A better way to cable buildings.


Take a look at a common network and cabling infrastructure.

As stated in a recent article for BICSI (Building Industry Consulting Service International, Tampa, FL, www.bicsi.org) An international telecommunications association providing education, registration and resources for professionals involved in the design and installation of low-voltage distribution systems in commercial and , "Several things are happening in our industry that will change the way we cable and build networks in the future ... construction specifications are being written to include the telecommunications Communicating information, including data, text, pictures, voice and video over long distance. See communications.  pathways, spaces and cabling ... the cabling for the control and monitoring of BAS BAS
abbr.
1. Bachelor of Agricultural Science

2. Bachelor of Applied Science
(building automation system), such as fire, security, and heating, ventilating ventilating

Natural or mechanically induced movement of fresh air into or through an enclosed space. The hazards of poor ventilation were not clearly understood until the early 20th century. Expired air may be laden with odors, heat, gases, or dust.
 and air conditioning air conditioning, mechanical process for controlling the humidity, temperature, cleanliness, and circulation of air in buildings and rooms. Indoor air is conditioned and regulated to maintain the temperature-humidity ratio that is most comfortable and healthful.  (HVAC (Heating Ventilation Air Conditioning) In the home or small office with a handful of computers, HVAC is more for human comfort than the machines. In large datacenters, a humidity-free room with a steady, cool temperature is essential for the trouble-free ) is also being integrated with the telecommunications cabling" design.

The reason this integration has taken so long to occur, especially in U.S. markets, lies mainly in the master plan development procedures, and the new construction and renovation building processes. The ability for a building owner, property manager or the CFO See Chief Financial Officer.  of a corporation to be able to address the deployment of a common network for all building systems into a project, in terms of both time and money, has been retarded re·tard·ed  
adj.
1. Often Offensive Affected with mental retardation.

2. Occurring or developing later than desired or expected; delayed.
 by the separateness of the traditional bid-process itself. The development of 1 + GB copper and 10 GB fiber-optic cabling systems for voice, video and data clearly lends itself to the integration and deployment of the BAS applications for all commercial buildings.

The development of the PathMAX pathway pathway /path·way/ (path´wa)
1. a course usually followed.

2. the nerve structures through which an impulse passes between groups of nerve cells or between the central nervous system and an organ or muscle.
 system products has made providing an integrated (partitioned par·ti·tion  
n.
1.
a. The act or process of dividing something into parts.

b. The state of being so divided.

2.
a.
) cable delivery system possible for all low- and high-voltage cable for a commercial building. This engineering technique allows for the integration of the required electrical distribution system into a partitioned raceway with all of the required low-voltage building systems cable.

By integrating the voice, data, BAS and the electrical distribution systems cabling into a common pathway Common pathway
The pathway that results from the merging of the extrinsic and intrinsic pathways. The common pathway includes the final steps before a clot is formed.
 system, a building owner can expect that a single installation crew can provide one cable delivery system method on which to connect all required network applications. This also eliminates a duplication duplication /du·pli·ca·tion/ (doo-pli-ka´shun)
1. the act or process of doubling, or the state of being doubled.

2.
 of effort of six to eight system installation work crews and four to five cable delivery methods, which are usually part of the purchase and installation price for each voice and data, and BAS system. This will have a significant impact on both time and cost of the implementation phase of a commercial building project.

What else is new? The deployment of structured-system zone cabling into commercial spaces has become a requirement, with property managers wondering why it was not made available 10 years ago. Azone cabling design can live in both a raised access floor area (including the new low profile 2" to 4" floor systems) or in the ceiling areas above the commercial space. A mathematical matrix can be constructed to provide the correct number of service connections (I/Os) for all low- and high-voltage systems. This design approach, combined with the new pathway products, sets the stage for a common network and cabling infrastructure for commercial buildings.

Probably the most important outcome of common network and building systems integration has been in the operational phase of the building project. This phase is seldom considered in master planning of a new or renovated building project. What is important to note, however, is the impact of the operational expense (cost to operate/sq, ft.) of the commercial space, when the flexibility of the building's infrastructure is considered in the master plan.

When you compare traditional nonintegrated infrastructure components with an integrated solution, and project the cost of management and change over a five- and 10-year operational cycle, the expectation of a 40% to 60% operational systems cost reduction can be obtained. This capability also includes a well-defined investment protection quality for a property manager's cabling infrastructure. This is significant when you consider that the operational phase of a building is about 40 years in length and contains the majority of the expense.

Finally, commercial building cabling systems will be required to support the ever-increasing speeds of the gigabit networks; therefore, a cabling system infrastructure must be capable of not only high-speed performance, but a wide selection of system application capability. How the commercial facility is built will determine how much it will cost to live there.

Fortin is a member of the Bell Laboratories' technical staff in the systems engineering group for SYSTIMAX structured connectivity solutions at Lucent Technologies, Hunt Valley, MD.
COPYRIGHT 2000 Nelson Publishing
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2000 Gale, Cengage Learning. All rights reserved.

 Reader Opinion

Title:

Comment:



 

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:Technology Information
Comment:A better way to cable buildings.(Technology Information)
Author:Fortin, Bill
Publication:Communications News
Geographic Code:1USA
Date:Sep 1, 2000
Words:691
Previous Article:Latest wireless and mobile computing products.(Industry Trend or Event)
Next Article:Cable management adopts 21St-century technology.(Industry Trend or Event)
Topics:



Related Articles
Offering the highest speeds yet for Internet access.(First Quarter Review)(Habitat Communications)
The right cabling prescription.(Company Operations)
NY gets wired for high-speed Internet access.(Brief Article)
Fiber installation aids gene research.(at)(Technology Information)
ROBOT LAYS FIBRE-OPTIC CABLE IN SEWER SYSTEMS.(Company Business and Marketing)
Firm structures LAN cabling system.(Product Information)
Legislature votes on a cabling solution.(Government Activity)
Fiber-Optics Firms Pursue Military Local-Area Business.
Install the ultimate LAN: GigE supported by millions of feet of CAT 6 copper cable. (Cabling/wiring and cabinets: gigabit ethernet).
Cabling industry meets Jan. 21-24: emerging applications follow historical demands for more. (Cabling, Wiring and Enclosures).

Terms of use | Copyright © 2008 Farlex, Inc. | Feedback | For webmasters | Submit articles