Printer Friendly
The Free Library
14,558,467 articles and books
Member login
User name  
Password 
 
Join us Forgot password?

Comparison of techniques to reduce residential lead dust on carpet and upholstery: the New Jersey assessment of cleaning techniques trial.


High-efficiency particulate par·tic·u·late
adj.
Of or occurring in the form of fine particles.

n.
A particulate substance.



particulate

composed of separate particles.
 air (HEPA HEPA  
abbr.
1. high-efficiency particulate air

2. high-efficiency particulate arresting
) filtered vacuum cleaners vacuum cleaner, mechanical device using a draft of air to remove dust, loose dirt, or other particulate matter from dry surfaces. It is especially useful on highly textured surfaces, such as carpets and upholstery, that are difficult to clean by wiping or brushing.  are recommended by the U.S. Department of Homing and Urban Development for cleaning lead-contaminated house dust. We performed a randomized ran·dom·ize  
tr.v. ran·dom·ized, ran·dom·iz·ing, ran·dom·iz·es
To make random in arrangement, especially in order to control the variables in an experiment.
 field study to determine whether a conventional (non-HEPA) vacuum cleaner could achieve cleaning results comparable with those of a HEPA vacuum cleaner. We compared the lead loading reductions of these two vacuum cleaners in a total of 127 New Jersey homes of lead-exposed children. We used wet towelettes and a vacuum sampler sampler, sample piece of needlework or embroidery, of silk, cotton, or worsted, for the preservation of some pattern or as an example of the ability of a child or a beginner. In museums and private collections there are samplers dating from as early as 1643.  to collect lead dust from carpets and upholstery upholstery, general term for household fittings, hangings, curtains, cushions, and covers. It refers to stuffed, padded, and spring-cushioned furniture, such as chairs and sofas, or to the usually decorative materials and fabrics that cover them.  before and after vacuum cleaning. The vacuum sampling data showed that the HEPA and non-HEPA vacuum cleaners resulted in 54.7% (p = 0.006) and 36.4% (p = 0.020) reductions in lead loading, respectively, when used on soiled carpets, although the overall difference in lead loading reduction between the two vacuum cleaners was not statistically significant (p = 0.293). The wipe sampling data did not show any significant lead loading reduction for either of the vacuum cleaners, suggesting that both vacuum cleaners fail to clean the surfaces of carpet effectively, considering that wipe sampling media simulate surface contact. On upholstery, the wipe sampling data showed a significant reduction in lead loading for the non-HEPA vacuum cleaner (22.2%, p = 0.047). Even with the significant reduction, the postcleaning lead loadings on upholstery were similar to those,on carpets. The similar lead loading results for carpets and upholstery indicate that soiled upholstery may be as important a source of childhood lead exposure as carpets. Key words: carpet, cleaning, HEPA, HUD Hud (hd), a pre-Qur'anic prophet of Islam. Hud unsuccessfully exhorted his South Arabian people, the Ad, to worship the One God. , lead, upholstery, U.S. Department of Housing and Urban Development, vacuum. Environ Health Perspect 110:1233-1237 (2002). [Online 17 October 2002]

hwp://ehpnet1.niehs.nih.gov/docs/2002/110p1233-1237yiin/abstract.html

**********

Household dust contaminated contaminated,
v 1. made radioactive by the addition of small quantities of radioactive material.
2. made contaminated by adding infective or radiographic materials.
3. an infective surface or object.
 with lead is a major source of childhood lead exposure (Bornschein et al. 1986; Cambra and Alonso 1995; Charney et al. 1983; Clark et al. 1991; Davies et al. 1991; Lanphear et al. 1996; Rhoads et al. 1999; Thornton et al. 1990), with the hand-to-mouth pathway generally accepted as the most important exposure pattern for young children [U.S. Department of Housing and Urban Development (HUD) 1995]. Carpets, unlike bare floors or other smooth surfaces, serve as a reservoir of dust in home environments. A number of studies have shown that surface lead loading assessed by vacuuming carpets is far greater than that derived from vacuuming bare floors (Adgate et al. 1995; Lanphear et al. 1995; Sterling et al. 1999). Although little is known about how much lead dust is embedded Inserted into. See embedded system.  in upholstered furniture, presumably pre·sum·a·ble  
adj.
That can be presumed or taken for granted; reasonable as a supposition: presumable causes of the disaster.
 old or dirty furniture can also contain substantial amounts of lead-contaminated dust.

Dust control can be effective in reducing children's exposure to lead [Centers for Disease Control (CDC See Control Data, century date change and Back Orifice.

CDC - Control Data Corporation
) 1991; Charney et al. 1983; Hilts et al. 1995, 1998; Lioy et al. 1998; Rhoads et al. 1999; Roberts et al. 1999]. An effective dust control, however, needs more effort in cleaning carpets or rugs than in cleaning hard floor surfaces because carpets can store and trap amounts of dust. High-efficiency particulate air (HEPA) filtered vacuum cleaners are recommended by the HUD to clean lead-contaminated dwellings, both as an interim control measure and after lead abatement A reduction, a decrease, or a diminution. The suspension or cessation, in whole or in part, of a continuing charge, such as rent.

With respect to estates, an abatement is a proportional diminution or reduction of the monetary legacies, a disposition of property by will, when
 activities (HUD 1995). HEPA vacuum cleaners may be more effective in cleaning carpets than are regular household vacuum cleaners because the filter can prevent small particles from re-entrainment. Nevertheless, HEPA vacuum cleaners are expensive, and until recently, they were not widely available. Because dust lead levels in most households are generally not as high as dust lead levels after lead abatement work, use of a HEPA vacuum cleaner for home cleaning as an interim control measure might not be necessary Little is known regarding the effectiveness of using a common type of household vacuum cleaner to clean lead dust in homes of children who have moderately elevated blood lead levels.

The New Jersey Assessment of Cleaning Techniques (NJACT) Trial compared the effectiveness of using a non-HEPA vacuum with using a HEPA vacuum cleaner, and the effectiveness of using a low-phosphate detergent detergent (dētûr`jənt, dĭ–), substance that aids in the removal of dirt. Detergents act mainly on the oily films that trap dirt particles.  with a high-phosphate detergent (or equivalently performing detergent) in reducing dust lead levels in homes of lead-exposed children. In this article we compare the efficacy of a HEPA and a non-HEPA vacuum cleaner in removing lead dust from carpets/rugs and upholstered furniture and also assess residential accumulation of lead dust in carpets and on upholstery after a 6-month period in selected NJACT trial participating homes.

Methods

Cleaning and sampling methods. The methods for NJACT trial have been described previously (Rich et al. 2002). There were 127 New Jersey homes recruited with a child's blood lead level above 20 [micro]g/dL at each home. These homes were referred to us either by the state health department or by local health departments in northern New Jersey. Upon recruitment, we scheduled a 1-day cleaning appointment with the study participant and then cleaned the house using a randomly selected cleaning protocol. We used a Nilfisk GS80 HEPA vacuum cleaner (Nilfisk of America, Inc., Malvern, PA) and a Eureka World canister vacuum cleaner (model 6865; Eureka Co., Bloomington, IL) to clean carpets and upholstery in homes assigned to the HEPA and non-HEPA cleaning, respectively. Because the study was also designed to test cleaning methods that were applied to hard surface cleaning, three cleaning combinations of the two vacuum cleaners and two types of detergents, trisodium tri·so·di·um  
adj.
Containing three sodium atoms.
 phosphate (TSP TSP - travelling salesman problem ) and household (Spic n' Span; Procter & Gamble, Cincinnati, OH) detergents, were used: a) TSP and HEPA, b) TSP and non-HEPA, and c) household detergent and non-HEPA. This randomized assignment to the three combinations of cleaning methods resulted in homes being assigned to the non-HEPA vacuum cleaner and the HEPA vacuum cleaner in an approximate 2:1 ratio. Because not all recruited homes had carpets or upholstered furniture, the total numbers of carpet and upholstery cleaning were less than the total homes that we recruited.

Vacuum cleaning followed the HUD guidelines (HUD 1995) which recommend that a beater beat·er  
n.
1. One that beats, especially a device for beating: a carpet beater.

2. A person who drives wild game from under cover for a hunter.
 bar or agitator ag·i·ta·tor  
n.
1. One who agitates, especially one who engages in political agitation.

2. An apparatus that shakes or stirs, as in a washing machine.

Noun 1.
 attachment be equipped on the vacuum head while vacuuming carpets. Each carpet was vacuumed twice in perpendicular directions, and each pass was performed at a deliberate speed in order to maximize dust collection from the carpet. Upholstery vacuuming was performed with three to five passes over each surface with a smooth-edged nozzle An orifice in an inkjet print head through which ink is sprayed onto the paper. Print heads with six thousand or more nozzles are common in today's printers.
Nozzle 
. A new vacuum bag for the HEPA or non-HEPA vacuum was installed before vacuuming in each participating home.

Two dust-sampling methods were used side by side to collect lead dust on carpet and upholstery before and after cleaning in each household to evaluate cleaning effectiveness: a wet-towelette wipe method, as recommended by HUD (1995), and a vacuum method previously developed by the Environmental and Occupational Health Sciences Institute (EOHSI EOHSI Environmental and Occupational Health Sciences Institute ) (Wang et al. 1995). Before cleaning, study staff collected a wipe sample and an EOHSI vacuum sample from a selected carpet, and another pair of wipe and vacuum samples from upholstery in each household. Postcleaning samples were collected at least 1 hr after cleaning to allow any airborne dust that was generated by vacuuming to settle. Sampling sites adjacent to the respective precleaning sites were used. Wipe sampling was conducted within a 1-[ft.sup.2] template on the surfaces of carpet or upholstered furniture. The EOHSI vacuum sample method was performed using a canister vacuum to collect dust samples from carpets within a 2.78-[ft.sup.2] template and from upholstery within a 1-[ft.sup.2] template. We used a nozzle head with zigzag teeth when sampling carpets, and a smooth-edged nozzle head to avoid damaging fibers of the fabric when sampling upholstery. A cone-shaped sample bag made of polyethylene and polypropylene polypropylene (pŏl'ēprō`pəlēn), plastic noted for its light weight, being less dense than water; it is a polymer of propylene. It resists moisture, oils, and solvents.  (5.2 oz. SMS (1) (Storage Management System) Software used to routinely back up and archive files. See HSM.

(2) (Systems Management Server) Systems management software from Microsoft that runs on Windows NT Server.
; Home Care Industries, Inc., Clifton, NJ) was installed between the nozzle head and the vacuum hose to trap the collected dust.

In seven households after cleaning and dust sampling, we installed a new area rug area rug
n.
A rug that covers a limited area of floor space in a room.
 to determine the extent to which lead contamination would recur within 6 months. We believe the rugs are lead-free became we did not find detectable lead levels using the EOHSI vacuum sampling. The new 6 x 9 ft area rug was laid on. top of the old wall-to-wall carpet. Similarly, in selected houses we covered one piece of upholstered furniture with a rubber-backed couch cover, held in place with safety pins. After 6 months, study staff returned to the households and collected follow-up dust samples from the installed area rugs and/or couch covers. We compared the follow-up samples and precleaning baseline samples to evaluate dust buildup build·up also build-up  
n.
1. The act or process of amassing or increasing: a military buildup; a buildup of tension during the strike.

2.
 in the new carpet and on the upholstery cover over a 6-month period.

Laboratory analysis. Wipe samples were soaked and then digested in a laboratory microwave (MDS-2000; CEM CEM

contagious equine metritis.


CEM selective medium
chocolate agar made with Eugon agar and 5% horse blood; used to cultivate Taylorella equigenitalis.
 Corporation, Matthews, NC). Lead concentrations (micrograms per gram) of wipe samples were determined by using a flame atomic absorption spectrometer spectrometer

Device for detecting and analyzing wavelengths of electromagnetic radiation, commonly used for molecular spectroscopy; more broadly, any of various instruments in which an emission (as of electromagnetic radiation or particles) is spread out according to some
 (FAA; 3100; Perkin-Elmer, Norwalk, CT). For those samples with concentrations under the FAA detection limit (0.5 [micro]g/mL in solution), a graphite furnace atomic absorption Graphite furnace atomic absorption spectrometry (GFAAS) (also known as Electrothermal Atomic Absorption Spectrometry (ETAAS)) is a type of spectrometry that uses a graphite-coated furnace to vaporize the sample.  spectrophotometer spectrophotometer, instrument for measuring and comparing the intensities of common spectral lines in the spectra of two different sources of light. See photometry; spectroscope; spectrum.  (GFAA GFAA Graphite Furnace Atomic Absorption
GFAA Game Fishing Association of Australia
GFAA Gainesville Fine Art Association (Florida) 
; Perkin-Elmer Zeeman 5100; Perkin-Elmer) with a detection limit of 2.5 [micro]g/L (in solution) was used. Details of wipe sample analysis have been described previously (Rich et al. 2002).

Vacuum sample bags were weighed in a temperature- and humidity-controlled room using a microbalance mi·cro·bal·ance  
n.
A balance designed to weigh very small loads, up to 0.1 gram.

Noun 1. microbalance - balance for weighing very small objects
balance - a scale for weighing; depends on pull of gravity
 (Sartorius A120S; Sartorius Corporation, Edgewood, NY). After postsampling weighing, if available, approximately 0.2 g of dust was measured and placed into a test tube (30-mL Oak Ridge Oak Ridge, city (1990 pop. 27,310), Anderson and Roane counties, E Tenn., on Black Oak Ridge and the Clinch River; founded by the U.S. government 1942, inc. as an independent city 1959.  Centrifuge centrifuge (sĕn`trəfyj), device using centrifugal force to separate two or more substances of different density, e.g., two liquids or a liquid and a solid.  Tube; Nalgene, Rochester, NY). Nitric acid nitric acid, chemical compound, HNO3, colorless, highly corrosive, poisonous liquid that gives off choking red or yellow fumes in moist air. It is miscible with water in all proportions.  [10 mL of 19% (vol/vol)] was added to the samples, and then the samples were microwave digested for 23 min at 81% power using the U.S. Environmental Protection Agency Environmental Protection Agency (EPA), independent agency of the U.S. government, with headquarters in Washington, D.C. It was established in 1970 to reduce and control air and water pollution, noise pollution, and radiation and to ensure the safe handling and  (EPA EPA eicosapentaenoic acid.

EPA
abbr.
eicosapentaenoic acid


EPA,
n.pr See acid, eicosapentaenoic.

EPA,
n.
) soil sample protocol (U.S. EPA 1991). After cooling, deionized water Deionized water (DI water or de-ionized water; also spelled deionised water, see spelling differences) is water that lacks ions, such as cations from sodium, calcium, iron, copper and anions such as chloride and bromide.  was added to dilute each sample to 20 mL for FAA analysis. Samples that were below the detection limit were analyzed on GFAA.

Statistical analysis. All dust wipe data were adjusted using a linear regression Linear regression

A statistical technique for fitting a straight line to a set of data points.
 equation to correct for laboratory difference (Rich et al. 2002). All data derived from the wipe and vacuum samples were log-transformed (base 10) before statistical analysis because they appeared log-normally distributed. We used one-half of the GFAA detection limit for wipe or vacuum data under the detection limit. Paired-sample t-tests were performed separately for the wipe and vacuum data to compare pre- and postcleaning lead loadings and to compare precleaning lead loadings of carpets and upholstery in the same houses. Pearson correlation coefficients Correlation Coefficient

A measure that determines the degree to which two variable's movements are associated.

The correlation coefficient is calculated as:
 were calculated to examine relationships between the two sampling methods and between precleaning lead loadings and lead loading reductions. A nested-factorial design analysis of variance (ANOVA anova

see analysis of variance.

ANOVA Analysis of variance, see there
) using the generalized linear model Not to be confused with general linear model.
In statistics, the generalized linear model (GLM) is a useful generalization of ordinary least squares regression. It relates the random distribution of the measured variable of the experiment (the
 was conducted to compare the two cleaning methods using HEPA and non-HEPA vacuum cleaners in lead loading reduction. We used SPSS A statistical package from SPSS, Inc., Chicago (www.spss.com) that runs on PCs, most mainframes and minis and is used extensively in marketing research. It provides over 50 statistical processes, including regression analysis, correlation and analysis of variance.  for Windows 9.0 (SPSS, Chicago, IL) to run all statistical analyses.

Results

Carpet cleaning. We collected 89 and 90 pairs of pre- and postcleaning carpet samples using the wipe and EOHSI vacuum sampling methods, respectively. There was one EOHSI vacuum sample missing in a pre- and postcleaning pair that was collected in a non-HEPA home. More than 96% of the carpet samples from either the wipe or EOHSI vacuum sampling method had lead levels greater than the detection limit, and most of the samples with values below the detection limit were the postcleaning samples. Data from the EOHSI vacuum sampling method showed a significant reduction (50.6%, p = 0.014) in mean lead loading for cleaning using the HEPA vacuum cleaner but did not result in a significant difference (14.0% reduction) for cleaning using the non-HEPA vacuum cleaner (Table 1). The wipe sampling results indicated that neither of the cleaning methods yielded a significant reduction in lead loading. To examine whether cleaning performance was affected by precleaning dust lead levels, we conducted correlation analyses between precleaning lead loadings and lead loading reductions with the wipe data and the EOHSI vacuum data. Both the databases indicated that lead loading reductions were moderately associated with the precleaning levels (r = 0.41 for wipe and 0.32 for vacuum). Because dust lead reductions were affected by precleaning levels and dust lead levels in the participants' homes varied substantially [EOHSI vacuum geometric standard deviation In probability theory and statistics, the geometric standard deviation describes how spread out are a set of numbers whose preferred average is the geometric mean. If the geometric mean of a set of numbers is denoted as μg  (GSD GSD German Shepherd Dog
GSD Graduate School of Design
GSD Glycogen Storage Disease
GSD General Services Division
GSD Gundam Seed Destiny (anime)
GSD Ground Sample Distance
GSD Geometric Standard Deviation
) = 8.7 and 9.5 for precleaning levels of the HEPA and non-HEPA groups, respectively], we stratified stratified /strat·i·fied/ (strat´i-fid) formed or arranged in layers.

strat·i·fied
adj.
Arranged in the form of layers or strata.
 our analyses by examining results from carpets with high lead loading to evaluate performance of the HEPA and non-HEPA vacuum cleaners.

We used 10 [micro]g/[ft.sup.2] (antilog an·ti·log  
n.
An antilogarithm.

Noun 1. antilog - the number of which a given number is the logarithm
antilogarithm
 of 1) as the cutoff point Cutoff point

The lowest rate of return acceptable on investments.
 for precleaning data derived from the EOHSI vacuum method because there is no vacuum-dust lead clearance standard established for carpets and we wanted to retain the bulk of the data. Approximately 80% of the baseline data were above this cutoff for both vacuum cleaners. The new database, termed "soiled," increased the percentage of lead loading reduction for the HEPA data by 4.1% (from 50.6% to 54.7%) and especially for the non-HEPA data by 22.4% (from 14.0% to 36.4%) as measured by the EOHSI vacuum samples but did not significantly change the results observed based on the wipe data (Table 2). The smaller vacuum lead loading reduction for the non-HEPA data than for the HEPA data suggests a better cleaning performance by the HEPA vacuum cleaner on carpets. To confirm this, we performed a nested-factorial design ANOVA for the soiled data. The results indicate that both vacuum cleaners reduced dust lead levels in soiled carpets effectively (p < 0.001) and that the difference between the lead loading reductions resulting from the two vacuum cleaners was not statistically significant (p = 0.293). Thus, on soiled carpets, both HEPA and non-HEPA vacuum cleaners were effective in reducing dust lead loading, as determined by vacuum sampling, but were not demonstrably de·mon·stra·ble  
adj.
1. Capable of being demonstrated or proved: demonstrable truths.

2. Obvious or apparent: demonstrable lies.
 different in cleaning performance.

Upholstery cleaning. There were 80 and 77 pairs of pre-and postcleaning upholstery samples collected by the EOHSI vacuum method and the wipe method, respectively. Three wipe sample pairs were incomplete because of missing samples. Unlike the carpet data, a large portion of the EOHSI vacuum samples (37.5%) failed to yield detectable levels of lead. This was mostly related to inadequate dust recovery. In contrast, 98% of the wipe samples yielded measurable levels, indicating that the wipe method is more appropriate than vacuum sampling for use in assessing the effectiveness of upholstery cleaning.

The upholstery data showed a significant lead loading reduction for the non-HEPA vacuum cleaner by both the EOHSI vacuum and wipe sampling techniques, whereas no significant reduction was found for the HEPA vacuum group (Table 1). The cleaning performance by the HEPA vacuum cleaner, however, may have been affected by the low precleaning dust lead levels, as shown by both the EOHSI vacuum method and the wipe sampling method. Lead loading reductions were associated with precleaning lead loadings for upholstery as indicated by the wipe method (r = 0.30) and especially the EOHSI vacuum method (r = 0.65). We removed a small portion of low-end upholstery data using 3.15 [micro]g/[ft.sup.2] (antilog of 0.5, half of cutoff point for carpet data) for the precleaning wipe data as a cutoff point. The "soiled" upholstery database showed significant differences for the non-HEPA vacuum method but still no significant difference for the HEPA vacuum method (Table 2).

Dust lead levels in carpets and upholstery. We combined precleaning data of the HEPA and non-HEPA homes where there were carpets and upholstery to compare the baseline dust lead levels (Table 3). Lead loading on upholstery was lower than on carpets, as shown by both the EOHSI vacuum and wipe sampling methods. The mean dust lead loading was 9.4 times higher in carpets than on upholstery by the EOHSI vacuum method, but it was only 1.5 times higher by the wipe method. This result indicates that upholstered furniture is not as significant a reservoir for lead dust as are carpets; however, it may be similar to carpets in importance as a source of childhood lead exposure via surface contact, as indicated by the similar mean lead loadings derived from the wipe method.

Correlation of sampling methods. We conducted correlation analyses between the EOHSI vacuum and wipe sampling methods applied on carpets before and after cleaning. Data below the level of detection were not included. Both pre- and postcleaning data showed that the vacuum and HUD wipe methods were moderately correlated (r [approximately equal to] 0.70, p < 0.001). This correlation result is quite substantial considering the difference between the two methods. We did not conduct a correlation analysis for the upholstery data because of a relatively large portion of nondetects of EOHSI vacuum samples on upholstery. Details of the comparison of the two sampling methods have been described previously (Bai et al. in press).

Six-month follow-ups. Six-month follow-up sampling was completed for seven carpet and five upholstery sample sets. The follow-up lead loadings, by either the wipe or the EOHSI vacuum method, showed various trends from the precleaning lead loadings (Table 4). This result indicates that dust lead accumulation on carpets is likely to be sufficient to return dust lead to the precleaning (baseline) levels during a period of 6 months. The follow-up lead loadings on upholstery, shown as the wipe data, were all less than the baseline levels after 6 months. Nevertheless, there were two lead loading increases, shown by the EOHSI vacuum samples. The wipe and vacuum data on upholstery suggest that there are certain levels of dust lead accumulation on upholstery that may not be as high as the baseline levels.

Discussion

Both the HEPA and non-HEPA vacuum cleaners significantly reduced carpet lead loadings measured by the EOHSI vacuum sampling technique, when the carpets showed relatively high dust-lead loadings (Table 2). The HEPA vacuum cleaner used in this study appeared to be better than the non-HEPA vacuum cleaner in removing lead dust from the carpets, as indicated by the relatively large reductions in lead loading for the HEPA group (Tables 1 and 2), although the difference in dust lead reductions between the two vacuum cleaners was not statistically significant. The difference between lead loading reductions resulting from the HEPA and non-HEPA vacuum cleaners may be due to their different characteristics: the HEPA vacuum cleaner was equipped with a HEPA filter bag and performed with a strong suction suction /suc·tion/ (suk´shun) aspiration of gas or fluid by mechanical means.

post-tussive suction  a sucking sound heard over a lung cavity just after a cough.
 flow rate (87 [ft.sup.3]/min, reported by the manufacturer, Nilfisk of America), whereas the non-HEPA vacuum cleaner used a regular household vacuum bag and operated with a flow rate of 66.3 [ft.sup.3]/min (tested by Inter Basic Resources, Inc. Grass Lake, MI). The HEPA vacuum filtration is believed to prevent dust re-entrainment, which may recontaminate carpet surfaces after using a non-HEPA vacuum cleaner. This study did not measure differences of the emission of lead particulates from the two vacuum cleaners' exhaust stream; however, after a postcleaning settling period of at least 1 hr, dust lead loadings on floors were not found significantly elevated in houses that had been cleaned with the non-HEPA vacuum cleaner compared with the HEPA vacuum cleaner (Rich et al. 2002). This finding suggests that re-entrainment should not be a major source of postcleaning contamination.

In recent research conducted by the California Department of Health Services Department of Health Services may refer to:
  • Los Angeles County Department of Health Services
  • California Department of Health Services a California state agency
 (CDHS CDHS California Department of Health Services
CDHS Colorado Department of Human Services
CDHS Center for Development of Human Services
CDHS Central Dauphin High School (Harrisburg, PA, USA)
CDHS Comprehensive Data Handling System
) using several types of non-HEPA household vacuum cleaners (canisters, shop, and uprights), no detectable airborne lead levels (< 0.5 [micro]g/[m.sup.3]) were observed after vacuuming vinyl floors in housing units with lead loadings up to 800 [micro]g/[ft.sup.2] (Wall S. Personal communication). Also, CDHS laboratory particle counts conducted before, during, and after non-HEPA vacuuming of real-world lead test dust from vinyl floors in a HEPA-filtered environmental clean room were consistent with submicrometer aerosol aerosol (âr`əsōl,–sŏl): see colloid.
aerosol

System of tiny liquid or solid particles evenly distributed in a finely divided state through a gas, usually air.
 generation by the non-HEPA motor, rather than re-entrainment of vacuumed lead dust. (Wall S. Personal communication). Thus, the differences in carpet cleaning efficacy between vacuum cleaners tested in this study may have been due to factors other than the presence or absence of HEPA filtration capacity (e.g., suction power). Despite the lesser cleaning efficacy, the non-HEPA vacuum cleaner did achieve a moderate reduction in carpet lead loading in the most soiled carpets, and other non-HEPA household vacuum cleaners would be expected to perform similarly to the model tested in the study. This is important because lower priced vacuum cleaners, many of which do not have HEPA filters, are more affordable to low-income families who experience the most severe lead hazards. Although some HEPA filters are now available for less expensive vacuum cleaners, the cost of their replacement can be substantial.

Although data from the EOHSI vacuum method showed significant lead loading reductions for carpets, the wipe data did not show any significant lead loading reduction for either the HEPA or non-HEPA vacuum cleaner (Tables 1 and 2). The EOHSI vacuum sampler can collect dust embedded in carpets (Wang et al. 1995), whereas the wet towelette tow·el·ette  
n.
A small, usually moistened piece of paper or cloth used for cleansing.
 wipes are considered a surface sampling method. Apparently, the two vacuum cleaners reduced dust lead levels within the carpet pile significantly, but failed to show the same cleaning efficacy on carpet surfaces after just one vacuuming. The vacuuming augmented with a beater bar was probably more effective in removing larger dust particles from carpets versus fine particulates, which have been considered to adhere closely to carpet fibers, probably because of the charge generated by contact (e.g., vacuuming) (Rodes et al. 2001). The wipe media might then have collected a fraction of strongly adherent adherent /ad·her·ent/ (-ent) sticking or holding fast, or having such qualities.  dust from fibers at the carpet surfaces because the wet towelettes could loosen and remove these particles. A vacuum cleaner with a dirt detector was reported helpful in removing nearly all dust from carpets (Roberts et al. 1999). With the help of the dirt detector, this vacuum cleaner may be able to remove more dust from carpets than other vacuum cleaners, resulting in a significant surface lead reduction. In addition, frequent vacuuming for longer time periods with occasional steam cleaning may be more effective in removing dust from carpets. Alternatively, removal of old carpets and area rugs may ultimately be a more cost-effective option (Ewers et al. 1994).

Upholstery, unlike deep pile carpets, did not store a significant amount of lead dust, as indicated by the EOHSI vacuum sampling method that collected only approximately one-seventh of the lead dust sampled from upholstery compared with carpets (Table 3) and failed to collect any lead-bearing dust from a significant fraction (~35%) of sampled furniture (large GSDs in Tables 1 and 2). However, the wipe data showed that the mean upholstery lead loading was not significantly different from the mean carpet lead loading (Table 3), indicating that upholstered furniture, before any cleaning, can be just as important a source of lead exposure via surface contact, even though the total lead stores are far less. The cleaning trial on upholstery showed a significant reduction in lead loading for the non-HEPA vacuum cleaner but not for the HEPA vacuum cleaner (Tables 1 and 2). This result in favor of the non-HEPA vacuum method is in contrast to the result suggesting the HEPA vacuum cleaner to be more effective in cleaning carpets. The reduced efficiency of the HEPA vacuum cleaner in cleaning upholstery may be, at least partially, due to the lower precleaning dust lead level and the smaller sample data set for the HEPA vacuum cleaner than for the non-HEPA vacuum cleaner. Even with a significant reduction in lead loading, the non-HEPA vacuum's cleaning ability remained limited on highly soiled upholstery because the mean postcleaning dust lead level, measured by the wipe media, was similar to that derived from carpets (Table 2). As suggested for carpets, more frequent and longer vacuuming with periodic steam cleaning may be more effective in reducing lead dust accumulation on upholstery.

The lead loadings measured by the wipe method on upholstery and carpets were considerably lower than those on bare floors, windowsills, and window troughs (Rich et al. 2002), which was also the case in a field study of various dust lead sampling methods (Lanphear et al. 1995). The nonsmooth surfaces of upholstery and carpets, which have textured fiber surfaces, can physically decrease the collection efficiency of wipes. This is consistent with the work of Reynolds et al. (1997), which demonstrated a low recovery rate (~26%) for sampling on carpets using the wet towelette wipe method in a laboratory chamber. Because the wipe method somewhat simulates hand contact, it may indicate that a child's hands are likely to pick up less lead per contact from a carpet than from a bare floor. Despite relatively low lead loading on the surface, carpets remain a major source of exposure when they are heavily loaded with lead dust. This is especially important considering the difficulty in effectively cleaning lead contaminated carpets. Upholstery, with the equivalent lead loading on the surface but a relatively low capacity for storing dust, may still be a significant source of childhood lead exposure, especially when heavily soiled.

The follow-up trial of area rugs and furniture covers indicates that, in the absence of effective lead source control, it takes 6 months or less for the dust lead levels in carpets and on upholstery to increase to the levels observed in this study before cleaning. This result suggests that replacing carpets and coveting upholstery are of limited efficacy in reducing lead exposure in the absence of frequent cleaning or source control. Our previous work has shown that frequent cleaning can help avoid lead dust accumulation (Lioy et al. 1998; Rhoads et al, 1999); the present study shows that the household vacuum cleaner that was tested was similar in effectiveness to the tested HEPA vacuum cleaner in reducing lead dust in the homes of children with elevated blood lead levels. Thus, frequent cleaning for longer periods may be more important than using a specific vacuum cleaner to reduce dust lead levels in carpets and on upholstery.

Conclusions

In this study, a household vacuum cleaner without HEPA filtration performed nearly as well as a HEPA vacuum cleaner in cleaning soiled carpets. It can be used as a replacement cleaner for cleaning lead dust in carpets if a HEPA vacuum cleaner is not available. Frequent carpet and upholstery cleaning is encouraged because it appears that the effectiveness of one-time vacuuming is limited. Upholstered furniture may be as important a source of lead dust as carpets for surface contact, although it does not store as much dust as carpets.
Table 1. Pre- and postcleaning lead loadings ([micro]g/[ft.sup.2])
of carpets and upholstery by vacuum cleaner type.

                                    HEPA

                             Pre          Post
                     n     GM (GSD)     GM (GSD)    p-Value

Carpets
  EOHSI vacuum       31   52.4 (8.7)   25.9 (11)     0.014
  Wipe               31   7.02 (3.9)   5.44 (5.3)    0.154
Upholstery
  EOHSI vacuum (b)   25   3.55 (31)    2.24 (38)     0.547
  Wipe               25   3.87 (3.5)   3.25 (4.6)    0.349

                                      Non-HEPA

                                 Pre          Post
                       n       GM (GSD)     GM (GSD)    p-Value
Carpets
  EOHSI vacuum       58 (a)   54.4 (9.5)   46.8 (8.6)    0.431
  Wipe               59       8.76 (4.9)   8.70 (4.1)    0.971
Upholstery
  EOHSI vacuum (b)   55       11.2 (26)    1.41 (36)     0.001
  Wipe               52 (a)   7.26 (4.4)   5.65 (3.8)    0.047

GM, geometric mean.

(a) Missing samples in pre- and postcleaning pairs. (b) More than
35% of overall pre- and postcleaning data for upholstery replaced
with one-half the detection limit.

Table 2. Pre- and postcleaning lead loadings ([micro]g/[ft.sup.2]) of
carpets and upholstery (soiled).

                                HEPA

                         Pre          Post
                 n     GM (GSD)     GM (GSD)    p-Value

Carpets (a)
  EOHSI vacuum   25    118 (3.8)   53.3 (7.7)    0.006
  Wipe           25   11.4 (2.8)   8.97 (3.9)    0.254
Upholstery (b)
  EOHSI vacuum   13   6.41 (21)    3.43 (25)     0.483
  Wipe           13   11.0 (1.7)   9.42 (2.9)    0.528

                               Non-HEPA

                         Pre          Post
                 n     GM (GSD)     GM (GSD)    p-Value

Carpets (a)
  EOHSI vacuum   47    113 (5.3)   71.6 (6.3)    0.020
  Wipe           47   11.5 (4.8)   10.3 (3.8)    0.615
Upholstery (b)
  EOHSI vacuum   37   8.46 (30)    1.02 (33)     0.007
  Wipe           37   14.4 (3.0)   9.34 (3.4)    0.005

GM, geometric mean.

(a) Carpet selection: precleaning levels of EOHSI vacuum data
[greater than or equal to] 10 [micro]g/[ft.sup.2] (antilog of 1.0).
(b) Upholstery selection: precleaning levels of wipe data [greater
than or equal to] 3.15 [micro]g/[ft.sup.2] (antilog of 0.5).

Table 3. Mean precleaning lead loadings on carpets
and upholstery in the same houses.

                                     n     GM    GSD     95% CI

EOHSI vacuum ([micro]g/[ft.sup.2])
  Carpet                             58   47.9    12   (25.0-91.7)
  Upholstery                         58   5.11    29   (2.12-12.3)
Wipe ([micro]g/[ft.sup.2])
  Carpet                             57   6.53   4.1   (4.48-9.51)
  Upholstery                         57   4.37   3.9   (3.04-6.30)

Abbreviations: CI, confidence interval; GM, geometric mean.

Table 4. Lead loading comparisons between samples
from precleaning carpet and upholstery and
follow-up samples from new area rugs and upholstery
covers installed and left in place for 6 months.

                      Wipe                  EOHSI vacuum
              ([micro]g/[ft.sup.2])     ([micro]g/[ft.sup.2])

Home         Pre (a)   Follow-up (b)   Pre (a)   Follow-up (b)

Carpets
  1           3.80         6.51         29.5      120
  2           0.66         0.55          1.48       2.04
  3          21.9          4.61         39.8      129
  4          13.2         83.7         302        831
  5           6.87         8.01        426         38.0
  6          17.2         30.6         257        302
  7          41.5         20.4         104        165
  GM          8.63         9.49         66.9       90.6
  GSD         4.0          5.0           7.1        6.8
Upholstery
  1            NA           NA          14.8       45.7
  2           0.74         0.59         25.7        3.89
  3           3.80         3.39        147         69.2
  4           7.05         5.57         22.4       50.1
  5           4.61         2.63        123          0.05 (c)
  GM          3.09         2.33         43.5        7.90
  GSD         2.7          2.6           2.9       21.2

Abbreviations: GM, geometric mean; NA, sample unavailable.

(a) Precleaning values on original carpets or upholstery.
(b) Follow-up values from new area rugs or upholstery covers
that had been in place for 6 months. (c) Use of one-half
detection limit in place of nondetected datum.


REFERENCES

Adgate JL, Weisel C, Wang Y, Rhoads GG, Lioy PJ. 1995. Lead in house dust: relationships between exposure metrics metrics Managed care A popular term for standards by which the quality of a product, service, or outcome of a particular form of Pt management is evaluated. See TQM. . Environ Res 70:134-147.

Bai Z, Yiin LM, Rich DQ, Adgate J, Ashley PJ, Lioy PJ, Rhoads GG, Zhang J. In press. Field evaluation and comparison of five methods of sampling lead dust on carpets. Am Ind Hyg Assoc J.

Bornschein RL, Succop PA, Krafft KM, Clark CS, Peace B, Hammond PB. 1986. Exterior surface dust lead, interior house dust lead, end childhood lead exposure in an urban environment. In: Trace Substances in Environmental Health XX, a Symposium (Hemphill DD, ed). Columbia, MO:University of Missouri, 322-332.

Cambra K, Alonso E. 1995. Blood lead levels in 2- to 3-year-old children in the Greater Bilbao Greater Bilbao (Basque: Bilbo Handia, Spanish: Gran Bilbao) is a metropolitan area of Biscay, Spain.  Area (Basque Country Basque Country (băsk, bäsk), Basque Euzkadi, Span. País Vasco, comprising the provinces of Álava, Guipúzcoa, and Vizcaya (1990 pop. , Spain): relation to dust and water lead levels. Arch Environ Health 50(5):362-366.

CDC. 1991. Preventing Lead Poisoning lead poisoning or plumbism (plŭm`bĭz'əm), intoxication of the system by organic compounds containing lead.  in Young Children: A Statement by the Centers for Disease Control. Atlanta, DA:Centers for Disease Control.

Charney E, Kessler B, Farfel far·fel or far·fal  
n.
Noodles shaped like small grains or pellets.



[Yiddish farfl, from Middle High German varveln.]
 M, Jackson D. 1983. A controlled trial controlled trial Clinical research A clinical study in which one group of participants receives an experimental drug while the other receives either a placebo or an approved–'gold standard' therapy. See Blinding, Double-blinded.  of the effect of dust-control measures on blood lead levels. N Engl J Med 309:1089-1093.

Clark S, Bornschein R, Succop P, Roda S, Peace B. 1991. Urban lead exposures of children in Cincinnati, Ohio “Cincinnati” redirects here. For other uses, see Cincinnati (disambiguation).
Cincinnati is a city in the U.S. state of Ohio and the county seat of Hamilton County.
. Chem Speciation speciation

Formation of new and distinct species, whereby a single evolutionary line splits into two or more genetically independent ones. One of the fundamental processes of evolution, speciation may occur in many ways.
 Bioavail 3(3/4):163-171.

Davies DJA DJA

See Dow Jones Averagesr (DJA).
, Thornton I, Watt JM, Culbard EB, Harvey PG, Delves Delves is a village in County Durham, in England. It is situated a short distance to the south of Consett.  HT, et al. 1991. Lead intake and blood lead in two-year-old U.K. urban children. Sci Total Environ 90:13-29.

Ewers L, Clark S, Menrath W, Succop P, Bornschein R. 1994. Clean-up of lead in household carpet and floor dust. Am Ind Hyg Assoc J 55:50-657.

Hilts SR, Bock Noun 1. bock - a very strong lager traditionally brewed in the fall and aged through the winter for consumption in the spring
bock beer

lager beer, lager - a general term for beer made with bottom fermenting yeast (usually by decoction mashing); originally
 SE, Oke TL Yates CL Copes RA. 1998. Effect of interventions on children's blood lead levels. Environ Health Perspect 106:79-83.

Hilts SR, Hertzman C, Marion SA. 1996. A controlled trial of the effect of HEPA vacuuming on childhood lead exposure. Can J Public Health 86(5):345-350.

HUD. 1996. Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing. HUD-1539-LBP. Washington, DC:U.S. Department of Housing and Urban Development,

Lanphear BP, Emond M, Jacobs DE, Weitzman M, Tanner The code name for the Xeon version of the Pentium III chip. See Xeon.  M, Winter NL, et al. 1995. A side-by-side comparison of dust collection methods for sampling lead-conteminated house dust. Environ Res 68:114-123.

Lanphear BP, Weitzman M, Winter NL, Eberly S, Yakir B, Tanner M, et al. 1996. Lead;contaminated house dust and urban children's blood lead levels. Am J Public Health 86(10):1416-1421.

Lioy PJ, Yiin L-M, Adgate J, Weisel C, Rhoads 6G. 1998. The effectiveness of a home cleaning intervention strategy in reducing potential dust and lead exposures. J Exp Anal Environ Epidemiol 8(1):17-35.

Reynolds SJ, Etre L, Thorne PS, Whitten P, Selim M, Popendorf WJ. 1997. Laboratory comparison of vacuum, OSHA OSHA
n.
Occupational Safety and Health Administration, a branch of the US Department of Labor responsible for establishing and enforcing safety and health standards in the workplace.
, and HUD sampling methods for lead in household dust. Am Ind Hyg Assoc J 58(6):439-446.

Rhoads GG, Ettinger AS, Weisel CP, Buckley TJ, Goldman KD, Adgate J, et al. 1999. The effect of dust lead control on blood lead in toddlers: a randomized trial. Pediatrics 103:551-555.

Rich DQ, Rhoads GG, Yiin LM, Zhang J, Bai Z, Adgate J, et al. 2002. Comparison of home lead dust reduction techniques on hard surfaces: the New Jersey Assessment of Cleaning Techniques (NJ ACT) Trial. Environ Health Perspect 110:889-893.

Roberts JW, Clifford WS, Glass G, Hummer PG. 1999. Reducing dust, lead, dust mites dust mite House dust mite, see there , bacteria, and fungi Fungi (fŭn`jī), kingdom of heterotrophic single-celled, multinucleated, or multicellular organisms, including yeasts, molds, and mushrooms. The organisms live as parasites, symbionts, or saprobes (see saprophyte).  in carpets by vacuuming. Arch Environ Contam Toxicol 36(4):477-484.

Rodes CE, Newsome JR, Vanderpool RW, Antley JT, Lewis RG. 2001. Experimental methodologies and preliminary transfer factor data for estimation of dermal dermal /der·mal/ (der´mal) pertaining to the dermis or to the skin.

der·mal or der·mic
adj.
Of or relating to the skin or dermis.
 exposures to particles. J Expos Anal Environ Epidemiol 11(2):123-139.

Sterling DA, Roegner KC, Lewis RD, Luke DA, Wilder LC, Burchette SM. 1999. Evaluation of four sampling methods for determining exposure of children to lead-conteminated household dust. Environ Res 81(2):130-141.

Thornton I, Davies DJ, Watt JM, Quinn MJ. 1990. Lead exposure in young children from dust and soil in the United Kingdom. Environ Health Perspect 89:55-60.

U.S. EPA. 1991. Standard Operating Procedures standard operating procedure Medtalk A technique, method or therapy performed 'by the book,' using a standard protocol meeting internally or externally defined criteria; a formal, written procedure that describes how specific lab operations are to be performed.  for Lead in Paint by Hotplate- or Microwave-Based Acid Digestion and Atomic Absorption or Inductively Coupled Plasma Emission Spectrometry Inductively Coupled Plasma Emission Spectrometry

A test method of quantitative identification of the elements, Aluminium, Silicon, Sodium, Vanadium, Nickel, Iron, Calcium, Zinc and Phosphorus in residual fuel oils.

A weighted test sample is prepared first by Ashing.
. PB92-114172. Research Triangle Park Research Triangle Park, research, business, medical, and educational complex situated in central North Carolina. It has an area of 6,900 acres (2,795 hectares) and is 8 × 2 mi (13 × 3 km) in size. Named for the triangle formed by Duke Univ. , NC:U.S. Environmental Protection Agency, Atmospheric Research Atmospheric Research (ISSN 0169-8095) is scientific journal dealing with the part of the atmosphere where meteorological events occur; intended for atmospheric scientists (such as meteorologists and climatologists), aerosol scientists, and hydrologists.  and Exposure Assessment Laboratory.

Wang YE This article or section may fail to make a clear distinction between fact and .
Please [ edit this article], according to the fiction guidelines, to meet Wikipedia's .
, Rhoads GG, Wainman T, Lioy PJ. 1995. Effects of environmental and carpet variables on vacuum sampler collection efficiency. Appl Occup Environ Hyg 10(2):111-119.

Lih-Ming Yiin, (1) George G. Rhoads, (1) David Q. Rich, (1,2) Junfeng Zhang, (1) Zhipeng Bai, (1,3) John L. Adgate, (4) Peter J. Ashley, (5) and Paul J. Lioy (1)

(1) Environmental and Occupational Health Sciences Institute, University of Medicine and Dentistry of New Jersey The University of Medicine and Dentistry of New Jersey is the state-run health sciences institution of New Jersey and comprises eight distinct academic units: the New Jersey Medical School, the New Jersey Dental School, the Graduate School of Biomedical Sciences, the School of , Robert Wood Johnson Medical School Robert Wood Johnson Medical School (often abbreviated RWJMS) is one of eight schools that comprise the University of Medicine and Dentistry of New Jersey (UMDNJ).

RWJMS operates three campuses in New Jersey, in Piscataway, New Brunswick and Camden.
, and Rutgers University Rutgers University, main campus at New Brunswick, N.J.; land-grant and state supported; coeducational except for Douglass College; chartered 1766 as Queen's College, opened 1771. Campuses and Facilities


Rutgers maintains three campuses.
, Piscataway, New Jersey, USA; (2) Environmental Epidemiology Program, Departments of Epidemiology and Environmental Health, Harvard School of Public Health The Harvard School of Public Health is (colloquially, HSPH) is one of the professional graduate schools of Harvard University. Located in Longwood Area of the Boston, Massachusetts neighborhood of Mission Hill, next to Harvard Medical School and Cambridge, Massachusetts, , Boston, Massachusetts “Boston” redirects here. For other uses, see Boston (disambiguation).
Boston is the capital and most populous city of Massachusetts.[3] The largest city in New England, Boston is considered the unofficial economic and cultural center of the entire New
, USA; (3) College of Environmental Science and Engineering, Nankai University Coordinates:  Founded in 1919 by renowned patriotic educationist Zhang Boling (1876-1951) and Yan Fansun (1860-1920), Nankai University is a member of the Nankai serial schools. , Tianjin, China; (4) Division of Environmental and Occupational Health, University of Minnesota School of Public Health The University of Minnesota School of Public Health, located in Minneapolis, Minnesota, is a professional school of the University of Minnesota. The school offers a 15 masters programs and four doctoral programs, which culminate in one of the following degrees: Master of Public , Minneapolis, Minnesota “Minneapolis” redirects here. For other uses, see Minneapolis (disambiguation).
Minneapolis (pronounced IPA: /ˌmɪniˈæpəlɪs/) is the largest city in the U.S.
, USA; (5) Office of Healthy Homes and Lead Hazard Control, U.S. Department of Housing and Urban Development, Washington, DC, USA

Address correspondence to L-M Yiin, 170 Frelinghuysen Road, EOHSI 234, Piscataway, NJ 08854 USA. Telephone: (732) 445-6942. Fax: (732) 445-0784. E-mail: lih-ming.yiin@umdnj.edu

This work was supported by HUD Grant NJLHR 0023-97 and by Center Grant ES05022 from the National Institutes of Health. Views expressed in this article are those of the authors and do not necessarily reflect the views of the agencies with which the authors are associated.

Received 5 April 2002; accepted 24 May 2002.
COPYRIGHT 2002 National Institute of Environmental Health Sciences
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2002, Gale Group. All rights reserved. Gale Group is a Thomson Corporation Company.

 Reader Opinion

Title:

Comment:



 

Article Details
Printer friendly Cite/link Email Feedback
Author:Lioy, Paul J.
Publication:Environmental Health Perspectives
Geographic Code:1U2NJ
Date:Dec 1, 2002
Words:6013
Previous Article:Expression of hsp 27, hsp 60, hsc 70, and hsp 70 stress response genes in cultured human urothelial cells (UROtsa) exposed to lethal and sublethal...
Next Article:DDT and its metabolites alter gene expression in human uterine cell lines through estrogen receptor-independent mechanisms.



Related Articles
New technologies offer safe building cleaning.
Furnishings/interiors - products.(1999 Buyers Guide)(Buyers Guide)
A Pilot Study Examining Changes in Dust Lead Loading on Walls and Ceilings after Lead Hazard Control Interventions.
Effects of physical interventions on house dust mite allergen levels in carpet, bed, and upholstery dust in low-income, urban homes. (Articles).
Analysis of aggregate exposure to chlorpyrifos in the NHEXAS-Maryland investigation. (Articles).
Comparison of home lead dust reduction techniques on hard surfaces: the New Jersey assessment of cleaning techniques trial. (Articles).
Dust: a metric for use in residential and building exposure assessment and source characterization.
Multisurface cleaning system. (Product Spotlight).(from Rug Doctor Pro)(Brief Article)
Assessment of cleaning to control lead dust in homes of children with moderate lead poisoning: treatment of lead-exposed children trial. (Children's...
Here's how to reduce a child's exposure to asthma-provoking factors.(The Best Of The Green Guide)(Brief Article)

Terms of use | Copyright © 2009 Farlex, Inc. | Feedback | For webmasters | Submit articles