography: Artifacts. 2nd ed. New York, NY: Meredith Corp; 1972:153-158. (3.) Burdick E350 Operating Manual. Milton, Wis: Siemens Burdick, Inc; 1990. (4.) American Association of Critical-Care Nurses Practice Alert. Dysrhythmia dysrhythmia /dys·rhyth·mia/ (dis-rith´me-ah) 1. disturbance of rhythm. 2. an abnormal cardiac rhythm; the term arrhythmia is usually used, even for abnormal but regular rhythms. monitoring. Available at: www.aacn.org. Accessed September 29, 2006. (5.) Drew BJ. Celebrating the 100th birthday of the electrocardiogram: lessons learned from research in cardiac monitoring. Am J Crit Care. 2002:11:378-388. (6.) Knight BP, Pelosi F, Michaud GF, et al. Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia. N Eng1 J Med. 1999;341:1270-1274. (7.) Knight BP, Pelosi F, Michaud GF, et al. Physician interpretation of electrocardiographic artifact that mimics ventricular tachycardia. Am J Med. 2001:110:335-338. (8.) Marquez MF, Colin L, Guevara M, et al. Common electrocardiographic artifacts mimicking arrhythmias in ambulatory monitoring. Am Heart J. 2002:144:187-197. SELECTED REFERENCES Clochesy JM, Cifani L, Howe K. Electrode site preparation techniques: a follow-up study. Heart Lung. 1991;20:27-30. Medina V, Clochesy JM, Ornery or·ner·y adj. or·ner·i·er, or·ner·i·est Mean-spirited, disagreeable, and contrary in disposition; cantankerous. [Alteration of ordinary. A. Comparison of electrode site preparation techniques. Heart Lung. 1989;18:456-460. Schaub FA. Fundamentals of Clinical Electrocardiography. Basel, Switzerland: J. R. Geigy SA; 1966: 17. |
|
||||||||||||||||||

tion n.
Printer friendly
Cite/link
Email
Feedback
Reader Opinion