2-D or 3-D inspection: do you have to choose? Flexibility in x-ray inspection combines 2-D real-time imaging with 3-D axial computed tomography.The role played by x-ray systems in the inspection of today's electronic assemblies is well understood. Unlike machine vision and optical inspection equipment, x-ray systems penetrate materials to expose hidden solder joints on area array devices. Once a need for x-ray inspection equipment has been determined, the next question is: Which is best for the application--two-dimensional (2-D) or three-dimensional (3-D) imaging? 2-D vs. 3-D Imaging For most applications, 2-D x-ray systems serve the need, providing a top-down image of the board or package being viewed. More advanced systems also offer the ability to inspect for defects by rotating the part being inspected at oblique angles to the x-ray beam x-ray beam, n the spatial distribution of radiation emerging from a radiograph generator or source. The colloquial term for radiographic beam. See radiographic beam. . The target area--the component or interconnect being checked for a defect--can thus be viewed from multiple orientations. Two-dimensional (2-D) systems consist of: a) an x-ray source (sealed or open tube), b) a fixture for holding and manipulating the part being inspected (sample) and c) the radiation detector. While x-ray tubes are available in various configurations and performance capabilities, open microfocus tubes are used primarily for the high-resolution requirements of electronics assembly and packaging. Such tubes can provide a spatial resolution (Data West Research Agency definition: see GIS glossary.) A measure of the accuracy or detail of a graphic display, expressed as dots per inch, pixels per line, lines per millimeter, etc. It is a measure of how fine an image is, usually expressed in dots per inch (dpi). in the range of 1 [micro]m, with geometrical magnifications up to 2400x. [FIGURE 1 OMITTED] An open tube is a stainless steel stainless steel: see steel. stainless steel Any of a family of alloy steels usually containing 10–30% chromium. The presence of chromium, together with low carbon content, gives remarkable resistance to corrosion and heat. tube in which a vacuum is continuously created, while a sealed tube is generally a tube in which the vacuum is created at the time of manufacture. Sealed tubes may not offer as sharp an image as open tubes. They are also less suitable for high magnification applications because of the larger minimum distance required from the focal spot focal spot, n See spot, focal. focal spot the area on the target of the x-ray tube which the electron stream strikes and from which x-rays are emitted. Called also focus. to the object and usually have a shorter life due to consumption of the electron gun A device that creates a fine beam of electrons that is focused on a phosphor screen in a CRT. (filament filament, in astronomy: see chromosphere. ). The manipulator is a device for x-y-z positioning and rotating/tilting of the sample with precision. The manipulator should be capable of directional and rotational speeds that can be varied for requirements ranging from quick overview searches at low magnification to very low speeds at high magnification. The detector processes the information of the x-ray image in real-time into an image of visible light that can be observed and assessed by the human eye. While the most common detector is a combination of video camera and image intensifier in·ten·si·fi·er n. Grammar See intensive. intensifier Noun a word, esp. an adjective or adverb, that intensifies the meaning of the word or phrase that it modifies, for example, very that converts the x-rays into visible light, other types of detectors recently developed include high-dynamic cameras and flat panel direct digital detectors (DDDs). The primary advantage of 2-D x-ray inspection is the savings in time in viewing an image, as 3-D analysis can take twice as long, or even longer. The primary limitations of 2-D systems become apparent when imaging double-sided boards. Since x-rays penetrate through components on both sides of the board, the devices on one side can be partially obscured by devices on the other side. Oblique angle imaging can lessen, and even eliminate, the problem, depending on the x-ray system and the complexity of the assembly being inspected. The most notable advantage of 3-D x-ray inspection is that it results in a complete picture of the area of concern. Solder balls, for instance, on the underside of ball grid arrays (BGAs) can be viewed from all sides, and defects, such as insufficiently wetted or cracked balls, can be easily identified. So, do you need 2-D or 3-D imaging? The requirement may not always be known until the middle of the inspection procedure, or the requirement may change. An x-ray system that offers both capabilities may be the ideal solution for the majority of applications. Combining 2-D and 3-D An ideal system that combines 2-D and 3-D imaging would incorporate a choice of: a) a standard open microfocus tube or b) a multifocus tube, which enables the operator to select either a microfocus, nanofocus or high-power mode, depending on the requirements of the application. The system would perform high-resolution 2-D inspection for optimum processing speed See MHz. , while enabling the operator to switch to 3-D for inspection of parts and interconnects that cannot be adequately viewed using 2-D. Inspecting with 3-D Three-dimensional capability can be achieved with a process called axial computed tomography Computed tomography (CT scan) X rays are aimed at slices of the body (by rotating equipment) and results are assembled with a computer to give a three-dimensional picture of a structure. (ACT) with volume rendering Volume rendering is a technique used to display a 2D projection of a 3D discretely sampled data set. A typical 3D data set is a group of 2D slice images acquired by a CT or MRI scanner. Usually these are acquired in a regular pattern (e.g. software. ACT is a reconstruction technology. By taking multiple 2-D views and by calculating the volume data (voxels), a 3-D image is constructed. Typically, for 3-D inspection, the region of interest (ROI (Return On Investment) The monetary benefits derived from having spent money on developing or revising a system. In the IT world, there are more ways to compute ROI than Carter has liver pills (and for those of you who never heard of that expression, it means a lot). ) of the part or interconnect is first located. Then, a multitude of images is taken in a 360[degrees] circle by rotating the sample and the x-ray beam being projected in a cone, as can be seen in Figure 1. Using software, the images are subsequently recombined into a 3-D visualization model. The manipulator for the 2-D/3-D x-ray system would enable movement around six axes, the movement being either programmed by computer numeric control (CNC (Computerized Numerical Control) See numerical control. CNC - Collaborative Networked Communication ) or controlled with a joystick. The multiple axes, thus, would provide flexibility in positioning the sample for optimum imaging. The high accuracy of the axis allows precise point-to-point measurements in 2-D mode. In 3-D mode, wall thickness or void volume measurements can be performed directly from the 3-D model due to the known size of the voxel data. The combined 2-D/3-D system should let the operator shift from one mode to the other easily. Thus, if a BGA (Ball Grid Array) A popular surface mount chip package that uses a grid of solder balls as its connectors. Available in plastic and ceramic varieties, BGA is noted for its compact size, high lead count and low inductance, which allows lower voltages to be used. , for instance, is being viewed using the 2-D mode, and a 3-D image is required to examine for a possible defect, the operator could punch a certain tactile key on the keyboard and begin the 3-D operation. As the multiple images are taken in the 360[degrees] circle around the part and the 3-D image is constructed by software, the operator could begin to view the image on a second screen. Once viewing is completed, the operator could then shift back to 2-D and continue the process. True-X-Ray Intensity The accuracy of a 2-D/3-D x-ray system can be attributed to a unique control technology called true x-ray intensity (TXI TXI Transmit Immediate TXI Taxable Income TXI Transmit Immediate Protocol ). Unlike systems that measure and control the input level of the high voltage The term high voltage characterizes electrical circuits, in which the voltage used is the cause of particular safety concerns and insulation requirements. High voltage is used in electrical power distribution, in cathode ray tubes, to generate X-rays and particle beams, to and current to the x-ray tube, TXI is a process that controls and stabilizes output intensity for x-ray emission even over a long time range of inspection (hours). The result is a sharp, consistent 2-D image and data that can be reconstructed into a complete 3-D image. Without precise control over the x-ray intensity, the reconstructed 3-D image would be degraded and may not even be possible to achieve (Figure 2). [FIGURE 2 OMITTED] Applications for 2-D/3-D Inspection Combined 2-D/3-D x-ray inspection is, first and foremost, a design, production and quality control tool. For R&D requirements, a 2-D/3-D x-ray inspection system can be employed to develop and refine the manufacturing process, and it is ideal for inspecting prototypes during pre-production. It can also be used for reverse engineering of existing products. In terms of electronic assemblies, a 2-D/3-D system could be used off-line to inspect components and packages. Cracks, voids, delamination delamination /de·lam·i·na·tion/ (de-lam?i-na´shun) separation into layers, as of the blastoderm. de·lam·i·na·tion n. 1. A splitting or separation into layers. 2. and other component anomalies can be observed and measured in either the 2-D or 3-D mode, whichever most accurately depicts the defect. This type of system is also particularly useful in the manufacture of sensors and relays and other micro-electro-mechanical (MEMS (MicroElectroMechanical Systems) Tiny mechanical devices that are built onto semiconductor chips and are measured in micrometers. In the research labs since the 1980s, MEMS devices began to materialize as commercial products in the mid-1990s. ) and micro-opto-electromechanical (MOEMS See MEMS. ) devices. Dr. Udo E. Frank is director of research and development at FEINFOCUS, Garbsen, Germany; +49-5131-7098-0; email: info@feinfocus.com. |
|
||||||||||||||||

Printer friendly
Cite/link
Email
Feedback
Reader Opinion