This year, the Juvenile Diabetes Research Foundation (JDRF) is providing approximately $6 million to fund two studies that will test the viability of both components of a closed-loop system?a glucose sensor and an insulin pump One is the Continuous Glucose Sensor Human Clinical Trial, and the other is the Artificial Pancreas Consortium

This year, the Juvenile Diabetes Research Foundation (JDRF) is providing approximately $6 million to fund two studies that will test the viability of both components of a closed-loop system?a glucose sensor and an insulin pump. One is the Continuous Glucose Sensor Human Clinical Trial, and the other is the Artificial Pancreas Consortium. We spoke to Aaron Kowalski, research director for the JDRF Artificial Pancreas Project, about the two studies and what they hope to achieve.

Explain what a continuous glucose sensor is and why it is such an important innovation.

Continuous glucose sensors are glucose monitors worn on the outside of the body. The sensors have a small-needle access site, which is usually positioned in the abdominal region. This allows the device to continually monitor glucose levels. The data that it collects is displayed on a small device about the size of a pager. A continuous glucose sensor enables a person to see glucose trends?whether glucose is headed up or down?before they go too far in either direction. This lets the person avoid bad lows or excessive highs by having a snack or adjusting insulin levels.

The hypothesis is that continuous sensing is going to help people with diabetes achieve better glucose control than they would using only finger sticks, and several studies have shown promising results. By helping people achieve better glucose control, these devices will help reduce diabetes-related complications in the long term. And they will be an essential part of the closed-loop system, or artificial pancreas.

Who makes continuous glucose devices?

Currently two companies have FDA-approved continuous glucose monitors?DexCom and Medtronic?and a third (Abbott) has a device currently under FDA review. The JDRF does not favor one brand of device over another; the Continuous Glucose Sensor Human Clinical Trial uses all of them.

So how is the Continuous Glucose Sensor Human Clinical Trial set up?

Half of the patients will get their normal standard of care, which is intensive management with finger sticks using glucose monitors. The other half will use continuous sensors. That will go on for six months in a randomized fashion. Then the people who are on finger sticks will switch to the continuous sensors. The people on continuous sensors will stay with them. We call that a limited crossover. It will go on for another six months. We expect to enroll about 500 patients total at sites across the country.

What will you be tracking over that year? Changes in glucose control? Changes in A1Cs?

In the first six months, we will see whether the people using continuous sensing have better glucose control. We?ll be looking at A1Cs, but we?ll also be trying to get a good picture of how the sensor affects the incidence of hypoglycemia and glycemic variability (the swings up and down of blood glucose) and other diabetes outcomes, such as severe lows, days out of work or school due to diabetes, etc. In the second six months, we will see if people can sustain any positive outcomes from using the sensor over the longer period of time.

Is the continuous sensor trial linked to the trial of the artificial pancreas?

Yes. The clinical trials operate separately, but they are linked conceptually. You can?t have a closed-loop system without a reliable continuous glucose monitor. You need a continuous monitor that talks to an insulin pump, and that insulin pump has to be able to take the sensor?s readings, then automatically dispense insulin through the inserted port as the body needs it. Like the pancreas, the closed loop would automatically dispense the right amount of insulin at the right time.

These are exciting times for people with diabetes and for researchers. Diabetes Focus, Second Quarter 2007

Truman Tyler is the professional freelance writer. He''s also the webmaster of About-diabetes.org

Copyright (c) 2008 Free Online Library
This article can be reproduced subject to these terms. Syndicate this article. More free articles for syndication

 Reader Opinion

Title:

Comment:



 

Article Details
Printer friendly Cite/link Email Feedback
Author:Michalle Law
Publication:Food/cooking/nutrition community
Geographic Code:1USA
Date:May 5, 2008
Words:706
Previous Article:Vitamin A - An Insight
Next Article:The Basics of Health and Nutrition



Related Articles
MINIMED MAY GET IMPLANT RIGHTS.
Physiological and behavioral aspects of glycemic control and hypoglycemia in diabetes.
Diabetes Facts
A Short Tutorial About Various Diabetic Supplies
A Brief Overview of Diabetes
My Experiences with Diabetes and the Effects of Cinnamon
Free Diabetes Supplies
No Longer An Adults-Only Disease

Terms of use | Copyright © 2013 Farlex, Inc. | Feedback | For webmasters | Submit articles