Bioelectrical impedance of meridians using low frequency electro-acupuncture.



Introduction

According to according to
prep.
1. As stated or indicated by; on the authority of: according to historians.

2. In keeping with: according to instructions.

3.
 eastern medicine, sometimes identified as traditional Chinese medicine Traditional Chinese Medicine Definition

Traditional Chinese medicine (TCM) is an ancient and still very vital holistic system of health and healing, based on the notion of harmony and balance, and employing the ideas of moderation and prevention.
 (TCM (1) (Trellis-Coded Modulation/Viterbi Decoding) A technique that adds forward error correction to a modulation scheme by adding an additional bit to each baud. TCM is used with QAM modulation, for example. ), meridians are biological pathways bridging special points named acupuncture points (APs). Results of recent tests by various researchers have allegedly shown differences in the bioelectric bi·o·e·lec·tric   also bi·o·e·lec·tri·cal
adj.
1. Of or having to do with the electric current generated by living tissue.

2. Of or relating to the effects of electricity on living tissue.
 properties of meridians versus their peripheral tissues, with some tests indicating that the impedance of needled points precisely over a meridian is lower than in neighbouring non-meridian points.

TCM uses acupuncture to alleviate pain, as well as decrease and remedy disease, as has been documented in eastern medicine literature. The clinical practice of acupuncture originated in East Asia East Asia

A region of Asia coextensive with the Far East.



East Asian adj. & n.
 and is the most well-known complementary medicine modality(1,2). Since the spread of evidence-based western medicine, a good deal of research has been undertaken to establish the effectiveness of complementary medicine using western-based science.

In keeping with TCM theory, meridians are conduits for the flow of vital energy, also called Qi, in the body. The name of each meridian is based on the vital organ that a meridian passes through, such as kidney meridian (K) or small intestine small intestine

Long, narrow, convoluted tube in which most digestion takes place. It extends 22–25 ft (6.7–7.6 m), from the stomach to the large intestine.
 meridian (SI). At the centre of TCM's Qi flow theory is the assertion that pains and diseases related to these vital organs can be treated by applying acupuncture to specific points on meridians. These points have different biological properties.

Our study was aimed at investigating the differences in the bioelectrical properties of selected points on specific meridians and an equal number of non-meridian points in the same vicinity. One study of cardiovascular patients showed that thermal energy density was higher on the skin route along the heart meridian. Furthermore, tungsten light passing between two APs of the pericardium pericardium: see heart.  meridian was 20% brighter than on a similar off-route in peripheral tissues ie, non-meridian(3,4).

Research has been previously conducted on the identification of APs and treatment of diseases concerning biological parameters, including bioelectrical impedances(5). Ahn et al's review of past research reported lower surface impedance around APs compared with their peripheral points(6).

Although most of the previous studies were non-invasive with only a few being invasive, the aggregate outcome only yielded more controversy(7). The issue yet to be resolved is firstly, whether different electrical properties exist between meridians and non-meridians and secondly, whether this difference can enhance the understanding of how acupuncture can be used to treat disease or assist patients with pain relief.

This experimental set-up was designed to enable replication in future studies. Its objective was to consider the complex electron interactions in biological elements along meridians that show electrical properties, and to illustrate how these might differ from non-meridians. These electric properties have the potential to contribute to bioelectric impedance.

Taking this approach, our study was planned to evaluate electrical impedances of a 4-electrodes invasive treatment strategy. The results obtained were recorded, plotted, tabulated and analysed and the outcome is presented in this paper.

Subjects And Methods

The procedures used in this study complied with the World Medical Association Declaration of Helsinki For the political accords, see .
. There is also another Declaration of Helsinki, dealing with the Information Society.[1] Introduction
The Declaration of Helsinki,[2] was developed by the World Medical Association[3]
 on Ethical Principles for Medical Research Involving Human Subjects. The criteria for acupuncture points and the experimental method were submitted to the appropriate authorities at Azad University, Teheran, Iran, to obtain permission to conduct this research on human subjects. The entire experiment was carried out in the Bioelectric Laboratory Building of the Biomedical Engineering Biomedical engineering

An interdisciplinary field in which the principles, laws, and techniques of engineering, physics, chemistry, and other physical sciences are applied to facilitate progress in medicine, biology, and other life sciences.
 Faculty of Azad University.

Careful consideration was given to the selection of candidates. To keep variables controlled, only healthy male subjects were selected. There were 40 tests conducted on eleven male subjects aged between 25 and 35-years old. Preliminary screening was applied to exclude subjects with cardiac, stomach or digestive disease. Furthermore, any volunteers with a history of pain or surgery in the relevant meridian, or its peripheral, or corresponding non-meridian control sites, were excluded. Also, those volunteers with sensitivity to needle insertion were not included in this study.

The procedure commenced by removing hair from the subjects in the areas that were to be needled. These areas were sterilised using alcohol. Every subject was allowed to rest in a relaxed position for five to twenty minutes while the procedure was explained to them. Standard off-the-shelf disposable steel acupuncture needles were used. These needles also acted as the output voltage-recording probes. The duration of each test was approximately 24-30 minutes.

The impedances for meridian and non-meridian biological pathways were calculated using the data acquired after stimulating the points as detailed above. This method, also known as the frequency response method, has been in use since the early nineteenth century, hence it is universally acceptable among biomedical bi·o·med·i·cal
adj.
1. Of or relating to biomedicine.

2. Of, relating to, or involving biological, medical, and physical sciences.
 and electrical engineers as a reliable modus operandi [Latin, Method of working.] A term used by law enforcement authorities to describe the particular manner in which a crime is committed.

The term modus operandi is most commonly used in criminal cases. It is sometimes referred to by its initials, M.O.
. Our aim in using this method was that, by injecting an electrical current with a known and controlled frequency which measures output voltage, it would yield sufficient data for assessing the impedance.

The selection of test points considered: location and direction of the meridian route; ease of probing; relative spacing between points with respect to other meridians to minimise inter-meridian and intra-meridian inaccuracy; potential harm or side effects Side effects

Effects of a proposed project on other parts of the firm.
 whilst needling; whether hair could be removed prior to probing if it existed; adequate clearance from peripheral; and the presence of different bio-matrices under the needling site for getting distinct biological conditions. Moreover, subjects were given a rest period of twenty minutes prior to needling in an attempt to settle any anxiety or fear in anticipation of the procedure.

Based on ease of access to the segments, as well as relative popularity in acupuncture practice, three meridians and their segments were chosen for this study. These meridians were pericardium (Ximen PC-4 to Daling PC-7), stomach (Zusanli ST-36 to Xiajuxu ST-39), and spleen (Chongmen SP-12 to Fuai SP-16). These were APs with distances between 1 Tsun and 3 Tsun on selected parts of meridians, and were quoted frequently in text books as effective points used in clinical practice.

Non-meridian needled points were located on a parallel line to the meridians in a position relative to the APs. These non-meridian points provided a comparison with the sample segments of meridians in different body locations: foot, hand and trunk. Each of these locations has different biological properties, electro-sensitivities, bioelectrical characteristics and impedance responses to stimulation.

The impedance was evaluated using Ohm's Law applied to the 4-electrodes measurements. An electrical current was passed through two outer points, and the electric potential across the two inner points was measured (admittance Admittance

The ratio of the current to the voltage in an alternating-current circuit. In terms of complex current I and voltage V, the admittance of a circuit is given by Eq. (1), and is related to the impedance of the circuit Z by Eq. (2).
 evaluation).

An advantage of applying the 4-electrodes technique compared with the 2-electrodes technique was the uniformity of current flow at the receiving sites. Due to possible electrochemical exchange between tissue and electrodes, this 4electrodes technique was preferred. In this technique, entry and exit points of the electrical current were assumed as outer points that received voltage.

Since concurrent measurement of meridian and non-meridian voltages were conducted in this study, the 4-electrodes set-up had to be improved. After the needles were inserted in-vivo, the real-time measurement of current through the predicted routes and voltage read-outs were concurrently recorded. This was achieved by simultaneously using the 2needle electrodes for current entry, and another 2-probed electrode points for measuring voltage on meridian APs and non-meridian control points.

The current was produced by a voltage regulator and placed 20 mm away from the midline mid·line
n.
A medial line, especially the medial line or plane of the body.


midline,
n the line equidistant from bilateral features of the head.
 of the path that linked the meridian and non-meridian routes. The current was limited to 60 [micro]A in amplitude with 2 Hz to 2000 Hz stimulation frequency range. Currents and voltages were recorded non-sequentially in frequency multiples of two, five and ten to minimise the harmonic effect and adaptation of live reactivation and galvanic response.

The current passing through tissues and output voltage from needles was recorded using a data acquisition system (BIOPAC Systems, Inc., Santa Barbara, CA 93117 USA). The data was monitored on a computer in real-time and then passed through a software filter known as Hamming. This was used to enable computation of the impedance as well as observation of any phase change in the frequency response, otherwise known as Bode plots.

The results of all the tests ie, pericardium, stomach and spleen meridians from points PC-4 (Ximen) to PC-7 (Daling) on the arm, ST-36 (Zusanli) to ST-39 (Xiajuxu) on the leg, and SP-12 (Chongmen) to SP-16 (Fuai) on the trunk, were recorded and saved. Non-meridian points were distanced no less than 10 mm alongside their parallel meridian points.

[FIGURE 1 OMITTED]

There were six electrodes, including two for current entry and four for simultaneous voltage-recording of meridian and non-meridian points, as derived from the classic 4-electrodes technique. Using such a set-up allowed for a synchronous measurement of the impedance components for meridian and non-meridian pathways. The resulting data was filtered and stored ready for post-processing and further analysis.

To enhance signal:noise ratio and minimise any undesired interference effect on cell matrix and remote tissue, the sinusoidal sinusoidal /si·nus·oi·dal/ (si?nu-soi´dal)
1. located in a sinusoid or affecting the circulation in the region of a sinusoid.

2. shaped like or pertaining to a sine wave.
 current amplitude was set at 10-60 [micro]A. This minute applied current created voltages in the surrounding tissue in the order of a millivolt mil·li·volt
n. Abbr. mV
A unit of potential difference equal to one thousandth (10-3) of a volt.



millivolt

one-thousandth of a volt; abbreviated mV.
 range which was considered safe.

The recorded amplitude and phase of input and output signals were stored for computation of impedance using Ohm's principles. Ohm's law states that the amount of current through a medium is directly related to the electrical potential difference or voltage across the medium, and is inversely proportional to the resistance in between. The current and voltage peak amplitudes were measured and post-processed by applying a Hamming filter.

A sample of a signal recorded at a distance of 3 Tsun on the stomach meridian after passing the software filter is illustrated in Figure 2. The inserted current was 25 [micro]A with a frequency of 5 Hz as signified in the top graph. The second and third graphs indicate voltages from the meridian and its pathway parallel non-meridian, respectively.

The values of recorded impedances at different frequencies were plotted on a Bode plot using MATLAB (MATrix LABoratory) A programming language for technical computing from The MathWorks, Natick, MA (www.mathworks.com). Used for a wide variety of scientific and engineering calculations, especially for automatic control and signal processing, MATLAB runs on Windows, Mac and  software Ver.7.0. Figure 3 shows a sample of a Bode plot for the tests conducted at various distances on meridian and non-meridian points on the foot, hand, and trunk on the pericardum, stomach, and spleen meridians. All the tests yielded similar pattern diagrams. The meridian and non-meridian impedance changes were analysed for frequencies from 2 Hz to 2000 Hz. The minimum impedance amplitude was observed to be in the 15-55 Hz frequency range. Furthermore, the focal phase changes were evident in this range.

[FIGURE 2 OMITTED]

[FIGURE 3 OMITTED]

Results

The results indicated that there was significant non-linearity between the distances and recorded values of two probed biological locations, even with measurements carried out on the same subject. Application of the Bode plot to the data allowed assessment of the meridian and non-meridian impedances to be compared within the 15-55 Hz frequency range.

Larger differences were evident at frequencies lower than 60 Hz. It was noted that meridian impedance was lower at some frequencies (resonant frequency resonant frequency,
n the specific frequency at which an object vibrates.
), and the value of impedance was at its minimum when the meridian and non-meridian phase sign switched polarity.

The tests were of an invasive nature; hence stimulation and recordings were classified as in-vivo data. The invasive needling tests showed insignificant differences in impedances of meridian and non-meridian pathways at high frequencies. In contrast, a notable difference was evident for frequencies lower than about 55 Hz with mean differences as high as 40% with a minimum of at least 14%. The resonance frequency for meridians and non-meridians averaged 23-43 Hz (p<0.005).

The results showed that the maximum impedance difference between meridian and non-meridian pathways occurred at frequencies lower than 40 Hz. At the frequencies where impedance of meridians and non-meridians was at its lowest, ie, resonance frequencies, test results indicated statistically significant differences in the recordings. This feature can be used to identify meridian and non-meridian pathways. Furthermore, the clear difference observed between meridians and non-meridians in the lower frequency range confirmed TCM practitioners' assertion of lower frequencies yielding better outcomes. Similar findings were reported by other investigators(6).

This kind of practical methodology effectively permitted a real-time assessment of the biological impedance components at the probed sites; hence, a means of demonstrating differences in biological pathways in-vivo. The outcome of this study can be replicated using electro-acupuncture stimulation equipment as used by acupuncturists. Such devices are capable of generating selectable frequencies; however; the waveform shape needs consideration as it may also be important.

One practical issue when treating a patient with electro-acupuncture is the application of a safe level of electric current to APs. The safe level relates to both frequency and amplitude which is dependent on the waveforms. Figure 4 shows typical waveforms generated by commercial devices. Saw-tooth waveforms cover a greater frequency spectrum.

[FIGURE 4 OMITTED]

Fourier Transform technique, when applied to such waveforms, can demonstrate this characteristic*50. The Fourier Transform technique is a means of analysing a complex signal into its oscillatory oscillatory

characterized by oscillation.


oscillatory nystagmus
see pendular nystagmus.
 components, thereby enabling the experimenter to calculate the fundamental frequency and the component frequencies. Conversely, the period of such types of treatment to waveforms in time domain contains two modes of high and low repeat frequencies.

According to practitioners' anecdotal claims, the frequency of 5 Hz returns worsening and/or extended motor muscles. Accordingly, frequencies of 50-100 Hz have been applied by acupuncturists in eliminating anesthesia, senselessness, and related tenderness of muscle or muscle spasm muscle spasm
n.
Persistent increased tension and shortness in a muscle or group of muscles that cannot be released voluntarily.


muscle spasm,
n
. A combination of these frequencies has been used for relatively complicated treatments depending on the individual patients' biological responses.

Furthermore, the 50-100 Hz frequency range has been applied to improve limb activities, tissue reproduction and digestion, as well as to decrease vein inflammation, swelling in muscles and joints, and clear vein or meridian clogging. For acute conditions, such as paralysis and similar syndromes, discrete repeated frequencies have been used(8).

Even the waveforms can have different types as shown in the sample waveforms used in practice in Figure 4. All the anecdotal evidence anecdotal evidence,
n information obtained from personal accounts, examples, and observations. Usually not considered scientifically valid but may indicate areas for further investigation and research.
 points to finer treatment responses to electro-acupuncture stimulation being achieved when frequencies lower than 100 Hz are used.

Our observations indicate that the main difference between meridians and non-meridians is restricted to frequencies lower than 50 Hz. Perhaps this could explain why an improved treatment response is experienced when lower frequency settings are applied in clinical practice. This western scientifically-designed study, with its unique approach using a biomedical engineering technique, conformed with the practical results of electro-acupuncture.

The observed higher resistance of non-meridian pathways, especially in lower frequencies when compared with meridians, could be accepted as the scientific rationale for observing lesser biological affectability when invasive electroacupuncture is applied to the body for the purpose of treating health conditions.

Discussion

In this study, the electrical componential impedance of three meridians was evaluated and the values were compared with their neighbouring non-meridian impedances in the frequency range of 2 hz to 2000 Hz. The similarities and differences observed in the result and graph patterns were analysed. The meridians and non-meridians had a resonant frequency of about 20 Hz and 45 Hz, respectively, and the differences were more noticeable in frequencies lower than the resonance.

The major difference between the meridian and non-meridian impedance components was distinct. It is concluded that the functional operation range is in the lower than resonance frequencies which is quantified to be generally less than 50 Hz. These results were consistent with anecdotal claims from electro-acupuncture practitioners and their patients--that high period excitation is most effective for treatment.

The high period excitation is effectively low frequency stimulation. The devices used in practice have a frequency range up to 0.8 kHz, but frequencies far lower than that may be useful depending on the location of the meridian being needled. The treatment capacity of electro-acupuncture devices may be justified for certain categories of cases such as neuro-and musculo-skeletal pains if the results of this study relate to categories of bioelectrical pain signal pathways.

Different results with different meridians add to the complexity of scientific reasoning. Comparing our results of three meridians with different sub-neighbourhood tissues (arterial, neural, skeletal and adipose adipose /ad·i·pose/ (ad´i-pos)
1. fatty.

2. the fat present in the cells of adipose tissue.


ad·i·pose
adj.
Of, relating to, or composed of animal fat; fatty.
), revealed that there was no direct relationship between the characteristics of tissue matrices and meridian impedance parameters.

Any scientific explanation of differing biological results when needling and stimulating two locations on the body, even 1 Tsun apart, must relate to the natural constituents of the locale. The tissues can be nervous, muscular, epidermal Epidermal
Referring to the thin outermost layer of the skin, itself made up of several layers, that covers and protects the underlying dermis (skin).

Mentioned in: Antiangiogenic Therapy, Histiocytosis X


epidermal
 or connective and have cell arrays. They are connected to peripheral tissues via connecting tissues and create cell matrices.

Some research revealed that the quantity of the mast cell mast cell
n.
A cell found in connective tissue that contains numerous basophilic granules and releases substances such as heparin and histamine in response to injury or inflammation of bodily tissues. Also called labrocyte, mastocyte.
 was more concentrated under the meridian lines vis-a-vis their control areas (1011). Also, water molecule polarity could make a low impedance pathway(12). Therefore, a meridian pathway might have a different characteristic according to special streamlining of water molecular polarity along the trail.

On the other hand, grasp in needled APs has more momentum force in comparison to peripheral control points(13). The different biomechanical parameters can be due to structural differences of tissues in meridian and non-meridian pathways. More research at the sub-tissue level is needed to understand this phenomenon. In particular, further evidence is required to understand and explain the similarity in impedance of meridians and non-meridians at higher frequencies.

An analysis may be necessary to investigate the relationship of the low frequency range to the energy flow. This may create a means of understanding TCM theory of Qi conducted by meridians and not through non-meridian pathways, and the transfer of Qi between APs of the vital organs that the meridians have been named after. This study should assist with understanding human biology from an eastern medicine viewpoint as well as redefine the concept with western sciencebased theory. Ultimately, the two medicinal practices will complement each other in working towards improving health.

References

(1) Konofagou EE, Langevin HM. Using ultrasound to understand acupuncture. IEEE (Institute of Electrical and Electronics Engineers, New York, www.ieee.org) A membership organization that includes engineers, scientists and students in electronics and allied fields.  Engineering in Medicine and Biolology 2005;24(2):41-6.

(2) Shang C. The past, present and future of meridian system research. Clinical Acupuncture and Oriental Medicine 2000;1(2):115-24.

(3) Apopp F, Oehler WM, Schlebusch KP, Klimex W. Evidence of light piping (meridian-like channels) in the human body and nonlocal EMF emf: see electromotive force.


(1) (ElectroMagnetic Field) See electromagnetic radiation.

(2) (Enhanced MetaFile) See Windows metafile.
 effects. Electromagnetic Biology and Medicine 2005;24(3):359-74.

(4) Kim JB, Lee SM, Choi C, Kim YB, Yoon G. Propagated photon detection at PC6 irradiating along the pericardium meridian. IEEE Lasers and Electro-Optics 2001;2(2)302-3.

(5) Chen KG. Electrical properties of meridians; with an overview of electro-dermal screening test. IEEE Engineering in Medicine and Biology 1996;15(3):58-63.

(6) Ahn AC, Colbert AP, Anderson BJ, Martinsen OG, Hammerschlag R, Cina S, Wayne PM, Langevin HM. Electrical properties of acupuncture points and meridians: a systematic review. Bioelectromagnetics 2008;29:245-56.

(7) Cosic I, Cvetkovic D, Fang Q, Lazoura H. Human physiological signal responses to ELF Schumann resonance Schumann resonance,
n.pr the sum total of all electromagnetic vibrations and waves between the earth and the ionosphere. The energy originates from lightning strikes.
 and artificial electromagnetic fields. FME FME Formal Methods Europe
FME Faculty of Mechanical Engineering (Brno University of Technology, Czech Republic)
FME Feature Manipulation Engine
FME Facultat de Matemàtiques I Estadística
 Transactions, 2006;34:93-103.

(8) Dharmananda S. Electro-acupuncture. Institute for Traditional Medicine, 2002.

(9) Kenion JJ. Health touch: technical and research information.

Kodiak Health Products, 1995.

(10) Zhu Z, Xu R. Morphometric observation on the mast cells under the acupuncture meridian lines. Zhen Ci Yan Jiu, 1990;15(2):157-8.

(11) Tabosa A, Yamamura Y, Forno ER, Mello LEAM. Effect of the

acupoints acupoints,
n.pl particular bodily locations that allow practitioners to balance client's qi to affect therapeutic changes with acupuncture or acupressure. See also acupressure, acupuncture, meridians, qi, and tsubo.
 ST-36 (Zusanli) and SP-6 (Sanyinjiao) on intestinal myoelectric The electrical signals within the human body that stimulate the muscles to move. The signal, which is less than one millivolt, has an average frequency of about 100Hz. Myoelectric signals are used to move prosthetic limbs.  activity of Wistar rats. Brazilian Journal of Medicine and Biological Research 2002;35(6):731-9.

(12) Oschman JL. Energy medicine: the scientific basis. Churchill Livingston, 2000.

(13) Langevin HM, Churchill DL, Fox JR, Badger GJ, Garra BS, Ktag MH. Biomechanical response to acupuncture needling in humans. Journal of Applied Physiology 2001;91(6)2471-8.

S. Mohammad Ali Riyazy [1], Farzad Towhidkhah [2], Mohammad Hassan Moradi [2] and Hassan Ali Sadafi [3]

[1] Bio-Electric Group, Faculty of Biomedical Engineering, Science and Research Branch of Islamic Azad University Islamic Azad University (Persian: دانشگاه آزاد اسلامی , Dāneshgāh-e Āzād-e Eslāmi) is a private chain of universities in Iran. , Teheran, Iran.

[2] Faculty of Biomedical Engineeing, Amirkabir University of Technology Amirkabir University of Technology (AUT, دانشگاه صنعتی امیرکبیر), formerly named Tehran Polytechnic , Teheran, Iran.

[3] Murdoch Childrens Research Institute, The Royal Children's Hospital The Royal Children's Hospital in Melbourne, Australia is the major specialist paediatric hospital for Victoria offering a full range of clinical services, tertiary care and health promotion and prevention programs for children and adolescents. , Melbourne, Australia.

Correspondence: Hassan Ali Sadafi, telephone (03) 9936 6666, fax (03) 9348 1391, hassan.sadafi@mcri.edu.au.
COPYRIGHT 2009 Australian Traditional-Medicine Society
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2009 Gale, Cengage Learning. All rights reserved.

 Reader Opinion

Title:

Comment:



 

Article Details
Printer friendly Cite/link Email Feedback
Author:Riyazy, S. Mohammad Ali; Towhidkhah, Farzad; Moradi, Mohammad Hassan; Sadafi, Hassan Ali
Publication:Journal of the Australian Traditional-Medicine Society
Article Type:Clinical report
Geographic Code:8AUST
Date:Dec 1, 2009
Words:3307
Previous Article:Company secretary's report.
Next Article:Effect of auricular pellet acupressure on diabetes mellitus.